Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Micromachines (Basel) ; 14(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37893250

RESUMO

Dielectrophoresis (DEP) is a powerful tool for label-free sorting of cells, even those with subtle differences in morphological and dielectric properties. Nevertheless, a major limitation is that most existing DEP techniques can efficiently sort cells only at low throughputs (<1 mL h-1). Here, we demonstrate that the integration of a three-dimensional (3D) coupled hydrodynamic-DEP cell pre-focusing module upstream of the main DEP sorting region enables cell sorting with a 10-fold increase in throughput compared to conventional DEP approaches. To better understand the key principles and requirements for high-throughput cell separation, we present a comprehensive theoretical model to study the scaling of hydrodynamic and electrostatic forces on cells at high flow rate regimes. Based on the model, we show that the critical cell-to-electrode distance needs to be ≤10 µm for efficient cell sorting in our proposed microfluidic platform, especially at flow rates ≥ 1 mL h-1. Based on those findings, a computational fluid dynamics model and particle tracking analysis were developed to find optimum operation parameters (e.g., flow rate ratios and electric fields) of the coupled hydrodynamic-DEP 3D focusing module. Using these optimum parameters, we experimentally demonstrate live/dead K562 cell sorting at rates as high as 10 mL h-1 (>150,000 cells min-1) with 90% separation purity, 85% cell recovery, and no negative impact on cell viability.

2.
Lab Chip ; 23(11): 2577-2585, 2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37133350

RESUMO

Measurement of fluid viscosity represents a huge need for many biomedical and materials processing applications. Sample fluids containing DNA, antibodies, protein-based drugs, and even cells have become important therapeutic options. The physical properties, including viscosity, of these biologics are critical factors in the optimization of the biomanufacturing processes and delivery of therapeutics to patients. Here we demonstrate an acoustic microstreaming platform termed as microfluidic viscometer by acoustic streaming transducers (µVAST) that induces fluid transport from second-order microstreaming to measure viscosity. Validation of our platform is achieved with different glycerol content mixtures to reflect different viscosities and shows that viscosity can be estimated based on the maximum speed of the second-order acoustic microstreaming. The µVAST platform requires only a small volume of fluid sample (∼1.2 µL), which is 16-30 times smaller than that of commercial viscometers. In addition, µVAST can be scaled up for ultra-high throughput measurements of viscosity. Here we demonstrate 16 samples within 3 seconds, which is an attractive feature for automating the process flows in drug development and materials manufacturing and production.


Assuntos
Glicerol , Microfluídica , Humanos , Viscosidade , Acústica , Transdutores
3.
bioRxiv ; 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36993279

RESUMO

Chimeric antigen receptor (CAR) T-cell therapy shows unprecedented efficacy for cancer treatment, particularly in treating patients with various blood cancers, most notably B-cell acute lymphoblastic leukemia (B-ALL). In recent years, CAR T-cell therapies are being investigated for treating other hematologic malignancies and solid tumors. Despite the remarkable success of CAR T-cell therapy, it has unexpected side effects that are potentially life threatening. Here, we demonstrate the delivery of approximately the same amount of CAR gene coding mRNA into each T cell propose an acoustic-electric microfluidic platform to manipulate cell membranes and achieve dosage control via uniform mixing, which delivers approximately the same amount of CAR genes into each T cell. We also show that CAR expression density can be titered on the surface of primary T cells under various input power conditions using the microfluidic platform.

4.
Adv Healthc Mater ; 12(12): e2203163, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36645182

RESUMO

In this study, efficient T cell activation is demonstrated using cell-sized artificial antigen-presenting cells (aAPCs) with protein-conjugated bilayer lipid membranes that mimic biological cell membranes. The highly uniform aAPCs are generated by a facile method based on standard droplet microfluidic devices. These aAPCs are able to activate the T cells in peripheral blood mononuclear cells, showing a 28-fold increase in interferon gamma (IFNγ) secretion, a 233-fold increase in antigen-specific CD8 T cells expansion, and a 16-fold increase of CD4 T cell expansion. The aAPCs do not require repetitive boosting or additional stimulants and can function at a relatively low aAPC-to-T cell ratio (1:17). The research presents strong evidence that the surface fluidity and size of the aAPCs are critical to the effective formation of immune synapses essential for T cell activation. The findings demonstrate that the microfluidic-generated aAPCs can be instrumental in investigating the physiological conditions and mechanisms for T cell activation. Finally, this method demonstrates the feasibility of customizable aAPCs for a cost-effective off-the-shelf approach to immunotherapy.


Assuntos
Células Apresentadoras de Antígenos , Leucócitos Mononucleares , Ativação Linfocitária , Imunoterapia/métodos , Lipídeos
5.
Lab Chip ; 21(18): 3615-3616, 2021 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-34472547

RESUMO

Correction for 'The vascular niche in next generation microphysiological systems' by Makena L. Ewald et al., Lab Chip, 2021, DOI: 10.1039/d1lc00530h.

6.
Lab Chip ; 21(17): 3244-3262, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34396383

RESUMO

In recent years, microphysiological system (MPS, also known as, organ-on-a-chip or tissue chip) platforms have emerged with great promise to improve the predictive capacity of preclinical modeling thereby reducing the high attrition rates when drugs move into trials. While their designs can vary quite significantly, in general MPS are bioengineered in vitro microenvironments that recapitulate key functional units of human organs, and that have broad applications in human physiology, pathophysiology, and clinical pharmacology. A critical next step in the evolution of MPS devices is the widespread incorporation of functional vasculature within tissues. The vasculature itself is a major organ that carries nutrients, immune cells, signaling molecules and therapeutics to all other organs. It also plays critical roles in inducing and maintaining tissue identity through expression of angiocrine factors, and in providing tissue-specific milieus (i.e., the vascular niche) that can support the survival and function of stem cells. Thus, organs are patterned, maintained and supported by the vasculature, which in turn receives signals that drive tissue specific gene expression. In this review, we will discuss published vascularized MPS platforms and present considerations for next-generation devices looking to incorporate this critical constituent. Finally, we will highlight the organ-patterning processes governed by the vasculature, and how the incorporation of a vascular niche within MPS platforms will establish a unique opportunity to study stem cell development.


Assuntos
Dispositivos Lab-On-A-Chip , Pâncreas , Humanos
7.
Sci Rep ; 11(1): 14512, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34267274

RESUMO

This study analyzes the swelling behavior of native, unmodified, spherically uniform, monodisperse poly(lactic-co-glycolic acid) (PLGA) microparticles in a robust high-throughput manner. This work contributes to the complex narrative of PLGA microparticle behavior and release mechanisms by complementing and extending previously reported studies on intraparticle microenvironment, degradation, and drug release. Microfluidically produced microparticles are incubated under physiological conditions and observed for 50 days to generate a profile of swelling behavior. Microparticles substantially increase in size after 15 days, continue increasing for 30 days achieving size dependent swelling indices between 49 and 83%. Swelling capacity is found to correlate with pH. Our study addresses questions such as onset, duration, swelling index, size dependency, reproducibility, and causal mechanistic forces surrounding swelling. Importantly, this study can serve as the basis for predictive modeling of microparticle behavior and swelling capacity, in addition to providing clues as to the microenvironmental conditions that encapsulated material may experience.

8.
Lab Chip ; 21(7): 1197-1198, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33877233
9.
Lab Chip ; 21(7): 1333-1351, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33605955

RESUMO

Around 95% of anti-cancer drugs that show promise during preclinical study fail to gain FDA-approval for clinical use. This failure of the preclinical pipeline highlights the need for improved, physiologically-relevant in vitro models that can better serve as reliable drug-screening and disease modeling tools. The vascularized micro-tumor (VMT) is a novel three-dimensional model system (tumor-on-a-chip) that recapitulates the complex human tumor microenvironment, including perfused vasculature, within a transparent microfluidic device, allowing real-time study of drug responses and tumor-stromal interactions. Here we have validated this microphysiological system (MPS) platform for the study of colorectal cancer (CRC), the second leading cause of cancer-related deaths, by showing that gene expression, tumor heterogeneity, and treatment responses in the VMT more closely model CRC tumor clinicopathology than current standard drug screening modalities, including 2-dimensional monolayer culture and 3-dimensional spheroids.


Assuntos
Antineoplásicos , Neoplasias Colorretais , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Avaliação Pré-Clínica de Medicamentos , Humanos , Dispositivos Lab-On-A-Chip , Microambiente Tumoral
10.
Microsyst Nanoeng ; 7: 4, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33456784

RESUMO

The vascular network of the circulatory system plays a vital role in maintaining homeostasis in the human body. In this paper, a novel modular microfluidic system with a vertical two-layered configuration is developed to generate large-scale perfused microvascular networks in vitro. The two-layer polydimethylsiloxane (PDMS) configuration allows the tissue chambers and medium channels not only to be designed and fabricated independently but also to be aligned and bonded accordingly. This method can produce a modular microfluidic system that has high flexibility and scalability to design an integrated platform with multiple perfused vascularized tissues with high densities. The medium channel was designed with a rhombic shape and fabricated to be semiclosed to form a capillary burst valve in the vertical direction, serving as the interface between the medium channels and tissue chambers. Angiogenesis and anastomosis at the vertical interface were successfully achieved by using different combinations of tissue chambers and medium channels. Various large-scale microvascular networks were generated and quantified in terms of vessel length and density. Minimal leakage of the perfused 70-kDa FITC-dextran confirmed the lumenization of the microvascular networks and the formation of tight vertical interconnections between the microvascular networks and medium channels in different structural layers. This platform enables the culturing of interconnected, large-scale perfused vascularized tissue networks with high density and scalability for a wide range of multiorgan-on-a-chip applications, including basic biological studies and drug screening.

11.
Lab Chip ; 21(5): 875-887, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33351008

RESUMO

We demonstrate a label free and high-throughput microbubble-based acoustic microstreaming technique to isolate rare circulating cells such as circulating cancer associated fibroblasts (cCAFs) in addition to circulating tumor cells (CTCs) and immune cells (i.e. leukocytes) from clinically diagnosed patients with a capture efficiency of 94% while preserving cell functional integrity within 8 minutes. The microfluidic device is self-pumping and was optimized to increase flow rate and achieve near perfect capturing of rare cells enabled by having a trapping capacity above the acoustic vortex saturation concentration threshold. Our approach enables rapid isolation of CTCs, cCAFs and their associated clusters from blood samples of cancer patients at different stages. By examining the combined role of cCAFs and CTCs in early cancer onset and metastasis progression, the device accurately diagnoses both cancer and the metastatic propensity of breast cancer patients. This was confirmed by flow cytometry where we observed that metastatic breast cancer blood samples had significantly higher percentage of exhausted CD8+ T cells expressing programmed cell death protein 1 (PD1), higher number of CD4+ T regulatory cells and T helper cells. We show for the first time that our lateral cavity acoustic transducers (LCATs)-based approach can thus be developed into a metastatic propensity assay for clinical usage by elucidating cancer immunological responses and the complex relationships between CTCs and its companion tumor microenvironment.


Assuntos
Neoplasias da Mama , Fibroblastos Associados a Câncer , Células Neoplásicas Circulantes , Acústica , Linhagem Celular Tumoral , Separação Celular , Feminino , Humanos , Microambiente Tumoral
12.
Lab Chip ; 20(11): 1889-1890, 2020 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-32432286
13.
Ann Biomed Eng ; 48(3): 905-912, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32026231

RESUMO

This paper provides a synopsis of discussions related to biomedical engineering core curricula that occurred at the Fourth BME Education Summit held at Case Western Reserve University in Cleveland, Ohio in May 2019. This summit was organized by the Council of Chairs of Bioengineering and Biomedical Engineering, and participants included over 300 faculty members from 100+ accredited undergraduate programs. This discussion focused on six key questions: QI: Is there a core curriculum, and if so, what are its components? QII: How does our purported core curriculum prepare students for careers, particularly in industry? QIII: How does design distinguish BME/BIOE graduates from other engineers? QIV: What is the state of engineering analysis and systems-level modeling in BME/BIOE curricula? QV: What is the role of data science in BME/BIOE undergraduate education? QVI: What core experimental skills are required for BME/BIOE undergrads? s. Indeed, BME/BIOI core curricula exists and has matured to emphasize interdisciplinary topics such as physiology, instrumentation, mechanics, computer programming, and mathematical modeling. Departments demonstrate their own identities by highlighting discipline-specific sub-specialties. In addition to technical competence, Industry partners most highly value our students' capacity for problem solving and communication. As such, BME/BIOE curricula includes open-ended projects that address unmet patient and clinician needs as primary methods to prepare graduates for careers in industry. Culminating senior design experiences distinguish BME/BIOE graduates through their development of client-centered engineering solutions to healthcare problems. Finally, the overall BME/BIOE curriculum is not stagnant-it is clear that data science will become an ever-important element of our students' training and that new methods to enhance student engagement will be of pedagogical importance as we embark on the next decade.


Assuntos
Engenharia Biomédica/educação , Currículo , Ciência de Dados , Humanos , Estudantes , Universidades
14.
Biosens Bioelectron ; 152: 111982, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-32056730

RESUMO

Human neural stem and progenitor cells (hNSPCs) have therapeutic potential to treat neural diseases and injuries since they provide neuroprotection and differentiate into astrocytes, neurons, and oligodendrocytes. However, cultures of hNSPCs are heterogeneous, containing cells linked to distinct differentiated cell fates. HNSPCs that differentiate into astrocytes are of interest for specific neurological diseases, creating a need for approaches that can detect and isolate these cells. Astrocyte-biased hNSPCs differ from other cell types in electrophysiological properties, namely membrane capacitance, and we hypothesized that this could be used to enrich these cells using dielectrophoresis (DEP). We implemented a two-step DEP sorting scheme, consisting of analysis to define the optimal sorting frequency followed by separation of cells at that frequency, to test whether astrocyte-biased cells could be separated from the other cell types present in hNSPC cultures. We developed a novel device that increased sorting reproducibility and provided both enriched and depleted cell populations in a single sort. Astrocyte-biased cells were successfully enriched from hNSPC cultures by DEP sorting, making this the first study to use electrophysiological properties for label-free enrichment of human astrocyte-biased cells. Enriched astrocyte-biased human cells enable future experiments to determine the specific properties of these important cells and test their therapeutic efficacy in animal models of neurological diseases.


Assuntos
Separação Celular/instrumentação , Dispositivos Lab-On-A-Chip , Células-Tronco Neurais/citologia , Astrócitos/citologia , Técnicas Biossensoriais/instrumentação , Linhagem Celular , Capacitância Elétrica , Desenho de Equipamento , Humanos , Neurônios/citologia , Oligodendroglia/citologia
15.
Biomicrofluidics ; 13(6): 064111, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31737160

RESUMO

We created an integrated microfluidic cell separation system that incorporates hydrophoresis and dielectrophoresis modules to facilitate high-throughput continuous cell separation. The hydrophoresis module consists of a serpentine channel with ridges and trenches to generate a diverging fluid flow that focuses cells into two streams along the channel edges. The dielectrophoresis module is composed of a chevron-shaped electrode array. Separation in the dielectrophoresis module is driven by inherent cell electrophysiological properties and does not require cell-type-specific labels. The chevron shape of the electrode array couples with fluid flow in the channel to enable continuous sorting of cells to increase throughput. We tested the new system with mouse neural stem cells since their electrophysiological properties reflect their differentiation capacity (e.g., whether they will differentiate into astrocytes or neurons). The goal of our experiments was to enrich astrocyte-biased cells. Sorting parameters were optimized for each batch of neural stem cells to ensure effective and consistent separations. The continuous sorting design of the device significantly improved sorting throughput and reproducibility. Sorting yielded two cell fractions, and we found that astrocyte-biased cells were enriched in one fraction and depleted from the other. This is an advantage of the new continuous sorting device over traditional dielectrophoresis-based sorting platforms that target a subset of cells for enrichment but do not provide a corresponding depleted population. The new microfluidic dielectrophoresis cell separation system improves label-free cell sorting by increasing throughput and delivering enriched and depleted cell subpopulations in a single sort.

16.
Lab Chip ; 19(9): 1524-1533, 2019 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-30806409

RESUMO

There is a growing need to screen multiple infections simultaneously rather than diagnosis of one pathogen at a time in order to improve the quality of healthcare while saving initial screening time and reduce costs. This is the first demonstration of a five-step protein array assay for the multiplexed detection of HIV, HPV and HSV antibodies on an integrated microfluidic system. HIV, HPV and HSV reactive antibodies from both serum and saliva were rapidly detected by acoustic streaming-based mixing and pumping to enable an integrated, rapid and simple-to-use multiplexed assay device. We validated this device with 37 serum and saliva samples to verify reactivity of patient antibodies with HIV, HPV and HSV antigens. Our technology can be adapted with different protein microarrays to detect a variety of other infections, thus demonstrating a powerful platform to detect multiple putative protein biomarkers for rapid detection of infectious diseases. This integrated microfluidic protein array platform is the basis of a potent strategy to delay progression of primary infection, reduce the risk of co-infections and prevent onward transmission of infections by point-of-care detection of multiple pathogens in both serum and oral fluids.


Assuntos
Acústica/instrumentação , Imunoensaio/instrumentação , Dispositivos Lab-On-A-Chip , Saliva/virologia , Viroses/sangue , Viroses/diagnóstico , Humanos , Viroses/imunologia
17.
Cytometry A ; 95(1): 93-100, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30536717

RESUMO

Characterization of single cell metabolism is imperative for understanding subcellular functional and biochemical changes associated with healthy tissue development and the progression of numerous diseases. However, single-cell analysis often requires the use of fluorescent tags and cell lysis followed by genomic profiling to identify the cellular heterogeneity. Identifying individual cells in a noninvasive and label-free manner is crucial for the detection of energy metabolism which will discriminate cell types and most importantly critical for maintaining cell viability for further analysis. Here, we have developed a robust assay using the droplet microfluidic technology together with the phasor approach to fluorescence lifetime imaging microscopy to study cell heterogeneity within and among the leukemia cell lines (K-562 and Jurkat). We have extended these techniques to characterize metabolic differences between proliferating and quiescent cells-a critical step toward label-free single cancer cell dormancy research. The result suggests a droplet-based noninvasive and label-free method to distinguish individual cells based on their metabolic states, which could be used as an upstream phenotypic platform to correlate with genomic statistics. © 2018 International Society for Advancement of Cytometry.


Assuntos
Leucemia/metabolismo , Microfluídica/métodos , Microscopia de Fluorescência/métodos , Análise de Célula Única/métodos , Encapsulamento de Células/métodos , Fibroblastos/citologia , Fibroblastos/metabolismo , Fluorescência , Humanos , Células Jurkat , Células K562 , NAD/metabolismo , Células Neoplásicas Circulantes/metabolismo
18.
Methods Cell Biol ; 148: 35-50, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30473073

RESUMO

Single-cell analysis is of critical importance in revealing population heterogeneity, identifying minority sub-populations of interest, as well as discovering unique characteristics of individual cells. Microfluidic platforms work at the scale comparable to cell diameter and is suitable for single-cell manipulation. Here we present a microfluidic trapping array which is able to rapidly and deterministically trap single-cells in highly-packed microwells. This chapter first describes the design and fabrication protocols of the trapping array, and then presents its two representative applications: single-cell mRNA probing when integrated with a dielectrophoretic nanotweezer (DENT), and live-cell real-time imaging when combined with fluorescence lifetime imaging microscopy (FLIM). As the single-cell trapping efficiency is determined by the channel design instead of the flow rate, this trapping array can be coupled with different microfluidic sample processing units with different flow rates for various single-cell analyses.


Assuntos
Análise em Microsséries/métodos , Microfluídica/métodos , Análise de Célula Única/métodos , Humanos , Análise em Microsséries/instrumentação , Microfluídica/instrumentação , RNA Mensageiro/análise , Análise de Célula Única/instrumentação
19.
Biomicrofluidics ; 12(5): 054104, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30271519

RESUMO

Reliable separation and isolation of target single cells from bodily fluids with high purity is of great significance for an accurate and quantitative understanding of the cellular heterogeneity. Here, we describe a fully integrated single-blood-cell analysis platform capable of size-selective cell separation from a population containing a wide distribution of sizes such as diluted blood sample and highly efficient entrapment of single monocytes. The spiked single U937 cells (human monocyte cell line) are separated in sequence by two different-sized microfilters for removing large cell clumps, white blood cells, and red blood cells and then discriminated by dielectrophoretic force and isolated individually by downstream single-cell trapping arrays. When 2% hematocrit blood cells with a final ratio of 1:1000 U937 cells were introduced under the flow rate of 0.2 ml/h, 400 U937 cells were trapped sequentially and deterministically within 40 s with single-cell occupancy of up to 85%. As a proof-of-concept, we also demonstrated single monocyte isolation from diluted blood using the integrated microfluidic device. This size-selective, label-free, and live-cell enrichment microfluidic single blood-cell isolation platform for the processing of cancer and blood cells has a myriad of applications in areas such as single-cell genetic analysis, stem cell biology, point-of-care diagnostics, and cancer diagnostics.

20.
Small ; 14(40): e1802055, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30199137

RESUMO

While lipoplex (cationic lipid-nucleic acid complex)-mediated intracellular delivery is widely adopted in mammalian cell transfection, its transfection efficiency for suspension cells, e.g., lymphatic and hematopoietic cells, is reported at only ≈5% or even lower. Here, efficient and consistent lipoplex-mediated transfection is demonstrated for hard-to-transfect suspension cells via a single-cell, droplet-microfluidics approach. In these microdroplets, monodisperse lipoplexes for effective gene delivery are generated via chaotic mixing induced by the serpentine microchannel and co-confined with single cells. Moreover, the cell membrane permeability increases due to the shear stress exerted on the single cells when they pass through the droplet pinch-off junction. The transfection efficiency, examined by the delivery of the pcDNA3-EGFP plasmid, improves from ≈5% to ≈50% for all three tested suspension cell lines, i.e., K562, THP-1, Jurkat, and with significantly reduced cell-to-cell variation, compared to the bulk method. Efficient targeted knockout of the TP53BP1 gene for K562 cells via the CRISPR (clustered regularly interspaced short palindromic repeats)-CAS9 (CRISPR-associated nuclease 9) mechanism is also achieved using this platform. Lipoplex-mediated single-cell transfection via droplet microfluidics is expected to have broad applications in gene therapy and regenerative medicine by providing high transfection efficiency and low cell-to-cell variation for hard-to-transfect suspension cells.


Assuntos
Microfluídica/métodos , Transfecção/métodos , Proteína 9 Associada à CRISPR/genética , Proteína 9 Associada à CRISPR/metabolismo , Permeabilidade da Membrana Celular/fisiologia , Humanos , Células K562 , Medicina Regenerativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...