Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 15(9)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37177239

RESUMO

Recently, due to the intensive and fast progress of the high frequency wireless communication environment, including 5th generation (5G) wireless communication, more robust substrate for printed circuit board (PCB) application, especially with less power consumption, is required. In this study, modified resins based on styrene-maleic anhydride (SMA) copolymer were prepared and evaluated as binder resin to accomplish a low dielectric constant or relative permittivity (εr: <3.0) substrate for the PCB application under ultrahigh frequencies (UHF; 1 GHz~9.4 GHz). The low εr dielectric characteristics of the modified SMA copolymer could be correlated with effects from the stereo-structure of carbon chains or conformational orientation, where the degree of crystallization was analyzed by X-ray diffraction (XRD) and nuclear magnetic resonance (NMR) spectroscopies. Prepreg films of the low εr modified SMA copolymers and their compounds with epoxy resins were also characterized in terms of dielectric loss or dissipation factor (Df), which have shown more noticeable relation with their stereo-structures as well.

2.
Biosens Bioelectron ; 159: 112186, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32364939

RESUMO

In this study, high electron mobility transistor (HEMT) device was used as an immuno biosensor to measure concentration of a stress hormone, cortisol, by using selective binding on cortisol monoclonal antibody (c-Mab). Also, the HEMT sensor was enhanced in its sensitivity through light illumination to generate photocurrent. The optical pumping could assist the biosensor to discriminate more detailed change, which could result in an increment of limit of detection (LOD) to 1.0 pM cortisol level. It was the lowest level of detection with semiconductor device-based cortisol biosensors and the enhancement of surface potential sensitivity was induced by laser light (532 nm). Output current amplificated by photocurrent was higher than dark original current at about 3.39% when gate voltage is applied with -3 V. Since the device could be applied to not only standard cortisol solution but also real human salivary sample, it is expected to apply for in vitro direct diagnosis of point-of-care test (POCT).


Assuntos
Compostos de Alumínio , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Gálio , Hidrocortisona/análise , Lasers , Transistores Eletrônicos , Compostos de Alumínio/química , Gálio/química , Humanos , Técnicas Analíticas Microfluídicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA