Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Nat Commun ; 14(1): 2328, 2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37087465

RESUMO

High-harmonic radiation can be generated when an ultra-intense laser beam is reflected from an over-dense plasma, known as a plasma mirror. It is considered a promising technique for generating intense attosecond pulses in the extreme ultraviolet and X-ray wavelength ranges. However, a solid target used for the formation of the over-dense plasma is completely damaged by the interaction. Thus, it is challenging to use a solid target for applications such as time-resolved studies and attosecond streaking experiments that require a large amount of data. Here we demonstrate that high-harmonic radiation can be continuously generated from a liquid plasma mirror in both the coherent wake emission and relativistic oscillating mirror regimes. These results will pave the way for the development of bright, stable, and high-repetition-rate attosecond light sources, which can greatly benefit the study of ultrafast laser-matter interactions.

3.
Light Sci Appl ; 12(1): 37, 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36740599

RESUMO

High-power terahertz radiation was observed to be emitted from a gas jet irradiated by 100-terawatt-class laser pulses in the laser-wakefield acceleration of electrons. The emitted terahertz radiation was characterized in terms of its spectrum, polarization, and energy dependence on the accompanying electron bunch energy and charge under various gas target conditions. With a nitrogen target, more than 4 mJ of energy was produced at <10 THz with a laser-to-terahertz conversion efficiency of ~0.15%. Such strong terahertz radiation is hypothesized to be produced from plasma electrons accelerated by the ponderomotive force of the laser and the plasma wakefields on the time scale of the laser pulse duration and plasma period. This model is examined with analytic calculations and particle-in-cell simulations to better understand the generation mechanism of high-energy terahertz radiation in laser-wakefield acceleration.

4.
Rev Sci Instrum ; 93(11): 113001, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461441

RESUMO

In all-optical Compton scattering driven by a multi-petawatt laser, it is critical to have accurate spatiotemporal synchronization between the ultrarelativistic electron bunch and the ultrahigh-intensity laser beam. Such a synchronization was realized by using two complementary optical setups. The first setup, used for the initial synchronization, recorded the spatial interferogram between the two femtosecond lasers used for a GeV electron beam production and an ultrahigh scattering laser beam. The second one, consisting of spatial and spectral interferometers, measured the time delay between the two laser beams in the range of 0-200 fs in real time. These monitoring systems played an essential role in conducting Compton scattering experiments.

5.
Rev Sci Instrum ; 93(11): 113311, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461536

RESUMO

The absolute response of a real-time proton detector, composed of a microchannel plate (MCP) assembly, an imaging lens, and a charge-coupled device (CCD) camera, is calibrated for the spectral characterization of laser-accelerated protons, using a Thomson parabola spectrometer (TPS). A slotted CR-39 plate was used as an absolute particle-counting detector in the TPS, simultaneously with the MCP-CCD detector to obtain a calibration factor (count/proton). In order to obtain the calibration factor as a function of proton energy for a wide range of proton numbers, the absolute response was investigated for different operation parameters of the MCP-CCD detector, such as MCP voltage, phosphor voltage, and CCD gain. A theoretical calculation for the net response of the MCP was in good agreement with the calibrated response of the MCP-CCD detector, and allows us to extend the response to higher proton energies. The response varies in two orders of magnitude, showing an exponential increase with the MCP voltage and almost linear increase with the phosphor voltage and the CCD gain. The calibrated detector enabled characterization of a proton energy spectrum in a wide dynamic range of proton numbers. Moreover, two MCP assemblies having different structures of MCP, phosphor screen, and optical output window have been calibrated, and the difference in the absolute response was highlighted. The highly-sensitive detector operated with maximum values of the parameters enables measuring a single proton particle and evaluating an absolute spectrum at high proton energies in a single laser shot. The absolute calibrations can be applied for the spectral measurement of protons using different operating voltages and gains for optimized response in a large range of proton energy and number.

6.
Opt Express ; 30(15): 26212-26219, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-36236816

RESUMO

We analyzed and corrected the wavefront distortion induced during the post-compression of a 100-TW Ti:Sapphire laser and achieved the intensity enhancement. In the post-compression, the spectral broadening of the laser was obtained by propagating through three 0.5 mm-thick fused silica plates and the laser pulse duration was post-compressed from 24 fs to 11 fs using a set of chirped mirrors. We measured the wavefront aberrations due to the intensity-dependent nonlinear process during the post-compression of femtosecond high-power laser pulses. By compensating for the wavefront aberrations with an adaptive optics system, the Strehl ratio of the post-compressed beam was improved from 0.37 to 0.52 and the focused intensity of the post-compressed beam could be enhanced by a factor of 1.5, while the enhancement without the wavefront correction was only a factor of 1.1 in spite of the peak-power enhancement by a factor of 1.8.

7.
Sci Rep ; 12(1): 11128, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778463

RESUMO

A localized nanoparticle insertion scheme is developed to decouple electron injection from laser evolution in laser wakefield acceleration. Here we report the experimental realization of a controllable electron injection by the nanoparticle insertion method into a plasma medium, where the injection position is localized within the short range of 100 µm. Nanoparticles were generated by the laser ablation process of a copper blade target using a 3-ns 532-nm laser pulse with fluence above 100 J/cm2. The produced electron bunches with a beam charge above 300 pC and divergence of around 12 mrad show the injection probability over 90% after optimizing the ablation laser energy and the temporal delay between the ablation and the main laser pulses. Since this nanoparticle insertion method can avoid the disturbing effects of electron injection process on laser evolution, the stable high-charge injection method can provide a suitable electron injector for multi-GeV electron sources from low-density plasmas.

8.
Opt Express ; 30(6): 8734-8741, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35299319

RESUMO

We demonstrated sub-10 fs pulse generation by the post-compression of a 100 TW Ti:Sapphire laser to enhance the peak-power. In the post-compression, the laser spectrum was widely broadened by self-phase modulation in thin fused silica plate(s), and the induced spectral phase was compensated with a set of chirped mirrors. A spatial filter stage, consisting of two cylindrical lenses and a spherical lens, was employed to reduce the intensity modulation existing in the laser beam, which effectively suppressed intensity spikes induced by self-focusing. The laser beam was post-compressed from 23 fs to 9.7 fs after propagating through a 1.5 mm fused silica plate, resulting in the peak-power enhancement by a factor of 2.1.

9.
Opt Express ; 29(13): 19506-19514, 2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34266059

RESUMO

The single-shot spatiotemporal characterization of an ultrahigh intensity laser pulse was performed using a multispectral wavefront sensor. For the measurement of the spatio-spectral electric field, a femtosecond laser pulse was spectrally modulated and separated by a Fabry-Perot etalon coupled with a grating pair, and its spatio-spectral electric field was measured with a wavefront sensor. The spatiotemporal electric field was reconstructed from the measured spatio-spectral electric field of a multi-PW laser pulse. We found that the spatiotemporal distortion could reduce the focused laser intensity by 15%, compared to the case of a diffraction-limited and transform-limited laser pulse.

10.
Rev Sci Instrum ; 92(2): 023302, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648087

RESUMO

We present a proof of principle for onsite calibration of a radiochromic film (EBT3) using CR-39 as an absolute proton-counting detector and laser-accelerated protons as a calibration source. A special detector assembly composed of aluminum range filters, an EBT3 film, and a CR-39 detector is used to expose the EBT3 film with protons in an energy range of 3.65 MeV-5.85 MeV. In our design, the proton beam is divided into small beamlets and their projection images are taken on the EBT3 film and the CR-39 detector by maintaining a certain distance between the two detectors. Owing to the geometrical factor of the configuration and scattering inside the EBT3, the areal number density of protons was kept below the saturation level of the CR-39 detector. We also present a method to relate the number of protons detected on the CR-39 in a narrow energy range to protons with a broad energy spectrum that contribute to the dose deposited in the EBT3 film. The energy spectrum of protons emitted along the target normal direction is simultaneously measured using another CR-39 detector installed in a Thomson parabola spectrometer. The calibration curves for the EBT3 film were obtained in the optical density range of 0.01-0.25 for low dose values of 0.1 Gy-3.0 Gy. Our results are in good agreement with the calibrations of the EBT3 film that are traditionally carried out using conventional accelerators. The method presented here can be further extended for onsite calibration of radiochromic films of other types and for a higher range of dose values.

11.
Opt Express ; 28(26): 38842-38856, 2020 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-33379444

RESUMO

Angular dispersion observed in a nanosecond optical parametric chirped-pulse amplification (ns-OPCPA) amplifier adopted in the frontend of a multi-PW laser was analyzed. The theory on the angular dispersion, extended by including the wavefront rotation and the pulse front tilt of a strongly chirped laser pulse, revealed that the wavefront rotation is a major contributor to the angular dispersion, as compared to the pulse front tilt, in a ns-OPCPA amplifier. It was also shown that the wavefront rotation could be introduced by the phase mismatch and the noncollinear propagation angle in the noncollinear ns-OPCPA amplifier. The theoretical prediction was experimentally verified by measuring the angular dispersion of the ns-OPCPA frontend installed in the 20-fs, 4-PW Ti:Sapphire laser. We emphasize the importance of the proper characterization and control of the angular dispersion in the ns-OPCPA amplifier since the focus intensity of an ultrahigh power laser could be significantly reduced due to the spatiotemporal effect even for small induced angular dispersion.

12.
Opt Lett ; 45(23): 6342-6345, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33258807

RESUMO

We present a highly efficient double plasma mirror (DPM) that provides ultrahigh-contrast multi-petawatt (PW) laser pulses with a temporal contrast ratio reaching 1017 up to 160 ps and 1012 up to 2 ps before the main pulse. The high reflectivity of 70%, along with the high-contrast enhancement factor of 700,000, was achieved from the DPM installed after the final stage of a 4 PW Ti:sapphire laser. The 4 PW laser was equipped with cross-polarized wave generation and optical parametric chirped-pulse amplification stages for initial high-contrast operation. The DPM operation was undertaken with conditions that did not modify the spatiotemporal profiles of incident multi-PW laser pulses. This highly efficient DPM with the high-contrast enhancement promises the utilization of multiple PMs as a practical rear end for upcoming tens of petawatt lasers to achieve ultrahigh temporal contrast.

13.
Sci Rep ; 10(1): 18452, 2020 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-33116228

RESUMO

With the recent advances in ultrahigh intensity lasers, exotic astrophysical phenomena can be investigated in laboratory environments. Collisionless shock in a plasma, prevalent in astrophysical events, is produced when a strong electric or electromagnetic force induces a shock structure in a time scale shorter than the collision time of charged particles. A near-critical-density (NCD) plasma, generated with an intense femtosecond laser, can be utilized to excite a collisionless shock due to its efficient and rapid energy absorption. We present electrostatic shock acceleration (ESA) in experiments performed with a high-density helium gas jet, containing a small fraction of hydrogen, irradiated with a 30 fs, petawatt laser. The onset of ESA exhibited a strong dependence on plasma density, consistent with the result of particle-in-cell simulations on relativistic plasma dynamics. The mass-dependent ESA in the NCD plasma, confirmed by the preferential reflection of only protons with two times the shock velocity, opens a new possibility of selective acceleration of ions by electrostatic shock.

15.
Opt Lett ; 45(13): 3617-3620, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32630913

RESUMO

We demonstrate efficient multicycle terahertz pulse generation at 14.6 THz from large-area lithium niobate crystals by using high-energy (up to 2 J) femtosecond Ti:sapphire laser pulses. Such terahertz radiation is produced by phase-matched optical rectification in lithium niobate. Experimentally, we achieve maximal terahertz energy of 0.71 mJ with conversion efficiency of ∼0.04%. Our experimental setup is simple and easily upscalable to produce multi-millijoule, multicycle terahertz radiation with proper lithium niobate crystals.

16.
Opt Lett ; 44(22): 5634-5637, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31730126

RESUMO

We demonstrate high-energy terahertz generation from a large-aperture (75-mm diameter) lithium niobate wafer by using a femtosecond laser with energy up to 2 J. This scheme utilizes optical rectification in a bulk lithium niobate crystal, where most terahertz energy is emitted from a thin layer of the rear surface. Despite its simple setup, this scheme can yield 0.19 mJ of terahertz energy with laser-to-terahertz conversion efficiencies of ∼10-4, about 3 times better than ZnTe when pumped at 800 nm. The experimental setup is upscalable for multimillijoule terahertz generation with petawatt laser pumping.

17.
Opt Express ; 27(15): 20412-20420, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31510135

RESUMO

The generation of ultrahigh intensity laser pulses was investigated by tightly focusing a wavefront-corrected multi-petawatt Ti:sapphire laser. For the wavefront correction of the PW laser, two stages of deformable mirrors were employed. The multi-PW laser beam was tightly focused by an f/1.6 off-axis parabolic mirror and the focal spot profile was measured. After the wavefront correction, the Strehl ratio was about 0.4, and the spot size in full width at half maximum was 1.5×1.8 µm2, close to the diffraction-limited value. The measured peak intensity was 5.5×1022 W/cm2, achieving the highest laser intensity ever reached.

18.
Sci Rep ; 9(1): 11249, 2019 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-31375722

RESUMO

The phase velocity of the wakefield of a laser wakefield accelerator can, theoretically, be manipulated by shaping the longitudinal plasma density profile, thus controlling the parameters of the generated electron beam. We present an experimental method where using a series of shaped longitudinal plasma density profiles we increased the mean electron peak energy more than 50%, from 175 ± 1 MeV to 262 ± 10 MeV and the maximum peak energy from 182 MeV to 363 MeV. The divergence follows closely the change of mean energy and decreases from 58.9 ± 0.45 mrad to 12.6 ± 1.2 mrad along the horizontal axis and from 35 ± 0.3 mrad to 8.3 ± 0.69 mrad along the vertical axis. Particle-in-cell simulations show that a ramp in a plasma density profile can affect the evolution of the wakefield, thus qualitatively confirming the experimental results. The presented method can increase the electron energy for a fixed laser power and at the same time offer an energy tunable source of electrons.

19.
Phys Rev Lett ; 122(1): 014803, 2019 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-31012707

RESUMO

We report the experimental generation of highly energetic carbon ions up to 48 MeV per nucleon by shooting double-layer targets composed of well-controlled slightly underdense plasma and ultrathin foils with ultraintense femtosecond laser pulses. Particle-in-cell simulations reveal that carbon ions are ejected from the ultrathin foils due to radiation pressure and then accelerated in an enhanced sheath field established by the superponderomotive electron flow. Such a cascaded acceleration is especially suited for heavy ion acceleration with femtosecond laser pulses. The breakthrough of heavy ion energy up to many tens of MeV/u at a high repetition rate would be able to trigger significant advances in nuclear physics, high energy density physics, and medical physics.

20.
Opt Express ; 26(19): 24775-24783, 2018 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-30469589

RESUMO

We developed an OPCPA preamplifier with an actively shaped output spectrum to obtain a sub-20-fs-duration pulse for a 4-PW laser. The active spectral shaping was facilitated by controlling the temporal profile of a pump pulse in the OPCPA preamplifier. By optimizing the output spectrum of the OPCPA to compensate for the gain-depletion effect in the 4-PW laser, a final laser pulse with a broad spectrum of 101-nm in width (FWHM), resulting in a short pulse duration of 17 fs, was achieved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...