1.
Orthop J Sports Med ; 12(1): 23259671231218649, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38274016

RESUMO

Background: The arthroscopic Broström technique with or without Gould modification has been used to treat patients with anterior talofibular ligament injury who failed nonoperative management and progressed to chronic lateral ankle instability. However, some patients develop limited range of motion over the ankle joint postoperatively. Purpose/Hypothesis: To compare the clinical outcomes and midterm functional performance of knot-tying techniques between using a knot pusher and a semiconstrained freehand tie during arthroscopic Broström-Gould procedure with inferior extensor retinaculum (IER) augmentation. It was hypothesized that the semiconstrained freehand tie would provide better plantarflexion of the ankle joint compared with the knot pusher. Study Design: Cohort study; Level of evidence, 3. Methods: Included were 135 consecutive patients with mild-to-moderate lateral ankle instability (mean age, 42.7 years; range, 16-78 years) who underwent an arthroscopic Broström-Gould procedure from March 1, 2016, to April 30, 2022. The patients were divided into 2 groups according to the tying technique used in the Gould modification: surgical tie using a knot pusher (KP group; n = 30) or a semiconstrained freehand tie (FT group; n = 105). Radiographic parameters and ultrasound dynamic testing were examined during the preoperative assessment. Preoperative and 2-year postoperative assessments comprised American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale, visual analog scale for pain, and 12-Item Short Form Survey (SF-12) scores. Results: The 2 groups had no differences in age, sex, or severity distribution in the preoperative assessment. American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale, visual analog scale pain, and SF-12 scores were significantly better at the postoperative evaluation (all P < .05) in both groups. No significant difference was noted between groups in outcome scores. In the KP group, however, 7 out of 30 patients (23.3%) developed ankle stiffness with tightness when performing plantarflexion movement. No patients in the FT group reported similar symptoms. Conclusion: For mild-to-moderate chronic lateral ankle instability, we propose an arthroscopic Broström procedure with the addition of IER augmentation using a semiconstrained freehand tie to avoid overtightening the IER. This ensures favorable patient satisfaction and clinical outcomes without limitation of plantarflexion of the ankle joint and avoids the possible complication of stiffness with plantarflexion.

2.
BMC Musculoskelet Disord ; 23(1): 715, 2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-35897013

RESUMO

BACKGROUND: Müller-Weiss disease (MWD), a rare dysplastic disorder of the foot, is characterized by deformity, sclerosis, and fragmentation of the lateral part of navicular bone. Arthrodesis is the mainstay treatment for MWD. Generally, arthrodesis can be achieved through internal fixation with metallic implants, and morselized chip bone may be packed into the gap for better bone union. However, with this procedure, the original foot size is not maintained and support for the foot arch is not provided. Sequela of short foot, or flatfoot is commonly observed even though these complications of surgery had not been reported with cases of MWD treated by arthrodesis. Herein, we present a retrospective analysis of treating MWD through midfoot and hindfoot arthrodesis combined with strut allograft. METHODS: From August 2006 to June 2019, 20 patients with MWD (mean age, 59.6 years; range, 40-80 years) underwent midfoot and hindfoot arthrodesis with strut bone allograft and were followed for at least 24 months. The patients were able to ambulate and participate in rehabilitation programs 3 months postoperatively. RESULTS: The used four radiographic parameters (Meary's angle in anteroposterior and lateral view, talonavicular coverage angle, calcaneal pitch) demonstrated significant differences (P < .05) preoperatively and postoperatively, but those between the postoperative values and the values at the last follow-up session did not, indicating that strut allograft was able to maintain normal alignment. The mean American Orthopaedic Foot & Ankle Society Ankle-Hindfoot scores at 2 years postoperatively revealed significant improvement from baseline, from 60.2 to 84.2 (P < .05). The 12-item Short Form Health Survey scores also improved significantly (P < .05). All patients reported substantial pain relief and exhibited improved functional outcomes and gait patterns. CONCLUSIONS: For advanced-stage MWD, arthrodesis with a precisely shaped, size-matched strut allograft provided strong support for biomechanical alignment and enhanced functional performance.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Doenças do Pé , Ossos do Tarso , Aloenxertos , Artrodese/efeitos adversos , Artrodese/métodos , Humanos , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Ossos do Tarso/cirurgia , Resultado do Tratamento
3.
J Orthop Surg Res ; 12(1): 194, 2017 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-29268797

RESUMO

BACKGROUND: Dialysis-related destructive spondyloarthropathy caused by beta-2 microglobulin (ß2M) amyloid deposits in intervertebral discs is a major burden for patients undergoing long-term dialysis. This study aimed to quantify the presence of ß2M amyloid deposits in the intervertebral disc tissue of such patients and analyze whether there was a significant correlation between ß2M accumulation and the duration of dialysis. METHODS: Two groups of patients who had undergone surgery for degenerative spinal pathologies were selected: the dialysis group (n = 29) with long-term dialysis and the control group (n = 10) with no renal impairment. Tissue sections were prepared from specimens of intervertebral disc tissue obtained during spinal surgery and analyzed via histological staining, including immunohistochemistry (IHC) and Congo red. RESULTS: There was a statistically significant multifold increase of ß2M expression in the disc tissue of long-term dialysis patients when compared to non-dialysis patients, as shown by both IHC (0.019 ± 0.023 µm2 vs. 0.00020 ± 0.00033 µm2, respectively; p = 0.012) and Congo red staining (0.027 ± 0.041 µm2 vs. 9.240 × 10-5 ± 5.261 × 10-5 µm2, respectively; p = 0.047). We also note a moderate strength positive correlation between the duration of dialysis and positive IHC (r = 0.39; p = 0.015) and Congo-red staining (r = 0.42; p = 0.007). CONCLUSIONS: The problem of ß2M amyloidosis in long-term dialysis patients remains unresolved even with predominant use of high-flux dialysis membranes. This highlights the insufficiency of current dialysis modalities to effectively filter ß2M.


Assuntos
Disco Intervertebral/química , Falência Renal Crônica/terapia , Diálise Renal/métodos , Microglobulina beta-2/análise , Adulto , Idoso , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/patologia , Falência Renal Crônica/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo
4.
IEEE Trans Biomed Eng ; 60(9): 2603-13, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23674408

RESUMO

Operation in minimally invasive surgery is more difficult since the surgeons perform operations without haptic feedback or depth perception. Moreover, the field of view perceived by the surgeons through endoscopy is usually quite limited. The goal of this paper is to allow surgeons to see wide-angle images from endoscopy without the drawback of lens distortion. The proposed distortion correction process consists of lens calibration and real-time image warping. The calibration step is to estimate the parameters in the lens distortion model. We propose a fully automatic Hough-entropy-based calibration algorithm, which provides calibration results comparable to the previous manual calibration method. To achieve real-time correction, we use graphics processing unit to warp the image in parallel. In addition, surgeons may adjust the focal length of a lens during the operation. Real-time distortion correction of a zoomable lens is impossible by using traditional calibration methods because the tedious calibration process has to repeat again if focal length is changed. We derive a formula to describe the relationship between the distortion parameter, focal length, and image boundary. Hence, we can estimate the focal length for a zoomable lens from endoscopic images online and achieve real-time lens distortion correction.


Assuntos
Algoritmos , Endoscopia/métodos , Processamento de Imagem Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Calibragem , Simulação por Computador , Bases de Dados Factuais , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...