Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(10): e0292942, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37851656

RESUMO

PURPOSE: To identify how the inner retinal layer and microvasculature change with age by analyzing the relationships of ganglion cell-inner plexiform layer (GC-IPL) thickness, vessel density (VD), and the ratio of these measurements with age in healthy eyes. METHODS: Participants were divided into five groups according to age. The GC-IPL thickness, VD, and GC-IPL/VD ratio were compared among the groups. Linear regression analyses were performed to identify relationships of GC-IPL/VD ratio with age. RESULTS: The average GC-IPL thicknesses were 84.84 ± 5.28, 84.22 ± 5.30, 85.20 ± 6.29, 83.29 ± 7.06, and 82.26 ± 5.62 µm in the 20s, 30s, 40s, 50s, and 60s age groups, respectively. The VDs were 20.94 ± 1.50, 21.06 ± 1.50, 20.99 ± 1.03, 20.71 ± 0.93, and 19.74 ± 1.73 mm-1 in the 20s, 30s, 40s, 50s, and 60s age groups, respectively. The GC-IPL/VD ratio was 4.05, 4.00, 4.06, 4.02, and 4.17 in each group, respectively, and the ratio of the 60s age group was significantly higher than that of other groups. In linear regression analyses, the GC-IPL/VD ratio was significantly associated with age in the participants aged ≥ 50 years (B = 0.014, P = 0.013), whereas it was not in the participants aged < 50 years (B = 0.003, P = 0.434). CONCLUSIONS: GC-IPL thickness and macular VD showed a tendency to decrease beginning in the 50s age group and the GC-IPL/VD ratio was significantly increased in the 60s age group. Additionally, the GC-IPL/VD ratio was positively associated with age in subjects aged ≥ 50 years, which implies a more pronounced decline over time in VD rather than GC-IPL thickness.


Assuntos
Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Pessoa de Meia-Idade , Fibras Nervosas , Retina , Microvasos
2.
Materials (Basel) ; 15(19)2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36233972

RESUMO

In this work, a cerium/tetraethylenepentamine dithiocarbamate complex was synthesized and evaluated for the corrosion inhibition capability on an AA2024-T3 Al alloy in a 3.5% NaCl medium. The synthesized compounds were characterized via spectroscopic techniques. The corrosion inhibition behaviour of the complex was elucidated by electrochemical measurements and surface analysis techniques. Based on electrochemical test results, the corrosion inhibition efficiency of the complex increases with the immersion time of aluminium alloy in the test solution. The corrosion inhibition reaches 96.80% when the aluminium is immersed in a 3.5% NaCl solution containing a corrosion inhibitor for 120 h. The potentiodynamic polarization test results show that the complex acts as a mixed-type corrosion inhibitor and the passive range is widened. The surface analysis methods reveal that the corrosion inhibition ability of the complex originated from the formation of a protective layer on the Al surface. This film is created from the physisorption and chemisorption of cerium ions and organic parts simultaneously released from the complex molecules.

3.
Sci Rep ; 12(1): 17357, 2022 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-36253380

RESUMO

Spectral-domain optical coherence tomography (SD-OCT) must accurately identify and measure the peripapillary retinal nerve fiber layer (pRNFL) thickness to improve the repeatability and reproducibility, and reduce measurement errors. Because Weiss ring can be located in front of the optic disc, we hypothesized that it may affect pRNFL thickness measurements obtained using SD-OCT. We retrospectively reviewed the medical records of patients with (group W) and without (group N) Weiss ring, observed on OCT fundus image and an RNFL map devised using SD-OCT. Optic disc cube scans (200 × 200) were obtained to measure pRNFL thicknesses (superior, temporal, inferior, nasal, and average) at two consecutive visits. Pearson's correlation coefficient (r), intraclass correlation coefficient (ICC), and coefficient of variation (CV) were calculated. The r and ICC values for the pRNFL thickness measurements at the two visits were lower for group W compared to group N, but statistical significance was reached only for inferior pRNFL thickness. In addition, CV values were greater for group W compared to group N, but the differences were significant only for inferior and average pRNFL thickness measurements (p < 0.001 and p = 0.004, respectively). Weiss ring located near the optic disc can affect pRNFL thickness measurements and repeatability thereof, especially the inferior quadrant and average values. Therefore, it is important to identify the presence of Weiss ring when analyzing pRNFL thickness values.


Assuntos
Fibras Nervosas , Tomografia de Coerência Óptica , Humanos , Reprodutibilidade dos Testes , Células Ganglionares da Retina , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos
4.
Acta Ophthalmol ; 100(1): e150-e156, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33884766

RESUMO

PURPOSE: Acute and chronic hypertension may have different pathophysiological mechanisms in the retina. Here, we compared the retinal nerve fibre layer (RNFL)/ganglion cell-inner plexiform layer (GC-IPL) thickness ratios of patients with 'relieved' severe hypertensive retinopathy (relieved HTNR) and chronic hypertension without retinopathy (chronic HTN) to those of normal controls. METHODS: We performed cross-sectional study. The eyes were divided into the following groups: normal controls (Group A, age ≥50 years; Group D, age <50 years); chronic HTN (Group B, <10 years of HTN; TNHT; Group C, ≥10 years of HTN); and relieved HTNR (previously diagnosed with grade IV HTNR and relieved retinopathy for >1 year; Group E), and the RNFL/GC-IPL thickness ratio was compared among Groups A-C and between Groups D and E. RESULTS: A total of 379 eyes were included in this study. Groups A-E consisted of 145, 59, 63, 60 and 52 eyes, respectively. The RNFL/GC-IPL thickness ratios were 1.161 ± 0.093, 1.158 ± 0.082 and 1.162 ± 0.089 in groups A-C, respectively, and did not showed a statistically difference (p = 0.966). The RNFL/GC-IPL thickness ratio of groups D and E were 1.169 ± 0.080 and 1.221 ± 0.080, respectively, and showed a statistically difference (p = 0.001). CONCLUSIONS: The RNFL/GC-IPL thickness ratios of the chronic HTN group did not show a difference compared with the normal controls. However, relieved HTNR patients showed a higher ratio than the normal controls. Physicians should be aware that acute hypertensive injury could affect the RNFL/GC-IPL thickness ratio.


Assuntos
Hipertensão/complicações , Doenças Retinianas/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Biometria , Pressão Sanguínea/fisiologia , Estudos Transversais , Feminino , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Doenças Retinianas/etiologia
5.
Sci Rep ; 11(1): 23832, 2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34903817

RESUMO

This is a prospective observational study to establish the short- and long-term repeatability of measurements of peripapillary optical coherence tomography angiography (OCTA) parameters in healthy eyes and identify factors affecting long-term repeatability. We enrolled 84 healthy eyes. Participants with a history of any ophthalmic disease (except high myopia) or intraocular surgery were excluded from the study. An experienced examiner performed OCTA using disc-centered 6 × 6 mm scans. All examinations were conducted twice at 5-min intervals at the initial visit and repeated at least 6 months later. For short-term repeatability, the coefficient of variation (CV) was 2.94-4.22% and the intraclass correlation coefficient (ICC) was 0.840-0.934. For long-term repeatability, the CV was 2.73-3.84% and the ICC was 0.737-0.934. Multivariate analyses showed that the axial length (AL) (B = 0.970; p = 0.002) and mean signal strength (SS) (B = - 2.028; p < 0.001) significantly affected long-term repeatability. Measurements of peripapillary OCTA parameters exhibited excellent short-term and good long-term repeatability in healthy individuals. The mean SS and AL affected long-term repeatability and should be considered while interpreting peripapillary OCTA images.


Assuntos
Angiografia/métodos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Angiografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/normas
6.
Medicine (Baltimore) ; 100(39): e27391, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596164

RESUMO

RATIONALE: Several reports have described retinal pigment epithelial (RPE) tears in central serous chorioretinopathy (CSC). However, there have been no reports of spontaneously large RPE tears in acute CSC without bullous retinal detachment (RD). Herein, we report and provide sequential images of a case of bilateral spontaneous large RPE tears in patient with acute CSC without bullous RD. PATIENT CONCERNS: An 88-year-old female patient was admitted with impaired vision in both eyes, which began 10 days prior. The visual acuity was 0.4 and 0.5 in the right and left eye, respectively. She had started taking oral steroids 2 weeks prior for polymyalgia. DIAGNOSIS: Ophthalmologic examinations, including fundus photography, optical coherence tomography, and fluorescence angiography, were performed, and she was diagnosed with steroid-induced acute CSC in both eyes with large pigment epithelial detachment (PED) of approximately 4-disc diameter. Discontinuation of steroids and follow-up ophthalmic examinations were performed. However, a spontaneous large RPE tear occurred in the right eye. INTERVENTIONS: We performed follow-ups more frequently and CSC treatment such as laser photocoagulation, photodynamic therapy, and anti-vascular endothelial growth factor injections were not performed. OUTCOMES: Nine months later, a spontaneous large RPE tear occurred sequentially in the left eye. Her final visual acuity was 0.3 and 0.15 in the right and left eye, respectively. LESSONS: Patients may spontaneously develop large RPE tears in both eyes, despite no treatment for acute CSC with non-bullous RD. Large PED and old age may affect this. Therefore, for a CSC patient with a large PED and advanced age, attention must be paid when determining treatment.


Assuntos
Coriorretinopatia Serosa Central/complicações , Perfurações Retinianas/etiologia , Idoso de 80 Anos ou mais , Coriorretinopatia Serosa Central/induzido quimicamente , Coriorretinopatia Serosa Central/diagnóstico , Feminino , Angiofluoresceinografia , Humanos , Descolamento Retiniano/etiologia , Perfurações Retinianas/diagnóstico por imagem , Perfurações Retinianas/patologia , Esteroides/administração & dosagem , Esteroides/efeitos adversos , Tomografia de Coerência Óptica , Acuidade Visual
7.
PLoS One ; 16(10): e0258479, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34648529

RESUMO

OBJECTIVE: To investigate the effects of axial length (AL) on the peripapillary microvascular density acquired from optical coherence tomography angiography (OCTA). METHODS: Retrospective observational study. A total of 111 eyes from 111 normal healthy subjects were examined. The subjects were divided into three groups according to the AL: Group 1 (AL: < 24.0 mm; 35 eyes), Group 2 (AL: 24.0-25.99 mm; 37 eyes), and Group 3 (AL: ≥ 26 mm; 39 eyes). Peripapillary OCTA images were acquired using 6× 6 mm angiography scans, and vessel density (VD) and perfusion density (PD) of the superficial capillary plexus were calculated automatically. VD and PD were compared among the three groups according to the distance from the optic disc (inner and outer rings). Linear regression analyses were also performed to identify clinical factors associated with average VD. RESULTS: The average ALs of Groups 1-3 were 23.33± 0.57, 25.05± 0.60, and 27.42± 0.82, respectively. Average VD (P = 0.009) and PD (P = 0.029) in the inner ring increased with increasing AL. However, average VD (P < 0.001) and PD (P < 0.001) in the outer ring decreased with AL increased; the same trends were found for the full areas (VD, p<0.001; PD, p = 0.001). Average VDs in the inner and outer rings were not associated (P = 0.938). CONCLUSIONS: Peripapillary VD and PD were significantly associated with AL. Depending on the distance from the disc, peripapillary VDs and PDs of the inner and outer rings were differentially affected by AL. Physicians should therefore consider the effects of AL in the analyses of peripapillary microvasculature.


Assuntos
Microvasos/fisiologia , Tomografia de Coerência Óptica/métodos , Adulto , Estudos de Casos e Controles , Feminino , Angiofluoresceinografia , Humanos , Modelos Lineares , Masculino , Microvasos/diagnóstico por imagem , Pessoa de Meia-Idade , Disco Óptico/fisiologia , Estudos Retrospectivos
8.
ACS Omega ; 6(39): 25529-25538, 2021 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-34632210

RESUMO

A new approach to the recycling of spent coffee grounds is described in which lignin, a chemical component of spent coffee, is used as an electrolyte additive in aluminum-air batteries. The effect of lignin on the performance of aluminum-air batteries has been investigated by weight loss measurement, galvanostatic discharge test, and electrochemical impedance spectroscopy (EIS). The corrosion inhibition efficiency is improved up to 37.3% and fuel efficiency up to 21.7% at 500 ppm of lignin molecules. The chemisorption of lignin molecules on the aluminum surface improves battery performance. Adsorption of lignin molecules onto the aluminum surface is driven by the electrostatic interaction between the lignin's hydroxyl group and the aluminum surface. The mechanism for the performance improvement is explained by the chemisorption behavior of lignin molecules. The adsorption behavior has been investigated by scanning electronic microscopy with energy-dispersive spectroscopy (SEM-EDS), laser scanning microscopy (LSM), atomic force microscopy (AFM), Freundlich adsorption isotherm, Fourier-transform infrared (FT-IR) spectroscopy, and the computational calculation of adsorption energies based on the density functional theory (DFT).

9.
J Clin Med ; 10(18)2021 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-34575366

RESUMO

BACKGROUND: We aimed to study the bilateral choroidal thickness (CT) symmetry and difference in uncomplicated pachychoroid subjects using wide-field swept-source optical coherence tomography (SS-OCT). METHODS: All subjects underwent a wide-field 16-mm one-line scan using SS-OCT. Bilateral CT was measured at, and compared among, the following 12 points: three points at 900-µm intervals from the nasal optic disc margin (nasal peripapillary area), one point at the subfovea, six points at 900-µm intervals from the fovea to the nasal and temporal areas (macular area), and two peripheral points 5400 and 8100 µm from the fovea (peripheral area). RESULTS: There were no statistically significant differences in CT between the right and left eyes in any area (all p > 0.05); they all showed significant positive correlations (all p < 0.01). However, the correlation coefficients (ρ) were smaller for the nasal peripapillary and peripheral areas compared to the macular area. CONCLUSIONS: The CTs in each region were bilaterally symmetrical in subjects with uncomplicated pachychoroid. However, interocular difference in CT increased from the center to the periphery, indicating that the anatomical variation of the nasal peripapillary and peripheral choroid was greater than that of the macula.

10.
Invest Ophthalmol Vis Sci ; 62(12): 21, 2021 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-34546323

RESUMO

Purpose: To identify the impact of hypertension (HTN) on macular microvasculature in type 2 diabetes (T2DM) patients without clinical diabetic retinopathy. Methods: In this retrospective cross-sectional study, subjects were divided into three groups: controls (control group), patients with T2DM (DM group), and patients with both T2DM and HTN (DM + HTN group). The vessel length density (VD) was compared among the groups. Linear regression analyses were performed to identify factors associated with VD. Results: The VD in the control, DM, and DM + HTN groups was 20.43 ± 1.16, 19.50 ± 1.45, and 18.19 ± 2.06 mm-1, respectively (P < 0.001). The best-corrected visual acuity (B = -9.30; P = 0.002), duration of T2DM (B = -0.04; P = 0.020), HTN (B = -0.51; P = 0.016), signal strength (B = 1.12; P < 0.001), and ganglion cell-inner plexiform layer thickness (B = 0.06; P < 0.001) were significant factors affecting VD in patients with T2DM. Additionally, the hemoglobin A1c (HbA1c) (B = -0.49; P = 0.016) was significantly associated with VD in patients with both T2DM and HTN. Conclusions: Patients with T2DM had impaired macular microvasculature, and patients with T2DM with HTN exhibited greater impairment of the microvasculature than did patients with T2DM only. Additionally, physicians should be aware that the macular microvasculature would be more vulnerable to hyperglycemic damage under ischemic conditions by HTN.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Retinopatia Diabética/fisiopatologia , Hipertensão/fisiopatologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/fisiopatologia , Idoso , Pressão Sanguínea/fisiologia , Estudos Transversais , Feminino , Angiofluoresceinografia , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Microvasos/fisiopatologia , Pessoa de Meia-Idade , Células Ganglionares da Retina/patologia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
11.
Diabetes ; 70(11): 2663-2667, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34475099

RESUMO

Type 2 diabetes mellitus (T2DM) and hypertension (HTN) are both relatively common systemic diseases and cause damage to the retina, such as inner retina reduction and microvascular impairment. The purpose of this study was to identify peripapillary retinal nerve fiber layer (pRNFL) damage by diabetic neurodegeneration and the effects of HTN on the pRNFL thickness in patients with T2DM without clinical diabetic retinopathy. Subjects were divided into three groups: healthy control subjects (group 1), patients with T2DM (group 2), and patients with both diabetes and HTN (group 3). The pRNFL thickness was measured using optical coherence tomography and compared among each group. Linear regression analyses were performed to identify factors associated with pRNFL thickness. A total of 325 eyes were included: 143 eyes in the group 1, 126 eyes in group 2, and 56 eyes in group 3. The mean pRNFL thicknesses of each group were 96.1 ± 7.7, 94.4 ± 8.6, and 91.6 ± 9.6 µm, respectively (P = 0.003). In multivariate linear analyses, diabetes duration (ß = -0.236; P = 0.018) and HTN (ß = -3.766; P = 0.008) were significant factors affecting the pRNFL thickness in groups 2 and 3. Additionally, the HTN duration was significantly correlated with pRNFL thickness in group 3 (R 2 = 0.121; P = 0.008). In conclusion, patients with T2DM with HTN showed thinner pRNFL thickness than those with T2DM only. Additionally, the duration of HTN was significantly correlated with pRNFL thickness in patients with both diabetes and HTN.


Assuntos
Diabetes Mellitus Tipo 2/patologia , Retinopatia Diabética/patologia , Hipertensão/patologia , Neurônios Retinianos/patologia , Idoso , Estudos Transversais , Feminino , Hemoglobinas Glicadas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual
12.
Sci Rep ; 11(1): 15509, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-34330991

RESUMO

This study aimed to quantify the Haller vessel and choriocapillaris (CC) parameters in drusen subtypes in nonexudative age-related macular degeneration (AMD) and pachydrusen. Ninety-five eyes of 80 patients and 28 control eyes were categorized into soft drusen, subretinal drusenoid deposit (SDD), soft drusen plus SDD, pachydrusen, and control groups. The diameter, length and intersections of Haller vessels and the total area, size and number of CC flow voids were quantified using en face optical coherence tomography (OCT) or OCT angiography. The pachydrusen group showed the largest Haller vessel area and diameter and shortest total length but similar CC parameters to those in the control group. The soft drusen plus SDD group showed the largest CC flow void area and size, while the Haller parameters were similar to those in the control group. The area and size of the flow voids in the SDD group were smaller than those in the soft drusen plus SDD group. Based on unsupervised machine learning, the eyes were classified into 4 clusters-the control, pachydrusen, soft drusen plus SDD and soft drusen plus SDD groups. Cluster 3 showed a larger diameter and shorter total length of the Haller vessels than cluster 4.


Assuntos
Corioide/patologia , Degeneração Macular/patologia , Drusas Retinianas/patologia , Idoso , Corioide/metabolismo , Feminino , Humanos , Degeneração Macular/metabolismo , Masculino , Pessoa de Meia-Idade , Drusas Retinianas/metabolismo , Tomografia de Coerência Óptica
13.
J Clin Med ; 10(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064150

RESUMO

The Bruch's membrane opening-minimum rim width (BMO-MRW) is a recently introduced parameter of the neuroretinal rim. We analyzed the repeatability of spectral-domain optical coherence tomography (SD-OCT) measurements of BMO-MRW in epiretinal membrane (ERM) patients with peripapillary involvement, since the surface around the optic disc is distorted in such patients. BMO-MRW and retinal nerve fiber layer (RNFL) thickness measurements were performed using SD-OCT in prospectively enrolled ERM patients and age-matched healthy control individuals. After two consecutive measurements with a 5 min interval, repeatability was analyzed using the intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CV). Fifty-two eyes of 52 ERM patients and 62 eyes of 62 healthy controls were included in the study. The ICCs of the mean BMO-MRW/RNFL thickness measurements were 0.999/0.985 in ERM eyes and 0.999/0.999 in normal eyes, respectively. The RC values of mean BMO-MRW/RNFL thickness measurements were 9.0/6.25 µm in ERM eyes and 4.61/0.92 µm in normal eyes, respectively. The CV values were 0.91% and 1.45% for BMO-MRW and RNFL thickness in ERM eyes, and 0.63% and 0.33% in normal eyes, respectively. In ERM eyes, the RC, CV of average BMO-MRW were 1.9 and 1.4 times greater than those of normal eyes, but 6.8 and 4.4 times greater for average RNFL thickness. BMO-MRW and RNFL thickness showed good repeatability in the diseased eyes with peripapillary involvement and healthy control eyes. Based on the ICC, RC, and CV values, the repeatability of BMO-MRW measurements in peripapillary membrane patients was better than that of RNFL thickness.

14.
Biosensors (Basel) ; 11(4)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918811

RESUMO

Sensing targeted tumor markers with high sensitivity provides vital information for the fast diagnosis and treatment of cancer patients. A vascular endothelial growth factor (VEGF165) have recently emerged as a promising biomarker of tumor cells. The electrochemical aptasensor is a promising tool for detecting VEGF165 because of its advantages such as a low cost and quantitative analysis. To produce a sensitive and stable sensor electrode, nanocomposites based on polyaniline (PANI) and carbon nanotube (CNT) have potential, as they provide for easy fabrication, simple synthesis, have a large surface area, and are suitable in biological environments. Here, a label-free electrochemical aptasensor based on nanocomposites of CNT and PANI was prepared for detecting VEGF165 as a tumor marker. The nanocomposite was assembled with immobilized VEGF165 aptamer as a highly sensitive VEGF165 sensor. It exhibited stable and wide linear detection ranges from 0.5 pg/mL to 1 µg/mL, with a limit of detection of 0.4 pg/mL because of the complementary effect of PANI/CNT. The fabricated aptasensor also exhibited good stability in biological conditions, selectivity, and reproducibility after several measurement times after the dissociation process. Thus, it could be applied for the non-invasive determination of VEGF, in biological fluid diagnosis kits, or in an aptamer-based biosensor platform in the near future.


Assuntos
Técnicas Biossensoriais , Nanocompostos , Fator A de Crescimento do Endotélio Vascular/análise , Compostos de Anilina , Biomarcadores Tumorais , Eletrodos , Humanos , Nanotubos de Carbono , Reprodutibilidade dos Testes
15.
Retina ; 41(11): 2301-2309, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33830961

RESUMO

PURPOSE: It is hypothesized that an unstable tear film would affect the quality and repeatability of optical coherence tomography angiography (OCTA). Therefore, OCTA repeatability according to tear break-up time (TBUT) was compared. METHODS: The 3 × 3 OCTA was performed twice and, the eyes were divided into 3 groups according to the TBUT (Group 1: TBUT ≤ 5 seconds, 43 eyes; Group 2: 5 seconds < TBUT ≤ 10 seconds, 35 eyes; Group 3: TBUT > 10 seconds, 34 eyes). The intraclass correlation coefficient, coefficient of variation, and test-retest SD were calculated and compared. RESULTS: The signal strengths of OCTA were 9.1 ± 1.2, 9.5 ± 0.8, and 9.5 ± 0.8 in each group from Groups 1, 2, and 3, respectively, which showed significant difference (P = 0.049). The intraclass correlation coefficient of vessel density were 0.733, 0.840, and 0.974 in Groups 1 to 3, respectively, and the values increased in the order of Groups 1, 2, and 3. The coefficient of variation were 6.41 ± 6.09, 3.29 ± 2.22, and 1.30 ± 1.17, and the test-retest SD were 0.83 ± 0.70, 0.47 ± 0.31, and 0.19 ± 0.17 in Groups 1, 2, and 3, respectively. The coefficient of variation and test-retest SD values decreased in the order of Groups 1, 2, and 3, and showed a significant difference (all, P < 0.05). CONCLUSION: The repeatability of OCTA tended to decrease with a shorter TBUT. When the TBUT is <5 seconds, care must be taken to interpret the OCTA results correctly.


Assuntos
Síndromes do Olho Seco/diagnóstico , Angiofluoresceinografia/métodos , Microvasos/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Lágrimas/metabolismo , Tomografia de Coerência Óptica/métodos , Adulto , Síndromes do Olho Seco/metabolismo , Feminino , Seguimentos , Fundo de Olho , Humanos , Masculino , Estudos Retrospectivos , Adulto Jovem
16.
Invest Ophthalmol Vis Sci ; 62(2): 9, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33733716

RESUMO

Purpose: The purpose of this study to identify the effects of prolonged type 2 diabetes (T2DM) on the peripapillary retinal nerve fiber layer (pRNFL) and peripapillary microvasculature in patients with prolonged T2DM without clinical diabetic retinopathy (DR). Methods: Subjects were divided into 3 groups: controls (control group; 153 eyes), patients with T2DM < 10 years (DM group 1; 136 eyes), and patients with T2DM ≥ 10 years (DM group 2; 74 eyes). The pRNFL thickness and peripapillary superficial vessel density (VD) were compared. Linear regression analyses were performed to identify factors associated with peripapillary VD in patients with T2DM. Results: The mean pRNFL thicknesses of the control group, DM group 1, and DM group 2 were 96.0 ± 7.9, 94.5 ± 0.9, and 92.2 ± 8.2 µm, respectively (P < 0.001). The VDs were 18.24 ± 0.62, 17.60 ± 1.47, and 17.15 ± 1.38 mm-1 in the control group, DM group 1, and DM group 2, respectively (P < 0.001). In multivariate linear regression analyses, visual acuity (B = -2.460, P = 0.001), axial length (B = -0.169, P = 0.008), T2DM duration (B = -0.056, P < 0.001), and pRNFL (B = 0.024, P = 0.001) were significant factors affecting the peripapillary VD in patients with T2DM. Conclusions: Patients with T2DM without clinical DR showed thinner pRNFL and lower peripapillary VD and perfusion density (PD) compared with normal controls, and such damage was more severe in patients with T2DM ≥ 10 years. Additionally, peripapillary VD was significantly associated with best-corrected visual acuity (BCVA), axial length, T2DM duration, and pRNFL thickness in patients with T2DM.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/diagnóstico , Microvasos/patologia , Disco Óptico/irrigação sanguínea , Células Ganglionares da Retina/patologia , Vasos Retinianos/patologia , Acuidade Visual , Estudos Transversais , Retinopatia Diabética/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Estudos Retrospectivos , Tomografia de Coerência Óptica
17.
Invest Ophthalmol Vis Sci ; 62(3): 5, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33656554

RESUMO

Purpose: The purpose of this paper was to study the bilateral choroidal thickness (CT) symmetry and differences in healthy individuals using wide-field swept-source optical coherence tomography (SS-OCT). Methods: All participants underwent a wide-field 16-mm 1-line scan using SS-OCT. CTs were measured at the following 12 points: 3 points at 900 µm, 1800 µm, and 2700 µm away from the nasal optic disc margin (nasal peripapillary area), 1 point at the subfovea, 6 points at 900 µm, 1800 µm, and 2700 µm away from the subfovea to the nasal and temporal areas (macular area), and 2 peripheral points at 2700 and 5400 µm from temporal point 3 (peripheral area). Bilateral CTs were measured; their correlations and differences in the corresponding regions were analyzed. Results: There were no statistically significant differences in CTs between the right and left eyes in all corresponding areas (all P > 0.05); they all showed significant positive correlation coefficients (r) (all P < 0.001). However, the nasal peripapillary and peripheral areas had relatively low correlation coefficients, compared to the macular areas. In addition, the bilateral CT differences were 32.60 ± 25.80 µm in the macular area, 40.67 ± 30.58 µm in the nasal peripapillary area, and 56.03 ± 45.73 µm in the peripheral area (all P < 0.001). Conclusions: Overall, the CTs of each region were bilaterally symmetrical. However, the differences in CTs increased from the center to the periphery, which indicated that the anatomic variation of the nasal peripapillary and peripheral choroid was greater than that of the macula.


Assuntos
Corioide/anatomia & histologia , Corioide/diagnóstico por imagem , Tomografia de Coerência Óptica , Adulto , Comprimento Axial do Olho/anatomia & histologia , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Pressão Intraocular/fisiologia , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Acuidade Visual/fisiologia
18.
Medicine (Baltimore) ; 100(9): e24706, 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33655935

RESUMO

RATIONALE: A few cases of optic neuropathy presumed to be caused by vincristine have been reported. However, none described multimodal imaging findings. Here, we report abnormal magnetic resonance imaging (MRI) and optical coherence tomography (OCT) findings in a putative case of vincristine-induced optic neuropathy. PATIENT CONCERNS: A 9-year-old boy with Burkett lymphoma who had had no visual problems noticed blurred vision in both eyes 22 days after the first maintenance therapy for lymphoma; the blurred gradually worsened. At that time, the best-corrected visual acuity was 20/200 and 20/100 in the right and left eyes, respectively. DIAGNOSES: Blood and imaging workup, and cerebrospinal fluid and genetic analyses, were performed; these included fundus photography, OCT, and MRI. We found no plausible cause of the optic neuropathy other than vincristine. INTERVENTIONS: The scheduled chemotherapy was stopped, and the patient was managed with high-dose corticosteroids. However, as there was no improvement, plasma exchange was then performed. OUTCOMES: Three days after the initial examination, the visual acuity in both eyes was only light perception and projection. Signal intensity was abnormally high on 3-dimensional T2-weighted turbo spin echo and T2-weighted MRI images. Optic disc atrophy progressed to "total pallor"; thinning of the ganglion cell-inner plexiform and retinal nerve fiber layers also progressed. The patient was followed up for 7 months but showed no improvement in vision. There were no treatment-related complications. LESSONS: We conclude that vincristine can cause optic neuropathy, and clinicians need to be alert to the possibility of optic neuropathy in any patient prescribed this agent.OCT and MRI may help to diagnose optic neuropathy in pediatric patients. Periodic ophthalmologic examinations, including an OCT scan, may be useful.


Assuntos
Antineoplásicos Fitogênicos/efeitos adversos , Imageamento por Ressonância Magnética , Doenças do Nervo Óptico/diagnóstico por imagem , Tomografia de Coerência Óptica , Vincristina/efeitos adversos , Criança , Humanos , Linfoma/tratamento farmacológico , Masculino , Imagem Multimodal , Doenças do Nervo Óptico/induzido quimicamente
19.
Acta Ophthalmol ; 99(1): e117-e123, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32573109

RESUMO

PURPOSE: We investigated the wide-field choroidal thickness (CT) using swept-source optical coherence tomography (SS-OCT) and compared the characteristics of the choroidal layer between pachychoroid and normochoroid groups. METHODS: A total of 120 eyes from 120 normal subjects were included. All subjects were divided into two groups according to the subfoveal CT (≥300 µm, pachychoroid group; <300µm, normochoroid group). All subjects underwent an HD spotlight 16 mm scan using SS-OCT. The CT was measured at the following 12 points: subfoveal, 3 points in the nasal peripapillary area, 6 points in the macular area and 2 peripheral points at 5400 and 8100 µm from the fovea. The CT measurements were compared between the two groups, and statistical analyses were performed to determine clinical factors associated with each point of the CT. RESULTS: The CT in the pachychoroid group was thicker than that in the normochoroid group at all points (p < 0.01). The CTs of the two groups in the macular area were highly associated with the subfoveal CT. However, the CTs of the nasal peripapillary and peripheral areas showed lower associations with the subfoveal CT and lower diagnostic abilities for the pachychoroid group. The existence of pachyvessels was found to be a significant factor causing the regional variations. CONCLUSIONS: The CTs in the peripapillary and peripheral areas showed different patterns than the subfoveal CT. Regional variations by pachyvessels were more frequent in the peripapillary and peripheral areas than in the macular area, and the subfoveal CT did not represent the whole choroidal area.


Assuntos
Corioide/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Feminino , Seguimentos , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
PLoS One ; 15(9): e0239555, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32966311

RESUMO

OBJECTIVE: To investigate the thicknesses of the ganglion cell-inner plexiform layer (GC-IPL) and retinal nerve fiber layer (RNFL) of the fellow eyes of patients with unilateral exudative age-related macular degeneration (AMD). METHODS: A total of 107 patients with unilateral exudative AMD [34 of typical choroidal neovascularization (tCNV), Group A; 73 of polypoidal choroidal vasculopathy (PCV), Group B] and 73 normal control eyes (Group C) were included. Drusen and subretinal drusenoid deposits were assessed in all participants using fundus photography, autofluorescence, and optical coherence tomography (OCT). The GC-IPL and RNFL thicknesses were measured using Cirrus HD-OCT and compared among groups. Linear regression analyses were used to evaluate the factors associated with GC-IPL thicknesses. RESULTS: The average GC-IPL thicknesses of Groups A, B, and C were 77.09 ± 3.87, 80.10 ± 6.61, and 80.88 ± 6.50 µm, respectively (p = 0.022). Sectoral GC-IPLs and central macular thicknesses (CMTs) were significantly different among groups (all, p <0.05), whereas none of the RNFL parameters differed significantly (all, p >0.05). Multivariate linear regression analyses revealed that age (p <0.001), CMT (p <0.001), and tCNV (p = 0.013) were significantly associated with average GC-IPL thickness, and the rate of reduction of GC-IPL thickness with increasing age in the fellow eyes of tCNV patients was higher than those in the PCV and control groups. CONCLUSIONS: Unilateral tCNV patients exhibited statistically significant reduction of the GC-IPL thickness in the fellow eyes, compared to values of the fellow eyes of unilateral PCV patients or control patients. RNFL values trended to be lower but did not reach statistical significance.


Assuntos
Degeneração Macular/diagnóstico por imagem , Retina/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Neovascularização de Coroide/diagnóstico por imagem , Neovascularização de Coroide/patologia , Feminino , Angiofluoresceinografia , Humanos , Degeneração Macular/patologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Retina/patologia , Células Ganglionares da Retina/patologia , Neurônios Retinianos/patologia , Estudos Retrospectivos , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...