Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(21): e38293, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38787987

RESUMO

Metabolic rate has been used in thermophysiological models for predicting the thermal response of humans. However, only a few studies have investigated the association between an individual's trait-like thermal sensitivity and resting energy expenditure (REE), which resulted in inconsistent results. This study aimed to explore the association between REE and perceived thermal sensitivity. The REE of healthy adults was measured using an indirect calorimeter, and perceived thermal intolerance and sensation in the body were evaluated using a self-administered questionnaire. In total, 1567 individuals were included in the analysis (women = 68.9%, age = 41.1 ±â€…13.2 years, body mass index = 23.3 ±â€…3.3 kg/m2, REE = 1532.1 ±â€…362.4 kcal/d). More women had high cold intolerance (31.8%) than men (12.7%), and more men had high heat intolerance (23.6%) than women (16.1%). In contrast, more women experienced both cold (53.8%) and heat (40.6%) sensations in the body than men (cold, 29.1%; heat, 27.9%). After adjusting for age, fat-free mass, and fat mass, lower cold intolerance, higher heat intolerance, and heat sensation were associated with increased REE only in men (cold intolerance, P for trend = .001; heat intolerance, P for trend = .037; heat sensation, P = .046), whereas cold sensation was associated with decreased REE only in women (P = .023). These findings suggest a link between the perceived thermal sensitivity and REE levels in healthy individuals.


Assuntos
Calorimetria Indireta , Metabolismo Energético , Humanos , Feminino , Masculino , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Metabolismo Energético/fisiologia , Sensação Térmica/fisiologia , Metabolismo Basal/fisiologia , Fatores Sexuais , Temperatura Alta/efeitos adversos , Temperatura Baixa , Índice de Massa Corporal
2.
Healthcare (Basel) ; 12(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38727475

RESUMO

We established a protocol for the traditional Korean medicine examination (KME) and methodically gathered data following this protocol. Potential indicators for KME were extracted through a literature review; the first KME protocol was developed based on three rounds of expert opinions. The first KME protocol's feasibility was confirmed, and data were collected over four years from traditional Korean medicine (KM) hospitals, focusing on healthy adults, using the final KME protocol. A literature review identified 175 potential core indicators, condensed into 73 indicators after three rounds of expert consultation. The first KME protocol, which was categorized under questionnaires and medical examinations, was developed after the third round of expert opinions. A pilot study using the first KME protocol was conducted to ensure its validity, leading to modifications resulting in the development of the final KME protocol. Over four years, data were collected from six KM hospitals, focusing on healthy adults; we obtained a dataset comprising 11,036 healthy adults. This is the first protocol incorporating core indicators of KME in a quantitative form and systematically collecting data. Our protocol holds potential merit in evaluating predisposition to diseases or predicting diseases.

3.
bioRxiv ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38798392

RESUMO

Single-molecule localization microscopy (SMLM) enables super-resolution imaging on conventional fluorescent microscopes. Spectroscopic SMLM (sSMLM) further allows highly multiplexed super-resolution imaging. We report an easy-to-implement symmetrically dispersed dual-wedge prism (SDDWP)-sSMLM design that maximizes photon utilization. We first symmetrically dispersed photons to the -1st and +1st orders in an optical assembly using two identical dual-wedge prisms (DWPs). Then we computationally extracted the fluorophores' spatial position and spectral characteristics using photons in both the -1st and +1st orders. Theoretical analysis and experimental validation showed lateral and spectral precisions of 10.1 nm and 0.3 nm, respectively, representing improvements of 28% and 48% over our previous DWP-based system, where emitted photons are divided separately for spatial and spectral analyses.

4.
Bioact Mater ; 34: 80-97, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38143565

RESUMO

Critical limb ischemia (CLI) is a devastating disease characterized by the progressive blockage of blood vessels. Although the paracrine effect of growth factors in stem cell therapy made it a promising angiogenic therapy for CLI, poor cell survival in the harsh ischemic microenvironment limited its efficacy. Thus, an imperative need exists for a stem-cell delivery method that enhances cell survival. Here, a collagen microgel (CMG) cell-delivery scaffold (40 × 20 µm) was fabricated via micro-fragmentation from collagen-hyaluronic acid polyionic complex to improve transplantation efficiency. Culturing human adipose-derived stem cells (hASCs) with CMG enabled integrin receptors to interact with CMG to form injectable 3-dimensional constructs (CMG-hASCs) with a microporous microarchitecture and enhanced mass transfer. CMG-hASCs exhibited higher cell survival (p < 0.0001) and angiogenic potential in tube formation and aortic ring angiogenesis assays than cell aggregates. Injection of CMG-hASCs intramuscularly into CLI mice increased blood perfusion and limb salvage ratios by 40 % and 60 %, respectively, compared to cell aggregate-treated mice. Further immunofluorescent analysis revealed that transplanted CMG-hASCs have greater muscle regenerative and angiogenic potential, with enhanced cell survival than cell aggregates (p < 0.05). Collectively, we propose CMG as a cell-assembling platform and CMG-hASCs as promising therapeutics to treat CLI.

5.
Photoacoustics ; 34: 100574, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38126078

RESUMO

Combining the diffusive laser excitation and the photoacoustic signals detection, photoacoustic computed tomography (PACT) is uniquely suited for deep tissue imaging. A diffraction-limited ultrasound point detector is highly desirable for maximizing the spatial resolution and the field-of-view of the reconstructed volumetric images. Among all the available ultrasound detectors, micro-ring resonator (MRR) based ultrasound detectors offer the lowest area-normalized limit of detection (nLOD) in a miniature form-factor, making it an ideal candidate as an ultrasound point detector. However, despite their wide adoption for photoacoustic imaging, the underlying signal transduction process has not been systematically studied yet. Here we report a comprehensive theoretical model capturing the transduction of incident acoustic signals into digital data, and the associated noise propagation process, using experimentally calibrated key process parameters. The theoretical model quantifies the signal-to-noise ratio (SNR) and the nLOD under the influence of the key process variables, including the quality factor (Q-factor) of the MRR and the driving wavelength. While asserting the need for higher Q-factors, the theoretical model further quantifies the optimal driving wavelength for optimizing the nLOD. Given the MRR with a Q-factor of 1 × 105, the theoretical model predicts an optimal SNR of 30.1 dB and a corresponding nLOD of 3.75 × 10-2 mPa mm2/Hz1/2, which are in good agreement with the experimental measurements of 31.0 dB and 3.39 × 10-2 mPa mm2/Hz1/2, respectively. The reported theoretical model can be used in guiding the optimization of MRR-based ultrasonic detectors and PA experimental conditions, in attaining higher imaging resolution and contrast. The optimized operating condition has been further validated by performing PACT imaging of a human hair phantom.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA