Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Hypertens ; 40(10): 2058-2067, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36052527

RESUMO

BACKGROUND: The long-term cardiovascular consequences of microgravity on large arteries are a threat for long-term space missions. We hypothesized that changes in arterial properties differ according to the arterial territory (upper or lower body), and arterial structure (elastic vs. muscular arteries), in response to 60-day head-down bed rest (HDBR). METHOD: Twenty healthy male volunteers were included and received a daily multivitamin supplementation in a double-blind fashion. At baseline, 29 and 52 days during strict HDBR, then 12 and 30 days after HDBR, aortic stiffness was measured using carotid-to-femoral pulse wave velocity (cf-PWV) and aortic MRI. Carotid, femoral, brachial and popliteal arteries were studied by ultrasound echo tracking, central blood pressure (BP) by tonometry and endothelial function by flow-mediated dilatation. RESULTS: Cf-PWV increased during HDBR (+0.8 and +1.1m/s, at D29 and D52, respectively, P = 0.004), corresponding to an increase in vascular age up to +11 years (P = 0.003). Changes were similar to those observed on MRI (+0.8 m/s at D52, P < 0.01) and were independent of BP and heart rate changes. After HDBR, cf-PWV showed a substantial recovery at R12 but still remained higher than baseline at R30 (+0.8 m/s, P = 0.018), corresponding to +6.5 years of vascular aging (P = 0.018). Thoracic aorta diameter increased significantly (+6%, P = 0.0008). During HDBR, femoral and popliteal arteries showed dimensional changes, leading to femoral inward hypotrophic remodeling (femoral diameter: -12%, P < 0.05; wall cross-sectional area: -25%, P = 0.014) and popliteal inward eutrophic remodeling (popliteal diameter: -25%, P < 0.05; wall cross-sectional area: -3%, P = 0.51). After HDBR, both arterial territories of the leg recovered. We did not observe any significant changes for carotid arteries nor for endothelial function during and after HDBR. Multivitamin supplementation did not affect vascular changes. HDBR was associated with an important increase in aortic stiffness, which did not completely recover 1 month after the end of HDBR. The thoracic aorta and the lower body muscular arteries underwent significant changes in dimensions whereas the common carotid arteries were preserved. CONCLUSION: These results should raise caution for those exposed to microgravity, real or simulated.


Assuntos
Repouso em Cama , Rigidez Vascular , Repouso em Cama/efeitos adversos , Pressão Sanguínea , Artérias Carótidas , Método Duplo-Cego , Humanos , Masculino , Análise de Onda de Pulso
2.
Microgravity Sci Technol ; 33(1): 14, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33519098

RESUMO

Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an ultrasound probe has been installed on a Short Arm Human Centrifuge. A feasibility study was conducted to define the use capabilities and limitations of such a novel method. The objective of this study is to estimate the reproducibility and precision of remotely controlled vascular ultrasound assessment under centrifugation by assessing peripheral vascular diameter and wall distension. Four repeated centrifugation runs of 5 min, with 2.4 g at feet level, were performed including a 15 min rest between each run for a group of eight healthy male volunteers. Vascular diameter and distention were assessed for the common carotid artery (CCA) and the femoral artery (FA) by ultrasound imaging using a 10 MHz linear array probe (Mylab1, Esaote). Ultrasound measurements were consecutively performed: a) by an expert user in hand-held mode in standing as well as supine position, b) using the telerobotic arm without centrifugation as baseline and c) using the telerobotic arm during centrifugation. Vascular responses were compared between baseline and under centrifugation. Inter-, intra-registration and group variability have been assessed for hand-held and remotely controlled examination. The results show that intra-registration variability, σ h , was always smaller than inter-registration variability, σ m, that is in turned smaller than the inter-subject variability σ g (σ h < σ m < σ g). Centrifugation caused no significant changes in CCA diameter but a lower carotid distension compared to manual and robotic ultrasound in supine position (p < 0.05). Femoral diameter was significantly decreased in hypergravity compared to robotic sonography without centrifugation. A good reproducibility and precision of the remotely controlled vascular ultrasound assessment under centrifugation could be demonstrated. In conclusion, arterial wall dynamics can be precisely assessed for the CCA and femoral artery during centrifugation using a telerobotic ultrasound measurement system. Potential improvements to further enhance reproducibility and safety of the system are discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA