RESUMO

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Assuntos
Consenso , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Valor Preditivo dos Testes , Europa (Continente) , Resultado do Tratamento
2.
Eur Radiol ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418626

RESUMO

RATIONALE: To provide an overview of the current status of cardiac multimodality imaging practices in Europe and radiologist involvement using data from the European Society of Cardiovascular Radiology (ESCR) MRCT-registry. MATERIALS AND METHODS: Numbers on cardiac CT and MRI examinations were extracted from the MRCT-registry of the ESCR, entered between January 2011 and October 2023 (n = 432,265). Data collection included the total/annual numbers of examinations, indications, complications, and reporting habits. RESULTS: Thirty-two countries contributed to the MRCT-registry, including 29 European countries. Between 2011 and 2022, there was a 4.5-fold increase in annually submitted CT examinations, from 3368 to 15,267, and a 3.8-fold increase in MRI examinations, from 3445 to 13,183. The main indications for cardiac CT were suspected coronary artery disease (CAD) (59%) and transcatheter aortic valve replacement planning (21%). The number of patients with intermediate pretest probability who underwent CT for suspected CAD showed an increase from 61% in 2012 to 82% in 2022. The main MRI indications were suspected myocarditis (26%), CAD (21%), and suspected cardiomyopathy (19%). Adverse event rates were very low for CT (0.3%) and MRI (0.7%) examinations. Reporting of CT and MRI examinations was performed mainly by radiologists (respectively 76% and 71%) and, to a lesser degree, in consensus with non-radiologists (19% and 27%, respectively). The remaining examinations (4.9% CT and 1.7% MRI) were reported by non-radiological specialties or in separate readings of radiologists and non-radiologists. CONCLUSIONS: Real-life data on cardiac imaging in Europe using the largest available MRCT-registry demonstrate a considerable increase in examinations over the past years, the vast majority of which are read by radiologists. These findings indicate that radiologists contribute to meeting the increasing demands of competent and effective care in cardiac imaging to a relevant extent. CLINICAL RELEVANCE STATEMENT: The number of cardiac CT and MRI examinations has risen over the past years, and radiologists read the vast majority of these studies as recorded in the MRCT-registry. KEY POINTS: • The number of cardiac imaging examinations is constantly increasing. • Radiologists play a central role in providing cardiac CT and MR imaging services to a large volume of patients. • Cardiac CT and MR imaging examinations performed and read by radiologists show a good safety profile.

3.
Clin Imaging ; 103: 109980, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37677856

RESUMO

PURPOSE: The prognostic relevance of coronary artery calcium (CAC) density, assessed from cardiac CT scans, is established. However, the influence of CAC distribution, volume, image reconstruction, and clinical factors on CAC density warrants further examination. METHODS: In this study, 120 patients underwent non-contrast ECG-gated cardiac CT scans using a prospectively defined CAC scoring protocol with 1-, 3-, and 5-mm thick image reconstructions, both with and without a 20% image overlap. We segmented CAC in all reconstructions and assessed the relationship between CAC density, volume, and number of detected calcifications/patient. RESULTS: Overall, 75/120 (63%) patients (66% men, mean age 63 ± 11 years) presented CAC across 342 segments. CAC density, CAC volume, and the number of detected calcifications decreased with increasing slice thickness (p < 0.001 for all); these effects were slightly reduced by image overlap (p < 0.001 for all). Higher CAC density correlated with greater CAC volume (ρ = 0.62; p < 0.001) and more calcified segments per person (ρ = 0.32; p = 0.006). Higher CAC density was also associated with lower patient weight (beta: -0.6, 95%CI: -1.1--0.1, p = 0.022) and increased high-density lipoprotein (HDL) levels (beta: 0.7, 95%CI: 0.0-1.4, p = 0.046). In a multivariable analysis adjusted for clinical covariates, lower CAC density was associated with broader CAC distribution (i.e., a higher number of calcified segments at a given CAC volume; beta-coefficient: -58.9; 95%CI: -84.7 to -33.1; p < 0.001). CONCLUSION: CAC density is significantly impacted by regional CAC distribution and image reconstruction, potentially confounding its prognostic value. Accounting for these factors may improve patient risk assessment, management, and cardiovascular health outcomes.


Assuntos
Calcinose , Doença da Artéria Coronariana , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Angiografia Coronária/métodos , Fatores de Risco
4.
Int J Cardiovasc Imaging ; 39(7): 1333-1341, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36939984

RESUMO

To assess whether quantification of pulmonary perfusion defects on dual-energy computed tomography (DECT) relates to adverse events beyond clinical parameters and traditional embolus detection in patients with suspected pulmonary embolism (PE). We included consecutive patients who underwent DECT to rule out acute PE in 2018-2020 and recorded incident adverse events, defined as a composite of short-term (< 30 days) in-hospital all-cause mortality or admission to intensive care unit. Relative perfusion defect volume (PDV) was measured on DECT and indexed by total lung volume. PDV was then related to adverse events using logistic regressions adjusting for clinical parameters, clinical PE pre-test probability (Wells score), and visual PE burden on pulmonary angiography (Qanadli score). Among 136 included patients (63 [46%] females; age: 70 ± 14 years), 19/136 (14%) experienced adverse events during a median hospitalization of 7.5 (4-14) days. Overall, 7/19 (37%) events occurred in those without visible emboli but with measurable perfusion defects. An increase of PDV by one standard deviation was associated with over two times higher odds of adverse events (OR = 2.24; 95%CI:1.37-3.65; p = 0.001). This association remained significant after adjusting for the Wells and Qanadli scores (OR = 2.34; 95%CI:1.20-4.60; p = 0.013). PDV significantly increased the combined discriminatory capacity of Wells and Qanadli scores (AUC 0.76 vs. 0.80; p = 0.011 for difference). DECT-derived PDV may represent a prognostic imaging marker with incremental value beyond clinical and traditional imaging findings, improving risk stratification and aiding clinical management in patients with suspected PE.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Tomografia Computadorizada por Raios X/métodos , Prognóstico , Valor Preditivo dos Testes , Embolia Pulmonar/diagnóstico , Perfusão
5.
JACC Clin Electrophysiol ; 9(6): 790-804, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36951814

RESUMO

BACKGROUND: Data about ventricular tachycardia (VT) ablation in patients with electrical storm (ES) is limited. OBJECTIVES: This study sought to compare the prognostic outcome of patients undergoing VT ablation after ES with and without a septal substrate. METHODS: In this large single-center study, consecutive patients presenting with ES and undergoing VT ablation from June 2018 to April 2021 were included. Patients with septal substrate were compared with patients without septal substrate regarding endpoints of cardiovascular mortality, VT recurrences, recurrences of the clinical VT, and rehospitalization rates. RESULTS: A total of 107 patients undergoing a first VT ablation because of electrical storm (ES) were included (age 65 ± 13 years, 86% male, 45% ischemic cardiomyopathy). Major complications occurred in 11% of all patients with increased postinterventional third-degree atrioventricular blocks among patients with septal substrate (9% vs 0%; P = 0.063). Partial ablation successes were similar (95% with a septal substrate vs 100% without a septal substrate; P = 0.251). Complete ablation success was achieved in 63% with a septal substrate and in 87% without a septal substrate (P = 0.004). After a median 22 months of follow-up, patients with septal substrate died significantly more often from cardiovascular causes (26% vs 7%; log-rank P = 0.018). In univariate analysis cardiovascular mortality for ES patients with septal substrate was 4.1-fold higher (HR: 4.192; CI: 1.194-14.719; P = 0.025). Independent predictors of adverse outcome in multivariable regression analysis were presence of septal substrate (HR: 5.723; P = 0.025) and increased age (HR: 1.104; P = 0.003). Recurrences of any ventricular arrhythmia (67% vs 56%; log rank P = 0.554) and rehospitalization rates (80% vs 66%; log rank P = 0.515) were similar between groups. Recurrences of clinical VT were similar (7% vs 2%; P = 0.252). CONCLUSIONS: Presence of a septal substrate is associated with adverse long-term cardiovascular mortality in patients admitted for VT ablation after ES. Despite decreased acute ablation successes in these patients, VT recurrence rates were similar to those without a septal substrate during follow-up.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Prognóstico , Isquemia Miocárdica/complicações , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Recidiva
6.
Rofo ; 195(2): 115-134, 2023 02.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-36634682

RESUMO

This position paper is a joint statement of the German Radiological Society (DRG) and the Professional Association of German Radiologists (BDR), which reflects the current state of knowledge about coronary computed tomography. It is based on preclinical and clinical studies that have investigated the clinical relevance as well as the technical requirements and fundamentals of cardiac computed tomography. CITATION FORMAT: · Langenbach MC, Sandstede J, Sieren M et al. DRG and BDR Position Paper on Coronary CT: Clinical Evidence and Quality of Patient Care in Chronic Coronary Syndrome. Fortschr Röntgenstr 2023; 195: 115 - 133.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Coração , Radiologistas , Assistência ao Paciente
7.
J Thorac Cardiovasc Surg ; 166(2): 422-431.e3, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34657715

RESUMO

OBJECTIVES: The study aim was to evaluate long-term results after anatomic restoration of the aortic root. METHODS: During an 18-year period, a total of 669 patients underwent valve-sparing root repair (aneurysm 554, dissection 115) using selective sinus replacement. None/trivial, mild, moderate, and severe (grades 3+ and 4+) insufficiency were present in 57, 146, 204, and 262 patients, respectively. RESULTS: The anatomic repair was adjusted to the existing aortic annulus diameter, which was 27.0 ± 3.0 mm on average. Replacement of 1, 2, or 3 sinuses of Valsalva was performed in 209, 234, and 226 patients, respectively. Altogether, 454 additional procedures on the cusps were performed, mostly as cusp patch plasty with pericardium (210). Thirty-day mortality was 0.6%. The mean follow-up duration was 7.1 ± 4.1 years (range, 0.01-19.1 years). The estimated freedom from relevant aortic insufficiency grade 3+ or greater (15 events) was 98% ± 1%, 97% ± 1%, and 94% ± 3% at 5, 10, and 15 years, respectively. On echocardiogram, no patient revealed a considerable change of the form or size of the repaired root, which was confirmed radiologically in 160 patients who received computed tomography angiography for any reason. Multivariate logistic regression analysis identified cusp prolapse/pseudo-prolapse as the only independent risk factor for the development of recurrent insufficiency grade 2+ or greater (41 occurrences), with a hazard ratio of 3.258 (95% confidence interval, 1.658-6.403; P = .001). An association between aortic annulus size and functional results could not be demonstrated. CONCLUSIONS: Patient-tailored root repair using isolated sinus replacement offers excellent functional long-term results regardless of underlying root pathology or annulus size. Aortic cusp pathology was decisive for long-term valve function.


Assuntos
Aorta Torácica , Insuficiência da Valva Aórtica , Humanos , Aorta Torácica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Resultado do Tratamento , Aorta/diagnóstico por imagem , Aorta/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/patologia , Prolapso , Estudos Retrospectivos
8.
J Cardiovasc Electrophysiol ; 33(10): 2174-2180, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35938384

RESUMO

INTRODUCTION: To investigate whether the current standard voltage cut-off of <0.5 for dense scar definition on endocardial bipolar voltage mapping (EBVM), using a high-resolution multipoint mapping catheter with microelectrodes (HRMMC), correctly identifies the actual scar area described on CT with myocardial thinning (CT MT). METHODS: Forty patients (39 men; 67.0 ± 9.0 y/o) with a history of transmural myocardial infarction (mean time interval since MI 15.0 ± 7.9 years) and sustained ventricular tachycardia (VT) were consecutively enrolled. A CT MT was performed in each patient before VT ablation. The CT MT 3D anatomical model, including MT layers, was merged with the 3D electroanatomical and EBVM. Different predefined cut-off settings for scar definition on EBVM were used to identify the optimal ones, which showed the best overlap in terms of scar area with the different MT layers. RESULTS: A cut-off value of <0.2 mV demonstrated the best correlation in terms of scar area with the 2 mm thinning on CT MT (p = .04) and a cut-off of <1 mV best overlapped with the 5 mm thinning (p = .003). The currently used <0.5 mV cut-off for scar definition on EBVM proved to be the best area correlation with 3 mm thinning (p = .0002). CONCLUSION: In order to better identify the real extent of scar areas after transmural MI as described on preprocedural CT MT, higher cut-off values for scar definition should be applied if the EBVM is performed using a HRMMC.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Catéteres , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Endocárdio , Humanos , Masculino , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Tomografia Computadorizada por Raios X
9.
Artigo em Inglês | MEDLINE | ID: mdl-35461710

RESUMO

OBJECTIVES: To evaluate the results after selective sinus replacement (SSR) for aortic root remodeling in bicuspid aortopathy. METHODS: Among 662 patients who underwent root repair using SSR between 2005 and 2020, there were 114 with bicuspid aortopathy. SSR was performed either as an isolated procedure (31) or as an adjunct to aortic valve repair (83) and was adjusted to the existing aortic annulus diameter rather than a downsized diameter. In valves with asymmetrical commissural orientation, the repair aimed for the achievement of a 180°-commissural orientation. RESULTS: Abolishment of aortic insufficiency (AI) ≥2+ using root repair alone was only possible in 2 patients with acute-dissection-related AI, yet isolated root repair was also performed in 29 further patients with no/mild AI. All remaining patients with AI ≥2+ presented cusp-related regurgitation and necessitated an additional valve repair. During the mean follow-up of 91 months (range, 13-196), a relevant valve defect (AI ≥3+ in 8, stenosis in 2) occurred in 10 patients (all after combined repair) resulting in an estimated freedom from a relevant aortic valve defect and/or reoperation of 96 ± 2%, 89 ± 4%, and 82 ± 6% at 5, 10, and 12 years, respectively. Echocardiographically, no patient revealed a considerable change of form or size of the repaired root nor was any root reintervention necessary. CONCLUSIONS: Patient-tailored root repair using SSR is a very effective and durable valve-sparing approach for bicuspid aortopathy. Aortic cusp repair is decisive for both abolishment of AI in bicuspid aortopathy and for the functional durability of the repaired aortic valve.

10.
Hellenic J Cardiol ; 65: 8-14, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35231607

RESUMO

OBJECTIVES: The PASCAL device is a transcatheter edge-to-edge repair system (TEER) for treatment of mitral regurgitation (MR). The PASCAL Ace as a newer version of the PASCAL device consists of a thinner profile without a spacer. The aim of the study was to examine the functional and hemodynamic outcome after TEER with the PASCAL Ace device in a real-world cohort. METHODS: Between September 2020 and August 2021, all consecutive patients with MR 3+/4+ treated percutaneously with PASCAL Ace were included in this study. Primary endpoints included successful device implantation, device success, improvement of exercise capacity, quality of life, and a composite of all-cause mortality, non-fatal stroke, myocardial infarction, new need for renal replacement therapy or severe bleeding at 30 days and 5 month. RESULTS: 49/66 patients had a functional etiology. Overall success rate was 98.5%. At follow-up, 84.7% of the patients had MR grade ≤ 1. TEER was associated with an improvement of LV ejection fraction (45% to 53%, p = 0.048). 86.5% were in NYHA class I or II. 6-minute-walking distance improved by 79m (p = 0.009). Kansas City Cardiomyopathy Questionnaire (KCCQ) improved by 19 points (p = 0.012). NT-proBNP levels decreased from 4832 to 2137 pg/dl (p = 0.003). Mean pulmonary capillary wedge pressures improved from 21 to 15mmHg (p = 0.001). At 5 month, a total of 3 patients died, none of cardiovascular cause. CONCLUSION: PASCAL Ace is safe and effective in treating MR, resulting in a sustained MR reduction, a reverse cardiac remodelling, improvement of exercise capacity, quality of life, NT-proBNP levels and hemodynamics at follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 33(5): 920-927, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35233883

RESUMO

INTRODUCTION: High power short duration (HPSD) ablation proved to be an effective and safe ablation technique for atrial fibrillation (AF). In former case series, a significant amount of postablation coagulation at the catheter tip as well as silent cerebral lesions (SCL) in postprocedural cerebral magnetic resonance (cMRI) have been identified in patients undergoing de-novo AF ablations with very high power 90 W short duration (vHPvSD) ablations using the QDot ablation catheter in combination with a novel RF generator (nGEN, Biosense Webster). Therefore, the RF generator software has been recently modified. METHODS AND RESULTS: Consecutive patients undergoing a first AF ablation including pulmonary vein isolation (PVI) with vHPvSD (90 W, with a predefined ablation time of 3 s at posterior left atrium (LA) wall sites and 4 s at other ablation sites) using the QDOT Micro ablation catheter (Biosense Webster) in conjunction with the technically modified nGEN RF generator (software V1c; Biosense Webster) were included. Procedural characteristics including first-pass isolation per pulmonary vein (PV) pair and early reconnection location within the 30-min waiting period were recorded. In all patients postablation endoscopy to document any thermal esophageal injury (EDEL) and in eligible patients a cMRI to detect silent cerebral events (SCEs)/lesions were performed. All acute procedure-related complications were recorded during the time until hospital discharge. Furthermore, short-term and midterm success after 3 and 6-12 months of follow-up was investigated. In total, 34 consecutive patients (67 ± 9 years; 62% male; 68% paroxysmal AF) were included. First-pass isolation of all PVs was achieved in 6/34 (18%) patients. First-pass isolation was seen in 37/68 (54%) of PV pairs. Early reconnection occurred in 11 (32%) patients (including reconnections at posterior LA wall sites n = 6 and at nonposterior sites n = 5). No patient had an EDEL (0%). In 6/23 (26%) patients undergoing postablation cerebral MRI SCEs were identified. In six patients, coagulation on the catheter tip was detected at the end of the procedure. No further peri- or postprocedural complications were detected. Early AF recurrence before discharge was seen in 1/34 (3%) of the patients included in this study. Within 3 months 10/34 (29%) revealed AF recurrence during blanking period. After a mean follow-up of 7 months, 31/34 (88%) patients revealed sinus rhythm. CONCLUSION: AF ablation using 90 W vHPvSD with a specialized ablation catheter in conjunction with a recently modified RF generator was associated with no EDEL in the whole study cohort and 26% SCEs in a subgroup of patients undergoing acute postablation cerebral MRI. Accordingly, to our previously published results, a relevant number of catheter tip coagulations was identified in this patient cohort even after modifications of the RF generator. The vHPvSD ablation technique using the present and the previous generator seems to be associated with a very low rate of esophageal injury. However, the recently revised generator software also produced a relevant number of catheter tip coagulum formation and SCEs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago , Feminino , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
12.
Eur Radiol ; 32(8): 5246-5255, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35267087

RESUMO

OBJECTIVES: To compare the use of coronary computed tomography angiography (CCTA) between academic and non-academic sites across Europe over the last decade. METHODS: We analyzed a large multicenter registry (ESCR MR/CT Registry) of stable symptomatic patients who received CCTA 01/2010-01/2020 at 47 (22%) academic and 165 (78%) non-academic sites across 19 European countries. We compared image quality, radiation dose, contrast-media-related adverse events, patient characteristics, CCTA findings, and downstream testing between academic and non-academic sites. RESULTS: Among 64,317 included patients (41% female; 60 ± 13 years), academic sites accounted for most cases in 2010-2014 (52%), while non-academic sites dominated in 2015-2020 (71%). Despite less contemporary technology, non-academic sites maintained low radiation doses (4.76 [2.46-6.85] mSv) with a 30% decline of high-dose scans ( > 7 mSv) over time. Academic and non-academic sites both reported diagnostic image quality in 98% of cases and low rate of scan-related adverse events (0.4%). Academic and non-academic sites examined similar patient populations (41% females both; age: 61 ± 14 vs. 60 ± 12 years; pretest probability for obstructive CAD: low 21% vs. 23%, intermediate 73% vs. 72%, high 6% both, CAD prevalence on CCTA: 40% vs. 41%). Nevertheless, non-academic sites referred more patients to non-invasive ischemia testing (6.5% vs. 4.2%) and invasive coronary angiography/surgery (8.5% vs. 5.6%). CONCLUSIONS: Non-academic and academic sites provide safe, high-quality CCTA across Europe, essential to successfully implement the recently updated guidelines for the diagnosis and management of chronic coronary syndromes. However, despite examining similar populations with comparable CAD prevalence, non-academic sites tend to refer more patients to downstream testing. KEY POINTS: • Smaller non-academic providers increasingly use CCTA to rule out obstructive coronary artery disease. • Non-academic and academic sites provide comparably safe, high-quality CCTA across Europe. • Compared to academic sites, non-academic sites tend to refer more patients to downstream testing.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Tomografia Computadorizada por Raios X
13.
Rofo ; 194(2): 181-191, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34384112

RESUMO

PURPOSE: In the light of the increasing importance of cardiovascular cross-sectional imaging in current guidelines, the goal of this study is to provide a comprehensive overview of cardiovascular imaging (CVI) offered by radiological institutions across Germany. MATERIALS AND METHODS: Data were extracted from the national certification program database of the German Roentgen Society (DRG) from 2015-2021. A nationwide online survey among radiology institutes (university hospitals, non-university hospitals, and private practices) was conducted for 2019, and data was extracted from the European Society of Cardiovascular Radiology (ESCR) registry. The data collection's key points included the number of centers and individuals certified for CVI, the number of cardiac CT and MRI examinations performed, the reporting habits, and the participation in the ESCR registry. RESULTS: 71 centers and 1278 persons, both with a substantial increase since 2015, were registered and certified by the DRG to perform CVI. According to the survey, a total of 69,286 CT and 64,281 MRI examinations were performed annually. Data from the survey and the ESCR registry indicated that reporting was mostly done solely by radiologists or, to a lesser degree, in joint consensus meetings with non-radiologists. The overall participation rate in the ESCR registry was 48 % among the survey's participants. CONCLUSION: This comprehensive analysis demonstrates that high-quality CVI by radiologists is available nationwide. The current challenges are to provide the best medical and technical quality of CVI by radiology for patient care and to ensure economic sustainability in the German health care system to accommodate the predicted substantial need for CVI in the future. KEY POINTS: · High-quality advanced CVI service by radiologists is available nationwide.. · Highly qualified specialist knowledge is widely represented from university to private practices.. · Certification programs successfully contribute to the dissemination & deepening of CVI expertise.. · The ESCR registry is an established international tool for the documentation of CVI.. CITATION FORMAT: · Sieren M, Maintz D, Gutberlet M et al. Current Status of Cardiovascular Imaging in Germany: Structured Data from the National Certification Program, ESCR Registry, and Survey among Radiologists. Fortschr Röntgenstr 2022; 194: 181 - 191.


Assuntos
Radiologia , Certificação , Alemanha , Humanos , Imageamento por Ressonância Magnética/métodos , Radiologistas , Sistema de Registros
14.
Artigo em Inglês | MEDLINE | ID: mdl-34655759

RESUMO

INTRODUCTION: Aim of this study was to evaluate efficacy and safety of ventricular tachycardia (VT) catheter ablation in patients with structural heart disease (SHD) in relation to the presence of an intramural septal substrate. METHODS: Consecutive patients undergoing VT ablation between January 2019 and October 2020 were included. All patients were stratified based on the presence of relevant septal substrate and freedom from VT recurrences were analyzed. RESULTS: In total, 199 consecutive patients (64.2 ± 13.0 years; 89% male; 55% ischemic cardiomyopathy (ICM)) undergoing VT ablation were included. 129/199 patients (65%) showed significant septal substrate (55/90 patients (61%) with non-ischemic cardiomyopathy (NICM) compared to 74/109 patients (68%) with ICM; p = 0.37). Acute procedural success with elimination of all inducible VTs was achieved in 66/70 patients (94%) without and in 103/129 patients (80%) with a septal substrate (p = 0.007). In the cohort including patients with a clinical FU, 15/60 patients (25%) without a septal substrate and 48/123 patients (39%) with a septal substrate experienced VT recurrence during a FU of 8.1 ± 5.9 months (p = 0.069). CONCLUSION: Presence of septal VT substrate in patients with a structural heart disease or coronary artery disease is common. Acute success of VT catheter ablation was significantly higher and mid-term success tended to be higher in patients without a septal substrate.

15.
Europace ; 24(3): 400-405, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34757432

RESUMO

AIMS: Very high-power short-duration (vHPSD) via temperature-controlled ablation (TCA) is a new modality to perform radiofrequency pulmonary vein isolation (PVI), conceivably at the cost of a narrower safety margin towards the oesophagus. In this two-centre trial, we aimed to determine the safety of vHPSD-based PVI with specific emphasis on silent oesophageal injury. METHODS AND RESULTS: Ninety consecutive patients with atrial fibrillation (AF) underwent vHPSD-PVI (90 W, 3-4 s, TCA) using the QDOT MICRO catheter, in conjunction with the nGEN (Bad Neustadt, n = 45) or nMARQ generator (Bruges, n = 45). All patients underwent post-ablation oesophageal endoscopy. Procedural parameters and complications were recorded. A subgroup of 21 patients from Bad Neustadt underwent cerebral magnetic resonance imaging (cMRI) to detect silent cerebral events (SCEs). Mean age was 67 ± 9 years, 59% patients were male, and 66% patients had paroxysmal AF. Pulmonary vein isolation was obtained in all cases after 96 ± 29 min. No steam pop, cardiac tamponade, stroke, or fistula was reported. None of the 90 patients demonstrated oesophageal ulceration (0%). Charring was not observed in the nMARQ cohort (0% vs. 11% in the nGEN group). In 5 out of 21 patients (24%), cMRI demonstrated SCE (exclusively nGEN cohort). CONCLUSION: Temperature-controlled vHPSD catheter ablation allows straightforward PVI without evidence of oesophageal ulcerations or symptomatic complications. Catheter tip charring and silent cerebral lesions when using the nGEN generator have led to further modification.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago/lesões , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento
16.
Herzschrittmacherther Elektrophysiol ; 32(4): 471-474, 2021 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-34714388

RESUMO

A young woman presented with palpitations. Holter monitoring revealed frequent premature ventricular complexes; echocardiography showed high-degree mitral regurgitation due to mitral valve prolapse. While mitral valve replacement or repair were being discussed, a different therapy was applied after further diagnostic work-up of the patient which in retrospect appears even more efficient.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Adulto , Arritmias Cardíacas , Ecocardiografia , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico , Prolapso da Valva Mitral/cirurgia , Adulto Jovem
17.
J Cardiol ; 78(6): 577-585, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34479788

RESUMO

BACKGROUND: The PASCAL system (Edwards Lifescience, Irvine, CA, USA) is a novel device for edge-to-edge treatment of mitral regurgitation (MR). The aim of our study was to examine the functional and hemodynamic outcome after repair of functional (FMR) and degenerative mitral regurgitation (DMR) using the PASCAL system in a real-world setting. METHODS: A total 92 consecutive patients with symptomatic MR 3+/4+ were treated in our institute using the PASCAL device. Primary endpoints included procedural success, clinical success, and major adverse event rate at 30 days and 7 months. RESULTS: 68.5% had a functional and 31.5% a degenerative etiology. Overall success rate was achieved in 97.8% patients (98.4% FMR, 96.6% DMR). At follow-up, 85.7% of the patients (89.2% FMR, 78.3% DMR) had MR grade ≤ 1. 96.4% (97.4% FMR, 94.4% DMR) were in New York Heart Association class I or II. Six-minute walking distance improved by 96 m (92 m FMR, 106 m DMR), Kansas City Cardiomyopathy Questionnaire improved by 19 points (19 points FMR, 19 points DMR). Pro-B-type natriuretic peptide (proBNP) levels decreased from 4673 to 2179 pg/dl (5239-2018 pg/ml FMR, 3418-2530 pg/ml DMR) and mean pulmonary capillary wedge pressure from 21 to 16 mmHg (21-17 mmHg FMR, 19-13 mmHg DMR). At 30 days, there was 1 cardiovascular death (1.2%) with DMR. At 1 year, Kaplan-Meier survival was 86% (86% FMR, 86% DMR). CONCLUSIONS: Severe MR can successfully and safely be treated with the PASCAL device regardless of etiologies. This interventional approach resulted in a sustained MR reduction, improvement in exercise capacity, quality of life, proBNP levels, and hemodynamics in FMR and DMR at follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento
18.
Clin Neuroradiol ; 31(4): 901-909, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34379134

RESUMO

PURPOSE: The most common protocols in the initial diagnostic of acute ischemic stroke do not assess cardiogenic or aortic causes of embolism. These are usually evaluated later by transthoracic (TTE) or transesophageal (TEE) echocardiography. This study aimed to evaluate the feasibility of a diagnostic tool for thoracic cardiovascular thrombi according to the first experience with a new extended cardio-stroke protocol (Big 5-Jena eCS protocol) in acute stroke patients. METHODS: Retrospective analyses of the tomography scans database of the Jena University Hospital were performed. We included a total of 67 patients in the feasibility analyses, based on the evaluation of three outcomes. RESULTS: Primary outcome: the Big 5-Jena eCS protocol was able to detect thoracic cardiovascular thrombi in a total of 20 patients in different locations including the arch of the aorta, the aortic valve, the left atrium, the left atrial appendage, the left ventricle, and the pulmonary arteries. Secondary outcome: implementating the protocol did not result in a significant elevation of the radiation exposure compared to traditional protocols. Tertiary outcome: the new protocol identified seven cases that were considered negative by echocardiography. CONCLUSION: The implementation of an extended cardio-stroke protocol is feasible, no significantly time-consuming, acquiring assessable imaging, and maintaining radiation exposure acceptable. The Big 5-Jena eCS protocol was also able to detect some thrombi not reported by TTE or TEE; however, due to our data's explorative character, a conclusive comparison with cardiac ultrasound is not possible. A prospective pilot study and clinical trials should be conducted to assess the diagnostic accuracy of this protocol compared to echocardiography and determine the potential impact on diagnostic and treatment decisions.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Handchir Mikrochir Plast Chir ; 53(3): 224-230, 2021 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-34134154

RESUMO

Clinical signs of an infection of the hand can be subtle initially or in a chronic state. But even in a progressive stadium it might be difficult to define an involvement of soft tissue, joint or bone. This review article addresses the diagnostic options of radiologic imaging. Radiographs of the affected region are the basic diagnostics. Sonographics provides information about an abscess or effusion versus diffuse edema and phlegmon. Both are in most situations promptly available. In chronic cases and unclear findings, MRI is of value. With bone involvement and an implant related osteomyelitis suspected, CT is the most valid method.


Assuntos
Osteomielite , Abscesso/diagnóstico por imagem , Osso e Ossos , Mãos/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Osteomielite/diagnóstico por imagem
20.
Clin Res Cardiol ; 110(5): 628-639, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32845361

RESUMO

AIMS: To examine the functional and hemodynamic mid-term outcome at 5 months of mitral regurgitation (MR) reduction using the PASCAL repair system. METHODS AND RESULTS: Between July 2019 and February 2020 31 consecutive patients with MR 3 +/4 + (mean age 77.5 years, all in New York Heart Association (NYHA) class III-IV, STS score 9.1 ± 7.4) underwent MR reduction in our institute using the PASCAL device. 61.3% had a functional, 29.0% a degenerative, and 9.7% a mixed etiology. Successful implantation was achieved in 30/31 (96.8%) patients. 27/31 patients (87.1%) completed 5-month follow-up with clinical, echocardiographic, laboratory and hemodynamic assessment. At 5 months, 70.4% of the patients had MR grade ≤ 1 (p < 0.001). 85.2% were in NYHA class I or II (p < 0.001). Six-minute walk distance improved by 145 m (p = 0.010), Kansas City cardiomyopathy questionnaire and European quality of life 5 dimensions questionnaire (EQ5D) improved by 31 (p < 0.001) and 9 points (p = 0.001), respectively. Mean pulmonary capillary wedge pressure decreased significantly from 22.1 ± 9 mmHg to 17.3 ± 8 mmHg (p = 0.041) and right atrial pressure from 10.3 ± 6 mmHg to 8.0 ± 6 mmHg (p = 0.013) from baseline to 5 months. In addition, propensity score matching showed that PASCAL and MitraClip procedures resulted in equally hemodynamic and functional improvement. CONCLUSION: MR reduction of severe MR with the PASCAL device is feasible and safe regardless of etiologies. Mid-term follow-up at 5 months showed a sustained MR reduction, improvement of exercise capacity, quality of life, proBNP levels and hemodynamics regarding pulmonary capillary wedge pressure and right atrial pressure.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Arterial/fisiologia , Tolerância ao Exercício , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Pressão Propulsora Pulmonar/fisiologia , Qualidade de Vida , Inquéritos e Questionários