Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 66(24)2021 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-34847532

RESUMO

Accurate knowledge of the exact stopping location of ions inside the patient would allow full exploitation of their ballistic properties for patient treatment. The localized energy deposition of a pulsed particle beam induces a rapid temperature increase of the irradiated volume and leads to the emission of ionoacoustic (IA) waves. Detecting the time-of-flight (ToF) of the IA wave allows inferring information on the Bragg peak location and can henceforth be used forin-vivorange verification. A challenge for IA is the poor signal-to-noise ratio at clinically relevant doses and viable machines. We present a frequency-based measurement technique, labeled as ionoacoustic tandem phase detection (iTPD) utilizing lock-in amplifiers. The phase shift of the IA signal to a reference signal is measured to derive theToF. Experimental IA measurements with a 3.5 MHz lead zirconate titanate (PZT) transducer and lock-in amplifiers were performed in water using 22 MeV proton bursts. A digital iTPD was performedin-silicoat clinical dose levels on experimental data obtained from a clinical facility and secondly, on simulations emulating a heterogeneous geometry. For the experimental setup using 22 MeV protons, a localization accuracy and precision obtained through iTPD deviates from a time-based reference analysis by less than 15µm. Several methodological aspects were investigated experimentally in systematic manner. Lastly, iTPD was evaluatedin-silicofor clinical beam energies indicating that iTPD is in reach of sub-mm accuracy for fractionated doses < 5 Gy. iTPD can be used to accurately measure theToFof IA signals online via its phase shift in frequency domain. An application of iTPD to the clinical scenario using a single pulsed beam is feasible but requires further development to reach <1 Gy detection capabilities.


Assuntos
Acústica , Terapia com Prótons , Humanos , Íons , Terapia com Prótons/métodos , Prótons , Transdutores
2.
Med Phys ; 42(2): 567-74, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25652477

RESUMO

PURPOSE: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. METHODS: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. RESULTS: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10(12) eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 µm and agreed with Geant4 simulations to better than 100 µm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. CONCLUSIONS: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound imaging. This acoustic range verification approach could offer the possibility of combining anatomical ultrasound and Bragg peak imaging, but further studies are required for translation of these findings to clinical application.


Assuntos
Acústica , Terapia com Prótons , Radioterapia Guiada por Imagem/métodos , Método de Monte Carlo , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/instrumentação , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...