Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 6714, 2019 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-31040311

RESUMO

The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a refinement of the ionoacoustic approach. With its capability of completely monitoring a single, focused proton bunch with prompt readout and high repetition rate, I-BEAT is a promising approach to meet future requirements of experiments and applications in the field of laser-based ion acceleration. We demonstrate its functionality at two laser-driven ion sources for quantitative online determination of the kinetic energy distribution in the focus of single proton bunches.

2.
Rev Sci Instrum ; 89(12): 123302, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30599609

RESUMO

A common approach for spectrum determination of polyenergetic proton bunches from laser-ion acceleration experiments is based on the time-of-flight (TOF) method. However, spectra obtained using this method are typically given in relative units or are estimated based on some prior assumptions on the energy distribution of the accelerated ions. In this work, we present a new approach using the TOF method that allows for an absolute energy spectrum reconstruction from a current signal acquired with a sub-nanosecond fast and 10 µm thin silicon detector. The reconstruction is based on solving a linear least-squares problem, taking into account the response function of the detection system. The general principle of signal generation and spectrum reconstruction by setting up an appropriate system response matrix is presented. Proof-of-principle experiments at a 12 MV Tandem accelerator using different nanosecond-short (quasi-)monoenergetic and polyenergetic proton bunches at energies up to 20 MeV were successfully performed. Within the experimental uncertainties of 2.4% and 12.1% for energy and particle number, respectively, reconstructed energy distributions were found in excellent agreement with the spectra calculated using Monte Carlo simulations and measured by a magnetic spectrometer. This TOF method can hence be used for absolute online spectrometry of laser-accelerated particle bunches.

3.
Phys Med Biol ; 62(17): L20-L30, 2017 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-28742053

RESUMO

Proton ranges in water between 145 MeV to 227 MeV initial energy have been measured at a clinical superconducting synchrocyclotron using the acoustic signal induced by the ion dose deposition (ionoacoustic effect). Detection of ultrasound waves was performed by a very sensitive hydrophone and signals were stored in a digital oscilloscope triggered by secondary prompt gammas. The ionoacoustic range measurements were compared to existing range data from a calibrated range detector setup on-site and agreement of better than 1 mm was found at a Bragg peak dose of about 10 Gy for 220 MeV initial proton energy, compatible with the experimental errors. Ionoacoustics has thus the potential to measure the Bragg peak position with submillimeter accuracy during proton therapy, possibly correlated with ultrasound tissue imaging.


Assuntos
Acústica , Ciclotrons/instrumentação , Terapia com Prótons , Água/química , Calibragem , Humanos
4.
Sci Rep ; 6: 29305, 2016 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-27384505

RESUMO

Ions provide a more advantageous dose distribution than photons for external beam radiotherapy, due to their so-called inverse depth dose deposition and, in particular a characteristic dose maximum at their end-of-range (Bragg peak). The favorable physical interaction properties enable selective treatment of tumors while sparing surrounding healthy tissue, but optimal clinical use requires accurate monitoring of Bragg peak positioning inside tissue. We introduce ionoacoustic tomography based on detection of ion induced ultrasound waves as a technique to provide feedback on the ion beam profile. We demonstrate for 20 MeV protons that ion range imaging is possible with submillimeter accuracy and can be combined with clinical ultrasound and optoacoustic tomography of similar precision. Our results indicate a simple and direct possibility to correlate, in-vivo and in real-time, the conventional ultrasound echo of the tumor region with ionoacoustic tomography. Combined with optoacoustic tomography it offers a well suited pre-clinical imaging system.


Assuntos
Íons/química , Ultrassonografia/métodos , Animais , Humanos , Camundongos , Camundongos Nus , Fótons , Prótons , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...