Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Radiol ; 76(1): 73.e1-73.e19, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31883615

RESUMO

For surgical aortic valve replacement, the Society of Thoracic Surgeons score (STSS) is the reference standard for the prediction of operative risk. In transcatheter aortic valve implantation (TAVI) though, where the procedure itself is minimally invasive, the traditional risk assessment is supplemented by CTA. Through a consistent approach to the acquisition of high-quality images and the standardised reporting of annular measurements and adverse root and vascular features, patients at risk of complications can be identified. In turn, this may allow for a personalised procedural approach and treatment strategies devised to potentially reduce or mitigate this risk. This article provides a systematic and standardised approach to pre-procedural work-up with computed tomography angiography (CTA) and explores the current state of evidence and future areas of development in this rapidly developing field.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Substituição da Valva Aórtica Transcateter , Humanos , Medição de Risco
2.
J Cardiovasc Comput Tomogr ; 14(1): 60-67, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31302028

RESUMO

BACKGROUND: Scan quality can have a significant effect on the diagnostic performance of non-invasive imaging techniques. However, the extent of its influence has scarcely been investigated in a head-to-head manner. METHODS: Two-hundred and eight patients underwent CCTA, SPECT, and PET prior to invasive fractional flow reserve measurements. Scan quality was classified as either good, moderate, or poor. RESULTS: Distribution of good, moderate, and poor quality scans was; CCTA; 66%, 22%, 13%; SPECT; 52%, 38%, 9%; PET; 86%, 13%, 1%. Good quality CCTA scans possessed a higher specificity (75% vs. 31%, p = 0.001), positive predictive value (PPV, 71% vs. 51%, p = 0.050), and accuracy (80% vs. 60%, p = 0.009) compared to moderate quality scans, while sensitivity (94%) and negative predictive value (NPV, 88%) were similar to moderate and poor quality scans. Sensitivity (76%), NPV (84%), and accuracy (85%) of good quality SPECT scans was superior to those of moderate (41% p = 0.001, 56% p = 0.010, 70% p = 0.010) and poor quality (30% p = 0.003, 65% p = 0.069, 63% p = 0.038). Specificity (92%) and PPV (87%) of good quality SPECT scans did not differ from scans of diminished quality. Good quality PET scans exhibited high sensitivity (84%), specificity (86%), NPV (88%), PPV (81%) and accuracy (85%), which was comparable to scans of lesser quality. Good quality CCTA, SPECT, and PET scans demonstrated a similar diagnostic accuracy (p = 0.247). CONCLUSION: Diagnostic performance of CCTA, and SPECT is hampered by scan quality, while the diagnostic value of PET is not affected. Good quality CCTA, SPECT, and PET scans possess a high diagnostic accuracy.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Data Brief ; 27: 104584, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31687432

RESUMO

Scan quality directly impacts the diagnostic performance of non-invasive imaging modalities as reported in a substudy of the PACIFC-trial: "Impact of Scan Quality on the Diagnostic Performance of CCTA, SPECT, and PET for Diagnosing Myocardial Ischemia Defined by Fractional Flow Reserve" [1]. This Data-in-Brief paper supplements the hereinabove mentioned article by presenting the diagnostic performance of CCTA, SPECT, and PET on a per vessel level for the detection of hemodynamic significant coronary artery disease (CAD) when stratified according to scan quality and vascular territory.

4.
J Cardiovasc Comput Tomogr ; 13(4): 179-187, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31302027

RESUMO

BACKGROUND: A diminished coronary lumen volume to left ventricle mass ratio (V/M) derived from coronary computed tomography angiography (CCTA) has been proposed as factor contributing to impaired myocardial blood flow (MBF) even in the absence of obstructive disease on invasive coronary angiography (ICA). METHODS: Patients underwent CCTA, and positron emission tomography (PET) prior to ICA. Matched global V/M, global, and vessel specific hyperaemic MBF (hMBF), coronary flow reserve (CFR), and, FFR were available for 431 vessels in 152 patients. The median V/M (20.71 mm3/g) was used to divide the population into patients with either a low V/M or a high V/M. RESULTS: Overall, a higher percentage of vessels with an abnormal hMBF and FFR (34% vs. 19%, p = 0.009 and 20% vs. 9%, p = 0.004), as well as a lower FFR (0.93 [interquartile range: 0.85-0.97] vs. 0.95 [0.89-0.98], p = 0.016) values were observed in the low V/M group. V/M was weakly associated with vessel specific hMBF (R = 0.148, p = 0.027), and FFR (R = 0.156, p < 0.001). Among vessels with non-obstructive CAD on ICA (361 vessels), no association between V/M and vessel specific hMBF nor CFR was noted. However, in the absence of obstructive CAD, V/M was associated with (R = 0.081, p = 0.027), and independently predictive for FFR (p = 0.047). CONCLUSION: Overall, an abnormal vessel specific hMBF and FFR were more prevalent in patients with a low V/M compared to those with a high V/M. Furthermore, V/M was weakly associated with vessel specific hMBF and FFR. In the absence of obstructive CAD on ICA, V/M was weakly associated with notwithstanding independently predictive for FFR.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Ventrículos do Coração/diagnóstico por imagem , Idoso , Ensaios Clínicos como Assunto , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
5.
Eur J Nucl Med Mol Imaging ; 45(7): 1091-1100, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29470616

RESUMO

PURPOSE: Traditionally, interpretation of myocardial perfusion imaging (MPI) is based on visual assessment. Computer-based automated analysis might be a simple alternative obviating the need for extensive reading experience. Therefore, the aim of the present study was to compare the diagnostic performance of automated analysis with that of expert visual reading for the detection of obstructive coronary artery disease (CAD). METHODS: 206 Patients (64% men, age 58.2 ± 8.7 years) with suspected CAD were included prospectively. All patients underwent 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) and invasive coronary angiography with fractional flow reserve (FFR) measurements. Non-corrected (NC) and attenuation-corrected (AC) SPECT images were analyzed both visually as well as automatically by commercially available SPECT software. Automated analysis comprised a segmental summed stress score (SSS), summed difference score (SDS), stress total perfusion deficit (S-TPD), and ischemic total perfusion deficit (I-TPD), representing the extent and severity of hypoperfused myocardium. Subsequently, software was optimized with an institutional normal database and thresholds. Diagnostic performances of automated and visual analysis were compared taking FFR as a reference. RESULTS: Sensitivity did not differ significantly between visual reading and most automated scoring parameters, except for SDS, which was significantly higher than visual assessment (p < 0.001). Specificity, however, was significantly higher for visual reading than for any of the automated scores (p < 0.001 for all). Diagnostic accuracy was significantly higher for visual scoring (77.2%) than for all NC images scores (p < 0.05), but not compared with SSS AC and S-TPD AC (69.8% and 71.2%, p = 0.063 and p = 0.134). After optimization of the automated software, diagnostic accuracies were similar for visual (73.8%) and automated analysis. Among the automated parameters, S-TPD AC showed the highest accuracy (73.5%). CONCLUSION: Automated analysis of myocardial perfusion SPECT can be as accurate as visual interpretation by an expert reader in detecting significant CAD defined by FFR.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Automação , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Prev Med ; 67: 199-203, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25091878

RESUMO

OBJECTIVE: Excess liver fat (LF) is associated with dyslipidemia, insulin resistance and cardiovascular disease. Evidence suggests that there is an independent relationship between physical activity (PA) and LF although little is known of the role of PA intensity in reducing LF. The purpose was to evaluate whether meeting PA guidelines, the amount of PA and the intensity of PA at baseline were associated with LF after five-years. METHODS: Men and women (n=478) living in Vancouver, Canada of Aboriginal, Chinese, European or South Asian background completed baseline measurements in 2004-2005. Liver fat was assessed using CT scans at 5-year follow-up, and PA using a PA questionnaire at baseline as well as demographics and anthropometry. RESULTS: In separate unadjusted models, meeting moderate-vigorous PA (MVPA) guidelines (p=0.009), vigorous PA (p=0.002) and MVPA (p=0.017) but not moderate PA (p=0.068) was predictive of LF at five years (p=0.009). In multiple linear regression models, when adjusted for covariates, meeting MVPA guidelines and MVPA with LF at five years was no longer significant (p>0.05) while vigorous PA remained significant (p=0.021). CONCLUSION: Meeting PA guidelines through MVPA may not be adequate to prevent the accumulation of LF and PA guidelines may require revision. Vigorous PA should be encouraged to prevent LF accumulation.


Assuntos
Exercício Físico/fisiologia , Fígado Gorduroso/etnologia , Adulto , Antropometria , Colúmbia Britânica , Doenças Cardiovasculares/prevenção & controle , Fígado Gorduroso/fisiopatologia , Fígado Gorduroso/prevenção & controle , Feminino , Seguimentos , Humanos , Resistência à Insulina , Masculino , Pessoa de Meia-Idade , Obesidade/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...