Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Endovasc Ther ; : 15266028231165731, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37073926

RESUMO

PURPOSE: The aim of this study was to assess the initial experience, technical success, and clinical benefit of AneuFix (TripleMed, Geleen, the Netherlands), a novel biocompatible and non-inflammatory elastomer that is directly injected into the aneurysm sac by a translumbar puncture in patients with a type II endoleak and a growing aneurysm. MATERIALS AND METHODS: A multicenter, prospective, pivotal study was conducted (ClinicalTrials.gov:NCT02487290). Patients with a type II endoleak and aneurysm growth (>5 mm) were included. Patients with a patent inferior mesenteric artery connected to the endoleak were excluded for initial safety reasons. The endoleak cavity was translumbar punctured with cone-beam computed tomography (CT) and software guidance. Angiography of the endoleak was performed, all lumbar arteries connected to the endoleak were visualized, and AneuFix elastomer was injected into the endoleak cavity and short segment of the lumbar arteries. The primary endpoint was technical success, defined as successful filling of the endoleak cavity with computed tomography angiography (CTA) assessment within 24 hours. Secondary endpoints were clinical success defined as the absence of abdominal aortic aneurysm (AAA) growth at 6 months on CTA, serious adverse events, re-interventions, and neurological abnormalities. Computed tomography angiography follow-up was performed at 1 day and at 3, 6, and 12 months. This analysis reports the initial experience of the first 10 patients treated with AneuFix. RESULTS: Seven men and 3 women with a median age of 78 years (interquartile range (IQR), 74-84) were treated. Median aneurysm growth after endovascular aneurysm repair (EVAR) was 19 mm (IQR, 8-23 mm). Technical success was 100%; it was possible to puncture the endoleak cavity of all treated patients and to inject AneuFix. Clinical success at 6 months was 90%. One patient showed 5 mm growth with persisting endoleak, probably due to insufficient endoleak filling. No serious adverse events related to the procedure or AneuFix material were reported. No neurological disorders were reported. CONCLUSION: The first results of type II endoleak treatment with AneuFix injectable elastomer in a small number of patients with a growing aneurysm show that it is technically feasible, safe, and clinically effective at 6 months. CLINICAL IMPACT: Effective and durable embolization of type II endoleaks causing abdominal aortic aneurysms (AAA) growth after EVAR is challenging. A novel injectable elastic polymer (elastomer) was developed, specifically designed to treat type II endoleaks (AneuFix, TripleMed, Geleen, the Netherlands). Embolization of the type II endoleak was performed by translumbar puncture. The viscosity changes from paste-like during injection, into an elastic implant after curing. The initial experience of this multicentre prospective pivotal trial demonstrated that the procedure is feasible and safe with a technical success of 100%. Absence of AAA growth was observed in 9 out of 10 treated patients at 6 months.

2.
Int J Comput Assist Radiol Surg ; 18(8): 1533-1541, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36719561

RESUMO

PURPOSE: Image fusion merges preoperative computed tomography angiography (CTA) with live fluoroscopy during endovascular procedures to function as an overlay 3D roadmap. However, in most current systems, the registration between imaging modalities is performed manually by vertebral column matching which can be subjective, inaccurate and time consuming depending on experience. Our objective was to evaluate feasibility and accuracy of image-based automated 2D-3D image fusion between preoperative CTA and intraoperative fluoroscopy based on vertebral column matching. METHODS: A single-center study with offline procedure data was conducted in 10 consecutive patients which had endovascular aortic repair in which we evaluated unreleased automated fusion software provided by Philips (Best, the Netherlands). Fluoroscopy and digital subtraction angiography images were collected after the procedures and the vertebral column was fused fully automatically. Primary endpoints were feasibility and accuracy of bone alignment (mm). Secondary endpoint was vascular alignment (mm) between the lowest renal artery orifices. Clinical non-inferiority was defined at a mismatch of < 1 mm. RESULTS: In total, 87 automated measurements and 40 manual measurements were performed on vertebrae T12-L5 in all 10 patients. Manual correction was needed in 3 of the 10 patients due to incomplete visibility of the vertebral edges in the fluoroscopy image. Median difference between automated fusion and manual fusion was 0.1 mm for bone alignment (p = 0.94). The vascular alignment was 4.9 mm (0.7-17.5 mm) for manual and 5.5 mm (1.0-14.0 mm) for automated fusion. This did not improve, due to the presence of stiff wires and stent graft. CONCLUSION: Automated image fusion was feasible when all vertebral edges were visible. Accuracy was non-inferior to manual image fusion regarding bone alignment. Future developments should focus on intraoperative image-based correction of vascular alignment.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Procedimentos Endovasculares/métodos , Estudos de Viabilidade , Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia , Imageamento Tridimensional/métodos , Resultado do Tratamento
3.
Eur J Vasc Endovasc Surg ; 65(3): 398-404, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36343749

RESUMO

OBJECTIVE: Regular measurement of fibrinogen as dose guidance in catheter directed thrombolysis (CDT) for acute limb ischaemia (ALI) has recently been dropped from European guidelines based on inconsistent literature. This study aimed to determine whether low fibrinogen levels and high activated partial thromboplastin time (APTT) are associated with an increased major bleeding risk during CDT. METHODS: All consecutive patients treated with CDT for ALI in two Dutch hospitals between January 2004 and April 2021 were analysed retrospectively. Patients were treated with two dosing regimens (low dose: 50 000 IU/hour; high dose: 100 000 IU/hour) of urokinase and, after 2018, with a single low dose regimen of alteplase (rtPA) due to urokinase manufacturing problems. The incidence of major bleeding and associated APTT and fibrinogen levels were reviewed from patient charts. RESULTS: Of the 443 included cases, 277 underwent CDT with urokinase and 166 with rtPA. The incidence of major bleeding in the whole cohort was 7%. Patients with a fibrinogen levels < 1.0 g/L developed more major bleeding than those in whom the fibrinogen level did not drop below 1.0 g/L (15% vs. 6%; p = .041). Systemic heparinisation during CDT or high (> 80 seconds) APTT were not significantly associated with major bleeding. Angiographic success (47% vs. 72%; p = .003) and 30 day amputation free survival (53% vs. 82%; p < .001) were lower for cases with major bleeding. Older age (odds ratio [OR] 1.06, 95% confidence interval [CI] 1.02 - 1.11), cardiac history (OR 3.35, 95% CI 1.39 - 8.06), high dose regimens (≥ 75 000 IU/hour urokinase; OR 2.67, 95% CI 1.18 - 6.04), and fibrinogen values < 1.0 g/L (OR 5.59, 95% CI 1.98 - 15.77) were independent predictors for major bleeding during CDT. CONCLUSION: High dose thrombolytic regimens and fibrinogen levels of ≤ 1.0 g/L are associated with more major bleeding during thrombolytic therapy. Major bleeding significantly worsened the clinical outcome. A prospective comparative study is needed to assess the benefit of monitoring fibrinogen levels.


Assuntos
Arteriopatias Oclusivas , Doenças Vasculares Periféricas , Humanos , Ativador de Plasminogênio Tipo Uroquinase , Estudos Retrospectivos , Estudos Prospectivos , Terapia Trombolítica/efeitos adversos , Fibrinolíticos , Ativador de Plasminogênio Tecidual , Arteriopatias Oclusivas/etiologia , Isquemia/etiologia , Hemorragia/etiologia , Doenças Vasculares Periféricas/complicações , Fibrinogênio , Tomada de Decisão Clínica , Resultado do Tratamento
4.
EJVES Vasc Forum ; 55: 38-41, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35497326

RESUMO

Introduction: Endovascular treatment of an aortic stump rupture is technically feasible. Whether this is a definitive treatment or a bridge to further surgery is unknown. Report: Previously a Case of an aortic stump rupture following extra-anatomic repair of a recurrent aortoduodenal fistula (ADF), which was successfully treated endovascularly by placement of an Amplatzer® Vascular Plug was described. The patient survived this acute procedure, but four years later was admitted with fever and back pain. Imaging revealed progressive enlargement of the aortic stump. A re-exploration was performed with removal of the infected aortic stump including the Amplatzer plug. A new aortic stump was created together with resection of an adherent part of the duodenum. The patient was discharged after five months and was able to survive for two more years without any recurring vascular complications. Discussion: This Case demonstrates that after four years, endovascular treatment was not a definitive treatment for aortic stump rupture. Endovascular treatment should be followed by definitive treatment when the patient is fit for surgery, especially in cases of ADF. If the patient is unfit for surgery, conservative treatment with culture based antibiotics is a reasonable alternative. Positive obstinacy lengthened the survival of this patient with eight years of reasonably good quality life.

5.
Eur J Vasc Endovasc Surg ; 62(3): 463-468, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34303599

RESUMO

OBJECTIVE: Acute peripheral arterial occlusions can be treated by catheter directed thrombolysis (CDT). However, CDT is time consuming and accompanied by the risk of bleeding complications. The addition of contrast enhanced ultrasound and microbubbles could improve thrombus susceptibility to thrombolytic agents and potentially shorten treatment time with a lowered risk of bleeding complications. This article reports the outcomes of the safety and feasibility of this novel technique. METHODS: In this single arm phase II trial, 20 patients with acute lower limb ischaemia received CDT combined with an intravenous infusion of microbubbles and locally applied ultrasound during the first hour of standard intra-arterial thrombolytic therapy. The primary endpoint was safety, i.e., occurrence of serious adverse events (haemorrhagic complications and/or amputation) and death within one year. Secondary endpoints included angiographic and clinical success, thrombolysis duration, additional interventions, conversion, and quality of life. RESULTS: The study included 20 patients (16 men; median age 68.0 years; range, 50.0 - 83.0; and 40% native artery and 60% bypass graft). In all patients, the use of microbubble contrast enhanced sonothrombolysis could be applied successfully. There were no serious adverse events related to the experimental treatment. Duplex examination showed flow distal from the occlusion after 23.1 hours (range 3.1 - 46.5) with a median thrombolysis time of 47.5 hours (range 6.0 - 81.0). The short term ABI and pain scores significantly improved; however, no changes were observed before or after thrombolysis in the microcirculation. Overall mortality and amputation rates were both 2% within one year. The one year patency rate was 55%. CONCLUSION: Treatment of patients with acute peripheral arterial occlusions with contrast enhanced sonothrombolysis is feasible and safe to perform in patients. Further research is necessary to investigate the superiority of this new treatment over standard treatment.


Assuntos
Fibrinolíticos/administração & dosagem , Isquemia/terapia , Microbolhas , Doença Arterial Periférica/terapia , Terapia Trombolítica , Terapia por Ultrassom , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Masculino , Microbolhas/efeitos adversos , Pessoa de Meia-Idade , Países Baixos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Terapia Trombolítica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos , Grau de Desobstrução Vascular
6.
J Endovasc Ther ; 28(1): 78-92, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32964768

RESUMO

PURPOSE: To determine if image fusion will reduce contrast volume, radiation dose, and fluoroscopy and procedure times in standard and complex (fenestrated/branched) endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: A search of the PubMed, Embase, and Cochrane databases was performed in December 2019 to identify articles describing results of standard and complex EVAR procedures using image fusion compared with a control group. Study selection, data extraction, and assessment of the methodological quality of the included publications were performed by 2 reviewers working independently. Primary outcomes of the pooled analysis were contrast volume, fluoroscopy time, radiation dose, and procedure time. Eleven articles were identified comprising 1547 patients. Data on 140 patients satisfying the study inclusion criteria were added from the authors' center. Mean differences (MDs) are presented with the 95% confidence interval (CI). RESULTS: For standard EVAR, contrast volume and procedure time showed a significant reduction with an MD of -29 mL (95% CI -40.5 to -18.5, p<0.001) and -11 minutes (95% CI -21.0 to -1.8, p<0.01), respectively. For complex EVAR, significant reductions in favor of image fusion were found for contrast volume (MD -79 mL, 95% CI -105.7 to -52.4, p<0.001), fluoroscopy time (MD -14 minutes, 95% CI -24.2 to -3.5, p<0.001), and procedure time (MD -52 minutes, 95% CI -75.7 to -27.9, p<0.001). CONCLUSION: The results of this meta-analysis confirm that image fusion significantly reduces contrast volume, fluoroscopy time, and procedure time in complex EVAR but only contrast volume and procedure time for standard EVAR. Though a reduction was suggested, the radiation dose was not significantly affected by the use of fusion imaging in either standard or complex EVAR.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Doses de Radiação , Radiografia Intervencionista/efeitos adversos , Padrões de Referência , Estudos Retrospectivos , Resultado do Tratamento
7.
Pulm Circ ; 10(4): 2045894020907883, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33209297

RESUMO

Residual pulmonary hypertension is an important sequela after pulmonary endarterectomy for chronic thromboembolic pulmonary hypertension. Recurrent thrombosis or embolism could be a contributor to this residual pulmonary hypertension but the potential extent of its role is unknown in part because data on incidence are lacking. We aimed to analyze the incidence of new intravascular abnormalities after pulmonary endarterectomy and determine hemodynamic and functional implications. A total of 33 chronic thromboembolic pulmonary hypertension patients underwent routine CT pulmonary angiography before and six months after pulmonary endarterectomy, together with right heart catheterization and exercise testing. New vascular lesions were defined as (1) a normal pulmonary artery before pulmonary endarterectomy and containing a thrombus, web, or early tapering six months after pulmonary endarterectomy or (2) a pulmonary artery already containing thrombus, web, or early tapering at baseline, but increasing six months after pulmonary endarterectomy. Nine of 33 (27%) chronic thromboembolic pulmonary hypertension patients showed new vascular lesions on CT pulmonary angiography six months after pulmonary endarterectomy. In a subgroup of patients undergoing CT pulmonary angiography 18 months after pulmonary endarterectomy, no further changes in lesions were noted. Hemodynamic and functional outcomes were not different between patients with and without new vascular lesions. New vascular lesions are common after pulmonary endarterectomy for chronic thromboembolic pulmonary hypertension; currently their origin, dynamics, and long-term consequences remain unknown.

8.
J Endovasc Ther ; 27(3): 452-461, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32314658

RESUMO

Purpose: To assess in silicone juxtarenal aneurysm models the gutter characteristics and compression of different types of chimney graft (CG) configurations. Materials and Methods: Fifty-seven combinations of Excluder C3 or Conformable Excluder stent-grafts (23, 26, and 28.5 mm) were deployed in 2 silicone juxtarenal aneurysm models with 3 types of CGs: Viabahn self-expanding (VSE; 6 and 13 mm) or Viabahn balloon-expandable (VBX; 6, 10, and 12 mm) stent-grafts and Advanta V12 balloon-expandable stent-grafts (ABX; 6 and 12 mm). Setups were divided into 4 groups on the basis of increasing CG and main graft (MG) diameters. Two independent observers assessed gutter size and type as well as CG compression on computed tomography scans using postprocessing software. Results: In the smaller diameter combinations (6-mm CG and 23-, 26-, and 28.5-mm MGs), both VSE (p=0.006 to 0.050) and ABX (p=0.045 to 0.050) showed lower gutter areas and volumes compared with VBX. In turn, the VBX showed a nonsignificant tendency to decreased compression, especially compared to ABX. Use of the Excluder C3 showed a 6-fold increase in type A1 gutters (related to type Ia endoleak) as compared to the Conformable Excluder (p=0.018). Balloon-expandable stent-grafts (both ABX and VBX) showed a 3-fold increase in type A1 gutters in comparison with self-expanding stent-grafts (p=0.008). Conclusion: The current study suggests that use of the Conformable Excluder in combination with VSE chimney grafts is superior to the other tested CG/MG combinations in terms of gutter size, gutter type, and CG compression.


Assuntos
Angioplastia com Balão/instrumentação , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Angioplastia com Balão/efeitos adversos , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Humanos , Teste de Materiais , Modelos Anatômicos , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador
9.
J Heart Lung Transplant ; 39(3): 248-256, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31866175

RESUMO

BACKGROUND: Between 16% and 51% of patients with chronic thromboembolic pulmonary hypertension will have residual pulmonary hypertension (PH) after pulmonary endarterectomy (PEA). Whether residual PH is related to remaining (sub-)segmental macrovascular lesions or to microvascular disease is unknown. New imaging techniques can provide detailed information about (sub-)segmental pulmonary arteries and parenchymal perfusion. The aim of this study was to describe the prevalence after PEA of remaining (sub-)segmental vascular lesions on electrocardiogram-gated computed tomography pulmonary angiography (CTPA) and parenchymal hypoperfusion on magnetic resonance imaging (MRI) and to relate these imaging abnormalities to the presence or absence of residual PH after PEA. METHODS: In a prospective cohort of patients with operable chronic thromboembolic pulmonary hypertension, hemodynamics, CTPA, and lung perfusion MRI were performed before and 6 months after PEA. The percentage of (sub-)segmental vascular lesions was calculated on CTPA and parenchymal hypoperfusion on lung perfusion MRI. RESULTS: PEA led to significant improvements in hemodynamics and a reduction of imaging abnormalities. Residual PH was present in 45% of patients after PEA, whereas remaining (sub-)segmental vascular lesions and parenchymal hypoperfusion were present in 20% and 21% of the pulmonary vasculature, respectively. Patients with and without residual PH after PEA had similar percentages of remaining (sub-)segmental vascular lesions (25% ± 14% vs 17% ± 15%; p = 0.16) and similar degrees of parenchymal hypoperfusion (20% ± 7% vs 19% ± 6%; p = 0.63). CONCLUSIONS: After successful PEA, advanced imaging shows that around 20% of the pulmonary vasculature remains abnormal, independent of the presence of residual PH. This may suggest that microvascular disease, rather than residual macrovascular lesions, plays a prominent role in residual PH after PEA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Endarterectomia , Hipertensão Pulmonar/diagnóstico , Imageamento por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Tomografia Computadorizada por Raios X/métodos , Doença Crônica , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Artéria Pulmonar/cirurgia , Embolia Pulmonar/fisiopatologia , Embolia Pulmonar/cirurgia
10.
Cardiovasc Intervent Radiol ; 42(7): 962-969, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30863964

RESUMO

PURPOSE: To provide insight into the current use and results of ultrasound-facilitated catheter-directed thrombolysis (USAT) in patients with high-risk pulmonary embolism (PE). INTRODUCTION: Systemic thrombolysis is an effective treatment for hemodynamically unstable, high-risk PE, but is associated with bleeding complications. USAT is thought to reduce bleeding and is therefore advocated in patients with high-risk PE and contraindications for systemic thrombolysis. METHODS: We conducted a retrospective cohort study of all patients who underwent USAT for high-risk PE in the Netherlands from 2010 to 2017. Characteristics and outcomes were analyzed. Primary outcomes were major (including intracranial and fatal) bleeding and all-cause mortality after 1 month. Secondary outcomes were all-cause mortality and recurrent venous thromboembolism within 3 months. RESULTS: 33 patients underwent USAT for high-risk PE. Major bleeding occurred in 12 patients (36%, 95% CI 22-53), including 1 intracranial and 3 fatal bleeding. All-cause mortality after 1 month was 48% (16/33, 95% CI 31-66). All-cause mortality after 3 months was 50% (16/32, 95% CI 34-66), recurrent venous thromboembolism occurred in 1 patient (1/32, 3%, 95% CI 1-16). CONCLUSIONS: This study was the first to describe characteristics and outcomes after USAT in a study population of patients with high-risk PE only, an understudied population. Although USAT is considered a relatively safe treatment option, our results illustrate that at least caution is needed in critically ill patients with high-risk PE. Further research in patients with high-risk PE is warranted to guide patient selection.


Assuntos
Embolia Pulmonar/tratamento farmacológico , Terapia Trombolítica/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Risco , Resultado do Tratamento
11.
J Endovasc Ther ; 26(1): 62-71, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30572773

RESUMO

PURPOSE: To investigate in an in vitro model if secondary endobag filling can reduce gutter size during chimney endovascular aneurysm sealing (chEVAS). MATERIALS AND METHODS: Nellix EVAS systems were deployed in 2 silicone juxtarenal aneurysm models with suprarenal aortic diameters of 19 and 24 mm. Four configurations were tested: EVAS with 6-mm balloon-expandable (BE) or self-expanding (SE) chimney grafts (CGs) in the renal branches of both models. Balloons were inflated simultaneously in the CGs and main endografts during primary and secondary endobag filling and polymer curing. Computed tomography (CT) was performed immediately after the primary and secondary fills. Cross-sectional lumen areas were measured on the CT images to calculate gutter volumes and percent change. CG compression was calculated as the reduction in lumen surface area measured perpendicular to the central lumen line. The largest gutter volume and highest compression were presented per CG configuration per model. RESULTS: Secondary endobag filling reduced the largest gutter volumes from 99.4 to 73.1 mm3 (13.2% change) and 84.2 to 72.0 mm3 (27.6% change) in the BECG configurations and from 67.2 to 44.0 mm3 (34.5% change) and 92.7 to 82.3 mm3 (11.2% change) in the SECG configurations in the 19- and 24-mm models, respectively. Secondary endobag filling increased CG compression in 6 of 8 configurations. BECG compression changed by -0.2% and 5.4% and by -1.0% and 0.4% in the 19- and 24-mm models, respectively. SECG compression changed by 10.2% and 16.0% and by 7.2% and 7.3% in the 19- and 24-mm models, respectively. CONCLUSION: Secondary endobag filling reduced paragraft gutters; however, this technique did not obliterate them. Increased CG compression and prolonged renal ischemia time should be considered if secondary endobag filling is used.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese
12.
Eur J Vasc Endovasc Surg ; 56(5): 663-671, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30115505

RESUMO

OBJECTIVES: Perivascular adipose tissue (PVAT) is currently seen as a paracrine organ that produces vasoactive substances, including inflammatory agents, which may have an impact on the vasculature. In this study PVAT density was quantified in patients with an aortic aneurysm and compared with those with a non-dilated aorta. Since chronic inflammation, as the pathway to medial thinning, is a hallmark of abdominal aortic aneurysms (AAAs), it was hypothesised that PVAT density is higher in AAA patients. METHODS: In this multicentre retrospective case control study, three groups of patients were included: non-treated asymptomatic AAA (n = 140), aortoiliac occlusive disease (AIOD) (n = 104), and individuals without aortic pathology (n = 97). A Hounsfield units based analysis was performed by computed tomography (CT). As a proxy for PVAT, the density of adipose tissue 10 mm circumferential to the infrarenal aorta was analysed in each consecutive CT slice. Intra-individual PVAT differences were reported as the difference in PVAT density between the region of the maximum AAA diameter (or the mid-aortic region in patients with AIOD or controls) and the two uppermost slices of infrarenal non-dilated aorta just below the renal arteries. Furthermore, subcutaneous (SAT) and visceral (VAT) adipose tissue measurements were performed. Linear models were fitted to assess the association between the study groups, different adipose tissue compartments, and between adipose tissue compartments and aortic dimensions. RESULTS: AAA patients presented higher intra-individual PVAT differences, with higher PVAT density around the aneurysm sac than the healthy neck. This association persisted after adjustment for cardiovascular risk factors and diseases and other fat compartments (ß = 13.175, SE 4.732, p = .006). Furthermore, intra-individual PVAT differences presented the highest correlation with aortic volume that persisted after adjustment for other fat compartments, body mass index, sex, and age (ß = 0.566, 0.200, p = .005). CONCLUSION: The results suggest a relation between the deposition of PVAT and AAA pathophysiology. Further research should explore the exact underlying processes.


Assuntos
Tecido Adiposo/cirurgia , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma Aórtico/cirurgia , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
Respiration ; 95(4): 220-227, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29433123

RESUMO

BACKGROUND: Traditionally, surgical resection is the preferred treatment for typical carcinoids and atypical carcinoids located in the lungs. Recently however, several studies have shown excellent long-term outcome after endobronchial treatment of carcinoid tumors located in the central airways. This study investigates clinical and radiological features as predictors of successful endobronchial treatment in patients with a bronchial carcinoid tumor. OBJECTIVES: To identify clinical and radiological features predictive of successful endobronchial treatment in patients with bronchial carcinoid. METHODS: This analysis was performed in a cohort of patients with typical and atypical bronchial carcinoid referred for endobronchial treatment. Several patient characteristics, radiological features, and histological grade (typical or atypical carcinoid) were tested as predictors of successful endobronchial treatment. RESULTS: One hundred and twenty-five patients with a diagnosis of bronchial carcinoid underwent endobronchial treatment. On multivariate analysis, a tumor diameter <15 mm (odds ratio 0.09; 95% confidence interval 0.02-0.5; p = <0.01) and purely intraluminal growth on computer tomography (CT scan) (odds ratio, 9.1; 95% confidence interval 1.8-45.8; p = <0.01) were predictive of radical endobronchial treatment. The success rate for intraluminal tumors with a diameter <20 mm was 72%. CONCLUSIONS: Purely intraluminal disease and tumor diameter on CT scan seem to be independent predictors for successful endobronchial treatment in patients with bronchial carcinoid. Based on these data, patients with purely intraluminal carcinoid tumors with a diameter <20 mm on CT scan are good candidates for endobronchial treatment, regardless of histological grade. In contrast, all patients with a tumor diameter ≥20 mm should be directly referred for surgery.


Assuntos
Neoplasias Brônquicas/cirurgia , Broncoscopia/estatística & dados numéricos , Tumor Carcinoide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Brônquicas/mortalidade , Tumor Carcinoide/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Estudos Retrospectivos , Adulto Jovem
16.
BMJ Open ; 7(8): e014365, 2017 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-28801387

RESUMO

INTRODUCTION: Acute peripheral arterial occlusions can be treated with intra-arterial catheter-directed thrombolysis as an alternative to surgical thromboembolectomy. Although less invasive, this treatment is time-consuming and carries a significant risk of haemorrhagic complications. Contrast-enhanced ultrasound using microbubbles could accelerate dissolution of thrombi by thrombolytic medications due to mechanical effects caused by oscillation; this could allow for lower dosages of thrombolytics and faster thrombolysis, thereby reducing the risk of haemorrhagic complications. In this study, the safety and practical applicability of this treatment will be investigated. METHODS AND ANALYSIS: A single-arm phase II trial will be performed in 20 patients with acute peripheral arterial occlusions eligible for thrombolytic treatment. Low-dose catheter-directed thrombolysis with urokinase will be used. The investigated treatment will be performed during the first hour of thrombolysis, consisting of intravenous infusion of 4 Luminity phials (6 mL in total, diluted with saline 0.9% to 40 mL total) of microbubbles with the use of local ultrasound at the site of occlusion. Primary end points are the incidence of complications and technical feasibility. Secondary end points are angiographic and clinical success, duration of thrombolytic infusion, treatment-related mortality, amputations, additional interventions and quality of life. ETHICS AND DISSEMINATION: Ethical approval for this study was obtained in 2015 from the Medical Ethics Committee of the VU University Medical Center, Amsterdam, the Netherlands. A statement of consent for this study was given by the Dutch national competent authority. Data will be presented at national and international conferences and published in a peer-reviewed journal. TRIAL REGISTRATION NUMBERS: Dutch National Trial Registry: NTR4731; European Clinical Trials Database of the European Medicines Agency: 2014-003469-10; Pre-results.


Assuntos
Cateterismo Periférico , Fibrinolíticos/uso terapêutico , Hemorragia/prevenção & controle , Microbolhas/uso terapêutico , Doença Arterial Periférica/terapia , Terapia Trombolítica , Terapia por Ultrassom , Cateterismo Periférico/métodos , Meios de Contraste/uso terapêutico , Estudos de Viabilidade , Humanos , Países Baixos , Doença Arterial Periférica/tratamento farmacológico , Medição de Risco , Fatores de Risco , Terapia Trombolítica/métodos , Terapia Trombolítica/tendências , Resultado do Tratamento , Terapia por Ultrassom/métodos , Terapia por Ultrassom/tendências
17.
Int J Cardiovasc Imaging ; 31(4): 871-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25687575

RESUMO

The most common feature of pulmonary hypertension (PH) on computed tomography pulmonary angiography (CTPA) is an increased diameter-ratio of the pulmonary artery to the ascending aorta (PA/AAAX). The aim of this study was to investigate whether combining PA/AAAX measurements with ventricular measurements improves the predictive value of CTPA for precapillary PH. Three predicting models were analysed using baseline CTPA scans of 51 treatment naïve precapillary PH patients and 25 non-PH controls: model 1: PA/AAAX only; model 2: PA/AAAX combined with the ratio of the right ventricular and left ventricular diameter measured on the axial view (RV/LVAX); model 3: PA/AAAX combined with the RV/LV-ratio measured on a four chamber view (RV/LV4CH). Prediction models were compared using multivariable binary logistic regression, ROC analyses and decision curve analyses (DCA). Multivariable binary logistic regression showed an improvement of the predictive value of model 2 (-2LL = 26.48) and 3 (-2LL = 21.03) compared to model 1 (-2LL = 21.03). ROC analyses showed significantly higher AUCs of model 2 and 3 compared to model 1 (p = 0.011 and p = 0.007, respectively). DCA showed an increased clinical benefit of model 2 and 3 compared to model 1. The predictive value of model 2 and 3 were almost equal. We found an optimal cut-off value for the RV/LV-ratio for predicting precapillary PH of RV/LV ≥ 1.20. The predictive value of CTPA for precapillary PH improves when ventricular and pulmonary artery measurements are combined. A PA/AAAX ≥ 1 or a RV/LVAX ≥ 1.20 needs further diagnostic evaluation to rule out or confirm the diagnosis.


Assuntos
Aortografia/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores , Artéria Pulmonar/diagnóstico por imagem , Área Sob a Curva , Diagnóstico Precoce , Hemodinâmica , Humanos , Hipertensão Pulmonar/fisiopatologia , Modelos Logísticos , Análise Multivariada , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Curva ROC , Estudos Retrospectivos
18.
Case Rep Med ; 2014: 205646, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25276140

RESUMO

Purpose. To describe the treatment of renal artery thrombosis with ultrasound-accelerated thrombolysis and discuss the management of prolonged renal ischemia. Case. A 76-year-old patient with a single functional kidney, mild chronic renal impairment, and a recent history of endovascular repair of a thoracoabdominal aneurysm with an aortic branch graft presented with acute flank pain, anuria, and renal failure. The side branch from the aortic stent graft to his single, right, functional kidney appeared to be completely thrombosed. Symptoms had started after cessation of oral anticoagulants because of a planned mastectomy for breast cancer. After identification of the occlusion, ultrasound-accelerated thrombolysis was started 19 hours after the onset of anuria. Angiography, 4 hours after beginning of therapy, already showed partial dissolution of the thrombus and angiographic control after 18 hours showed complete patency of the renal artery side branch. Despite a long period of ischemia, renal function was completely recovered. Conclusion. In patients with acute renal ischemia due to thrombosis of the renal artery, complete recovery of function can be achieved with ultrasound-accelerated thrombolysis, even after prolonged periods of ischemia.

19.
Arch Pathol Lab Med ; 137(12): 1792-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24283861

RESUMO

CONTEXT: Surgical removal and pathologic handling of lung tissue has a compressive effect upon its architecture. The effect of surgical atelectasis on morphology has not been examined in depth, especially with respect to lung adenocarcinomas. OBJECTIVE: To examine the influence of surgical atelectasis on morphologic lepidic growth pattern, mimicking papillary adenocarcinoma pattern. DESIGN: In 2 cases serial sections of resected pulmonary adenocarcinoma were used, as was a 3-dimensional reconstruction. Elastin stains were performed on primary and metastatic adenocarcinomas. RESULTS: Perfusion fixation of another case showed marked morphologic differences of less compressed peripheral lung tissue, emphasizing the preexisting alveolar structure. An elastic stain may help identify true lesional architecture. CONCLUSIONS: We demonstrate that microscopic sections of adenocarcinoma in situ in compressed/collapsed tissue may give rise to a pseudopapillary pattern mimicking invasive adenocarcinoma. Accurate appreciation of different tumor architecture in lung adenocarcinoma has important biologic and clinical implications. Pathologists should be aware of the possibility of misclassification of adenocarcinoma pattern due to tissue artifacts caused by lung tissue handling.


Assuntos
Adenocarcinoma Papilar/diagnóstico , Adenocarcinoma Papilar/patologia , Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Histocitoquímica/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Adenocarcinoma/metabolismo , Adenocarcinoma Papilar/metabolismo , Idoso de 80 Anos ou mais , Artefatos , Biomarcadores Tumorais/metabolismo , Diagnóstico Diferencial , Elastina/metabolismo , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/metabolismo , Neoplasias Pulmonares/metabolismo , Masculino , Pessoa de Meia-Idade , Manejo de Espécimes/efeitos adversos , Tomografia Computadorizada por Raios X
20.
J Endovasc Ther ; 20(4): 498-505, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23914859

RESUMO

PURPOSE: To investigate the feasibility of using endoanchor technology to reduce chimney graft-related gutter size in a juxtarenal aneurysm model. METHODS: In silicone juxtarenal aortic aneurysm models with two sizes of branch arteries and two sizes of aorta, single chimney graft (CG) configurations were constructed using 6-mm Atrium balloon-expandable stent-grafts in association with two sizes of Gore Excluder main grafts (23 and 28.5 mm). Configurations without Aptus EndoAnchors, with suprarenal placement of EndoAnchors, and with additional infrarenal placement of EndoAnchors were investigated. A total of 12 CG configurations were scanned using 64-slice computed tomography. Gutter volume and gutter areas at the top and bottom of the sealing zone were measured with image processing software. RESULTS: The combination of supra- and infrarenal placement of endoanchors led to a reduction in gutter volume compared to unanchored configurations. The same configurations also led to a decrease in gutter area at the bottom of the sealing zone. CONCLUSION: It is feasible to reduce gutters in CG configurations with the use of endoanchors in an in vitro juxtarenal aneurysm model.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares , Modelos Anatômicos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...