Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 423
Filtrar
1.
J. bras. nefrol ; 46(3): e20230029, July-Sept. 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550504

RESUMO

ABSTRACT Introduction: Lung diseases are common in patients with end stage kidney disease (ESKD), making differential diagnosis with COVID-19 a challenge. This study describes pulmonary chest tomography (CT) findings in hospitalized ESKD patients on renal replacement therapy (RRT) with clinical suspicion of COVID-19. Methods: ESKD individuals referred to emergency department older than 18 years with clinical suspicion of COVID-19 were recruited. Epidemiological baseline clinical information was extracted from electronic health records. Pulmonary CT was classified as typical, indeterminate, atypical or negative. We then compared the CT findings of positive and negative COVID-19 patients. Results: We recruited 109 patients (62.3% COVID-19-positive) between March and December 2020, mean age 60 ± 12.5 years, 43% female. The most common etiology of ESKD was diabetes. Median time on dialysis was 36 months, interquartile range = 12-84. The most common pulmonary lesion on CT was ground glass opacities. Typical CT pattern was more common in COVID-19 patients (40 (61%) vs 0 (0%) in non-COVID-19 patients, p < 0.001). Sensitivity was 60.61% (40/66) and specificity was 100% (40/40). Positive predictive value and negative predictive value were 100% and 62.3%, respectively. Atypical CT pattern was more frequent in COVID-19-negative patients (9 (14%) vs 24 (56%) in COVID-19-positive, p < 0.001), while the indeterminate pattern was similar in both groups (13 (20%) vs 6 (14%), p = 0.606), and negative pattern was more common in COVID-19-negative patients (4 (6%) vs 12 (28%), p = 0.002). Conclusions: In hospitalized ESKD patients on RRT, atypical chest CT pattern cannot adequately rule out the diagnosis of COVID-19.


RESUMO Introdução: Doenças pulmonares são comuns em pacientes com doença renal em estágio terminal (DRET), dificultando o diagnóstico diferencial com COVID-19. Este estudo descreve achados de tomografia computadorizada de tórax (TC) em pacientes com DRET em terapia renal substitutiva (TRS) hospitalizados com suspeita de COVID-19. Métodos: Indivíduos maiores de 18 anos com DRET, encaminhados ao pronto-socorro com suspeita de COVID-19 foram incluídos. Dados clínicos e epidemiológicos foram extraídos de registros eletrônicos de saúde. A TC foi classificada como típica, indeterminada, atípica, negativa. Comparamos achados tomográficos de pacientes com COVID-19 positivos e negativos. Resultados: Recrutamos 109 pacientes (62,3% COVID-19-positivos) entre março e dezembro de 2020, idade média de 60 ± 12,5 anos, 43% mulheres. A etiologia mais comum da DRET foi diabetes. Tempo médio em diálise foi 36 meses, intervalo interquartil = 12-84. A lesão pulmonar mais comum foi opacidades em vidro fosco. O padrão típico de TC foi mais comum em pacientes com COVID-19 (40 (61%) vs. 0 (0%) em pacientes sem COVID-19, p < 0,001). Sensibilidade 60,61% (40/66), especificidade 100% (40/40). Valores preditivos positivos e negativos foram 100% e 62,3%, respectivamente. Padrão atípico de TC foi mais frequente em pacientes COVID-19-negativos (9 (14%) vs. 24 (56%) em COVID-19-positivos, p < 0,001), enquanto padrão indeterminado foi semelhante em ambos os grupos (13 (20%) vs. 6 (14%), p = 0,606), e padrão negativo foi mais comum em pacientes COVID-19-negativos (4 (6%) vs. 12 (28%), p = 0,002). Conclusões: Em pacientes com DRET em TRS hospitalizados, um padrão atípico de TC de tórax não pode excluir adequadamente o diagnóstico de COVID-19.

2.
J Thorac Dis ; 16(4): 2443-2459, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38738236

RESUMO

Background: Myocardial infarction (MI) is one of the most lethal cardiovascular diseases. The loss of cardiomyocytes and the degradation of the extracellular matrix leads to high ventricular wall stress, which further drives the pathological thinning of the ventricular wall during MI. Injecting biomaterials to thicken the infarct ventricular wall provides mechanical support, thereby inhibiting the continued expansion of the heart. As an injectable biomaterial, alginate hydrogel has achieved exciting results in clinical trials, but further research needs to be conducted to determine whether it can improve cardiac function in addition to providing mechanical support. This study sought to explore these mechanisms in an animal model of MI. Methods: A MI model was established in male C57BL/6J mice by ligation of the proximal left anterior descending (LAD) coronary artery. Intramyocardial injections (hydrogel or saline group) were performed in the proximal wall regions bordering the infarct area (with one 20-µL injection). Four weeks after MI, RNA sequencing revealed that 342 messenger RNAs (mRNAs) from the infarcted hearts were differentially expressed between the saline group and hydrogel group. We subsequently conducted a Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway analysis to analyze the RNA sequencing data. In addition, we employed both western blotting and quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) techniques to verify a number of genes that were differentially expressed and could potentially affect cardiac function after MI. Subsequently, we confirmed these findings through in vitro experiments. Results: We found that compared with hydrogel treatment group, 250 mRNAs were upregulated and 92 mRNAs were downregulated in saline group (P<0.05). And by exploring the GO and KEGG signaling pathways as well as the protein-protein interaction (PPI) network, we found that administration of alginate hydrogel modulated cardiomyocyte inflammation-associated proteins as well as chemokine-related proteins during the inflammatory response phase after MI. In addition, our analysis at both the protein and RNA level revealed that B2M was effective in improving cardiac function after MI in the hydrogel treatment group, which was consistent in the myocardium oxygen and glucose deprivation (OGD) injury model. Conclusions: We explored the transcriptome changes of infarcted hearts after alginate-hydrogel injection during the inflammatory response period. Our findings suggest that the injectable hydrogel directly alters the inflammatory response and the chemokine-mediated signaling pathway of cardiomyocytes, ultimately improving cardiac function.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38702271

RESUMO

BACKGROUND: Direct coronary arterial evaluation via computed tomography (CT) angiography is the most accurate noninvasive test for the diagnosis of coronary artery disease (CAD). However, diagnostic accuracy is limited in the setting of severe coronary calcification or stents. Ultra-high-resolution CT (UHR-CT) may overcome this limitation, but no rigorous study has tested this hypothesis. METHODS: The CORE-PRECISION is an international, multicenter, prospective diagnostic accuracy study testing the non-inferiority of UHR-CT compared to invasive coronary angiography (ICA) for identifying patients with hemodynamically significant CAD. The study will enroll 150 patients with history of CAD, defined as prior documentation of lumen obstruction, stenting, or a calcium score ≥400, who will undergo UHR-CT before clinically prompted ICA. Assessment of hemodynamically significant CAD by UHR-CT and ICA will follow clinical standards. The reference standard will be the quantitative flow ratio (QFR) with <0.8 defined as abnormal. All data will be analyzed in independent core laboratories. RESULTS: The primary outcome will be the comparative diagnostic accuracy of UHR-CT vs. ICA for detecting hemodynamically significant CAD on a patient level. Secondary analyses will focus on vessel level diagnostic accuracy, quantitative stenosis analysis, automated contour detection, in-depth plaque analysis, and others. CONCLUSION: CORE-PRECISION aims to investigate if UHR-CT is non-inferior to ICA for detecting hemodynamically significant CAD in high-risk patients, including those with severe coronary calcification or stents. We anticipate this study to provide valuable insights into the utility of UHR-CT in this challenging population and for its potential to establish a new standard for CAD assessment.

4.
JACC Asia ; 4(3): 171-182, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38463674

RESUMO

Background: The ASET (Acetyl-Salicylic Elimination Trial) pilot studies recently investigated P2Y12 inhibitor monotherapy without aspirin immediately after percutaneous coronary intervention (PCI) in Brazil and Japan. Objectives: This comparative analysis of the 2 ASET pilot studies aimed to summarize clinical outcomes and assess geographic and ethnic differences in baseline demographics and procedures. Methods: Patients undergoing successful platinum-chromium everolimus-eluting stent implantation for chronic coronary syndrome were included. Following the index PCI, patients received prasugrel monotherapy with a maintenance dose of 10 mg/day in Brazil and 3.75 mg/day in Japan. The primary ischemic endpoint was the composite of cardiac death, spontaneous target vessel myocardial infarction, or definite stent thrombosis. The primary bleeding endpoint was Bleeding Academic Research Consortium types 3 and 5 bleeding at up to 3 months. Results: Of 409 enrollments, 3-month follow-up was completed in 406 patients. Mean age was 64.3 ± 8.4 years, and 73% were men. Overall, post-TIMI flow grade 3 was achieved in 99.8%. Intravascular imaging for poststent optimization was used in 16.8% and 99.6% of treated lesions in Brazil and Japan, respectively. The primary ischemic and bleeding endpoints occurred in the same patient (0.2%). No stent thrombosis events occurred. Conclusions: Prasugrel monotherapy following PCI was safe and feasible in selected low-risk chronic coronary syndrome patients after optimal platinum-chromium everolimus-eluting stent implantation regardless of the ethnic and geographic differences in baseline demographics, procedures, and prasugrel dosage. Randomized controlled trials will be needed to compare P2Y12 inhibitor monotherapy without aspirin with the current standard of care.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38492976

RESUMO

BACKGROUND: Coronary drug-eluting stents (DES) built with either durable (DP) or biodegradable (BP) polymeric coatings have been largely tested and are extensively available for routine use. However, their comparative performance remains an open question, particularly in more complex subsets of patients. AIMS: We evaluated the outcomes of patients with ST-elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (pPCI) using DP-DES versus BP-DES in a large multicenter real-world registry. METHODS: The population comprised patients with STEMI treated with pPCI within 12 h of symptoms onset. Those treated with more than one DES who received different polymer types were excluded. The final cohort for analysis was selected after propensity score matching (PSM), computed to generate similar groups of DP DES versus BP DES. Primary endpoint was the incidence of major adverse cardiac events (MACE), defined as the composite of total death, myocardial infarction and target lesion revascularization at 2 years. RESULTS: From January 2017 to April 2022, a total of 1527 STEMI patients underwent pPCI with a single DES type (587 DP-DES; 940 BP-DES). After PSM, 836 patients (418 patients in the DP-DES and 418 patients in the BP-DES groups), comprised the final study population. Both study groups had a similar baseline profile. Patients treated with BP-DES group had similar rates of MACE (15.3 % vs. 19.4 %, HR 0.69, 95 % CI 0.50-0.94, p = 0.022). Rates of target lesion revascularization was lower in BP DES group (0.7 % vs. 3.8 %, HR 0.17, 95 % CI 0.05-0.51, p = 0.006). CONCLUSION: In a cohort of STEMI patients submitted to pPCI, BP and DP DES had similar rates of the primary outcome. Patients treated with BP DES, however, had a decreased incidence of TLR at after 2-year follow-up.

6.
J Bras Nefrol ; 46(3): e20230029, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38502952

RESUMO

INTRODUCTION: Lung diseases are common in patients with end stage kidney disease (ESKD), making differential diagnosis with COVID-19 a challenge. This study describes pulmonary chest tomography (CT) findings in hospitalized ESKD patients on renal replacement therapy (RRT) with clinical suspicion of COVID-19. METHODS: ESKD individuals referred to emergency department older than 18 years with clinical suspicion of COVID-19 were recruited. Epidemiological baseline clinical information was extracted from electronic health records. Pulmonary CT was classified as typical, indeterminate, atypical or negative. We then compared the CT findings of positive and negative COVID-19 patients. RESULTS: We recruited 109 patients (62.3% COVID-19-positive) between March and December 2020, mean age 60 ± 12.5 years, 43% female. The most common etiology of ESKD was diabetes. Median time on dialysis was 36 months, interquartile range = 12-84. The most common pulmonary lesion on CT was ground glass opacities. Typical CT pattern was more common in COVID-19 patients (40 (61%) vs 0 (0%) in non-COVID-19 patients, p < 0.001). Sensitivity was 60.61% (40/66) and specificity was 100% (40/40). Positive predictive value and negative predictive value were 100% and 62.3%, respectively. Atypical CT pattern was more frequent in COVID-19-negative patients (9 (14%) vs 24 (56%) in COVID-19-positive, p < 0.001), while the indeterminate pattern was similar in both groups (13 (20%) vs 6 (14%), p = 0.606), and negative pattern was more common in COVID-19-negative patients (4 (6%) vs 12 (28%), p = 0.002). CONCLUSIONS: In hospitalized ESKD patients on RRT, atypical chest CT pattern cannot adequately rule out the diagnosis of COVID-19.


Assuntos
COVID-19 , Falência Renal Crônica , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , SARS-CoV-2 , Diálise Renal , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Estudos Retrospectivos
7.
Coron Artery Dis ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38411184

RESUMO

BACKGROUND: Percutaneous coronary interventions in heavily calcified coronary lesions are associated with technical difficulties and the worse prognosis. Lesion preparation is important to reduce complications and improve outcomes. The aim of this study is to compare the results of rotational atherectomy (RA) and intravascular lithotripsy (IVL) at achieving optimal stent implantation using intravascular ultrasound criteria. METHODS: Retrospective, single-center study comparing patients with heavily calcified coronary lesions that underwent percutaneous coronary interventions using RA or IVL. RESULTS IN TOTAL: 25 patients (13 in the RA group and 12 in the IVL group) were included. Reference vessel diameter was similar between the groups [2.59 (2.51-3.63) mm in the RA group vs. 2.79 (2.59-3.16) mm in the IVL group; P = 0.89], as were minimal lumen area [1.02 (0.80-1.23) mm vs. 1.40 (1.01-1.40) mm; P = 0.43] and diameter stenosis [60.4% (52.3-72.3) vs. 56.1% (47.8-61.3); P = 0.56). The final minimal lumen area was significantly larger in the IVL group [7.6 mm2 (5.8-8.6) vs. 5.4 mm2 (4.5-6.2); P = 0.01] as were lumen area gain [4.1 mm2 (2.6-5.9) vs. 2.3 mm2 (1.4-3.6); P = 0.01] and final stent volume [491.2 mm3 (372.2-729.8) vs. 326.2 mm3 (257.1-435.4); P = 0.03]. In the RA group, 69.2% of the patients achieved the preestablished intravascular ultrasound-based criteria for successful stent implantation, vs. 100% of the patients in the IVL group (P = 0.04). CONCLUSION: Patients in the IVL group achieved the Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation trial criteria of successful stent implantation more frequently than those treated with RA.

8.
Sci Rep ; 14(1): 1493, 2024 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233429

RESUMO

Coronary artery disease is defined by the existence of atherosclerotic plaque on the arterial wall, which can cause blood flow impairment, or plaque rupture, and ultimately lead to myocardial ischemia. Intravascular ultrasound (IVUS) imaging can provide a detailed characterization of lumen and vessel features, and so plaque burden, in coronary vessels. Prediction of the regions in a vascular segment where plaque burden can either increase (progression) or decrease (regression) following a certain therapy, has remained an elusive major milestone in cardiology. Studies like IBIS-4 showed an association between plaque burden regression and high-intensity rosuvastatin therapy over 13 months. Nevertheless, it has not been possible to predict if a patient would respond in a favorable/adverse fashion to such a treatment. This work aims to (i) Develop a framework that processes lumen and vessel cross-sectional contours and extracts geometric descriptors from baseline and follow-up IVUS pullbacks; and to (ii) Develop, train, and validate a machine learning model based on baseline/follow-up IVUS datasets that predicts future percent of atheroma volume changes in coronary vascular segments using only baseline information, i.e. geometric features and clinical data. This is a post hoc analysis, revisiting the IBIS-4 study. We employed 140 arteries, from 81 patients, for which expert delineation of lumen and vessel contours were available at baseline and 13-month follow-up. Contour data from baseline and follow-up pullbacks were co-registered and then processed to extract several frame-wise features, e.g. areas, plaque burden, eccentricity, etc. Each pullback was divided into regions of interest (ROIs), following different criteria. Frame-wise features were condensed into region-wise markers using tools from statistics, signal processing, and information theory. Finally, a stratified 5-fold cross-validation strategy (20 repetitions) was used to train/validate an XGBoost regression models. A feature selection method before the model training was also applied. When the models were trained/validated on ROI defined by the difference between follow-up and baseline plaque burden, the average accuracy and Mathews correlation coefficient were 0.70 and 0.41 respectively. Using a ROI partition criterion based only on the baseline's plaque burden resulted in averages of 0.60 accuracy and 0.23 Mathews correlation coefficient. An XGBoost model was capable of predicting plaque progression/regression changes in coronary vascular segments of patients treated with rosuvastatin therapy in 13 months. The proposed method, first of its kind, successfully managed to address the problem of stratification of patients at risk of coronary plaque progression, using IVUS images and standard patient clinical data.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Rosuvastatina Cálcica/uso terapêutico , Estudos Transversais , Ultrassonografia de Intervenção/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/diagnóstico por imagem
9.
Int J Cardiol ; 400: 131805, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272132

RESUMO

BACKGROUND: The geographical disparity in the pathophysiological pattern of coronary artery disease (CAD) among patients undergoing percutaneous coronary intervention (PCI) is unknown. OBJECTIVES: To elucidate the geographical variance in the pathophysiological characteristics of CAD. METHODS: Physiological indices derived from angiography-based fractional flow reserve pullbacks from patients with chronic coronary syndrome enrolled in the ASET Japan (n = 206) and ASET Brazil (n = 201) studies, which shared the same eligibility criteria, were analysed. The pathophysiological patterns of CAD were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the µQFR pullback pressure gradient index. RESULTS: Significant functional stenoses pre-PCI (µQFR ≤0.80) were more frequent in ASET Japan compared to ASET Brazil (89.9% vs. 67.5%, p < 0.001), as were rates of a post-PCI µQFR <0.91 (22.1% vs. 12.9%, p = 0.013). In the multivariable analysis, pre-procedural µQFR and diffuse disease were independent factors for predicting a post-PCI µQFR <0.91, which contributed to the different rates of post-PCI µQFR ≥0.91 between the studies. Among vessels with a post-PCI µQFR <0.91, a consistent diffuse pattern of CAD pre- and post-PCI occurred in 78.3% and 76.7% of patients in ASET Japan and Brazil, respectively; only 6.3% (Japan) and 10.0% (Brazil) of vessels had a major residual gradient. Independent risk factors for diffuse disease were diabetes mellitus in ASET Japan, and age and male gender in Brazil. CONCLUSIONS: There was geographic disparity in pre-procedural angiography-based pathophysiological characteristics. The combined pre-procedural physiological assessment of vessel µQFR and diffuseness of CAD may potentially identify patients who will benefit most from PCI.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária , Resultado do Tratamento , Vasos Coronários , Valor Preditivo dos Testes
10.
Cardiol Res ; 14(4): 291-301, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37559713

RESUMO

Background: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. Methods: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. Results: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16). Conclusions: The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.

11.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529710

RESUMO

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

12.
Cardiol Res. ; 14(4): 291-301, ago.2023. ilus
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1525284

RESUMO

BACKGROUND: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. METHODS: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. RESULTS: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doenças Cardiovasculares , Everolimo
13.
J. Transcatheter Interv ; 31(supl.1): 146-146, jul.-set. 2023.
Artigo em Português | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1513143

RESUMO

INTRODUÇÃO: Não existem estudos comparando os desfechos clínicos do implante de válvula aórtica transcateter (TAVI) com próteses balão-expansíveis (BE) versus auto-expansíveis (AE) de nova geração na realidade brasileira. OBJETIVO: Comparar os resultados clínicos intra-hospitalares de TAVI realizados com próteses BE de nova geração contra próteses AE de nova geração em centros brasileiros participantes do RIBAC-NT. MÉTODOS: Foram utilizados dados de centros ativamente participantes do registro brasileiro de TAVI. Critério de inclusão: todos os procedimentos de TAVI em válvula nativa tricúspide com utilização de próteses de nova geração. Critério de exclusão principal: procedimentos pela via transapical. Os casos foram separados conforme a prótese utilizada em grupo BE (Sapien S3, S3 Ultra e Myval) e AE (Evolut R, Evolut PRO, Acurate Neo, Acurate Neo2 e Portico). Desfecho primário analisado foi morte intra-hospitalar. Desfechos secundários: complicação vascular maior, sangramento maior, sangramento com risco de vida, qualquer acidente vascular encefálico (AVE) e novo implante de marcapasso. RESULTADOS: Ao todo 1703 pacientes de 25 centros foram incluídos na análise, sendo 887 no grupo BE e 819 no grupo AE. A idade média da população foi 80,7±7,2 anos e 48,9% eram mulheres. O grupo AE teve uma maior proporção de pacientes do sexo feminino (53,5% vs. 44,6%, P=<0,001), maior prevalência de doença arterial periférica (16,2% vs. 11%, P=0,002) e de doença pulmonar obstrutiva crônica (16,8% vs. 11,5%, P=0,002), além de Euroscore 2 maior (6,2 vs. 5,5, P=0,03). Tabela 1 estão demonstradas a comparação das características do procedimento entre os grupos. Pacientes do grupo BE realizaram mais procedimentos com anestesia geral, mais por via transfemoral e também com maior proporção de acessos totalmente percutâneos. No grupo AE houve maior necessidade de pré e pós-dilatação e discreta maior incidência de embolização e necessidade de uma segunda prótese, assim como maior incidência de oclusão coronariana. Tabela 2 sumariza o comparativo dos desfechos clínicos. Não houve diferença significativa para a mortalidade intra-hospitalar entre os grupos. Também não se observou diferença entre complicações vasculares, sangramentos, AVE e necessidade de novo marcapasso. Regressão logístico multivariada ajustando para diferenças entre os grupos não indicou diferença de mortalidade entre utilização de prótese BE vs. AE (OR 0,95, P=0,8). Preditores independentes de mortalidade foram sexo feminino (OR 0,49, P=0,009) e Euroscore 2 (OR 1,04, P=0,006). CONCLUSÃO: Em estudo de vida real de pacientes submetidos a TAVI no Brasil, não houve diferença da mortalidade intra-hospitalar entra a utilização de próteses BE de nova geração em comparação a utilização de próteses AE de nova geração.


Assuntos
Angioplastia com Balão , Substituição da Valva Aórtica Transcateter
14.
EuroIntervention ; 19(4): E323-E329, jul.2023.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444455

RESUMO

Dual antiplatelet therapy (DAPT) is currently the standard of care after percutaneous coronary intervention (PCI). Recent studies suggest that reducing DAPT to 1-3 months followed by an aspirin-free single antiplatelet therapy (SAPT) strategy with a potent P2Y12 inhibitor is safe and associated with less bleeding. However, to date, no randomised trial has tested the impact of initiating SAPT immediately after PCI, particularly in patients with acute coronary syndromes (ACS). NEOMINDSET is a multicentre, randomised, open-label trial with a blinded outcome assessment designed to compare SAPT versus DAPT in 3,400 ACS patients undergoing PCI with the latest-generation drug-eluting stents (DES). After successful PCI and up to 4 days following hospital admission, patients are randomised to receive SAPT with a potent P2Y12 inhibitor (ticagrelor or prasugrel) or DAPT (aspirin plus a potent P2Y12 inhibitor) for 12 months. Aspirin is discontinued immediately after randomisation in the SAPT group. The choice between ticagrelor and prasugrel is at the investigator's discretion. The primary hypothesis is that SAPT will be non-inferior to DAPT with respect to the composite endpoint of all-cause mortality, stroke, myocardial infarction or urgent target vessel revascularisation, but superior to DAPT on rates of bleeding defined by Bleeding Academic Research Consortium 2, 3 or 5 criteria. NEOMINDSET is the first study that is specifically designed to test SAPT versus DAPT immediately following PCI with DES in ACS patients. This trial will provide important insights on the efficacy and safety of withdrawing aspirin in the early phase of ACS.

15.
Circulation ; 147(25): 1933-1944, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37335828

RESUMO

Antiplatelet therapy is the mainstay of pharmacologic treatment to prevent thrombotic or ischemic events in patients with coronary artery disease treated with percutaneous coronary intervention and those treated medically for an acute coronary syndrome. The use of antiplatelet therapy comes at the expense of an increased risk of bleeding complications. Defining the optimal intensity of platelet inhibition according to the clinical presentation of atherosclerotic cardiovascular disease and individual patient factors is a clinical challenge. Modulation of antiplatelet therapy is a medical action that is frequently performed to balance the risk of thrombotic or ischemic events and the risk of bleeding. This aim may be achieved by reducing (ie, de-escalation) or increasing (ie, escalation) the intensity of platelet inhibition by changing the type, dose, or number of antiplatelet drugs. Because de-escalation or escalation can be achieved in different ways, with a number of emerging approaches, confusion arises with terminologies that are often used interchangeably. To address this issue, this Academic Research Consortium collaboration provides an overview and definitions of different strategies of antiplatelet therapy modulation for patients with coronary artery disease, including but not limited to those undergoing percutaneous coronary intervention, and consensus statements on standardized definitions.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Trombose , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Doença da Artéria Coronariana/complicações , Hemorragia/etiologia , Plaquetas , Terapia Antiplaquetária Dupla/efeitos adversos , Síndrome Coronariana Aguda/terapia , Trombose/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
16.
EuroIntervention ; 19(4): e323-e329, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37306039

RESUMO

Dual antiplatelet therapy (DAPT) is currently the standard of care after percutaneous coronary intervention (PCI). Recent studies suggest that reducing DAPT to 1-3 months followed by an aspirin-free single antiplatelet therapy (SAPT) strategy with a potent P2Y12 inhibitor is safe and associated with less bleeding. However, to date, no randomised trial has tested the impact of initiating SAPT immediately after PCI, particularly in patients with acute coronary syndromes (ACS). NEOMINDSET is a multicentre, randomised, open-label trial with a blinded outcome assessment designed to compare SAPT versus DAPT in 3,400 ACS patients undergoing PCI with the latest-generation drug-eluting stents (DES). After successful PCI and up to 4 days following hospital admission, patients are randomised to receive SAPT with a potent P2Y12 inhibitor (ticagrelor or prasugrel) or DAPT (aspirin plus a potent P2Y12 inhibitor) for 12 months. Aspirin is discontinued immediately after randomisation in the SAPT group. The choice between ticagrelor and prasugrel is at the investigator's discretion. The primary hypothesis is that SAPT will be non-inferior to DAPT with respect to the composite endpoint of all-cause mortality, stroke, myocardial infarction or urgent target vessel revascularisation, but superior to DAPT on rates of bleeding defined by Bleeding Academic Research Consortium 2, 3 or 5 criteria. NEOMINDSET is the first study that is specifically designed to test SAPT versus DAPT immediately following PCI with DES in ACS patients. This trial will provide important insights on the efficacy and safety of withdrawing aspirin in the early phase of ACS. (ClinicalTrials.gov: NCT04360720).


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Ticagrelor/uso terapêutico , Síndrome Coronariana Aguda/tratamento farmacológico , Síndrome Coronariana Aguda/cirurgia , Cloridrato de Prasugrel/uso terapêutico , Intervenção Coronária Percutânea/efeitos adversos , Quimioterapia Combinada , Aspirina/uso terapêutico , Hemorragia/induzido quimicamente , Resultado do Tratamento
18.
Ren Fail ; 45(1): 2224888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37350345

RESUMO

BACKGROUND: Candidates for transcatheter aortic valve implantation (TAVI) are currently evaluated using computed tomography angiography and invasive cardiac catheterization as an essential part of case selection and pre-procedure interventional planning. However, both imaging methods utilize iodinated agents, which may cause contrast-induced nephropathy, particularly in patients with baseline renal dysfunction. This study aimed to describe a zero-contrast imaging protocol for pre-TAVI evaluation in patients with advanced renal impairment. METHODS: The pre-TAVI zero-contrast scheme consisted of the following multi-modality combinations: (1) gadolinium-free magnetic resonance imaging (three-dimensional navigator-echo with electrocardiogram-gated steady-state free-precession series); (2) iodinated-free multislice computed tomography electrocardiogram-gated; (3) lower limb arterial duplex scan ultrasound; and (4) transesophageal echocardiography. Ultimately, TAVI was performed for those deemed good candidates, and contrast was allowed during the intervention; however, operators were strongly advised to utilize the least volume possible of iodinated agents. This pilot survey included ten patients with symptomatic aortic stenosis and renal dysfunction who underwent zero-contrast multi-modality imaging. RESULTS: All the patients ultimately underwent TAVI. The intervention was successful in all cases, without ≥ moderate residual aortic regurgitation, prosthesis embolization, annulus rupture, major vascular complications, stroke, or death during index hospitalization. The creatinine clearance remained stable throughout the observation period (baseline: 26.85 ± 12.55 mL/min; after multi-modality imaging: 26.76 ± 11.51 mL/min; post-TAVI at discharge: 29.84 ± 13.98 mL/min; p = 0.3 all). CONCLUSION: The proposed contrast-free imaging protocol appears to be a promising clinical tool for pre-TAVI evaluation in patients with severe renal dysfunction.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores , Cateterismo Cardíaco/métodos
19.
Arq Bras Cardiol ; 120(6): e20220594, 2023.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37255134

RESUMO

BACKGROUND: The current gold standard of coronary drug-eluting stents (DES) consists of metal alloys with thinner struts and bioresorbable polymers. OBJECTIVES: Our aim was to compare an ultrathin strut, sirolimus-eluting stent (Inspiron®) with other third-generation DES platforms in patients with ST-elevation myocardial infarction (STEMI) submitted to primary percutaneous coronary intervention (PCI). METHODS: We analyzed data from a STEMI multicenter registry from reference centers in the South Region of Brazil. All patients were submitted to primary PCI, either with Inspiron® or other second- or third-generation DES. Propensity score matching (PSM) was computed to generate similar groups (Inspiron® versus other stents) in relation to clinical and procedural characteristics. All hypothesis tests had a two-sided significance level of 0.05. RESULTS: From January 2017 to January 2021, 1711 patients underwent primary PCI, and 1417 patients met our entry criteria (709 patients in the Inspiron® group and 708 patients in the other second- or third-generation DES group). After PSM, the study sample was comprised of 706 patients (353 patients in the Inspiron® group and 353 patients in the other the other second- or third-generation DES group). The rates of target vessel revascularization (OR 0.52, CI 0.21 - 1.34, p = 0.173), stent thrombosis (OR 1.00, CI 0.29 - 3.48, p = 1.000), mortality (HR 0.724, CI 0.41 - 1.27, p = 0.257), and major cardiovascular outcomes (OR 1.170, CI 0.77 - 1.77, p = 0.526) were similar between groups after a median follow-up of 17 months. CONCLUSION: Our findings show that Inspiron® was effective and safe when compared to other second- or third-generation DES in a contemporary cohort of real-world STEMI patients submitted to primary PCI.


FUNDAMENTO: O padrão-ouro atual dos stents farmacológicos (SF) coronários consiste em ligas metálicas com hastes mais finas e polímeros bioabsorvíveis. OBJETIVOS: Nosso objetivo foi comparar um stent eluidor de sirolimus de hastes ultrafinas (Inspiron®) com outras plataformas de SF de terceira geração em pacientes com infarto do miocárdio com supradesnivelamento do segmento ST (IAMCSST) submetidos à intervenção coronária percutânea (ICP) primária. MÉTODOS: Analisamos dados de um registro multicêntrico de IAMCSST de centros de referência da Região Sul do Brasil. Todos os pacientes foram submetidos à ICP primária, seja com Inspiron® ou outro SF de segunda ou terceira geração. Foi calculado pareamento por escore de propensão (PEP) para gerar grupos semelhantes (Inspiron® versus outros stents) em relação às características clínicas e do procedimento. Todos os testes de hipótese tiveram um nível de significância bilateral de 0,05. RESULTADOS: De janeiro de 2017 a janeiro de 2021, 1.711 pacientes foram submetidos à ICP primária, e 1.417 pacientes preencheram nossos critérios de inclusão (709 pacientes no grupo Inspiron® e 708 pacientes no grupo dos outros SF de segunda ou terceira geração). Após PEP, a amostra do estudo foi composta por 706 pacientes (353 pacientes no grupo Inspiron® e 353 pacientes no grupo dos demais SF de segunda ou terceira geração). As taxas de revascularização do vaso alvo (odds ratio [OR] 0,52; intervalo de confiança [IC] 0,21 a 1,34; p = 0,173), trombose de stent (OR 1,00; IC 0,29 a 3,48;p = 1,000), mortalidade (hazard ratio 0,724; IC 0,41 a 1,27; p = 0,257) e os desfechos cardiovasculares maiores (OR 1,170; IC 0,77 a 1,77; p = 0,526) foram semelhantes entre os grupos após um acompanhamento mediano de 17 meses. CONCLUSÃO: Nossos achados mostram que o stent Inspiron® foi eficaz e seguro quando comparado a outros SF de segunda ou terceira geração em uma coorte contemporânea do mundo real de pacientes com IAMCSST submetidos à ICP primária.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Sirolimo , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Resultado do Tratamento , Stents , Sistema de Registros , Desenho de Prótese
20.
Catheter Cardiovasc Interv ; 101(6): 1036-1044, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37017418

RESUMO

BACKGROUND: Isolate features of the coronary anatomy have been associated with the pathophysiology of atherosclerotic disease. Computational methods have been described to allow precise quantification of the complex three-dimensional (3D) coronary geometry. The present study tested whether quantitative parameters that describe the spatial 3D coronary geometry is associated with the extension and composition of the underlying coronary artery disease (CAD). METHODS: Patients with CAD scheduled for percutaneous intervention were investigated with coronary computed tomography angiography (CCTA), and invasive coronary angiography, and virtual histology intravascular ultrasound (IVUS-VH). For all target vessels, 3D centerlines were extracted from CCTA images and processed to quantify 23 geometric indexes, grouped into 3 main categories as follows: (i) length-based; (ii) curvature-based, torsion-based, and curvature/torsion-combined; (iii) vessel path-based. The geometric variables were compared with IVUS-VH parameters assessing the extent and composition of coronary atherosclerosis. RESULTS: A total of 36 coronary patients (99 vessels) comprised the study population. From the 23 geometric indexes, 18 parameters were significantly (p < 0.05) associated with at least 1 IVUS-VH parameter at a univariate analysis. All three main geometric categories provided parameters significantly related with atherosclerosis variables. The 3D geometric indexes were associated with the degree of atherosclerotic extension, as well as with plaque composition. Geometric features remained significantly associated with all IVUS-VH parameters even after multivariate adjustment for clinical characteristics. CONCLUSIONS: Quantitative 3D vessel morphology emerges as a relevant factor associated with atherosclerosis in patients with established CAD.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento , Doença da Artéria Coronariana/patologia , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...