Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Condens Matter ; 21(26): 264012, 2009 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21828460

RESUMO

A one-dimensional silver (Ag) nanoparticle gradient layer is prepared from an aqueous colloidal solution upon a polystyrene (PS) coated silicon (Si) substrate. For preparation two walls of different wettability are used. The 40 nm PS-layer exhibits a locally constant film thickness due to the strong roughness correlation with the underlying Si-substrate and is less wettable as compared to the glass plate placed above. The Ag nanoparticles have a triangular prism-like shape. The structural characterization of the obtained complex gradient formed by drying is performed with microbeam grazing incidence small-angle x-ray scattering based on compound refractive lenses. Due to the adsorption from aqueous solution in the selective geometry a double gradient type structure defined by two areas with characteristic lateral lengths and a cross-over regime between both is observed.

2.
Rev Sci Instrum ; 78(7): 073702, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17672761

RESUMO

We have designed and built a compact x-ray microtomography system to perform element mapping and absorption imaging by exploiting scanning fluorescence tomography and full-field transmission microtomography, respectively. It is based on a low power microfocus tube and is potentially appropriate for x-ray diagnostics in space. Full-field transmission tomography yields the three-dimensional inner structure of an object. Fluorescence microtomography provides the element distribution on a virtual section through the sample. Both techniques can be combined for appropriate samples. Microradiography as well as fluorescence mapping are also possible. For fluorescence microtomography a small and intensive microbeam is required. It is generated using a polycapillary optic. Operating the microfocus tube with a molybdenum target at 12 W, a microbeam with a full width at half maximum lateral extension of 16 microm and a flux of about 10(8) photonss is generated. As an example of application, this beam is used to determine the element distribution inside dried plant samples. For full-field scanning tomography, the x-ray optic is removed and the sample is imaged in magnifying projection onto a two-dimensional position sensitive detector. Depending on the sample size, a spatial resolution down to about 10 microm is possible in this mode. The method is demonstrated by three-dimensional imaging of a rat humerus.


Assuntos
Absorciometria de Fóton/instrumentação , Tomografia por Raios X/instrumentação , Absorciometria de Fóton/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Phys Rev Lett ; 94(5): 054802, 2005 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-15783651

RESUMO

We address the question of what is the smallest spot size that hard x rays can be focused to using refractive optics. A thick refractive x-ray lens is considered, whose aperture is gradually (adiabatically) adapted to the size of the beam as it converges to the focus. These adiabatically focusing lenses are shown to have a relatively large numerical aperture, focusing hard x rays down to a lateral size of 2 nm (FWHM), well below the theoretical limit for focusing with waveguides [C. Bergemann, Phys. Rev. Lett.912003204801].

4.
Naturwissenschaften ; 88(6): 249-60, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11544952

RESUMO

Highly brilliant synchrotron radiation sources have opened up the possibility of using coherent X-rays in spectroscopy and imaging. Coherent X-rays are characterized by a large lateral coherence length. Speckle spectroscopy is extended to hard X-rays, improving the resolution to the nm range. It has become possible to image opaque objects in phase contrast with a sensitivity far superior to imaging in absorption contrast. All the currently available X-ray sources are chaotic sources. Their characterization in terms of coherence functions of the first and second order is introduced. The concept of coherence volume, defined in quantum optics terms, is generalized for scattering experiments. When the illuminated sample volume is smaller than the coherence volume, the individuality of the defect arrangement in a sample shows up as speckle in the scattered intensity. Otherwise, a configurational average washes out the speckle and only diffuse scattering and possibly Bragg reflections will survive. The loss of interference due to the finite detection time, to the finite detector pixel size and to uncontrolled degrees of freedom in the sample is discussed at length. A comparison between X-ray scattering, neutron scattering and mesoscopic electron transport is given. A few examples illustrate the possibilities of coherent X-rays for imaging and intensity correlation spectroscopy.


Assuntos
Física/métodos , Radiação , Raios X , Animais , Insetos , Fótons , Síncrotrons
5.
Phys Rev Lett ; 85(24): 5186-9, 2000 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-11102217

RESUMO

We investigate the coupling between individual tubes in a rope of single-wall carbon nanotubes using four probe resistance measurements. By introducing defects through the controlled sputtering of the rope we generate a strong nonmonotonic temperature dependence of the four terminal resistance. This behavior reflects the interplay between localization in the intentionally damaged tubes and coupling to undamaged tubes in the same rope. Using a simple model we obtain the coherence length and the coupling resistance. The coupling mechanism is argued to involve direct tunneling between tubes.

6.
Appl Opt ; 37(4): 653-62, 1998 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18268637

RESUMO

Compound lenses made from low-Z materials (e.g., Be, B, C, and Al) set up as a linear array of refractive lenses are proposed for submicrometer focusing of high-energy x rays (>5 keV) in one or two dimensions. A theory of focusing based on Maxwell's equation and the Fresnel-Kirchhoff approach is presented. Compound refractive lenses were manufactured by drilling into an Al block a linear array of 200 closely spaced holes 0.5 mm in diameter for linear focusing and two crossed arrays of 100 holes each for point focusing. Focal spots of 3.7 mum and 8 mum x 18 mum were obtained at 30 keV for linear and two-dimensional lenses, respectively. Different technologies of manufacturing and possible applications of the proposed lenses are discussed.

11.
Phys Rev B Condens Matter ; 46(12): 7953-7956, 1992 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-10002548
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...