1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 3610-3613, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269077

RESUMO

Raman spectroscopy of biological tissue presents fluorescence background, an undesirable effect that generates false Raman intensities. This paper proposes the application of the Empirical Mode Decomposition (EMD) method to baseline correction. EMD is a suitable approach since it is an adaptive signal processing method for nonlinear and non-stationary signal analysis that does not require parameters selection such as polynomial methods. EMD performance was assessed through synthetic Raman spectra with different signal to noise ratio (SNR). The correlation coefficient between synthetic Raman spectra and the recovered one after EMD denoising was higher than 0.92. Additionally, twenty Raman spectra from skin were used to evaluate EMD performance and the results were compared with Vancouver Raman algorithm (VRA). The comparison resulted in a mean square error (MSE) of 0.001554. High correlation coefficient using synthetic spectra and low MSE in the comparison between EMD and VRA suggest that EMD could be an effective method to remove fluorescence background in biological Raman spectra.


Assuntos
Processamento de Sinais Assistido por Computador , Análise Espectral Raman/métodos , Algoritmos , Fluorescência , Humanos , Razão Sinal-Ruído , Pele/química