Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Nucl Med Technol ; 42(4): 292-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25342185

RESUMO

UNLABELLED: In accord with as-low-as-reasonably-achievable and good-manufacturing-practice concepts, the present study evaluated the efficiency of radioactivity decontamination of materials commonly used in laboratory surfaces and whether solvent spills on these materials affect the findings. METHODS: Four materials were evaluated: stainless steel, a surface comprising one-third acrylic resin and two-thirds natural minerals, an epoxy cover, and vinyl-based multipurpose flooring. Radioactive material was eluted from a (99)Mo/(99m)Tc generator, and samples of the surfaces were control-contaminated with 37 MBq (100 µL) of this eluate. The same procedure was repeated with samples of surfaces previously treated with 4 solvents: methanol, methyl ethyl ketone, acetone, and ethanol. The wet radioactive contamination was allowed to dry and then was removed with cotton swabs soaked in soapy water. The effectiveness of decontamination was defined as the percentage of activity removed per cotton swab, and the efficacy of decontamination was defined as the total percentage of activity removed, which was obtained by summing the percentages of activity in all the swabs required to complete the decontamination. RESULTS: Decontamination using our protocol was most effective and most efficacious for stainless steel and multipurpose flooring. Moreover, treatment with common organic solvents seemed not to affect the decontamination of these surfaces. Decontamination of the other two materials was less efficient and was interfered with by the organic solvents; there was also great variability in the overall results obtained for these other two materials. CONCLUSION: In expanding our laboratory, it is possible for us to select those surface materials on which our decontamination protocol works best.


Assuntos
Descontaminação/métodos , Laboratórios , Radioisótopos/isolamento & purificação , Composição de Medicamentos , Controle de Qualidade , Radioatividade , Radioisótopos/química , Propriedades de Superfície
2.
Appl Radiat Isot ; 82: 322-4, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24140984

RESUMO

[(99m)Tc]pentetate ([(99m)Tc]DTPA) is the most commonly used radiopharmaceutical renography agent. The aim of this work was to validate an alternative method for assessing [(99m)Tc]DTPA radiochemical purity (RCP), according to the ICH Q2(R1) guidance: "Validation of Analytical Procedures". The proposed method is composed of two chromatographic systems. System A is a miniaturized system of thin layer chromatography (TLC) silica gel impregnated aluminum strips as stationary phase (SP) and distilled water as mobile phase (MP). System B consists of Whatman 1 paper strips as SP and methyl ethyl ketone as MP. Results indicate that the proposed RCP method has been validated, as it is specific, precise, accurate, linear and robust. Therefore, it can be used as an alternative method for RCP quality control purposes and as stability indicator as well.


Assuntos
Compostos Radiofarmacêuticos/normas , Pentetato de Tecnécio Tc 99m/normas , Butanonas , Cromatografia em Papel/métodos , Cromatografia em Papel/normas , Cromatografia em Camada Fina/métodos , Cromatografia em Camada Fina/normas , Estabilidade de Medicamentos , Humanos , Controle de Qualidade , Renografia por Radioisótopo
3.
J Nucl Med Technol ; 40(4): 271-4, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23024339

RESUMO

UNLABELLED: The aim of the present work was to validate a paper chromatography system as an alternative way to determine the radiochemical purity of Na(18)F. METHODS: The evaluated parameters were specificity, limit of quantification, measurement interval, linearity, precision, accuracy, and robustness. RESULTS: The proposed method proved to be linear (P > 0.05; r(2) = 1.000), precise (relative SD, 8.6%), accurate (mean recovery, 95.9%; relative SD, 1.5%-1.8%), and robust under different conditions since no influence of the operative variables on the chromatographic performance was observed. CONCLUSION: This system can be used as a reliable alternative method to determine the radiochemical purity of Na(18)F samples that can be easily performed in PET radiopharmacies at low cost.


Assuntos
Cromatografia em Papel/métodos , Radioisótopos de Flúor , Radioquímica/métodos , Fluoreto de Sódio/análise , Fluoreto de Sódio/química , Fenômenos Químicos , Controle de Qualidade
4.
Rev. med. nucl. Alasbimn j ; 14(54)oct. 2011. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-609895

RESUMO

El objetivo consistió en evaluar la utilidad del 99mTc-MIBI como marcador para diagnóstico y seguimiento de la progresión tumoral del NMSC en un modelo de carcinogénesis completa en ratones. Los animales en estudio fueron inyectados con 99mTc-MIBI a diferentes tiempos y eutanasiados. Se disecaron muestras de tumor y piel sana para evaluar la captación del radiofármaco y realizar el diagnóstico histológico. En animales con 22 semanas de progresión tumoral se observó una diferencia significativa en la captación del 99mTc-MIBI entre piel sana y NMSC. El protocolo que mejor se adapta al uso del 99mTc-MIBI como marcador para el diagnóstico y seguimiento de la progresión tumoral en ratones portadores de NMSC inducidos es la administración i.v de 1 mCi de 99mTc-MIBI con adquisición de datos a los 30 minutos post inyección. Se observó que a medida que los tumores progresan, la captación de 99mTc-MIBI disminuye respecto a la piel normal.


The aim of the work was to evaluate the usefulness of 99mTc-MIBI as a tracer for the tumor diagnosis and progression of NMSC in a chemically induced model in mice. After administration of 99mTc-MIBI animals were sacrificed at different times. Samples of tumor and healthy skin were dissected in order to perform histological analysis and to evaluate 99mTc-MIBI uptake. Animals under 22 weeks of tumor evolution showed a statistically difference in 99mTc-MIBI uptake between healthy skin and NMSC. Our results showed that the better protocol for the study of the tumor diagnosis and progression of NMSC in mice is the administration of 1 mCi of 99mTc-MIBI and acquisition of images 30 minutes post injection. Results showed that, as tumor progresses, the uptake of 99mTc-MIBI is significantly lower than healthy skin.


Assuntos
Animais , Camundongos , Neoplasias Cutâneas , Compostos Radiofarmacêuticos , Distribuição Tecidual , Fatores de Tempo , Modelos Animais de Doenças , Compostos Radiofarmacêuticos/farmacocinética , /farmacocinética
5.
Rev. med. nucl. Alasbimn j ; 10(39)Jan. 2008.
Artigo em Espanhol | LILACS | ID: lil-480514

RESUMO

Objetivo: Evaluar la biodistribución de 99mTc-GR en un modelo animal de anemia ferropénica. Materiales y métodos: Se utilizaron ratas alimentadas con dietas con diferente contenido de Fe: grupo A (anemia severa, 6.5 ppm), grupo B (anemia moderada, 18 ppm) y grupo C (control, 100 ppm). Se realizó la marcación in vivo de los 99mTc-GR y se evaluó la EBM y su biodistribución a los 30 minutos y a las 24 horas en sangre, hígado, bazo, tracto gastrointestinal, riñones, corazón y pulmones. Los resultados se expresaron como concentración de actividad porcentual (CA por ciento). Resultados: En todos los grupos la EBM fue superior al 98 por ciento. Se observó un aumento de CA por ciento en bazo a las 24 horas en el grupo A, acompañado de una disminución de la CA por ciento del pool sanguíneo posiblemente por aumento del secuestro esplénico de los GR. En los tres grupos hubo un aumento de la CA por ciento en riñón a las 24 horas. Conclusión: La biodistribución de 99mTc-GR se ve modificada en la anemia ferropénica.


Aim: To evaluate the biodistribution of 99mTc-RBC in an animal model of ferropenic anemia. Materials and methods: We used rats which were fed with different iron contents diets: group A (severeanemia, 6.5 ppm), group B (moderate anemia, 18 ppm) and group C (control, 100 ppm). We performed the in vivo labeling of RBC and evaluated the labeling efficiency and the biodistribution at 30 minutes and 24 hours in blood, liver, spleen, gastrointestinal tract, kidneys, heart and lungs. The results were expressed as activity concentration percentage (CA percent). Results: In all groups the labeling efficiency was higher than 98 percent. We observed an increase of CA percent in spleen at 24 hours in the group A, followed by a decrease of CA percent in blood. This could be a consequence of an increase of splenic uptake of RBC. An increase in CA percent in kidney was obtained at 24 hours for all the groups. Conclusion: An alteration in the RBC biodistribution is observed in an animal model of ferropenic anemia.


Assuntos
Animais , Feminino , Ratos , Anemia Ferropriva , Anemia Ferropriva/metabolismo , Compostos de Tecnécio , Eritrócitos/metabolismo , Tecnécio , Compostos de Tecnécio/farmacocinética , Distribuição Tecidual , Fatores de Tempo , Modelos Animais de Doenças , Ratos Sprague-Dawley , Tecnécio/farmacocinética
6.
Nucl Med Biol ; 33(4): 581-4, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16720252

RESUMO

The distribution of colloids and labeled cells in organs is influenced by their intrinsic properties and by the state of the investigated subject. Iron deficiency remains an unsolved nutritional problem all over the world; one of its severe consequences is anemia. Because iron metabolism principally takes place in the liver, spleen, bone marrow, skeletal muscle and blood, we studied the effect of iron deficiency anemia on the biodistribution of 99mTc phytate, 99mTc gelatin colloid and 99mTc RBC (red blood cells labeled with 99mTc). Our results show that iron deficiency anemia modifies the pattern of biodistribution of the two colloids assayed. However, this behavior is different for both of them. This work contributes to studies that kinetically and statistically establish that iron deficiency anemia induces a significant inversion in the spleen-liver activity relationship when centellographic studies are performed with colloids such as 99mTc phytate.


Assuntos
Anemia Ferropriva/diagnóstico por imagem , Anemia Ferropriva/metabolismo , Tecnécio/farmacocinética , Animais , Fígado/diagnóstico por imagem , Fígado/metabolismo , Masculino , Taxa de Depuração Metabólica , Especificidade de Órgãos , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Sprague-Dawley , Baço/diagnóstico por imagem , Baço/metabolismo , Distribuição Tecidual
7.
J Nucl Med Technol ; 33(4): 234-7, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16322125

RESUMO

OBJECTIVE: Exogenous natural surfactant (ENS) labeled with 99mTc shows an elevated lung specificity allowing the acquisition of high-quality images for ventilation scintigraphy. METHODS: The methods for 99mTc-ENS quality control (physical properties, pH determination, radiochemical studies, and biologic studies) were evaluated and validated. RESULTS: The physical properties of the nonradioactive precursor and of the radiopharmaceutical were analyzed as general descriptors of the product. The pH of the radiopharmaceutical was determined by using pH test papers, a method described and validated in the United States Pharmacopeia. Chromatographic studies performed using the acetone/Whatman-1 paper system were validated as a method to evaluate the radiochemical purity of the 99mTc-ENS. Biodistribution studies on rats after intratracheal administration were validated as a method to estimate the radiopharmaceutical biodistribution in humans. CONCLUSION: The proposed method for 99mTc-ENS quality control studies and stability studies was evaluated and validated following international standards.


Assuntos
Marcação por Isótopo/métodos , Pulmão/metabolismo , Surfactantes Pulmonares/farmacocinética , Tecnécio/farmacocinética , Animais , Avaliação Pré-Clínica de Medicamentos/métodos , Avaliação Pré-Clínica de Medicamentos/normas , Marcação por Isótopo/normas , Pulmão/diagnóstico por imagem , Taxa de Depuração Metabólica , Especificidade de Órgãos , Surfactantes Pulmonares/análise , Surfactantes Pulmonares/normas , Controle de Qualidade , Cintilografia , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/normas , Ratos , Ratos Sprague-Dawley , Tecnécio/análise , Tecnécio/normas , Distribuição Tecidual
8.
Biol Trace Elem Res ; 94(1): 73-8, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12907829

RESUMO

The iron bioavailability and acute oral toxicity in rats of a ferrous gluconate compound stabilized with glycine (SFG), designed for food fortification, was studied in this work by means of the prophylactic method and the Wilcoxon method, respectively. For the former studies, SFG was homogeneously added to a basal diet of low iron content, reaching a final iron concentration of 20.1 +/- 2.4 mg Fe/kg diet. A reference standard diet using ferrous sulfate as an iron-fortifying source (19.0 +/- 2.1 mg Fe/kg diet) and a control diet without iron additions (9.3 +/- 1.4 mg Fe/kg diet) were prepared in the laboratory in a similar way. These diets were administered to three different groups of weaning rats during 23 d as the only type of solid nourishment. The iron bioavailability of SFG was calculated as the relationship between the mass of iron incorporated into hemoglobin during the treatment and the total iron intake per animal. This parameter resulted in 36.6 +/- 6.2% for SFG, whereas a value of 35.4 +/- 8.0% was obtained for ferrous sulfate. The acute toxicological studies were performed in two groups of 70 female and 70 male Sprague-Dawley rats that were administered increasing doses of iron from SFG. The LD50 values of 1775 and 1831 mg SFG/kg body wt were obtained for female and male rats, respectively, evidencing that SFG can be considered as a safe compound from a toxicological point of view.


Assuntos
Compostos Ferrosos/metabolismo , Compostos Ferrosos/toxicidade , Alimentos Fortificados/toxicidade , Ferro/metabolismo , Animais , Disponibilidade Biológica , Feminino , Masculino , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA