Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Eng Phys ; 37(4): 361-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25666402

RESUMO

Integration of biological samples into in vitro mock loops is fundamental to simulate real device's operating conditions. We developed an in vitro platform capable of simulating the pumping function of the heart through the external pressurization of the ventricle. The system consists of a fluid-filled chamber, in which the ventricles are housed and sealed to exclude the atria from external loads. The chamber is connected to a pump that drives the motion of the ventricular walls. The aorta is connected to a systemic impedance simulator, and the left atrium to an adjustable preload. The platform reproduced physiologic hemodynamics, i.e. aortic pressures of 120/80 mmHg with 5 L/min of cardiac output, and allowed for intracardiac endoscopy. A pilot study with a left ventricular assist device (LVAD) was also performed. The LVAD was connected to the heart to investigate aortic valve functioning at different levels of support. Results were consistent with the literature, and high speed video recordings of the aortic valve allowed for the visualization of the transition between a fully opening valve and a permanently closed configuration. In conclusion, the system showed to be an effective tool for the hemodynamic assessment of devices, the simulation of surgical or transcatheter procedures and for visualization studies.


Assuntos
Equipamentos e Provisões , Ventrículos do Coração , Modelos Cardiovasculares , Animais , Valva Aórtica/fisiologia , Desenho de Equipamento , Coração Auxiliar , Hemodinâmica , Valva Mitral/fisiologia , Movimento (Física) , Projetos Piloto , Pressão , Suínos , Função Ventricular , Gravação em Vídeo
2.
J Biomech ; 47(2): 329-33, 2014 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-24360769

RESUMO

Aortic interleaflet triangle reshaping (AITR) is a surgical approach to aortic valve incontinence that involves placing three stitches at half of the interleaflet triangles height. In this work, the relationship between the actual stitch height and valve functioning, and the safety margin that the surgeon can rely on in applying the stitches were systematically investigated in vitro. AITR surgery was applied to six swine aortic roots placing the stitches empirically at 50%, 60% and 75% of the triangle heights. Then the actual stitch heights were measured and the hydrodynamic performances were evaluated with a pulsatile hydrodynamic mock loop. Actual stitch heights were 45±2%, 61±4% and 79±6%. As compared to untreated conditions, the 50% configuration induced a significant variation in the effective orifice area. With stitches placed at 60%, the mean systolic pressure drop increased significantly with respect to the untreated case, but no significant changes were recorded with respect to the 50% configuration. At 75%, all the hydrodynamic parameters of systolic valve functioning worsened significantly. Summarizing, the AITR technique, when performed in a conservative manner did not induce significant alterations in the hydrodynamics of the aortic root in vitro, while more aggressive configurations did. The absence of a statistically significant difference between the 50% and 60% configurations suggests that there is a reasonably limited risk of inducing valve stenosis in the post-op scenario due to stitch misplacement.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Animais , Valva Aórtica/fisiologia , Pressão Sanguínea , Humanos , Hidrodinâmica , Técnicas In Vitro , Técnicas de Sutura , Suínos
3.
J Biomech ; 45(7): 1133-9, 2012 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-22387122

RESUMO

Due to their high complexity, surgical approaches to valve repair may benefit from the use of in vitro simulators both for training and for the investigation of those measures which can lead to better clinical results. In vitro tests are intrinsically more effective when all the anatomical substructures of the valvular complexes are preserved. In this work, a mock apparatus able to house an entire explanted porcine heart and subject it to pulsatile fluid-dynamic conditions was developed, in order to enable the hemodynamic analysis of simulated surgical procedures and the imaging of the valvular structures. The mock loop's hydrodynamic design was based on an ad-hoc defined lumped-parameter model. The left ventricle of an entire swine heart was dynamically pressurized by an external computer-controlled pulse duplicator. The ascending aorta was connected to a hydraulic circuit which simulated the input impedance of the systemic circulation; a reservoir passively filled the left atrium. Accesses for endoscopic imaging were located in the apex of the left ventricle and in the aortic root. The experimental pressure and flow tracings were comparable with the typical in vivo curves; a mean flow of 3.5±0.1l pm and a mean arterial pressure of 101±2 mmHg was obtained. High-quality echographic and endoscopic video recordings demonstrated the system's excellent potential in the observation of the cardiac structures dynamics. The proposed mock loop represents a suitable in vitro system for the testing of minimally-invasive cardiovascular devices and surgical procedures for heart valve repair.


Assuntos
Valvas Cardíacas/fisiologia , Valvas Cardíacas/cirurgia , Animais , Fenômenos Biomecânicos , Simulação por Computador , Hemodinâmica , Hidrodinâmica , Técnicas In Vitro , Modelos Animais , Modelos Cardiovasculares , Sus scrofa , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA