Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
1.
Eur Radiol ; 34(4): 2426-2436, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37831139

RESUMO

OBJECTIVES: Coronary computed tomography angiography (CCTA) has higher diagnostic accuracy than coronary artery calcium (CAC) score for detecting obstructive coronary artery disease (CAD) in patients with stable chest pain, while the added diagnostic value of combining CCTA with CAC is unknown. We investigated whether combining coronary CCTA with CAC score can improve the diagnosis of obstructive CAD compared with CCTA alone. METHODS: A total of 2315 patients (858 women, 37%) aged 61.1 ± 10.2 from 29 original studies were included to build two CAD prediction models based on either CCTA alone or CCTA combined with the CAC score. CAD was defined as at least 50% coronary diameter stenosis on invasive coronary angiography. Models were built by using generalized linear mixed-effects models with a random intercept set for the original study. The two CAD prediction models were compared by the likelihood ratio test, while their diagnostic performance was compared using the area under the receiver-operating-characteristic curve (AUC). Net benefit (benefit of true positive versus harm of false positive) was assessed by decision curve analysis. RESULTS: CAD prevalence was 43.5% (1007/2315). Combining CCTA with CAC improved CAD diagnosis compared with CCTA alone (AUC: 87% [95% CI: 86 to 89%] vs. 80% [95% CI: 78 to 82%]; p < 0.001), likelihood ratio test 236.3, df: 1, p < 0.001, showing a higher net benefit across almost all threshold probabilities. CONCLUSION: Adding the CAC score to CCTA findings in patients with stable chest pain improves the diagnostic performance in detecting CAD and the net benefit compared with CCTA alone. CLINICAL RELEVANCE STATEMENT: CAC scoring CT performed before coronary CTA and included in the diagnostic model can improve obstructive CAD diagnosis, especially when CCTA is non-diagnostic. KEY POINTS: • The combination of coronary artery calcium with coronary computed tomography angiography showed significantly higher AUC (87%, 95% confidence interval [CI]: 86 to 89%) for diagnosis of coronary artery disease compared to coronary computed tomography angiography alone (80%, 95% CI: 78 to 82%, p < 0.001). • Diagnostic improvement was mostly seen in patients with non-diagnostic C. • The improvement in diagnostic performance and the net benefit was consistent across age groups, chest pain types, and genders.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Feminino , Humanos , Masculino , Cálcio , Dor no Peito/diagnóstico , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Idoso
2.
Eur Radiol ; 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38148406

RESUMO

OBJECTIVES: The purpose of this meta-analysis was to determine the diagnostic performance of conventional MRI and MR arthrography for tendinosis, and partial and complete tears of the long head of the biceps tendon (LHBT) using arthroscopy as the reference standard. MATERIALS AND METHODS: A systematic review was performed using predefined data fields in PubMed, and all articles published from January 2000 up to April 2022 were retrospectively pooled and reviewed. Six MRI studies on complete tear (n = 555) and ten studies on partial tear/tendinosis (n = 2487) were included in the analysis. Two of the included studies in each group investigated the use of MR arthrography. The data sets were analyzed using a univariate approach with the DerSimonian and Laird random effects model and the proportional hazards model. RESULTS: MRI shows high specificities in diagnosing complete tears of the LHBT ranging from 93.0 to 99.0%. Diagnostic sensitivity was more heterogeneous ranging from 55.9 to 90.0%. The overall negative likelihood ratio was 0.29 (95% CI: 0.17-0.50) and the overall positive likelihood ratio was 37.3 (95% CI: 11.9-117.4). The mean sensitivity in diagnosing partial tear/tendinosis of the LHBT was 67.8% (95% CI: 54.3-78.9%) and the specificity was 75.9% (95% CI: 63.6-85.0%), resulting in a balanced accuracy of 71.9%. The overall negative likelihood ratio was 0.44 (95% CI: 0.32-0.59) and the overall positive likelihood ratio was 2.64 (95% CI: 1.91-3.65). CONCLUSION: MRI is highly specific for the diagnosis of complete tears of the LHBT, whereas diagnostic sensitivity was more heterogeneous. The diagnosis of partial tears and/or tendinosis of the LHBT remains challenging on MRI, which may warrant complementary clinical examination or other imaging modalities to increase diagnostic confidence in equivocal cases. CLINICAL RELEVANCE STATEMENT: Conventional MRI and MR arthrography have high diagnostic performance for complete tendon tear when compared to arthroscopy. The diagnosis of tendinosis/partial tears remains challenging and may require comparison with clinical tests and other imaging modalities. KEY POINTS: •There is no clear consensus regarding the primary imaging modality for the evaluation of LHBT disorders. •Conventional MRI and MR arthrography are highly specific in diagnosing complete tears of the LHBT. •Diagnosis of partial tears/tendinosis of the LHBT on conventional MRI and MR arthrography remains a diagnostic challenge.

3.
J Clin Med ; 12(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37109351

RESUMO

BACKGROUND: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. OBJECTIVE: The evaluation of magnetic resonance imaging (MRI) findings during the most active phase of screw resorption is the objective, with particular focus on the growth plate and to assess for the presence of metal-induced artifacts. MATERIAL AND METHODS: In total, 30 prospectively acquired MRIs from 17 pediatric patients with fractures treated with magnesium screws were assessed for the presence and distribution of intraosseous, extraosseous, and intra-articular gas; gas within the growth plate; osteolysis along the screw; joint effusion; bone marrow edema; periosteal reaction; soft tissue edema; and metal-induced artifacts. RESULTS: Gas locules were found in the bone and soft tissues in 100% of the examinations, intra-articular in 40%, and in 37% of unfused growth plates. Osteolysis and the periosteal reaction were present in 87%, bone marrow edema in 100%, soft tissue edema in 100%, and joint effusion in 50% of examinations. Pile-up artifacts were present in 100%, and geometric distortion in 0% of examinations. Fat suppression was not significantly impaired in any examination. CONCLUSIONS: Gas and edema in the bone and soft tissues are normal findings during the resorption of magnesium screws and should not be misinterpreted as infection. Gas can also be detected within growth plates. MRI examinations can be performed without metal artifact reduction sequences. Standard fat suppression techniques are not significantly affected.

4.
Eur J Radiol ; 156: 110549, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36272226

RESUMO

PURPOSE: To assess the performance of semi-automated volumetry of solid pulmonary nodules on single-energy tin-filtered ultralow dose (ULD) chest CT scans at a radiation dose equivalent to chest X-ray relative to standard dose (SD) chest CT scans and assess the impact of kernel and iterative reconstruction selection. METHODS: Ninety-four consecutive patients from a prospective single-center study were included and underwent clinically indicated SD chest CT (1.9 ± 0.8 mSv) and additional ULD chest CT (0.13 ± 0.01 mSv) in the same session. All scans were reconstructed with a soft tissue (Br40) and lung (Bl64) kernel as well as with Filtered Back Projection (FBP) and Iterative Reconstruction (ADMIRE-3 and ADMIRE-5). One hundred and forty-eight solid pulmonary nodules were identified and analysed by semi-automated volumetry on all reconstructions. Nodule volumes were compared amongst all reconstructions thereby focusing on the agreement between SD and ULD scans. RESULTS: Nodule volumes ranged from 58.5 (28.8-126) mm3 for ADMIRE-5 Br40 ULD reconstructions to 72.5 (39-134) mm3 for FBP Bl64 SD reconstructions with significant differences between reconstructions (p < 0.001). Interscan agreement of volumes between two given reconstructions ranged from ICC = 0.605 to ICC = 0.999. Between SD and ULD scans, agreement of nodule volumes was highest for FBP Br40 (ICC = 0.995), FBP Bl64 (ICC = 0.939) and ADMIRE-5 Bl64 (ICC = 0.994) reconstructions. ADMIRE-3 reconstructions exhibited reduced interscan agreement of nodule volumes (ICCs from 0.788 - 0.882). CONCLUSIONS: The interscan agreement of node volumes between SD and ULD is high depending on the choice of kernel and reconstruction algorithm. However, caution should be exercised when comparing two image series that were not identically reconstructed.

5.
Pediatr Radiol ; 52(13): 2584-2594, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35836016

RESUMO

BACKGROUND: Exposure of the eye lens to ionizing radiation results in cataract. Several dose optimization techniques to protect the lens are available for computed tomography (CT). OBJECTIVE: The radiation dose to the eye lens, volume CT dose index (CTDIvol) and image quality of various methods of dose optimization were evaluated for pediatric head CT: automated tube current modulation (ATCM), automated tube voltage selection (ATVS), organ-based tube current modulation (OBTCM) and bismuth shielding. MATERIALS AND METHODS: An anthropomorphic phantom of a 5-year-old child was scanned with nine protocols: no dose optimization technique and then adding different dose optimization techniques alone and in combination. Dose to the eye, thyroid and breast were estimated using metal oxide semiconductor field effect transistor (MOSFET) dosimetry. CTDIvol, influence of timing of shield placement, image noise and attenuation values in 13 regions of interest of the head and subjective image quality were compared. RESULTS: The eye shield significantly reduced the eye lens dose when used alone, to a similar degree as when using all software-based techniques together. When used in combination with software-based techniques, the shield reduced the eye lens dose by up to 45% compared to the no dose optimization technique. Noise was significantly increased by the shield, most pronounced in the anterior portion of the eye. CONCLUSION: The combination of ATCM, ATVS, OBTCM and a bismuth shield, with the shield placed after acquiring the localizer image, should be considered to reduce the radiation dose to the eye lens in pediatric head CT.


Assuntos
Bismuto , Proteção Radiológica , Criança , Humanos , Pré-Escolar , Doses de Radiação , Proteção Radiológica/métodos , Cabeça/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
6.
Eur J Radiol Open ; 9: 100431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35765661

RESUMO

Purpose: To compare temporal evolution of imaging features of coronavirus disease 2019 (COVID-19) and influenza in computed tomography and evaluate their predictive value for distinction. Methods: In this retrospective, multicenter study 179 CT examinations of 52 COVID-19 and 44 influenza critically ill patients were included. Lung involvement, main pattern (ground glass opacity, crazy paving, consolidation) and additional lung and chest findings were evaluated by two independent observers. Additional findings and clinical data were compared patient-wise. A decision tree analysis was performed to identify imaging features with predictive value in distinguishing both entities. Results: In contrast to influenza patients, lung involvement remains high in COVID-19 patients > 14 days after the diagnosis. The predominant pattern in COVID-19 evolves from ground glass at the beginning to consolidation in later disease. In influenza there is more consolidation at the beginning and overall less ground glass opacity (p = 0.002). Decision tree analysis yielded the following: Earlier in disease course, pleural effusion is a typical feature of influenza (p = 0.007) whereas ground glass opacities indicate COVID-19 (p = 0.04). In later disease, particularly more lung involvement (p < 0.001), but also less pleural (p = 0.005) and pericardial (p = 0.003) effusion favor COVID-19 over influenza. Regardless of time point, less lung involvement (p < 0.001), tree-in-bud (p = 0.002) and pericardial effusion (p = 0.01) make influenza more likely than COVID-19. Conclusions: This study identified differences in temporal evolution of imaging features between COVID-19 and influenza. These findings may help to distinguish both diseases in critically ill patients when laboratory findings are delayed or inconclusive.

7.
Insights Imaging ; 13(1): 91, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35551532

RESUMO

OBJECTIVES: The supraacetabular fossa (SAF) is an anatomical variant of the acetabular roof which may mimic a cartilage defect. Two different subtypes have been described: type 1 fluid-filled and type 2 cartilage-filled. The adult prevalence of SAF was reported between 10.5 and 12.6%. We aimed to determine SAF prevalence in a pediatric and young adult population and examine the potential remodeling of the subtypes over time. METHODS: A retrospective search of the institutional database for hip MRI of participants aged 4-25 years was carried out between 2010 and 2020. A total of 401 eligible MRIs of 323 participants were analyzed by two readers. The documented features were: existence of SAF, definition of subtype and measurements of the SAF in three dimensions. Logistic regression models were calculated to estimate the influence of age on the presence of SAF. RESULTS: Out of 323, 115 (35,6%) participants demonstrated a supraacetabular fossa. 63 (19.5%) participants presented subtype 1 and 51 (15.8%) type 2; one participant had both. The predicted probability for SAF increases until the age of 14, beyond 14 years, the combined predicted probability for both subtypes decreased again. In contrast to SAF type 1, SAF type 2 was more prevalent with older age. The size of the SAF decreased with aging. CONCLUSION: The supraacetabular fossa is most frequent in adolescents. With higher age, the prevalence and the size of the SAF decreased. This data supports the theory that the SAF is a developmental variant.

8.
Diagnostics (Basel) ; 12(5)2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35626356

RESUMO

BACKGROUND: COVID-19 superinfection by Aspergillus (COVID-19-associated aspergillosis, CAPA) is increasingly observed due to increased awareness and use of corticosteroids. The aim of this study is to compare clinical and imaging features between COVID-19 patients with and without associated pulmonary aspergillosis. MATERIAL AND METHODS: In this case-control study, hospitalized patients between March 2020 and March 2021 were evaluated. Two observers independently compared 105 chest CTs of 52 COVID-19 patients without pulmonary aspergillosis to 40 chest CTs of 13 CAPA patients. The following features were evaluated: lung involvement, predominant main pattern (ground glass opacity, crazy paving, consolidation) and additional lung and chest findings. Chronological changes in the abnormal extent upon CT and chronological changes in the main patterns were compared with mixed models. Patient-wise comparisons of additional features and demographic and clinical data were performed using Student's t-test, Chi-squared test, Fisher's exact tests and Wilcoxon rank-sum tests. RESULTS: Compared to COVID-19 patients without pulmonary aspergillosis, CAPA patients were older (mean age (±SD): 70.3 (±7.8) versus 63.5 (±9.5) years (p = 0.01). The time-dependent evolution rates for consolidation (p = 0.02) and ground glass (p = 0.006) differed. In early COVID-19 disease, consolidation was associated with CAPA, whereas ground glass was less common. Chronological changes in the abnormal extent upon CT did not differ (p = 0.29). Regardless of the time point, bronchial wall thickening was observed more frequently in CAPA patients (p = 0.03). CONCLUSIONS: CAPA patients showed a tendency for consolidation in early COVID-19 disease. Bronchial wall thickening and higher patient age were associated with CAPA. The overall lung involvement was similar between both groups.

9.
Front Med (Lausanne) ; 9: 857529, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35433726

RESUMO

Preeclampsia is one of the most dangerous diseases in pregnancy. Because of the hypertensive nature of preeclampsia, placental calcifications are believed to be a predictor for its occurrence, analogous to their role in cardiovascular diseases. However, the prevalence and the relevance of calcifications for the clinical outcome with respect to preeclampsia remains controversial. In addition, the role of other inorganic components present in the placental tissue in the development of preeclampsia has rarely been investigated. In this work, we therefore characterized inorganic constituents in placental tissue in groups of both normotensive and preeclamptic patients (N = 20 each) using a multi-scale and multi-modal approach. Examinations included elemental analysis (metallomics), sonography, computed tomography (CT), histology, scanning electron microscopy, X-ray fluorescence and energy dispersive X-ray spectroscopy. Our data show that tissue contents of several heavy metals (Al, Cd, Ni, Co, Mn, Pb, and As) were elevated whereas the Rb content was decreased in preeclamptic compared to normotensive placentae. However, the median mineral content (Ca, P, Mg, Na, K) was remarkably comparable between the two groups and CT showed lower calcified volumes and fewer crystalline deposits in preeclamptic placentae. Electron microscopy investigations revealed four distinct types of calcifications, all predominantly composed of calcium, phosphorus and oxygen with variable contents of magnesium in tissues of both maternal and fetal origin in both preeclamptic and normotensive placentae. In conclusion our study suggests that heavy metals, combined with other factors, can be associated with the development of preeclampsia, however, with no obvious correlation between calcifications and preeclampsia.

11.
Eur Radiol ; 32(8): 5233-5245, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35267094

RESUMO

OBJECTIVES: There is conflicting evidence about the comparative diagnostic accuracy of the Agatston score versus computed tomography angiography (CTA) in patients with suspected obstructive coronary artery disease (CAD). PURPOSE: To determine whether CTA is superior to the Agatston score in the diagnosis of CAD. METHODS: In total 2452 patients with stable chest pain and a clinical indication for invasive coronary angiography (ICA) for suspected CAD were included by the Collaborative Meta-analysis of Cardiac CT (COME-CCT) Consortium. An Agatston score of > 400 was considered positive, and obstructive CAD defined as at least 50% coronary diameter stenosis on ICA was used as the reference standard. RESULTS: Obstructive CAD was diagnosed in 44.9% of patients (1100/2452). The median Agatston score was 74. Diagnostic accuracy of CTA for the detection of obstructive CAD (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) was significantly higher than that of the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). Among patients with an Agatston score of zero, 17% (101/600) had obstructive CAD. Diagnostic accuracy of CTA was not significantly different in patients with low to intermediate (1 to < 100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). CONCLUSIONS: Results in our international cohort show CTA to have significantly higher diagnostic accuracy than the Agatston score in patients with stable chest pain, suspected CAD, and a clinical indication for ICA. Diagnostic performance of CTA is not affected by a higher Agatston score while an Agatston score of zero does not reliably exclude obstructive CAD. KEY POINTS: • CTA showed significantly higher diagnostic accuracy (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) for diagnosis of coronary artery disease when compared to the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). • Diagnostic performance of CTA was not affected by increased amount of calcium and was not significantly different in patients with low to intermediate (1 to <100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). • Seventeen percent of patients with an Agatston score of zero showed obstructive coronary artery disease by invasive angiography showing absence of coronary artery calcium cannot reliably exclude coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Cálcio , Dor no Peito/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
12.
J Magn Reson Imaging ; 56(5): 1571-1579, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35106870

RESUMO

BACKGROUND: Diagnosis of osteomyelitis by imaging can be challenging. The feasibility of diffusion-weighted imaging (DWI) as ancillary sequence was evaluated in this study. PURPOSE: To evaluate DWI for differentiation between osteomyelitis, bone marrow edema, and healthy bone on forefoot magnetic resonance imaging (MRI). STUDY TYPE: Prospective. SUBJECTS: A total of 60 consecutive patients undergoing forefoot MRI divided into three study groups (20 subjects each): osteomyelitis, bone marrow edema, and healthy bone. FIELD STRENGTH/SEQUENCE: A 1.5T and 3T MRI scanners; readout-segmented multishot echo planar DWI. ASSESSMENT: Two independent radiologists measured apparent diffusion coefficient (ADC) values within abnormal or healthy bone. STATISTICAL TESTS: ADC values were compared between groups (pairwise t-test with Bonferroni-Holm correction for multiple testing). Intraclass correlation coefficient (ICC) was calculated to assess inter-reader agreement. Threshold ADC values were determined as the cutoffs that maximized the sum of sensitivity and specificity. Receiver operating characteristic (ROC) analysis was performed with statistical threshold of P < 0.05. RESULTS: Inter-reader agreement was 0.92 in the healthy bone group and 0.78 in both the edema and osteomyelitis groups. Average ADC values were significantly different between groups: 1432 ± 222 × 10-6  mm2 /sec (osteomyelitis), 1071 ± 196 × 10-6  mm2 /sec (bone marrow edema), and 277 ± 89 × 10-6  mm2 /sec (healthy bone). A threshold ADC value of 534 × 10-6  mm2 /sec distinguishes between healthy and abnormal bone with specificity and sensitivity of 100% each. For distinction between osteomyelitis and bone marrow edema, two cutoff values were determined: a 95%-specificity cutoff indicating osteomyelitis (>1320 × 10-6  mm2 /sec) and a 95%-sensitivity cutoff indicating bone marrow edema (<1155 × 10-6  mm2 /sec). Diagnostic accuracy of 95% was achieved for 73% (29/40) of the subjects. DATA CONCLUSION: DWI with ADC maps distinguishes between healthy and abnormal bone on forefoot MRI. Calculated cutoff values allow confirmation or exclusion of osteomyelitis in a high proportion of subjects. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Doenças da Medula Óssea , Osteomielite , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Doenças da Medula Óssea/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Osteomielite/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade
13.
Skeletal Radiol ; 51(3): 573-579, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34255126

RESUMO

OBJECTIVE: Short tau or short TI inversion recovery (STIR) MRI sequences are considered a robust fat suppression technique. However, STIR also suppresses signals from other tissues with similar T1 relaxation times. This study investigates the in vivo effect of intravenous gadolinium-based T1-shortening contrast agent on STIR signal. MATERIALS AND METHODS: Institutional board approval and informed consent was obtained. MRI examinations (1.5-T or 3-T) of 31 prospectively included patients were analyzed by two readers. Signal intensity of degenerative bone marrow edema-like signal at the Lisfranc joint on precontrast STIR images and on STIR images acquired after intravenous contrast agent administration (gadoteric acid, gadolinium: 0.5 mmol/ml, 15 ml) was measured. The medial cuneiform bone without observable bone marrow edema-like signal was considered a healthy tissue and served as a reference. Relative changes in signal intensity between precontrast and postcontrast images were calculated for the two tissues. Wilcoxon signed-rank test served for statistical analyses. RESULTS: In bone marrow edema-like signal, both readers observed a median signal change of -35% (interquartile range (IQR) 24) and -34% (IQR 21), respectively, on postcontrast STIR images compared to precontrast STIR. In healthy tissue, the signal remained constant on postcontrast STIR images (median change -2%, IQR 15, and 0%, IQR 17) respectively. For both readers, postcontrast signal change in bone marrow edema-like signal differed from that in healthy tissue (p < 0.001). CONCLUSION: Intravenous gadolinium-based contrast agent causes a significant reduction of signal intensity in bone marrow edema-like signal on routine STIR images. Thus, pathological MRI findings may be obscured.


Assuntos
Doenças da Medula Óssea , Meios de Contraste , Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/induzido quimicamente , Doenças da Medula Óssea/diagnóstico por imagem , Edema/induzido quimicamente , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
14.
Acta Radiol ; 63(6): 743-749, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33940960

RESUMO

BACKGROUND: After computed tomography (CT)-guided interventions, routine in-hospital observation is recommended by the Cardiovascular and Interventional Radiological Society of Europe. PURPOSE: To evaluate the frequency of delayed major complications or hospitalizations after CT-guided biopsies in patients with initially no or minor complications and to assess whether routine in-hospital observation is justified. MATERIAL AND METHODS: This retrospective study included 433 outpatients after CT-guided biopsy of the thoracic (n = 176), abdominal (n = 129), or musculoskeletal (n = 128) region with subsequent in-hospital observation. Complications were graded according to the current Society of Interventional Radiology recommendations and grouped into minor or major. A complication that occurred during in-hospital observation was defined as delayed complication. A delayed major complication was a newly developed major complication or a progression from an initially minor to a major complication. Hospitalization frequencies were evaluated similarly. Occurrence, 95% confidence intervals (CI), and P values for significant differences between the three organ groups were calculated. If delayed major complications were more frequent than 1%, routine in-hospital observation was considered justified. RESULTS: Delayed, major complication frequencies were: thoracic, 8.2% (95% CI 4.6-13.4); abdominal, 0.0% (95% CI 0.0-2.9); and musculoskeletal, 0.0% (95% CI 0.0-2.9) (P < 0.001). Delayed hospitalization frequencies were: thoracic, 8.8% (95% CI 5.0-14.2); abdominal, 1.6% (95% CI 0.2-5.6); and musculoskeletal, 0.0% (95% CI 0.0-2.9) (P < 0.001). CONCLUSION: After thoracic interventions, routine observation is considered justified for patient safety whereas routine observation may be omitted after musculoskeletal interventions. In the abdominal group, no delayed complications were observed, but delayed hospitalization occurred. Thus, in-hospital observation could be justified in a safe patient environment, but remains an individual decision.


Assuntos
Biópsia Guiada por Imagem , Radiografia Intervencionista , Hospitais , Humanos , Biópsia Guiada por Imagem/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
15.
J Belg Soc Radiol ; 105(1): 45, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34611579

RESUMO

OBJECTIVES: To determine the effects of reorganizing a radiology institute from decentralized/modality-based to centralized/subspecialized radiology on radiologists, radiologic technicians, and referring physicians at a multi-center radiology network. MATERIAL AND METHODS: In 2017/2018 our multi-center radiology network was changed from decentralized/modality-based to centralized/subspecialized reporting. A survey was conducted among radiologists, technicians and two groups of referring physicians (main hospital and non-main hospitals). The following items were tested: Overall satisfaction, perceived quality of radiological reports, subjective productivity/efficiency, confidence of radiologists in their subspecialty, availability of radiologists and turnaround time. Two of five answering options on a 5-point Likert scale were considered to represent agreement. The Mann-Whitney-U-test served for statistical analyses in agreement before and after reorganization in each group. RESULTS: For radiologists, a significant difference was observed in perceived quality of radiological reports 42/46 (91.3%) compared to 51/52 (98.1%; p = 0.013).For technicians, no significant differences were observed. In the group of main hospital referring physicians, significant differences were observed in overall satisfaction 129/152 (84.9%) compared to 164/174 (94.3%; p < 0.001) and in perceived quality of radiological reports 125/148 (72.8%) compared to 157/170 (92.4%; p = 0.001). In the group of non-main hospital referring physicians no significant differences were observed. CONCLUSION: The reorganization resulted in a significantly higher perceived quality of radiological reports for the groups of radiologists and main hospital referring physicians besides overall satisfaction for main hospital referring physicians. Specialized main hospital referring physicians value reports of specialized radiology, whereas less specialized, non-main hospital referring physicians did not experience any significant effect.

16.
BMC Pediatr ; 21(1): 276, 2021 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-34116649

RESUMO

BACKGROUND: Organ size is influenced by a number of factors. Age, height, weight, and ethnicity are known influencing factors. Pediatric populations have changed over time, puberty beginning earlier resulting in a changing growth pattern of their organs. Hence, contemporary charts using local data are considered the most appropriate for a given population. Sonographic charts for liver size for a predominantly Caucasian population are limited, which has implications for clinical practice. The aim of this study was to define a contemporary normative range of liver and spleen sizes for a healthy, predominantly Caucasian population and for all pediatric age groups (0-18 years) and to investigate whether there is a size difference between genders and ethnicities. METHODS: Retrospective study including children with normal sonographic findings and no evidence of liver or splenic disease clinically. Craniocaudal and anteroposterior dimensions are measured for the right and left lobe of the liver, and craniocaudal dimension for the spleen. Relationship of the liver and spleen dimensions with age, body length, body surface area, weight, and gender were investigated. Charts of normal values were established. Values were compared to studies involving other ethnicities and to one study carried out in 1983 involving the same ethnicity. RESULTS: Seven hundred thirty-six children (371 boys, 365 girls) aged 1 day - 18.4 years were included. From the second year of life, the craniocaudal dimension of the right lobe of the liver is 1-2 cm larger in the Central European population compared with non-Caucasian populations at a given age. Liver size of Central European children in 2020 is greater compared to a similar population almost 40 years ago. The craniocaudal dimension of the spleen of Central European, US-American and Turkish children is similar. The difference between genders is statistically significant for both the liver and the spleen, being larger in boys. CONCLUSION: Contemporary and ethnically appropriate reference charts for liver and spleen measurements should be used, especially for liver size. The effect of ethnicity is reduced if patient height rather than age is referenced.


Assuntos
Fígado , Baço , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Fígado/diagnóstico por imagem , Masculino , Tamanho do Órgão , Valores de Referência , Estudos Retrospectivos , Baço/diagnóstico por imagem , Ultrassonografia
17.
Insights Imaging ; 11(1): 114, 2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-33123830

RESUMO

OBJECTIVES: The objective of this study was to compare the radiology report turnaround time (RTAT) between decentralized/modality-based and centralized/subspecialized radiological reporting at a multi-center radiology enterprise. METHODS: RTAT values for MRI, CT, and conventional radiography were compared between decentralized/modality-based (04 September 2017-22 December 2017) and centralized/subspecialized radiology (03 September 2018-21 December 2018) reporting grouped into three subspecializations (body radiology, musculoskeletal radiology, and neuroradiology) at eleven sites of a multi-center radiology enterprise. For the objective of this investigation, hospitals were defined as major and minor hospitals. The Mann-Whitney U test served for statistical analyses. RESULTS: Change of reporting system from decentralized/modality-based to centralized/subspecialized radiology resulted overall in a significant decrease of the RTAT: from 82 to 77 min for the first signature (p < 0.001), and 119 to 107 min and 295 to 238 min for the second signature (p < 0.001). Subgroup analyses demonstrate a significant decrease of the RTAT for MRI reports (e.g., second signature RTAT, 1051 to 401 min; p < 0.001) and conventional radiographs (e. g., second signature RTAT, 278 to 171 min; p < 0.001). The RTAT at major hospitals decreased from 288 to 245 min (second signature; p < 0.001) while the corresponding RTAT of minor hospitals decreased more remarkably, from 300 to 198 min (p < 0.001). However, the results were heterogenous; in some analyses, the RTAT even increased. The effect size analyses represent small effects. CONCLUSIONS: Change of reporting system from decentralized/modality-based to centralized/subspecialized radiology was associated with a significant decreased RTAT. Specifically, the RTAT for MRI reports and conventional radiographs was significantly reduced. A pronounced RTAT decrease was observed at minor hospitals.

18.
Skeletal Radiol ; 49(11): 1819-1827, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32524168

RESUMO

OBJECTIVE: To determine diagnostic confidence and inter-observer/intra-observer agreement in differentiating epidural fibrosis from disc herniation and lumbar spinal stenosis parameters on magnetic resonance images (MRI) in postoperative lumbar spines with (Gad-MRI) and without (unenhanced MRI) intravenous gadolinium-based contrast agent. SUBJECTS AND METHODS: N = 124 lumbar spine MRI examinations of four groups were included: 1-6 months, 7-18 months, 19-36 months, more than 37 months between lumbar spine surgery and imaging. Two radiologists evaluated Gad-MRI and unenhanced MRI: diagnostic confidence was determined as confident or unconfident. Inter-observer and intra-observer agreement were assessed in differentiating epidural fibrosis from disc herniation and for lumbar spinal stenosis parameters on MRI. Fisher's exact test and Cohen's kappa served for statistics. RESULTS: Diagnostic confidence in differentiating epidural fibrosis from disc herniation was significantly higher on Gad-MR images compared with unenhanced MRI at 1-18 months for observer 1 and at 1-6 months postoperatively for observer 2 (p values: 0.01-0.025). Inter-observer agreement at 1-6 months postoperatively for identification of epidural fibrosis was higher on Gad-MRI (kappa values: 0.53 versus 0.24). Inter-observer and intra-observer agreement for identification of disc herniation and for assessment of lumbar spinal stenosis parameters revealed inconsistent data, without a trend for higher inter-observer or intra-observer agreement on Gad-MRI compared with unenhanced MRI (kappa values: 0.17-0.75). CONCLUSION: Gad-MR images compared with unenhanced MRI improved diagnostic confidence and agreement in differentiating epidural fibrosis from disc herniation for both observers in the first 6 months and for one observer in the first 18 months after lumbar spine surgery. After 18 months, Gad-MR images compared with unenhanced MRI did neither improve confidence nor agreement.


Assuntos
Deslocamento do Disco Intervertebral , Imageamento por Ressonância Magnética , Fibrose , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/patologia , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Vértebras Lombares/cirurgia , Variações Dependentes do Observador
19.
Acad Radiol ; 27(5): 644-650, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31471205

RESUMO

RATIONALE AND OBJECTIVES: To determine the value of chest CT with tin filtration applying a dose equivalent to chest x-ray for the assessment of the Haller index for evaluation of pectus excavatum. MATERIALS AND METHODS: Two hundred seventy-two patients from a prospective single center study were included and underwent a clinical standard dose chest CT (effective dose 1.8 ± 0.7 mSv) followed by a low-dose CT (0.13 ± 0.01 mSv) in the same session. Two blinded readers independently evaluated all data sets. Image quality for bony chest wall assessment was noted. Radiologists further assessed (a) transverse thoracic diameter, (b) anteroposterior thoracic diameter, and calculated (c) Haller index by dividing transverse diameter by anteroposterior diameter. The agreement of both readers in standard dose and low-dose CT was assessed using Lin's concordance correlation coefficient (pc). RESULTS: Subjective image quality was lower for low dose compared to standard dose CT images by both readers (p < 0.001). In total, 99% (n = 540) of low-dose CT scans were rated as diagnostic for bony chest wall assessment by both readers. There was a high agreement for assessment of transverse diameter, anteroposterior diameter and Haller index comparing both readers in standard dose and low-dose CT with pc values indicating substantial agreement (i.e., 0.95> and ≤0.99) in 12/18 (67%) and almost perfect agreement (i.e., >0.99) in 6/18 (33%). CONCLUSION: Our study suggests that low-dose CT with tin filtration applying a radiation dose equivalent to a plain chest X-ray is excellent for assessing the Haller index.


Assuntos
Tórax em Funil , Estanho , Tórax em Funil/diagnóstico por imagem , Humanos , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Raios X
20.
Eur J Radiol ; 121: 108720, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31711024

RESUMO

PURPOSE: To assess the interreader variability of submillisievert CT for lung cancer screening in radiologists with various experience levels. METHOD: Six radiologists with different degrees of clinical experience in radiology (range, 1-15 years), rated 100 submillisievert CT chest studies as either negative screening finding (no nodules, benign nodules, nodules <5 mm), indeterminate finding (nodules 5-10 mm), positive finding (nodules >10 mm). Each radiologist interpreted scans randomly ordered and reading time was recorded. Interobserver agreement was assessed with ak statistic. Reasons for differences in nodule classification were analysed on a case-by-case basis. Reading time was correlated with reader experience using Pearson correlation (r). RESULTS: The overall interobserver agreement between all readers was moderate (k = 0.454; p < 0.001). In 57 patients, all radiologists agreed on the differentiation of negative and indeterminate/positive finding. In 64 cases disagreement between readers led to different nodule classification. In 8 cases some readers rated the nodule as benign, whereas others scored the case as positive. Overall, disagreement in nodule classification was mostly due to failure in identification of target lesion (n = 40), different lesion measurement (n = 44) or different classification (n = 26). Mean overall reading time per scan was of 2 min 2 s (range: 7s-7 min 45 s) and correlated with reader-experience (r = -0.824). CONCLUSIONS: Our study showed substantial interobserver variability for the detection and classification of pulmonary nodules in submillisievert CT. This highlights the importance for careful standardisation of screening programs with the objective of harmonizing efforts of involved radiologists across different institutions by defining and assuring quality standards.


Assuntos
Competência Clínica/estatística & dados numéricos , Erros de Diagnóstico/estatística & dados numéricos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Radiologistas/estatística & dados numéricos , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...