1.
J Hepatol ; 75(4): 770-785, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33991635

RESUMO

BACKGROUND AND AIMS: Vibration-controlled transient elastography (VCTE), point shear wave elastography (pSWE), 2-dimensional shear wave elastography (2DSWE), magnetic resonance elastography (MRE), and magnetic resonance imaging (MRI) have been proposed as non-invasive tests for patients with non-alcoholic fatty liver disease (NAFLD). This study evaluated their diagnostic accuracy for liver fibrosis and non-alcoholic steatohepatitis (NASH). METHODS: PubMED/MEDLINE, EMBASE and the Cochrane Library were searched for studies examining the diagnostic accuracy of these index tests, against histology as the reference standard, in adult patients with NAFLD. Two authors independently screened and assessed methodological quality of studies and extracted data. Summary estimates of sensitivity, specificity and area under the curve (sAUC) were calculated for fibrosis stages and NASH, using a random effects bivariate logit-normal model. RESULTS: We included 82 studies (14,609 patients). Meta-analysis for diagnosing fibrosis stages was possible in 53 VCTE, 11 MRE, 12 pSWE and 4 2DSWE studies, and for diagnosing NASH in 4 MRE studies. sAUC for diagnosis of significant fibrosis were: 0.83 for VCTE, 0.91 for MRE, 0.86 for pSWE and 0.75 for 2DSWE. sAUC for diagnosis of advanced fibrosis were: 0.85 for VCTE, 0.92 for MRE, 0.89 for pSWE and 0.72 for 2DSWE. sAUC for diagnosis of cirrhosis were: 0.89 for VCTE, 0.90 for MRE, 0.90 for pSWE and 0.88 for 2DSWE. MRE had sAUC of 0.83 for diagnosis of NASH. Three (4%) studies reported intention-to-diagnose analyses and 15 (18%) studies reported diagnostic accuracy against pre-specified cut-offs. CONCLUSIONS: When elastography index tests are acquired successfully, they have acceptable diagnostic accuracy for advanced fibrosis and cirrhosis. The potential clinical impact of these index tests cannot be assessed fully as intention-to-diagnose analyses and validation of pre-specified thresholds are lacking. LAY SUMMARY: Non-invasive tests that measure liver stiffness or use magnetic resonance imaging (MRI) have been suggested as alternatives to liver biopsy for assessing the severity of liver scarring (fibrosis) and fatty inflammation (steatohepatitis) in patients with non-alcoholic fatty liver disease (NAFLD). In this study, we summarise the results of previously published studies on how accurately these non-invasive tests can diagnose liver fibrosis and inflammation, using liver biopsy as the reference. We found that some techniques that measure liver stiffness had a good performance for the diagnosis of severe liver scarring.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Imageamento por Ressonância Magnética/normas , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Área Sob a Curva , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Curva ROC
2.
Abdom Radiol (NY) ; 46(5): 1947-1957, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33247768

RESUMO

PURPOSE: Direct-acting antiviral therapies (DAAs) for treatment of chronic hepatitis C virus (HCV) have excellent rates of viral eradication, but their effect on regression of liver fibrosis is unclear. The primary aim was to use magnetic resonance imaging (MRI) and spectroscopy (MRS) to evaluate changes in liver fibrosis, liver fat and liver iron content (LIC) in patients with chronic HCV following treatment with DAAs. METHODS: In this prospective study, 15 patients with chronic HCV due to start treatment with DAAs and with transient elastography (TE) > 8 kPa were recruited consecutively. Patients underwent MRI and MRS at baseline (before treatment), and at 24 weeks and 48 weeks after the end of treatment (EoT) for the measurement of liver cT1 (fibroinflammation), liver fat and T2* (LIC). RESULTS: All patients achieved a sustained virological response. Liver cT1 showed significant decreases from baseline to 24 weeks post EoT (876 vs 806 ms, p = 0.002, n = 15), baseline to 48 weeks post EoT (876 vs 788 ms, p = 0.0002, n = 13) and 24 weeks post EoT to 48 weeks post EoT (806 vs 788 ms, p = 0.016, n = 13). Between baseline and 48 weeks EoT significant reduction in liver fat (5.17% vs 2.65%, p = 0.027) and an increase in reported LIC (0.913 vs 0.950 mg/g, p = 0.021) was observed. CONCLUSION: Liver cT1 decreases in patients with chronic HCV undergoing successful DAA treatment. The relatively fast reduction in cT1 suggests a reduction in inflammation rather than regression of fibrosis.


Assuntos
Antivirais , Hepatite C Crônica , Antivirais/uso terapêutico , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/tratamento farmacológico , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/tratamento farmacológico , Estudos Prospectivos , Resposta Viral Sustentada
3.
Liver Int ; 40(12): 3071-3082, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32730664

RESUMO

BACKGROUND & AIMS: Liver cT1 , liver T1 , transient elastography (TE) and blood-based biomarkers have independently been shown to predict clinical outcomes but have not been directly compared in a single cohort of patients. Our aim was to compare these tests' prognostic value in a cohort of patients with compensated chronic liver disease. METHODS: Patients with unselected compensated liver disease aetiologies had baseline assessments and were followed up for development of clinical outcomes, blinded to the imaging results. The prognostic value of non-invasive liver tests at prespecified thresholds was assessed for a combined clinical endpoint comprising ascites, variceal bleeding, hepatic encephalopathy, hepatocellular carcinoma, liver transplantation and mortality. RESULTS: One hundred and ninety-seven patients (61% male) with median age of 54 years were followed up for 693 patient-years (median (IQR) 43 (26-58) months). The main diagnoses were NAFLD (41%), viral hepatitis (VH, 25%) and alcohol-related liver disease (ArLD; 14%). During follow-up 14 new clinical events, and 11 deaths occurred. Clinical outcomes were predicted by liver cT1  > 825ms with HR 9.9 (95% CI: 1.29-76.4, P = .007), TE > 8kPa with HR 7.8 (95% CI: 0.97-62.3, P = .02) and FIB-4 > 1.45 with HR 4.09 (95% CI: 0.90-18.4, P = .05). In analysis taking into account technical failure and unreliability, liver cT1  > 825 ms could predict clinical outcomes (P = .03), but TE > 8kPa could not (P = .4). CONCLUSIONS: We provide further evidence that liver cT1 , TE and serum-based biomarkers can predict clinical outcomes, but when taking into account technical failure/unreliability, TE cut-offs perform worse than those of cT1 and blood biomarkers.


Assuntos
Técnicas de Imagem por Elasticidade , Varizes Esofágicas e Gástricas , Neoplasias Hepáticas , Imageamento por Ressonância Magnética Multiparamétrica , Biomarcadores , Varizes Esofágicas e Gástricas/etiologia , Varizes Esofágicas e Gástricas/patologia , Feminino , Hemorragia Gastrointestinal/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico
5.
PLoS One ; 14(8): e0221066, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31430314

RESUMO

BACKGROUND AND AIMS: Non-invasive assessment of portal hypertension is an area of unmet need. This proof of concept study aimed to evaluate the diagnostic accuracy of a multi-parametric magnetic resonance technique in the assessment of portal hypertension. Comparison to other non-invasive technologies was a secondary aim. METHODS: T1 and T2* maps through the liver and spleen were acquired prior to trans-jugular liver biopsy and hepatic vein pressure gradient (HVPG) measurement. T1 measurements reflect changes in tissue water content, but this relationship is confounded by the presence of iron, which in turn can be quantified accurately from T2* maps. Data were analysed using LiverMultiScan (Perspectum Diagnostics, Oxford, UK) which applies an algorithm to remove the confounding effect of iron, yielding the "iron corrected T1" (cT1). Sensitivity, specificity, diagnostic values and area under the curve were derived for spleen cT1, liver cT1, transient elastography, and serum fibrosis scores. HVPG was the reference standard. RESULTS: Nineteen patients (15 men) with median age 57 years were included. Liver disease aetiologies included non-alcoholic fatty liver disease (n = 9; 47%) and viral hepatitis (n = 4; 21%). There was strong correlation between spleen cT1 and HVPG (r = 0.69; p = 0.001). Other non-invasive biomarkers did not correlate with HVPG. Spleen cT1 had excellent diagnostic accuracy for portal hypertension (HVPG >5 mmHg) and clinically significant portal hypertension (HVPG ≥10 mmHg) with an area under the receiver operating characteristic curve of 0.92 for both. CONCLUSION: Spleen cT1 is a promising biomarker of portal pressure that outperforms other non-invasive scores and should be explored further.


Assuntos
Hipertensão Portal/diagnóstico , Cirrose Hepática/complicações , Imageamento por Ressonância Magnética/métodos , Pressão na Veia Porta/fisiologia , Baço/diagnóstico por imagem , Idoso , Biópsia , Técnicas de Imagem por Elasticidade , Feminino , Veias Hepáticas/fisiopatologia , Humanos , Hipertensão Portal/etiologia , Hipertensão Portal/fisiopatologia , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Estudos Prospectivos , Curva ROC
6.
NMR Biomed ; 32(2): e4030, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30462873

RESUMO

Modified Look-Locker inversion recovery (MOLLI) T1 mapping sequences can be useful in cardiac and liver tissue characterization, but determining underlying water T1 is confounded by iron, fat and frequency offsets. This article proposes an algorithm that provides an independent water MOLLI T1 (referred to as on-resonance water T1 ) that would have been measured if a subject had no fat and normal iron, and imaging had been done on resonance. Fifteen NiCl2 -doped agar phantoms with different peanut oil concentrations and 30 adults with various liver diseases, nineteen (63.3%) with liver steatosis, were scanned at 3 T using the shortened MOLLI (shMOLLI) T1 mapping, multiple-echo spoiled gradient-recalled echo and 1 H MR spectroscopy sequences. An algorithm based on Bloch equations was built in MATLAB, and water shMOLLI T1 values of both phantoms and human participants were determined. The quality of the algorithm's result was assessed by Pearson's correlation coefficient between shMOLLI T1 values and spectroscopically determined T1 values of the water, and by linear regression analysis. Correlation between shMOLLI and spectroscopy-based T1 values increased, from r = 0.910 (P < 0.001) to r = 0.998 (P < 0.001) in phantoms and from r = 0.493 (for iron-only correction; P = 0.005) to r = 0.771 (for iron, fat and off-resonance correction; P < 0.001) in patients. Linear regression analysis revealed that the determined water shMOLLI T1 values in patients were independent of fat and iron. It can be concluded that determination of on-resonance water (sh)MOLLI T1 independent of fat, iron and macroscopic field inhomogeneities was possible in phantoms and human subjects.


Assuntos
Adiposidade , Algoritmos , Ferro/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética , Água/metabolismo , Simulação por Computador , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
7.
Magn Reson Med ; 78(6): 2095-2105, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28244131

RESUMO

PURPOSE: Phosphorus (31 P) metabolites are emerging liver disease biomarkers. Of particular interest are phosphomonoester and phosphodiester (PDE) "peaks" that comprise multiple overlapping resonances in 31 P spectra. This study investigates the effect of improved spectral resolution at 7 Tesla (T) on quantifying hepatic metabolites in cirrhosis. METHODS: Five volunteers were scanned to determine metabolite T1 s. Ten volunteers and 11 patients with liver cirrhosis were scanned at 7T. Liver spectra were acquired in 28 min using a 16-channel 31 P array and 3D chemical shift imaging. Concentrations were calculated using γ-adenosine-triphosphate (γ-ATP) = 2.65 mmol/L wet tissue. RESULTS: T1 means ± standard deviations: phosphatidylcholine 1.05 ± 0.28 s, nicotinamide-adenine-dinucleotide (NAD+ ) 2.0 ± 1.0 s, uridine-diphosphoglucose (UDPG) 3.3 ± 1.4 s. Concentrations in healthy volunteers: α-ATP 2.74 ± 0.11 mmol/L wet tissue, inorganic phosphate 2.23 ± 0.20 mmol/L wet tissue, glycerophosphocholine 2.34 ± 0.46 mmol/L wet tissue, glycerophosphoethanolamine 1.50 ± 0.28 mmol/L wet tissue, phosphocholine 1.06 ± 0.16 mmol/L wet tissue, phosphoethanolamine 0.77 ± 0.14 mmol/L wet tissue, NAD+ 2.37 ± 0.14 mmol/L wet tissue, UDPG 2.00 ± 0.22 mmol/L wet tissue, phosphatidylcholine 1.38 ±â€Š0.31 mmol/L wet tissue. Inorganic phosphate and phosphatidylcholine concentrations were significantly lower in patients; glycerophosphoethanolamine concentrations were significantly higher (P < 0.05). CONCLUSION: We report human in vivo hepatic T1 s for phosphatidylcholine, NAD+ , and UDPG for the first time at 7T. Our protocol allows high signal-to-noise, repeatable measurement of metabolite concentrations in human liver. The splitting of PDE into its constituent peaks at 7T may allow more insight into changes in metabolism. Magn Reson Med 78:2095-2105, 2017. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Fósforo/química , Adulto , Ésteres/química , Feminino , Voluntários Saudáveis , Humanos , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Fosfatidilcolinas/química , Controle de Qualidade , Reprodutibilidade dos Testes , Uridina Difosfato Glucose/química , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA