Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Interv Cardiol ; 28(4): 374-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26224392

RESUMO

BACKGROUND AND OBJECTIVES: Percutaneous coronary intervention (PCI) in patients with lesions of large calibre coronary arteries (≥ 5 mm) and saphenous venous grafts (≥ 5 mm) can be challenging. There are no separate guidelines available to treat these vessels with PCI. Standard coronary stents of 4 mm diameter are used to treat these lesions conventionally but carry the risk of under deployment, distortion of stent architecture and future stent thrombosis even if they are subsequently expanded beyond 5 mm. METHODS AND RESULTS: Biliary stents (Herculink Elite™) provide a better alternative to standard coronary stents in these patients. These stents are of larger diameter (5-7 mm) and can be safely delivered over a 6 French sheath. In our case series, we demonstrate the use of intravascular ultrasound examination to confirm that biliary stents provide improved stent strut apposition within the coronary artery associated with extremely low repeat revascularisation rates. CONCLUSION: Our paper highlights that PCI of lesions in patients with large calibre coronary arteries can successfully be achieved using biliary stents.


Assuntos
Estenose Coronária/terapia , Implantação de Prótese , Stents , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Desenho de Prótese , Estudos Retrospectivos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante , Ultrassonografia de Intervenção
2.
EuroIntervention ; 9(2): 243-50, 2013 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-23454891

RESUMO

AIMS: To establish success and complication rates of excimer laser coronary atherectomy (ELCA) in a contemporary series of patients with balloon failure during percutaneous coronary intervention (PCI) of both chronic total occlusions (CTO) and lesions with distal TIMI 3 flow. METHODS AND RESULTS: We identified 58 cases of balloon failure treated with ELCA±rotational atherectomy (RA) over four years, representing 0.84% of all PCI performed in our centre during this period. Balloon failures were classified according to: (i) mechanism of balloon failure; and (ii) whether this occurred in the context of treating a CTO. ELCA was performed following balloon failure using the CVX-300 Excimer Laser System and a 0.9 mm catheter with saline flush. For the entire cohort, procedure success was achieved in 91% (with ELCA successful: alone in 76.1%, after RA failure in 6.8% and in combination with RA for 8.6%). Only in one case did RA succeed where ELCA had failed. There were four procedure-related complications, including transient no-reflow, side branch occlusion and two coronary perforations, of which one was directly attributable to ELCA and led to subsequent mortality. CONCLUSIONS: ELCA provides safe and effective adjunctive therapy in contemporary PCI to treat lesions associated with balloon failure due to an inability either to cross the lesion or to expand a balloon sufficiently to permit stenting. ELCA was successful in the majority of these selected cases when used independently with further effectiveness achieved when combined with RA or after RA failure.


Assuntos
Aterectomia Coronária/instrumentação , Doença da Artéria Coronariana/terapia , Oclusão Coronária/terapia , Lasers de Excimer/uso terapêutico , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Aterectomia Coronária/efeitos adversos , Aterectomia Coronária/métodos , Cateteres Cardíacos , Doença Crônica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Oclusão Coronária/diagnóstico , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...