Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chim Acta ; 413(11-12): 955-9, 2012 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-22330876

RESUMO

BACKGROUND: Point-of-care devices for performing a prothrombin time/international normalized ratio (PT/INR) using capillary blood samples are being increasingly used to monitor patients receiving anticoagulation therapy. However, the performance of some devices has been shown to be suboptimal and there are only limited published data comparing specific devices to various central laboratory coagulation analyzers. We report an evaluation of the iSTAT PT/INR with a comparison to the Tcoag MDA II analyzer. METHODS: We obtained simultaneous capillary/venous samples on 20 healthy volunteers for a normal range study and on 50 anticoagulated patients for a clinical evaluation. Testing was performed by phlebotomists. We also obtained 68 near simultaneous capillary/venous test results for assessment of performance by non-laboratory personnel. The criteria for determining clinical equivalence of the iSTAT to the MDA II were (1) same clinical category (subtherapeutic INR<2, therapeutic INR 2-3, and supratherapeutic INR>3) or (2) paired values within ≤ 0.4 INR. RESULTS: Forty nine of 50 patient sample pairs collected by phlebotomists showed acceptable clinical agreement. Sixty one (61) of 68 patient sample pairs collected by nurses showed acceptable agreement. In all discordant cases the differences were minor and would have resulted in either no or minimal change in therapy. CONCLUSIONS: The iSTAT PT/INR compares well to the MDA II when performed by phlebotomists or nurses.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Tempo de Protrombina/instrumentação , Tempo de Protrombina/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Capilares , Equipamentos e Provisões Hospitalares , Feminino , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Valores de Referência , Veias
2.
Analyst ; 134(6): 1092-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19475134

RESUMO

A total of 1,429 serum samples from 389 consecutive patients with acute chest pain were analyzed with the goal to aid the rapid diagnosis of acute myocardial infarction. To the best of our knowledge this is the largest and most comprehensive study on mid-infrared spectroscopy in cardiology. We were able to identify those signatures in the mid-infrared spectra of the samples, which were specific to either acute myocardial infarction or chest pain of other origin (angina pectoris, oesophagitis, etc). These characteristic spectral differences were used to distinguish between the cause of the donor's acute chest pain using robust linear discriminant analysis. A sensitivity of 88.5% and a specificity of 85.1% were achieved in a blind validation. The area under the receiver operating characteristics curve amounts to 0.921, which is comparable to the performance of routine cardiac laboratory markers within the same study population. The biochemical interpretation of the spectral signatures points towards an important role of carbohydrates and potentially glycation. Our studies indicate that the "Diagnostic Pattern Recognition (DPR)" method presented here has the potential to aid the diagnostic procedure as early as within the first 6 hours after the onset of chest pain.


Assuntos
Dor no Peito/diagnóstico , Espectrofotometria Infravermelho/métodos , Triagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Padrões de Referência , Sensibilidade e Especificidade , Espectrofotometria Infravermelho/normas , Fatores de Tempo , Triagem/normas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...