Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 40(5): 1160-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22189492

RESUMO

Since lung diseases adversely affect airflow during breathing, they must also alter normal lung motion, which can be exploited to detect these diseases. However, standard imaging techniques such as CT and MRI imaging during breath-holds provide little or no information on lung motion and cannot detect diseases that cause subtle changes in lung structure. Phase-contrast X-ray imaging provides images of high contrast and spatial resolution with temporal resolutions that allow multiple images to be acquired throughout the respiratory cycle. Using X-ray phase-contrast imaging, coupled with velocimetry, we have measured lung tissue movement and determined velocity fields that define speed and direction of regional lung motion throughout a breath in normal Balb/c nude male mice and mice exposed to bleomycin. Regional maps of lung tissue motion reveal both the heterogeneity of normal lung motion, as well as abnormal motion induced by bleomycin treatment. Analysed histologically, bleomycin treatment caused pathological changes in lung structure that were heterogenous, occupying less than 12% of the lung at 6 days after treatment. Moreover, plethysmography failed to detect significant changes in compliance at either 36 h or 6 days after treatment. Detailed analysis of the vector fields demonstrated major differences (p < 0.001) in regional lung motion between control and bleomycin-treated mice at both 36 h and 6 days after treatment. The results of this study demonstrate that X-ray phase-contrast imaging, coupled with velocimetry, can detect early stage, subtle and non-uniform lung disease.


Assuntos
Pneumopatias/diagnóstico por imagem , Pneumopatias/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Mecânica Respiratória , Tomografia Computadorizada por Raios X/métodos , Animais , Antibióticos Antineoplásicos/efeitos adversos , Antibióticos Antineoplásicos/farmacologia , Bleomicina/efeitos adversos , Bleomicina/farmacologia , Pneumopatias/induzido quimicamente , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Fatores de Tempo
2.
Eur J Radiol ; 68(3 Suppl): S49-53, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18599236

RESUMO

Analyser-based phase contrast X-ray imaging can provide high-contrast images of biological tissues with exquisite sensitivity to the boundaries between tissues. The phase and absorption information can be extracted by processing multiple images acquired at different analyser orientations. Recording both the transmitted and diffracted beams from a thin Laue analyser crystal can make phase retrieval possible for dynamic systems by allowing full field imaging. This technique was used to image the thorax of a mechanically ventilated newborn rabbit pup using a 25 keV beam from the SPring-8 synchrotron radiation facility. The diffracted image was produced from the (111) planes of a 50 mm x 40 mm, 100 microm thick Si analyser crystal in the Laue geometry. The beam and analyser were large enough to image the entire chest, making it possible to observe changes in anatomy with high contrast and spatial resolution.


Assuntos
Imageamento Tridimensional/veterinária , Radiografia Torácica/veterinária , Refratometria/veterinária , Tomografia por Raios X/veterinária , Algoritmos , Animais , Animais Recém-Nascidos , Cães , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Refratometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia por Raios X/métodos
3.
Phys Med Biol ; 50(15): 3599-611, 2005 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-16030385

RESUMO

We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/métodos , Lesões Pré-Cancerosas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias da Mama/complicações , Neoplasias da Mama/patologia , Calcinose/complicações , Calcinose/patologia , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...