Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(7): 1795-800, 2012 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-23016327

RESUMO

The structure features and spatial characteristics of the two kinds of micro-machined membrane deformable mirrors, OKO 37-element and BMC 140-element, which work in the NIR based human eye aberration correction system, are compared and analyzed. At same time, the principal component analysis was carried out for the influence function of the mirror, the voltage control model was established and the optimal control mode of deformable mirror can be determined by adjusting the control parameter d. Finally, the simulation experiments for fitting aberration of unit Zernike mode and human eye aberration of Thibos model were carried out. The experiment results show that the capability for fitting the each Zernike mode of BMC 140-element mirror is twice more than the OKO 37-element mirror at least. When correcting the Thibos model human eye aberration whose average RMS error is 0.638 lambda (lambda=0.785 microm), the residual RMS error of BMC mirror is 0.063 lambda which achieves the diffraction limit (lambda/14) of the optical system, but the correction capability of OKO mirror is far less than BMC mirror due to the large cross-linked value between actuators, small density distribution of actuators and some other influencing factors, and the residual wave-front RMS error is 0.168 lambda. The methodology can also be used for other types of deformable mirror performance evaluation.


Assuntos
Modelos Teóricos , Dispositivos Ópticos , Transtornos da Visão , Humanos , Análise de Componente Principal
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(8): 2232-5, 2010 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-20939346

RESUMO

Zernike mode reconstruction model of human eye wavefront aberrations based on Hartmann-Shack sensor is introduced. Three algorithms, including Gram-Schmidt orthogonal transformation, Householder transformation and singular value decomposition, are deduced and compared with each other. Through simulation by the experimental data, the results suggest that the accuracy of the three methods is equivalent and singular value decomposition is the relatively ideal algorithm of wavefront aberrations of human eyes.


Assuntos
Algoritmos , Olho , Modelos Teóricos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...