Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38768264

RESUMO

Freestanding single-crystalline SrTiO3 membranes, as high-κ dielectrics, hold significant promise as the gate dielectric in two-dimensional (2D) flexible electronics. Nevertheless, the mechanical properties of the SrTiO3 membranes, such as elasticity, remain a critical piece of the puzzle to adequately address the viability of their applications in flexible devices. Here, we report statistical analysis on plane-strain effective Young's modulus of large-area SrTiO3 membranes (5 × 5 mm2) over a series of thicknesses (from 6.5 to 32.2 nm), taking advantage of a highly efficient buckling-based method, which reveals its evident thickness-dependent behavior ranging from 46.01 to 227.17 GPa. Based on microscopic and theoretical results, we elucidate these thickness-dependent behaviors and statistical data deviation with a bilayer model, which consists of a surface layer and a bulk-like layer. The analytical results show that the ∼3.1 nm surface layer has a significant elastic softening compared to the bulk-like layer, while the extracted modulus of the bulk-like layer shows a variation of ∼40 GPa. This variation is considered as a combined contribution from oxygen deficiency presenting in SrTiO3 membranes, and the alignment between applied strain and the crystal orientation. Upon comparison of the extracted elastic properties and electrostatic control capability to those of other typical gate dielectrics, the superior performance of single-crystalline SrTiO3 membranes has been revealed in the context of flexible gate dielectrics, indicating the significant potential of their application in high-performance flexible 2D electronics.

2.
J Hazard Mater ; 471: 134317, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38636229

RESUMO

Although previous studies have shown increased health risks of particulate matters, few have evaluated the long-term health impacts of ultrafine particles (UFPs or PM0.1, ≤ 0.1 µm in diameter). This study assessed the association between long-term exposure to UFPs and mortality in New York State (NYS), including total non-accidental and cause-specific mortalities, sociodemographic disparities and seasonal trends. Collecting data from a comprehensive chemical transport model and NYS Vital Records, we used the interquartile range (IQR) and high-level UFPs (≥75 % percentile) as indicators to link with mortalities. Our modified difference-in-difference model controlled for other pollutants, meteorological factors, spatial and temporal confounders. The findings indicate that long-term UFPs exposure significantly increases the risk of non-accidental mortality (RR=1.10, 95 % CI: 1.05, 1.17), cardiovascular mortality (RR=1.11, 95 % CI: 1.05, 1.18) particularly for cerebrovascular (RR=1.21, 95 % CI: 1.10, 1.35) and pulmonary heart diseases (RR=1.33, 95 % CI: 1.13, 1.57), and respiratory mortality (borderline significance, RR=1.09, 95 % CI: 1.00, 1.18). Hispanics (RR=1.13, 95 % CI: 1.00, 1.29) and non-Hispanic Blacks (RR=1.40, 95 % CI: 1.16, 1.68) experienced significantly higher mortality risk after exposure to UFPs, compared to non-Hispanic Whites. Children under five, older adults, non-NYC residents, and winter seasons are more susceptible to UFPs' effects.


Assuntos
Poluentes Atmosféricos , Material Particulado , New York/epidemiologia , Humanos , Material Particulado/toxicidade , Pessoa de Meia-Idade , Idoso , Adulto , Poluentes Atmosféricos/toxicidade , Feminino , Masculino , Criança , Adolescente , Pré-Escolar , Adulto Jovem , Doenças Cardiovasculares/mortalidade , Exposição Ambiental/efeitos adversos , Mortalidade/tendências , Lactente , Fatores Socioeconômicos , Estações do Ano , Fatores Sociodemográficos , Tamanho da Partícula , Recém-Nascido
3.
Reg Anesth Pain Med ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490687

RESUMO

INTRODUCTION: A novel, spinal cord stimulation (SCS) system with a physiologic closed-loop (CL) feedback mechanism controlled by evoked compound action potentials (ECAPs) enables the optimization of physiologic neural dose and the accuracy of the stimulation, not possible with any other commercially available SCS systems. The report of objective spinal cord measurements is essential to increase the transparency and reproducibility of SCS therapy. Here, we report a cohort of the EVOKE double-blind randomized controlled trial treated with CL-SCS for 36 months to evaluate the ECAP dose and accuracy that sustained the durability of clinical improvements. METHODS: 41 patients randomized to CL-SCS remained in their treatment allocation and were followed up through 36 months. Objective neurophysiological data, including measures of spinal cord activation, were analyzed. Pain relief was assessed by determining the proportion of patients with ≥50% and ≥80% reduction in overall back and leg pain. RESULTS: The performance of the feedback loop resulted in high-dose accuracy by keeping the elicited ECAP within 4µV of the target ECAP set on the system across all timepoints. Percent time stimulating above the ECAP threshold was >98%, and the ECAP dose was ≥19.3µV. Most patients obtained ≥50% reduction (83%) and ≥80% reduction (59%) in overall back and leg pain with a sustained response observed in the rates between 3-month and 36-month follow-up (p=0.083 and p=0.405, respectively). CONCLUSION: The results suggest that a physiological adherence to supra-ECAP threshold therapy that generates pain inhibition provided by ECAP-controlled CL-SCS leads to durable improvements in pain intensity with no evidence of loss of therapeutic effect through 36-month follow-up.

4.
J Pain Res ; 17: 1209-1222, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38524688

RESUMO

Introduction: Research suggests that sacroiliac joint (SIJ) dysfunction is responsible for 15% to 30% of reported low back pain cases. Recently, there has been an increasing interest in SIJ fusion using minimally invasive surgery (MIS) due to safety. Initially, devices designed for MIS were intended for lateral approaches. A minimally invasive sacroiliac fusion implant for use with a posterior approach has been developed and is regulated for clinical use under the regulatory framework required for human cells, tissues, or cellular or tissue-based products (HCT/Ps). Methods: A multi-center, prospective, single-arm study was launched after initial studies provided preliminary data to support safety, efficacy, and durability of this minimally invasive sacroiliac posterior fusion LinQ allograft implant (NCT04423120). Preliminary results were reported previously. Final results for the full participant cohort are presented here. Results: One-hundred and fifty-nine (159) participants were enrolled across 16 investigational sites in the US between January 2020 and March 2022. One-hundred and twenty-two (122) participants were implanted. At the 1-month follow-up, 82 participants satisfied all criteria for the composite responder endpoint, representing 73.2% of the study cohort. These results stayed consistent across the remaining study timepoints with 66.0%, 74.4%, and 73.5% of participants classified as responders at the 3-, 6- and 12-month follow-up visits, respectively. VAS scores were significantly reduced (p < 0.0001) and ODI scores were significantly improved (p < 0.0001). All domains of the PROMIS-29 were also significantly improved (all p's <0.0001). Only one procedure-related serious AE was reported in the study. Conclusion: These results suggest that the posterior approach LinQ Implant System is a safe and effective treatment for sacroiliac joint dysfunction at 12 months, with results that are favorable compared to outcomes reported for an FDA-cleared lateral approach.

6.
Nanotechnology ; 35(24)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38387088

RESUMO

The recombination of photoexcited electron-hole pairs greatly limits the degradation performance of photocatalysts. Ultrasonic cavitation and internal electric field induced by the piezoelectric effect are helpful for the separation of electron-hole pairs and degradation efficiency. The activated foam carbon (AFC) owing to its high surface area is often used as the substrate to grow catalysts to provide more reactive active sites. In this work, CuO@BaTiO3(CuO@BTO) heterostructure is prepared by hydrothermal method on the surface of AFC to investigate the ultrasonic piezoelectric catalysis effect. X-ray diffraction (XRD), Raman spectroscopy, energy dispersive x-ray spectroscopy (EDS) and scanning electron microscopy (SEM) were used to analyze the structure and morphology of CuO-BTO/AFC composite. It is found that the CuO-BTO/AFC composite exhibits excellent piezo-catalytic performance for the degradation of organics promoted by ultrasonic vibration. The CuO-BTO/AFC composite can decompose methyl orange and methylene blue with degradation efficiency as high as 93.9% and 97.6% within 25 min, respectively. The mechanism of piezoelectricity enhanced ultrasound supported catalysis effect of system CuO-BTO/AFC is discussed. The formed heterojunction structure between BTO and CuO promotes the separation of positive and negative charges caused by the piezoelectric effect.

7.
J Pain Res ; 17: 691-736, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38405684

RESUMO

Aim: Visceral pain, characterized by pain that is diffuse and challenging to localize, occurs frequently and is difficult to treat. In cases where the pain becomes intractable despite optimal medical management, it can affect patients' Quality of Life (QoL). Spinal Cord Stimulation (SCS) has emerged as a potential solution for intractable visceral pain. Purpose: In this narrative review, we collected all evidence regarding the efficacy of SCS for visceral pain across various underlying conditions. Methods: A comprehensive literature search was conducted in PubMed, Embase, and Web of Science in which articles published from October 1st, 1963 up to March 7th, 2023 were identified. Results: Seventy articles were included in this review of which most were retrospective cohort studies, case series and case reports. The studies, often with a small number of participants, reported on SCS for chronic pancreatitis, anorectal pain and bowel disorders, gynaecological diagnoses, visceral pelvic pain, urological disorders and finally general visceral pain. They found positive effects on pain and/or symptom relief, opioid consumption, anxiety and depression and QoL. Complications occurred frequently but were often minor and reversible. Conclusion: Better screening and selection criteria need to be established to optimally evaluate eligible patients who might benefit from SCS. A positive outcome of a sympathetic nerve block appears to be a potential indicator of SCS effectiveness. Additionally, women receiving SCS for endometriosis had a better outcome compared to other indications. Finally, SCS could also relief functional symptoms such as voiding problems and gastroparesis. Complications could often be resolved with revision surgery. Since SCS is expensive and not always covered by standard health insurance, the incorporation of cost-analyses is recommended. In order to establish a comprehensive treatment plan, including selection criteria for SCS, rigorous prospective, possibly randomized and controlled studies that are diagnosis-oriented, with substantial follow-up and adequate sample sizes, are needed.

8.
J Phys Chem Lett ; 15(9): 2359-2368, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38391127

RESUMO

Lead-free perovskites are considered to be candidates for next-generation photodetectors, because of their excellent charge carrier transport properties and low toxicity. However, their application in integrated circuits is hindered by their inadequate performance and size restrictions. To aim at the development of lead-free perovskite-integrated optoelectronic devices, a CsAg2I3/silicon (CAI/Si) heterojunction is presented in this work by using a spatial confinement growth method, where the in-plane growth of CAI microbelts with high-quality single-crystal characteristics is primarily dependent on the concentration of surrounding precursor solution. The fabricated photodetectors based on the CAI/Si heterojunctions exhibit a broad-spectrum detection capability in the ultraviolet-visible-near-infrared (UV-vis-NIR) range. In addition, the photodetectors show good photoelectric detection performance, including a maximum responsivity of 48.5 mA/W and detectivity of 1.13 × 1011 Jones, respectively. Besides, the photodetectors have a rapid response of 6.5/224 µs and good air stability for over 2 months. This work contributes a new idea to design next-generation optoelectronic devices with high integration density.

9.
Nat Nanotechnol ; 19(5): 588-603, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38172431

RESUMO

Owing to their excellent discharged energy density over a broad temperature range, polymer nanocomposites offer immense potential as dielectric materials in advanced electrical and electronic systems, such as intelligent electric vehicles, smart grids and renewable energy generation. In recent years, various nanoscale approaches have been developed to induce appreciable enhancement in discharged energy density. In this Review, we discuss the state-of-the-art polymer nanocomposites with improved energy density from three key aspects: dipole activity, breakdown resistance and heat tolerance. We also describe the physical properties of polymer nanocomposite interfaces, showing how the electrical, mechanical and thermal characteristics impact energy storage performances and how they are interrelated. Further, we discuss multi-level nanotechnologies including monomer design, crosslinking, polymer blending, nanofiller incorporation and multilayer fabrication. We conclude by presenting the current challenges and future opportunities in this field.

10.
Reg Anesth Pain Med ; 49(3): 184-191, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-37407279

RESUMO

INTRODUCTION: Low back pain is the leading cause of disability worldwide, with sacroiliac joint pain comprising up to 30% of cases of axial lower back pain. Conservative therapies provide only modest relief. Although placebo-controlled trials show efficacy for sacral lateral branch cooled radiofrequency ablation, there are no comparative effectiveness studies. METHODS: In this randomized, multicenter comparative effectiveness study, 210 patients with clinically suspected sacroiliac joint pain who obtained short-term benefit from diagnostic sacroiliac joint injections and prognostic lateral branch blocks were randomly assigned to receive cooled radiofrequency ablation of the L5 dorsal ramus and S1-S3 lateral branches or standard medical management consisting of pharmacotherapy, injections and integrative therapies. The primary outcome measure was mean reduction in low back pain score on a 0-10 Numeric Rating Scale at 3 months. Secondary outcomes included measures of quality of life and function. RESULTS: 3 months post-treatment, the mean Numeric Rating Scale pain score for the cooled radiofrequency ablation group was 3.8±2.4 (mean reduction 2.5±2.5) compared with 5.9±1.7 (mean reduction 0.4±1.7) in the standard medical management group (p<0.0001). 52.3% of subjects in the cooled radiofrequency ablation group experienced >2 points or 30% pain relief and were deemed responders versus 4.3% of standard medical management patients (p<0.0001). Comparable improvements favoring cooled radiofrequency ablation were noted in Oswestry Disability Index score (mean 29.7±15.2 vs 41.5+13.6; p<0.0001) and quality of life (mean EuroQoL-5 score 0.68±0.22 vs 0.47±0.29; p<0.0001). CONCLUSIONS: In patients with sacroiliac joint pain, cooled radiofrequency ablation provided statistically superior improvements across the spectrum of patient outcomes compared with standard medical management. TRIAL REGISTRATION NUMBER: NCT03601949.


Assuntos
Dor Crônica , Dor Lombar , Ablação por Radiofrequência , Humanos , Artralgia/diagnóstico , Artralgia/cirurgia , Dor Lombar/diagnóstico , Dor Lombar/cirurgia , Qualidade de Vida , Articulação Sacroilíaca/cirurgia , Resultado do Tratamento
11.
Reg Anesth Pain Med ; 49(4): 233-240, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37491149

RESUMO

INTRODUCTION: Chronic pain patients may experience impairments in multiple health-related domains. The design and interpretation of clinical trials of chronic pain interventions, however, remains primarily focused on treatment effects on pain intensity. This study investigates a novel, multidimensional holistic treatment response to evoked compound action potential-controlled closed-loop versus open-loop spinal cord stimulation as well as the degree of neural activation that produced that treatment response. METHODS: Outcome data for pain intensity, physical function, health-related quality of life, sleep quality and emotional function were derived from individual patient level data from the EVOKE multicenter, participant, investigator, and outcome assessor-blinded, parallel-arm randomized controlled trial with 24 month follow-up. Evaluation of holistic treatment response considered whether the baseline score was worse than normative values and whether minimal clinical important differences were reached in each of the domains that were impaired at baseline. A cumulative responder score was calculated to reflect the total minimal clinical important differences accumulated across all domains. Objective neurophysiological data, including spinal cord activation were measured. RESULTS: Patients were randomized to closed-loop (n=67) or open-loop (n=67). A greater proportion of patients with closed-loop spinal cord stimulation (49.3% vs 26.9%) were holistic responders at 24-month follow-up, with at least one minimal clinical important difference in all impaired domains (absolute risk difference: 22.4%, 95% CI 6.4% to 38.4%, p=0.012). The cumulative responder score was significantly greater for closed-loop patients at all time points and resulted in the achievement of more than three additional minimal clinical important differences at 24-month follow-up (mean difference 3.4, 95% CI 1.3 to 5.5, p=0.002). Neural activation was three times more accurate in closed-loop spinal cord stimulation (p<0.001 at all time points). CONCLUSION: The results of this study suggest that closed-loop spinal cord stimulation can provide sustained clinically meaningful improvements in multiple domains and provide holistic improvement in the long-term for patients with chronic refractory pain. TRIAL REGISTRATION NUMBER: NCT02924129.


Assuntos
Dor Crônica , Estimulação da Medula Espinal , Humanos , Dor Crônica/diagnóstico , Dor Crônica/terapia , Estimulação da Medula Espinal/métodos , Qualidade de Vida , Método Duplo-Cego , Medição da Dor/métodos , Resultado do Tratamento , Medula Espinal
12.
Pain Physician ; 26(7): 575-584, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37976486

RESUMO

BACKGROUND: Chronic, intractable, neuropathic pain is readily treatable with spinal cord stimulation (SCS). Technological advancements, including device miniaturization, are advancing the field of neuromodulation. OBJECTIVES: We report here the results of an SCS clinical trial to treat chronic, low back and leg pain, with a micro-implantable pulse generator (micro-IPG). STUDY DESIGN: This was a single-arm, prospective, multicenter, postmarket, observational study. SETTING: Patients were recruited from 15 US-based comprehensive pain centers. METHODS: This open-label clinical trial was designed to evaluate the performance of the Nalu™ Neurostimulation System (Nalu Medical, Inc., Carlsbad, CA) in the treatment of low back and leg pain. Patients, who provided informed consent and were successfully screened for study entry, were implanted with temporary trial leads. Patients went on to receive a permanent implant of the leads and micro-IPG if they demonstrated a >= 50% reduction in pain during the temporary trial period. Patient-reported outcomes (PROs), such as pain scores, functional disability, mood, patient impression of change, comfort, therapy use profile, and device ease of use, were captured. RESULTS: At baseline, the average pain Visual Analog Scale (VAS) score was 72.1 ± 17.9 in the leg and 78.0 ± 15.4 in the low back. At 90 days following permanent implant (end of study), pain scores improved by 76% (VAS 18.5 ± 18.8) in the leg and 75% (VAS 19.7 ± 20.8) in the low back. Eighty-six percent  of both leg pain and low back pain patients demonstrated a >= 50% reduction in pain at 90 days following implant. The comfort of the external wearable (Therapy Disc and Adhesive Clip) was rated 1.16 ± 1.53, on average, at 90 days on an 11-point rating scale (0 = very comfortable, 10 = very uncomfortable). All PROs demonstrated statistically significant symptomatic improvement at 90 days following implant of the micro-IPG. LIMITATIONS:   Limitations of this study include the lack of long-term results (beyond 90 days) and a relatively small sample size of 35 patients who were part of the analysis; additionally, there was no control arm or randomization as this was a single-arm study, without a comparator, designed to document the efficacy and safety of the device. Therefore, no direct comparisons to other SCS systems were possible. CONCLUSIONS: This clinical study demonstrated profound leg and low back pain relief in terms of overall pain reduction, as well as the proportion of therapy responders. The study patients reported the wearable aspects of the system to be very comfortable.


Assuntos
Dor Crônica , Dor Lombar , Neuralgia , Dor Intratável , Estimulação da Medula Espinal , Humanos , Dor Lombar/terapia , Estudos Prospectivos , Resultado do Tratamento , Medição da Dor/métodos , Dor Crônica/terapia , Estimulação da Medula Espinal/métodos , Neuralgia/terapia , Medula Espinal
13.
J Cheminform ; 15(1): 104, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37936244

RESUMO

BACKGROUND: Identifying the molecular formula and fragmentation reactions of an unknown compound from its mass spectrum is crucial in areas such as natural product chemistry and metabolomics. We propose a method for identifying the correct candidate formula of an unidentified natural product from its mass spectrum. The method involves scoring the plausibility of parent candidate formulae based on a parent subformula graph (PSG), and two possible metrics relating to the number of edges in the PSG. This method is applicable to both electron-impact mass spectrometry (EI-MS) and tandem mass spectrometry (MS/MS) data. Additionally, this work introduces the two-dimensional fragmentation plot (2DFP) for visualizing PSGs. RESULTS: Our results suggest that incorporating information regarding the edges of the PSG results in enhanced performance in correctly identifying parent formulae, in comparison to the more well-accepted "MS/MS score", on the 2016 Computational Assessment of Small Molecule Identification (CASMI 2016) data set (76.3 vs 58.9% correct formula identification) and the Research Centre for Toxic Compounds in the Environment (RECETOX) data set (66.2% vs 59.4% correct formula identification). In the extension of our method to identify the correct candidate formula from complex EI-MS data of semiochemicals, our method again performed better (correct formula appearing in the top 4 candidates in 20/23 vs 7/23 cases) than the MS/MS score, and enables the rapid identification of both the correct parent ion mass and the correct parent formula with minimal expert intervention. CONCLUSION: Our method reliably identifies the correct parent formula even when the mass information is ambiguous. Furthermore, should parent formula identification be successful, the majority of associated fragment formulae can also be correctly identified. Our method can also identify the parent ion and its associated fragments in EI-MS spectra where the identity of the parent ion is unclear due to low quantities and overlapping compounds. Finally, our method does not inherently require empirical fitting of parameters or statistical learning, meaning it is easy to implement and extend upon. SCIENTIFIC CONTRIBUTION: Developed, implemented and tested new metrics for assessing plausibility of candidate molecular formulae obtained from HR-MS data.

14.
Neurooncol Adv ; 5(1): vdad095, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37781087

RESUMO

Background: Medulloblastoma is the most common malignant pediatric brain tumor, and leptomeningeal dissemination (LMD) of medulloblastoma both portends a poorer prognosis at diagnosis and is incurable at recurrence. The biological mechanisms underlying LMD are unclear. The Abelson (ABL) tyrosine kinase family members, ABL1 and ABL2, have been implicated in cancer cell migration, invasion, adhesion, metastasis, and chemotherapy resistance, and are upstream mediators of the oncogene c-MYC in fibroblasts and lung cancer cells. However, their role in medulloblastoma has not yet been explored. The purpose of this work was to elucidate the role of ABL1/2 in medulloblastoma LMD. Methods: ABL1 and ABL2 mRNA expression of patient specimens was analyzed. shRNA knockdowns of ABL1/2 and pharmacologic inhibition of ABL1/2 were used for in vitro and in vivo analyses of medulloblastoma LMD. RNA sequencing of ABL1/2 genetic knockdown versus scrambled control medulloblastoma was completed. Results: ABL1/2 mRNA is highly expressed in human medulloblastoma and pharmacologic inhibition of ABL kinases resulted in cytotoxicity. Knockdown of ABL1/2 resulted in decreased adhesion of medulloblastoma cells to the extracellular matrix protein, vitronectin (P = .0013), and significantly decreased tumor burden in a mouse model of medulloblastoma LMD with improved overall survival (P = .0044). Furthermore, both pharmacologic inhibition of ABL1/2 and ABL1/2 knockdown resulted in decreased expression of c-MYC, identifying a putative signaling pathway, and genes/pathways related to oncogenesis and neurodevelopment were differentially expressed between ABL1/2 knockdown and control medulloblastoma cells. Conclusions: ABL1 and ABL2 have potential roles in medulloblastoma LMD upstream of c-MYC expression.

15.
Neuromodulation ; 26(7): 1295-1308, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632517

RESUMO

OBJECTIVE: Emerging spinal cord stimulation (SCS) remote monitoring and programming technologies provide a unique opportunity to address challenges of in-person visits and improve patient care, although clinical guidance on implementation is needed. The goal of this document is to establish best clinical practices for integration of remote device management into the care of patients with SCS, including remote monitoring and remote programming. MATERIALS AND METHODS: A panel of experts in SCS met in July 2022, and additional experts contributed to the development of recommendations after the meeting via survey responses and correspondence. RESULTS: Major goals of remote SCS device management were identified, including prompt identification and resolution of SCS-related issues. The panel identified metrics for remote monitoring and classified them into three categories: device-related (eg, stimulation usage); measurable physiologic or disease-related (eg, patient physical activity or pedometry); and patient-reported (eg, sleep quality and pain intensity). Recommendations were made for frequency of reviewing remote monitoring metrics, although providers should tailor follow-up to individual patient needs. Such periodic reviews of remote monitoring metrics would occur separately from automatic monitoring system notifications (if key metrics fall outside an acceptable range). The guidelines were developed in consideration of reimbursement processes, privacy concerns, and the responsibilities of the care team, industry professionals, manufacturers, patients, and caregivers. Both existing and needed clinical evidence were covered, including outcomes of interest for future studies. CONCLUSIONS: Given the expansion of SCS device capabilities, this document provides critical guidance on best practices for using remote device management, although medical necessity should drive all remote monitoring decisions, with individualized patient care. The authors also describe the potential of these emerging technologies to improve outcomes for patients with SCS, although more clinical evidence is needed.


Assuntos
Dor Crônica , Estimulação da Medula Espinal , Humanos , Dor Crônica/terapia , Manejo da Dor , Medula Espinal
16.
Neuromodulation ; 26(7): 1400-1411, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37589641

RESUMO

OBJECTIVE: This study aimed to assess the safety and effectiveness of a new charge-distributed multiphase stimulation paradigm during an extended spinal cord stimulation (SCS) trial. MATERIALS AND METHODS: This prospective, multicenter, randomized, single-blind, feasibility study included participants with chronic low back and/or leg pain and baseline numerical rating scale (NRS) for overall pain intensity ≥6. After a successful commercial SCS trial, participants were randomized to multiphase SCS therapy A (approximately 600-1500 Hz) or B (approximately 300-600 Hz), delivered via an investigational external pulse generator and existing leads during an 11-to-12-day testing period. Primary end points were mean NRS change from baseline to final in-office visit for each multiphase therapy and between therapies. Secondary end points included mean NRS change from end of commercial trial to final study visit and incidence of device-related adverse events (AEs). Additional measures included patient-reported outcomes collected at home through electronic watches and written diaries. Power usage was compared between multiphase and commercial therapies. RESULTS: A total of 122 participants initiated a commercial trial; 77 were randomized to a multiphase arm, and 65 completed the study. Reductions in mean NRS scores from baseline to final study visit were significant for multiphase therapy A and B (-4.3 and -4.7, respectively; both p < 0.0001). There was no statistically significant difference in mean NRS reduction or percent pain relief between multiphase therapies. In an additional analysis, 63.9% of participants reported greater pain relief with multiphase than with commercial SCS therapy in the at-home setting. On average, multiphase required less power than did commercial devices. One non-serious device-related AE was reported, and no infections occurred during the extended trial. CONCLUSIONS: Multiphase SCS effectively reduced pain in participants with chronic low back and/or leg pain during a trial, with no unanticipated device-related AEs reported. Future studies should evaluate long-term effectiveness of multiphase stimulation. CLINICAL TRIAL REGISTRATION: The Clinicaltrials.gov registration number for the study is NCT03594266.


Assuntos
Dor Crônica , Estimulação da Medula Espinal , Humanos , Estimulação da Medula Espinal/efeitos adversos , Estimulação da Medula Espinal/métodos , Dor Crônica/diagnóstico , Dor Crônica/terapia , Perna (Membro) , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Medula Espinal
17.
Reg Anesth Pain Med ; 2023 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-37640452

RESUMO

INTRODUCTION: The evidence for spinal cord stimulation (SCS) has been criticized for the absence of blinded, parallel randomized controlled trials (RCTs) and limited evaluations of the long-term effects of SCS in RCTs. The aim of this study was to determine whether evoked compound action potential (ECAP)-controlled, closed-loop SCS (CL-SCS) is associated with better outcomes when compared with fixed-output, open-loop SCS (OL-SCS) 36 months following implant. METHODS: The EVOKE study was a multicenter, participant-blinded, investigator-blinded, and outcome assessor-blinded, randomized, controlled, parallel-arm clinical trial that compared ECAP-controlled CL-SCS with fixed-output OL-SCS. Participants with chronic, intractable back and leg pain refractory to conservative therapy were enrolled between January 2017 and February 2018, with follow-up through 36 months. The primary outcome was a reduction of at least 50% in overall back and leg pain. Holistic treatment response, a composite outcome including pain intensity, physical and emotional functioning, sleep, and health-related quality of life, and objective neural activation was also assessed. RESULTS: At 36 months, more CL-SCS than OL-SCS participants reported ≥50% reduction (CL-SCS=77.6%, OL-SCS=49.3%; difference: 28.4%, 95% CI 12.8% to 43.9%, p<0.001) and ≥80% reduction (CL-SCS=49.3%, OL-SCS=31.3%; difference: 17.9, 95% CI 1.6% to 34.2%, p=0.032) in overall back and leg pain intensity. Clinically meaningful improvements from baseline were observed at 36 months in both CL-SCS and OL-SCS groups in all other patient-reported outcomes with greater levels of improvement with CL-SCS. A greater proportion of patients with CL-SCS were holistic treatment responders at 36-month follow-up (44.8% vs 28.4%), with a greater cumulative responder score for CL-SCS patients. Greater neural activation and accuracy were observed with CL-SCS. There were no differences between CL-SCS and OL-SCS groups in adverse events. No explants due to loss of efficacy were observed in the CL-SCS group. CONCLUSION: This long-term evaluation with objective measurement of SCS therapy demonstrated that ECAP-controlled CL-SCS resulted in sustained, durable pain relief and superior holistic treatment response through 36 months. Greater neural activation and increased accuracy of therapy delivery were observed with ECAP-controlled CL-SCS than OL-SCS. TRIAL REGISTRATION NUMBER: NCT02924129.

18.
J Pain Res ; 16: 2497-2507, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37497371

RESUMO

Background: Spinal cord stimulation (SCS) is an established chronic pain treatment, but the effectiveness of traditional, open-loop paradigms has been plagued by variable sustainability in a real-world setting. A new approach, utilizing evoked compound action potential (ECAP) controlled closed-loop (CL) SCS, continuously monitors spinal cord activation and automatically adjusts the stimulation amplitude of every pulse, maintaining stimulation at the prescribed ECAP level through this continual feedback mechanism. Recent studies demonstrated the long-term safety and efficacy of ECAP-controlled CL-SCS. Here, we report the design of a prospective, multicenter, single-arm feasibility study to characterize clinical outcomes in a real-world chronic pain population utilizing ECAP-controlled CL-SCS. Objective neurophysiological measurements such as device performance and patient therapy compliance, will be analyzed against baseline biopsychosocial assessments, to explore the clinical utility of these objective physiologic biomarkers in patient phenotyping. Methods: This study will enroll up to 300 subjects with chronic, intractable trunk and/or limb pain in up to 25 United States investigation sites. Subjects meeting eligibility criteria will undergo a trial procedure and a permanent implant following a successful trial. Neurophysiological measurements (measured in-clinic and continuously during home use) and clinical outcomes including pain, quality-of-life, psychological, emotional, and functional assessments will be collected at baseline, trial end, and up to 24-months post-implantation. Discussion: Associations between objective neurophysiological data, clinical evaluation and patient-reported outcomes may have important clinical and scientific implications. They may provide novel insights about the chronic pain pathophysiology, its modulation during CL-SCS, and identification of pain phenotypes and/or mechanisms associated with treatment response during SCS trials and long-term therapy. Data from the ECAP study could lead to improvements in diagnosis, assessment, patient identification and management of chronic pain. It could also provide the foundation for development of a new SCS treatment approach customized by the patient's pain phenotype, unique neurophysiology, and disease severity.

19.
J Pain Res ; 16: 1243-1255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37069943

RESUMO

Background: Lumbar zygapophyseal joint dysfunction represents one of the major sources of chronic low back pain. Radiofrequency ablation (RFA) using a V-shaped active tip needle may offer a larger lesion of the medial branch nerves, improving clinical outcome. The aim of our study is to evaluate the efficacy and the feasibility of RFA using V-shaped active tip needles. Methods: This is a single-center observational retrospective study. Clinical records were screened and analyzed if they met the following inclusion criteria: adult patients (>18 years), diagnosis of chronic lumbar zygapophyseal joint pain, failure of conservative treatments, ability to provide informed consent for data analysis and publication. Exclusion criteria: lumbar pain not related to zygapophyseal joints, previous spinal/lumbar surgery, incomplete data, absence or withdrawal of informed consent. The primary outcome of the study was a change in pain intensity at follow-up. The secondary outcomes were the evaluation of quality-of-life improvement, the occurrence of adverse events and the impact on post-procedural analgesic consumption. For these purposes, pre- and post-treatment numeric rating scale (NRS), neuropathic pain 4 questions (DN4), EuroQoL - EQ-5D-3L, EQ-VAS, EQ-index and North American Spine Society (NASS) index were retrieved and analysed. Results: Sixty-four patients were included. 7.8% of patients at 1-month (CI95% 0.026, 0.173), 37.5% at 3-month (CI95% 0.257, 0.505), 40.6% at 6-month (CI95% 0.285, 0.536) and 35.9% at 9-month (CI95% 0.243, 0.489) follow-up reported a reduction of more than 80% in NRS Statistical analysis indicated a significant change in NRS, DN4, EQ-index and EQ-5D-VAS (p-value <0.001) at the different time-points. Conclusion: RFA using a V-shaped active tip needle might be a feasible and effective treatment for chronic lumbar zygapophyseal joint pain.

20.
Nature ; 615(7950): 50-55, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36859583

RESUMO

The newly discovered nickelate superconductors so far only exist in epitaxial thin films synthesized by a topotactic reaction with metal hydrides1. This method changes the nickelates from the perovskite to an infinite-layer structure by deintercalation of apical oxygens1-3. Such a chemical reaction may introduce hydrogen (H), influencing the physical properties of the end materials4-9. Unfortunately, H is insensitive to most characterization techniques and is difficult to detect because of its light weight. Here, in optimally Sr doped Nd0.8Sr0.2NiO2H epitaxial films, secondary-ion mass spectroscopy shows abundant H existing in the form of Nd0.8Sr0.2NiO2Hx (x ≅ 0.2-0.5). Zero resistivity is found within a very narrow H-doping window of 0.22 ≤ x ≤ 0.28, showing unequivocally the critical role of H in superconductivity. Resonant inelastic X-ray scattering demonstrates the existence of itinerant interstitial s (IIS) orbitals originating from apical oxygen deintercalation. Density functional theory calculations show that electronegative H- occupies the apical oxygen sites annihilating IIS orbitals, reducing the IIS-Ni 3d orbital hybridization. This leads the electronic structure of H-doped Nd0.8Sr0.2NiO2Hx to be more two-dimensional-like, which might be relevant for the observed superconductivity. We highlight that H is an important ingredient for superconductivity in epitaxial infinite-layer nickelates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...