RESUMO
This paper presents the performance of a multi-stage biodrum system applied to domestic wastewater treatment. The organic stabilization and nitrogen removal efficiency in the system was investigated at different hydraulic retention times (HRT) of 12, 6 and 3 hours. The rotational speed of the biodrum was examined at 2,4 and 8 rpm. Average organic removal efficiencies in the system at different HRTs of 12, 6 and 3 hours were 96.3, 94.4 and 90.9%. Simultaneously, average nitrogen removal efficiencies were 91.5, 90.6 and 81.0%. The effect of rotational speed on nitrogen removal efficiencies in the system was clearly observed at a low HRT of 3 hours. The experimental results suggested that optimum HRT in the system was 6 hours. Moreover, they revealed that nitrogen removal efficiencies in the reactors operated at different rotational speed were in the same degree when considering the effluent nitrogen concentration. However, the reactors operated at lower rotational speed needed to employ higher numbers of biodrums (4 stages) than the others with higher rotational speed (3 and 2 stages at 4 and 8 rpm.) in order to achieve similar effluent qualities. At a rotational speed of 2 rpm, maximum nitrogen removal rate was found to be 0.2 kg/m3/d.