Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Transl Radiat Oncol ; 43: 100674, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37753462

RESUMO

We compiled a sampling of the treatment techniques of intensity-modulated total body irradiation, total marrow irradiation and total marrow and lymphoid irradiation utilized by several centers across North America and Europe. This manuscript does not serve as a consensus guideline, but rather is meant to serve as a convenient reference for centers that are considering starting an intensity-modulated program.

2.
J Appl Clin Med Phys ; 23(6): e13613, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35441441

RESUMO

PURPOSE/OBJECTIVES: The aim of this study is to compare intrafractional motion using two commercial non-invasive immobilization systems for linac-based intracranial stereotactic radiosurgery (SRS) under guidance with a surface-guided radiotherapy (SGRT) system. MATERIALS/METHODS: Twenty-one patients who received intracranial SRS were retrospectively selected. Ten patients were immobilized with a vacuum fixation biteplate system, while 11 patients were immobilized with an open-face mask system. A setup margin of 1 mm was used in treatment planning. Real-time surface motion data in 37 treatment fractions using the vacuum fixation system and 44 fractions using the open-face mask were recorded by an SGRT system. Variances of intrafractional motion along three translational directions and three rotational directions were compared between the two immobilization techniques with Levene's tests. Intrafractional motion variation over time during treatments was also evaluated. RESULTS: Using the vacuum fixation system, the average and standard deviations of the shifts were 0.01 ± 0.18 mm, -0.06 ± 0.30 mm, and  0.02 ± 0.26 mm in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions, and -0.02 ± 0.19°, -0.01 ± 0.13°, and 0.01 ± 0.13° for rotations in yaw, roll, and pitch, respectively; using the open-face mask system, the average and standard deviations of the shifts were -0.06 ± 0.20 mm, -0.02 ± 0.35 mm, and 0.01 ± 0.40 mm in the AP, SI, and LR directions, and were 0.05 ± 0.23°, 0.02 ± 0.21°, and 0.00 ± 0.16° for rotations in yaw, roll, and pitch, respectively. There was a significant increase in intrafractional motion variance over time during treatments. CONCLUSION: Patients with the vacuum fixation system had significantly smaller intrafractional motion variation compared to those with the open-face mask system. Using intrafractional motion techniques such as surface imaging system is recommended to minimize dose deviation due to intrafractional motion. The increase in intrafractional motion over time indicates clinical benefits with shorter treatment time.


Assuntos
Radiocirurgia , Humanos , Imobilização/métodos , Posicionamento do Paciente , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos
3.
Med Dosim ; 46(2): 171-178, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33272744

RESUMO

We aimed to compare prototype treatment plans for a new biology-guided radiotherapy (BgRT) machine in its intensity-modulated radiation therapy (IMRT) mode with those using existing IMRT delivery techniques in treatment of nasopharyngeal carcinoma (NPC). We retrospectively selected ten previous NPC patients treated in 33 fractions according to the NRG-HN001 treatment protocol. Three treatment plans were generated for each patient: a helical tomotherapy (HT) plan with a 2.5-cm jaw, a volumetric modulated arc therapy (VMAT) plan using 2 to 4 6-MV arc fields, and a prototype IMRT plan for a new BgRT system which uses a 6-MV photon beam on a ring gantry that rotates at 60 rotations per minute with a couch that moves in small incremental steps. Treatment plans were compared using dosimetric parameters to planning target volumes (PTVs) and organs at risk (OARs) as specified by the NRG-HN001 protocol. Plans for the three modalities had comparable dose coverage, mean dose, and dose heterogeneity to the primary PTV, while the prototype IMRT plans had greater dose heterogeneity to the non-primary PTVs, with the average homogeneity index ranging from 1.28 to 1.50 in the prototype plans. Six of all the 7 OAR mean dose parameters were lower with statistical significance in the prototype plans compared to the HT and VMAT plans with the other mean dose parameter being comparable, and all the 18 OAR maximum dose parameters were comparable or lower with statistical significance in the prototype plans. The average left and right parotid mean doses in the prototype plans were 10.5 Gy and 10.4 Gy lower than those in the HT plans, respectively, and were 5.1 Gy and 5.2 Gy lower than those in the VMAT plans, respectively. Compared to that with the HT and VMAT plans, the treatment time was longer with statistical significance with the prototype IMRT plans. Based on dosimetric comparison of ten NPC cases, the prototype IMRT plans achieved comparable or better critical organ sparing compared to the HT and VMAT plans for definitive NPC radiotherapy. However, there was higher dose heterogeneity to non-primary targets and longer estimated treatment time with the prototype plans.


Assuntos
Neoplasias Nasofaríngeas , Radioterapia de Intensidade Modulada , Biologia , Humanos , Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
4.
Int J Radiat Oncol Biol Phys ; 92(5): 1148-1156, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26050608

RESUMO

PURPOSE: To develop planning and delivery capabilities for linear accelerator-based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position. METHODS AND MATERIALS: An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives and constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose. RESULTS: For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ∼4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were -10.81% ± 6.91%, -27.81% ± 7.39%, -14.82% ± 9.67%, and 39.40% ± 10.53% (P≤.01). CONCLUSIONS: This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.


Assuntos
Algoritmos , Neoplasias da Mama/radioterapia , Aceleradores de Partículas , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Mastectomia Segmentar , Aceleradores de Partículas/instrumentação , Decúbito Ventral , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/instrumentação , Radioterapia de Intensidade Modulada/instrumentação
5.
NMR Biomed ; 28(8): 988-97, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26104980

RESUMO

Perfusion is an important biomarker of tissue function and has been associated with tumor pathophysiology such as angiogenesis and hypoxia. Arterial spin labeling (ASL) MRI allows noninvasive and quantitative imaging of perfusion; however, the application in mouse xenograft tumor models has been challenging due to the low sensitivity and high perfusion heterogeneity. In this study, flow-sensitive alternating inversion recovery (FAIR) ASL was optimized for a mouse xenograft tumor. To assess the sensitivity and reliability for measuring low perfusion, the lumbar muscle was used as a reference region. By optimizing the number of averages and inversion times, muscle perfusion as low as 32.4 ± 4.8 (mean ± standard deviation) ml/100 g/min could be measured in 20 min at 7 T with a quantification error of 14.4 ± 9.1%. Applying the optimized protocol, heterogeneous perfusion ranging from 49.5 to 211.2 ml/100 g/min in a renal carcinoma was observed. To understand the relationship with tumor pathology, global and regional tumor perfusion was compared with histological staining of blood vessels (CD34), hypoxia (CAIX) and apoptosis (TUNEL). No correlation was observed when the global tumor perfusion was compared with these pathological parameters. Regional analysis shows that areas of high perfusion had low microvessel density, which was due to larger vessel area compared with areas of low perfusion. Nonetheless, these were not correlated with hypoxia or apoptosis. The results suggest that tumor perfusion may reflect certain aspect of angiogenesis, but its relationship with other pathologies needs further investigation.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Neoplasias Experimentais/fisiopatologia , Neovascularização Patológica/fisiopatologia , Animais , Linhagem Celular Tumoral , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neoplasias Experimentais/irrigação sanguínea , Neoplasias Experimentais/patologia , Neovascularização Patológica/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
6.
Pflugers Arch ; 462(4): 587-97, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21796340

RESUMO

This article presents a novel model of acupuncture physiology based on cellular calcium activation by an acoustic shear wave (ASW) generated by the mechanical movement of the needle. An acupuncture needle was driven by a piezoelectric transducer at 100 Hz or below, and the ASW in human calf was imaged by magnetic resonance elastography. At the cell level, the ASW activated intracellular Ca(2+) transients and oscillations in fibroblasts and endothelial, ventricular myocytes and neuronal PC-12 cells along with frequency-amplitude tuning and memory capabilities. Monitoring in vivo mammalian experiments with ASW, enhancement of endorphin in blood plasma and blocking by Gd(3+) were observed; and increased Ca(2+) fluorescence in mouse hind leg muscle was imaged by two-photon microscopy. In contrast with traditional acupuncture models, the signal source is derived from the total acoustic energy. ASW signaling makes use of the anisotropy of elasticity of tissues as its waveguides for transmission and that cell activation is not based on the nervous system.


Assuntos
Estimulação Acústica , Terapia por Acupuntura , Sinalização do Cálcio/fisiologia , Músculo Esquelético/fisiologia , Adulto , Animais , Anisotropia , Técnicas de Imagem por Elasticidade , Humanos , Masculino , Camundongos , Modelos Teóricos , Células NIH 3T3 , Células PC12 , Ratos , Coxa da Perna
7.
Biotechnol Lett ; 29(1): 27-35, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17120095

RESUMO

An oxygen transfer model was established for Pichia pastoris growing on glycerol and methanol in a stirred tank bioreactor and expressing a recombinant human serum albumin (rHSA). This was based on pseudo-steady state mass balance, where the volumetric O(2) transfer coefficient, k (L) a, was estimated as a function of power input per unit volume and aeration rate. Under pseudo-steady state, the O(2) transfer rate model matched the O(2) uptake rate obtained from a previous macrokinetic model. This procedure was also applied to estimate biomass concentration by using the on-line rolling identification approach.


Assuntos
Reatores Biológicos/microbiologia , Modelos Biológicos , Oxigênio/metabolismo , Pichia/crescimento & desenvolvimento , Pichia/metabolismo , Albumina Sérica/biossíntese , Proliferação de Células , Simulação por Computador , Humanos , Taxa de Depuração Metabólica , Oxirredução , Pichia/genética , Engenharia de Proteínas/métodos , Proteínas Recombinantes/biossíntese , Albumina Sérica/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA