RESUMO
Tropical plant rubber tree (Hevea brasiliensis) is the sole source of commercial natural rubber and low-temperature stress is the most important limiting factor for its cultivation. To characterize the gene expression profiles of H. brasiliensis under the cold stress and discover the key cold stress-induced genes. Three cDNA libraries, CT (control), LT2 (cold treatment at 4 °C for 2 h) and LT24 (cold treatment at 4 °C for 24 h) were constructed for RNA sequencing (RNA-Seq) and gene expression profiling. Quantitative real time PCR (qRT-PCR) was conducted to validate the RNA-Seq and gene differentially expression results. A total of 1457 and 2328 differentially expressed genes (DEGs) in LT2 and LT24 compared with CT were respectively detected. Most significantly enriched KEGG pathways included flavonoid biosynthesis, phenylpropanoid biosynthesis, plant hormone signal transduction, cutin, suberine and wax biosynthesis, Pentose and glucuronate interconversions, phenylalanine metabolism and starch and sucrose metabolism. A total of 239 transcription factors (TFs) were differentially expressed following 2 h or/and 24 h of cold treatment. Cold-response transcription factor families included ARR-B, B3, BES1, bHLH, C2H, CO-like, Dof, ERF, FAR1, G2-like, GRAS, GRF, HD-ZIP, HSF, LBD, MIKC-MADS, M-type MADS, MYB, MYB-related, NAC, RAV, SRS, TALE, TCP, Trihelix, WOX, WRKY, YABBY and ZF-HD. The genome-wide transcriptional response of rubber tree to the cold treatments were determined and a large number of DEGs were characterized including 239 transcription factors, providing important clues for further elucidation of the mechanisms of cold stress responses in rubber tree.
Assuntos
Resposta ao Choque Frio/genética , Regulação da Expressão Gênica de Plantas , Hevea/genética , Perfilação da Expressão Gênica , Ontologia Genética , Hevea/metabolismo , Análise de Sequência de RNA , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismoRESUMO
OBJECTIVES: This study sought to study the associations of noise with heart rate, blood pressure, and perceived psychological and physiological responses among post-cardiac surgery patients in ICUs. METHODS: Forty patients participated in this study after recovering from anesthesia. A sound-level meter was placed at bedsides to measure noise level for 42 hours, and patients' heart rate and blood pressure were recorded every 5 minutes. Patients were also interviewed for their perceived psychological/physiological responses. RESULTS: The average noise level was between 59.0 and 60.8 dB(A) at the study site. Annoyance and insomnia were the respective psychological and physiological responses reported most often among the patients. Although noise level, irrespective of measures, was not observed to be significantly associated with the self-assessed psychological and physiological responses, it was significantly associated with both heart rate and blood pressure. CONCLUSIONS: Our study demonstrated that the noise in ICUs may adversely affect the heart rate and blood pressure of patients, which warrants the attention of hospital administrators and health care workers.
Assuntos
Período de Recuperação da Anestesia , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Ruído/efeitos adversos , Distúrbios do Início e da Manutenção do Sono/etiologia , Estresse Psicológico/etiologia , Adolescente , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos , Unidades de Cuidados Coronarianos , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Adulto JovemRESUMO
OBJECTIVES: This study sought to study the associations of noise with heart rate, blood pressure, and perceived psychological and physiological responses among post-cardiac surgery patients in ICUs. METHODS: Forty patients participated in this study after recovering from anesthesia. A sound-level meter was placed at bedsides to measure noise level for 42 hours, and patients' heart rate and blood pressure were recorded every 5 minutes. Patients were also interviewed for their perceived psychological/physiological responses. RESULTS: The average noise level was between 59.0 and 60.8 dB(A) at the study site. Annoyance and insomnia were the respective psychological and physiological responses reported most often among the patients. Although noise level, irrespective of measures, was not observed to be significantly associated with the self-assessed psychological and physiological responses, it was significantly associated with both heart rate and blood pressure. CONCLUSIONS: Our study demonstrated that the noise in ICUs may adversely affect the heart rate and blood pressure of patients, which warrants the attention of hospital administrators and health care workers.