Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 310: 123886, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38245968

RESUMO

The understanding of excitonic transitions associated with polymeric aggregates is fundamental, as such transitions have implications on coherence lengths, coherence numbers and inter- and intra-chain binding parameters. In this context, the investigation of efficient solvents and other ways to control polymer aggregate formation is key for their consolidation as materials for new technologies. In this manuscript, we use Poly(3-hexothiophene) (P3HT) as a probe to investigate the significance of amylene (C5H10) and its association with methanol (MeOH) in both pure and C5H10-stabilized chloroform (CHCl3)-based polymeric solutions. Using the intensity ratio between the first and second vibronic transitions of the P3HT H-aggregates formed, values for their exciton bandwidths and interchain interactions are obtained and correlated with the presence of C5H10 and MeOH as agents determining the CHCl3 quality.

2.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796094

RESUMO

Polarimetry is generally used to determine the polarization state of light beams in various research fields, such as biomedicine, astronomy, and materials science. In particular, the rotating quarter-wave plate polarimeter is an inexpensive and versatile option used in several single-wavelength applications to determine the four Stokes parameters. Extending this technique to broadband spectroscopic measurements is of great scientific interest since the information on light polarization is highly sensitive to anisotropic phenomena. However, the need for achromatic polarizing elements, especially quarter-wave plates, requires special attention in their modeling. In this study, we implemented a rotating retarder spectropolarimeter for broadband measurements using a commercially available quasi-achromatic biplate retarder over the visible range. Here, we present a comprehensive approach for troubleshooting this type of spectropolarimeter through the observation of artifacts stemming from the standard single-plate retarder model. Then, we derive a more suitable model for a quasi-achromatic retarder consisting of a biplate junction. This new biplate model requires knowledge of the intrinsic dispersive properties of the biplate, namely the equivalent retardance, fast axis tilt, and rotatory angle. Hence, in this study, we also show a self-consistent methodology to determine these biplate properties using the same polarimeter apparatus so that accurate Stokes parameters can be determined independently. Finally, the comparison of data generated with the standard single-plate and new biplate models shows a significant improvement in the measurement precision of the investigated polarization states, which confirms that remodeling the retarder for reliable spectropolarimetry is necessary.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...