Artigo em Inglês | MEDLINE | ID: mdl-38206451

RESUMO

BACKGROUND: Catheter ablation of persistent atrial fibrillation (PsAF) represents a challenge for the electrophysiologist and there are still divergences regarding the best ablative approach to adopt. Create a new map of the duration of atrial bipolar electrograms (Atrial Electrogram DUration Map, AEDUM) to recognize a functional substrate during sinus rhythm and guide a patient-tailored ablative strategy for PsAF. METHODS: Forty PsAF subjects were assigned in a 1:1 ratio to either for PVI alone (Group B1) or PVI+AEDUM areas ablation (Group B2). A cohort of 15 patients without AF history undergoing left-sided accessory pathway ablation was used as a control group (Group A). In all patients, voltage and AEDUM maps were created during sinus rhythm. The minimum follow-up was 12 months, with rhythm monitoring via 48-h ECG Holter or by implantable cardiac device. RESULTS: Electrogram (EGM) duration was higher in Group B than in Group A (49±16.2ms vs 34.2±3.8ms; p-value<0.001). In Group B the mean cumulative AEDUM area was 21.8±8.2cm2; no difference between the two subgroups was observed (22.3±9.1cm2 vs 21.2±7.2cm2; p-value=0.45). The overall bipolar voltage recorded inside the AEDUM areas was lower than in the remaining atrial areas [median: 1.30mV (IQR: 0.71-2.38mV) vs 1.54mV (IQR: 0.79-2.97mV); p-value: <0.001)]. Low voltage areas (<0.5mV) were recorded in three (7.5%) patients in Group B. During the follow-up [median 511 days (376-845days)] patients who underwent PVI-only experienced more AF recurrence than those receiving a tailored approach (65% vs 35%; p-value= 0.04). CONCLUSIONS: All PsAF patients exhibited AEDUM areas. An ablation approach targeting these areas resulted in a more effective strategy compared with PVI only.

2.
J Interv Card Electrophysiol ; 67(2): 353-361, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37639157

RESUMO

BACKGROUND: Ninety-watt applications are more sensitive to catheter instability and produce lesions that are shallower and smaller in diameter than 50-W applications. These characteristics were considered for the development of a combined (90-50 W) pulmonary vein isolation (PVI) strategy which was prospectively compared to a 50 W-only ablation index (AI)-guided PVI strategy. METHODS: One hundred fifty consecutive paroxysmal AF patients underwent PVI under general anesthesia using CARTO. In the first 75 patients, PVI was performed with a combined (90-50 W) strategy using the QDOT-MICRO catheter in a temperature-controlled mode. This strategy consisted of 90 W-4 s applications on the posterior LA wall (at sites of catheter stability and expectedly thin atrial tissue) with an interlesion distance (ILD) ≤ 4 mm and 50-W applications elsewhere (at sites of catheter instability or expectedly thick atrial tissue) with ILD < 6 mm. In the subsequent 75 patients, PVI was performed with a 50 W-only AI-guided strategy using the SmartTouch-SF catheter in a power-controlled mode. RESULTS: Both groups of patients had similar clinical characteristics and LA dimensions (123.1 ± 24.9 ml vs 119 ± 26.8 ml, P = 0.33). Total procedural times (61 [56-70] vs 65 [60-75] min, P = 0.12), first-pass PVI (82.6 vs 80%, P = 0.81), acute PV reconnection (0 vs 6.6%, P = 0.05), and 1-year SR maintenance (93.3 vs 90.6%, P = 0.57) rates were also similar in both groups of patients. There were no complications in the combined (90-50 W) group while only 2 groin hematomas were reported in the 50 W group. CONCLUSIONS: In paroxysmal AF patients, a combined (90-50 W) strategy for PVI did not improve safety, efficiency, or effectiveness compared to a 50 W-only AI-guided strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fluxo de Trabalho , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Recidiva
3.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37851513

RESUMO

AIMS: The optimal interlesion distance (ILD) for 90 and 50 W radiofrequency applications with low ablation index (AI) values in the atria has not been established. Excessive ILDs can predispose to interlesion gaps, whereas restrictive ILDs can predispose to procedural complications. The present study sought, therefore, to experimentally determine the optimal ILD for 90 W-4 s and 50 W applications with low AI values to optimize catheter ablation outcomes in humans. METHODS AND RESULTS: Posterior intercaval lines were created in eight adult sheep using CARTO and the QDOT-MICRO catheter in a temperature-controlled mode. In four animals, the lines were created with 50 W applications, a target AI value ≥350, and ILDs of 6, 5, 4, and 3 mm, respectively. In the other four animals, the lines were created with 90 W-4 s applications and ILDs of 6, 5, 4, and 3 mm, respectively. Activation maps were created immediately after ablation and at 21 days to assess linear block prior to gross and histological analyses. All eight lines appeared transmural and continuous on histology. However, for 50 W-only applications with an ILD of 3 mm resulted in durable linear electrical block, whereas for 90 W applications, only the lines with ILDs of 4 and 3 mm were blocked. No complications were detected during ablation procedures, but all power and ILD combinations except 50 W-6 mm resulted in asymptomatic shallow lung lesions. CONCLUSION: In the intercaval region in sheep, for 50 W applications with an AI value of ∼370, the optimal ILD is 3 mm, whereas for 90 W-4 s applications, the optimal ILD is 3-4 mm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doenças Pulmonares Intersticiais , Veias Pulmonares , Humanos , Adulto , Animais , Ovinos , Veias Pulmonares/cirurgia , Átrios do Coração/cirurgia , Átrios do Coração/patologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Doenças Pulmonares Intersticiais/patologia , Doenças Pulmonares Intersticiais/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Resultado do Tratamento
4.
Eur Heart J Cardiovasc Imaging ; 24(8): 1082-1091, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-36861644

RESUMO

AIMS: myocardial oedema is largely represented in takotsubo syndrome (TTS) and may contribute to alter the myocardium morphology and function. The aim of the study is to describe relationships between oedema, mechanical, and electrical abnormalities in TTS. METHODS AND RESULTS: the study included n = 32 hospitalized TTS patients and n = 23 controls. Cardiac magnetic resonance (CMR) with tissue mapping and feature tracking was performed with concomitant 12-lead electrocardiogram (ECG) recording. Mean age of TTS was 72 ± 12 years old, 94% women. Compared with controls, patients had higher left ventricular (LV) mass, worse systolic function, higher septal native T1 (1116 ± 73 msec vs. 970 ± 23 msec, P < 0.001), T2 (56 ± 5 msec vs. 46 ± 2 msec, P < 0.001), and extracellular volume (ECV) fraction (32 ± 5% vs. 24 ± 1%, P < 0.001). TTS patients had higher apicobasal gradient of T2 values (12 ± 6 msec vs. 2 ± 6 msec, P < 0.001); basal LV wall displayed higher native T1, T2, and ECV (all P < 0.002) but similar circumferential strain against controls (-23 ± 3% vs. -24 ± 4%, P = 0.351). In the TTS cohort, septal T2 values showed significant correlations with native T1 (r = 0.609, P < 0.001), ECV (r = 0.689, P < 0.001), left ventricular ejection fraction (r = -0.459, P = 0.008) and aVR voltage (r = -0.478, P = 0.009). Negative T-wave voltage and QTc length correlated with apicobasal T2 mapping gradient (r = 0.499, P = 0.007 and r = 0.372, P = 0.047, respectively) but not with other tissue mapping measurements. CONCLUSIONS: CMR T1 and T2 mapping demonstrated increased myocardial water content conditioning interstitial expansion in acute TTS, detected even outside areas of abnormal wall motion. Oedema burden and distribution associated with mechanical and electrocardiographic changes, making it a potential prognostic marker and therapeutic target in TTS.


Assuntos
Cardiomiopatia de Takotsubo , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Espectroscopia de Ressonância Magnética , Edema/diagnóstico por imagem , Edema/patologia , Valor Preditivo dos Testes , Meios de Contraste
5.
Pacing Clin Electrophysiol ; 46(10): 1235-1238, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36811180

RESUMO

Left ventricular (LV) summit premature ventricular contractions (PVCs) are often unresponsive to radiofrequency (RF) ablation. Retrograde venous ethanol infusion (RVEI) can be a valuable alternative in this scenario. A 43-year-old woman without structural heart disease presented with LV summit PVCs unresponsive to RF ablation because of their deep-seated origin. Unipolar pace mapping performed through a wire inserted into a branch of the distal great cardiac vein (GCV) demonstrated 12/12 concordance with the clinical PVCs thus indicating close proximity to PVCs' origin. RVEI abolished the PVCs without complications. Subsequently, magnetic resonance imaging (MRI) evidenced an intramural myocardial scar produced by ethanol ablation. In conclusion, RVEI effectively and safely treated PVC arising from a deep site in the LVS. The scar provoked by chemical damage was well characterized by MRI imaging.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Feminino , Humanos , Adulto , Complexos Ventriculares Prematuros/cirurgia , Cicatriz/cirurgia , Etanol , Ablação por Cateter/métodos , Imageamento por Ressonância Magnética , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 34(2): 270-278, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36434797

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is effective at treating 50% of unselected patients with persistent atrial fibrillation (AF). Alternatively, PVI combined with a new ablation strategy entitled the Marshall-PLAN ensures a 78% 1-year sinus rhythm (SR) maintenance rate in the same population. However, a substantial subset of patients could undergo the Marshall-PLAN unnecessarily. It is therefore essential to identify those patients who can be treated with PVI alone versus those who may truly benefit from the Marshall-PLAN before ablation is performed. In this context, we hypothesized that electrical cardioversion (EC) could help to select the most appropriate strategy for each patient. METHODS: In this multicentre, prospective, randomized study, patients with AF recurrence within 4 weeks after EC will be randomized 1:1 to PVI alone or the Marshall-PLAN. Conversely, patients in whom SR is maintained for ≥4 weeks after EC will be treated with PVI only and included in a prospective registry. The primary endpoint will be the 1-year SR maintenance rate after a single ablation procedure. RESULTS AND CONCLUSION: The Marshall-PLAN might be necessary in patients with an advanced degree of persistent AF (i.e., where SR is not maintained for ≥4 uninterrupted weeks after EC). Conversely, in patients with mild or moderate persistent AF (i.e., where SR is maintained for ≥4 weeks after EC), PVI alone might be a sufficient ablation strategy. The PACIFIC trial is the first study designed to assess whether rhythm monitoring after EC could help to identify patients who should undergo adjunctive ablation strategies beyond PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Cardioversão Elétrica/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Heart Rhythm ; 19(12): 2075-2083, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35964871

RESUMO

BACKGROUND: Abnormal ventricular signals (AVS) are the cornerstone of substrate-based ventricular tachycardia (VT) ablation in sinus rhythm. Signal characterization of AVS in ischemic and nonischemic cardiomyopathies has never been performed. OBJECTIVE: The purpose of this study was to describe ventricular signal abnormalities in 3 different pathologies and examine their association with the diastolic component of VT circuits. METHODS: A total of 45 patients (15 ischemic cardiomyopathy [ICM], 15 arrhythmogenic cardiomyopathy [ACM], 15 dilated cardiomyopathy [DCM]) who had undergone VT ablation with >50% of the diastolic pathway of the VT circuit recorded were studied. AVS were classified into late potentials (LPs) and continuous fractionated ventricular signals (CFVS), and their characteristics and correlation with the diastolic pathway of VT circuits were analyzed. RESULTS: Seventy-five VT circuits were analyzed. Bipolar scars were greatest in ICM endocardially (53 cm2 ICM vs 36 cm2 ACM vs 25 cm2 DCM; P = .010) and in ACM epicardially (98 cm2 ACM vs 25 cm2 ICM vs 24 cm2 DCM; P = .005). Location of the VT diastolic interval coincided with AVS location in 54% of VTs in ICM, 89% in ACM, and 72% in DCM (P = .036). There was a trend toward a greater association of diastolic intervals coinciding with LPs than with CFVS (78% vs 57%; P = .052) (69% diastolic intervals in ICM coincided with LPs, 33% with CFVS; P = .063). All patients (100%) with CFVS in ACM had VT diastolic components arising from CFVS (33% ICM, 64% DCM; P = .049). Positive predictive value for LPs vs CFVS was 77.8% vs 56.7%, and sensitivity was 67.3% vs 32.7%, respectively. CONCLUSION: The nature of abnormal signals in different cardiomyopathies reflects underlying pathology. LPs rather than CFVS seem to be more linked to diastolic components of VT circuits, especially in ICM. LPs have greater sensitivity and specificity for VT; however, CFVS may be of more relevance in ACM.


Assuntos
Cardiomiopatias , Cardiomiopatia Dilatada , Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Lipopolissacarídeos , Resultado do Tratamento , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/cirurgia
8.
JACC Clin Electrophysiol ; 8(5): 561-577, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35589168

RESUMO

OBJECTIVES: This study aimed to evaluate the progression of electrophysiological phenomena in a cohort of patients with paroxysmal atrial fibrillation (PAF) and persistent atrial fibrillation (PsAF). BACKGROUND: Electrical remodeling has been conjectured to determine atrial fibrillation (AF) progression. METHODS: High-density electroanatomic maps during sinus rhythm of 20 patients with AF (10 PAF, 10 PsAF) were compared with 5 healthy control subjects (subjects undergoing ablation of a left-sided accessory pathway). A computational postprocessing of electroanatomic maps was performed to identify specific electrophysiological phenomena: slow conductions corridors, defined as discrete areas of conduction velocity <50 cm/s, and pivot points, defined as sites showing high wave-front curvature documented by a curl module >2.5 1/s. RESULTS: A progressive decrease of mean conduction velocity was recorded across the groups (111.6 ± 55.5 cm/s control subjects, 97.1 ± 56.3 cm/s PAF, and 84.7 ± 55.7 cm/s PsAF). The number and density of slow conduction corridors increase in parallel with the progression of AF (8.6 ± 2.2 control subjects, 13.3 ± 3.2 PAF, and 20.5 ± 4.5 PsAF). In PsAF the atrial substrate is characterized by a higher curvature of wave-front propagation (0.86 ± 0.71 1/s PsAF vs 0.74 ± 0.63 1/s PAF; P = 0.003) and higher number of pivot points (25.1 ± 13.8 PsAF vs 9.5 ± 6.7 PAF; P < 0.0001). Slow conductions: corridors were mostly associated with pivot sites tending to cluster around pulmonary veins antra. CONCLUSIONS: The electrical remodeling hinges mainly on corridors of slow conduction and higher curvature of wave-front propagation. Pivot points associated to SC corridors may be the major determinants for functional localized re-entrant circuits creating the substrate for maintenance of AF.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia
10.
Pacing Clin Electrophysiol ; 45(6): 752-760, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35403246

RESUMO

BACKGROUND: Little is known regarding the characterization of electrical substrate in both atria in patients with atrial fibrillation (AF). METHODS: Eight consecutive patients undergoing AF ablation (five paroxysmal, three persistent) underwent electrical substrate characterization during sinus rhythm. Mapping of the left (LA) and right atrium (RA) was performed with the use of the HD Grid catheter (Abbott). Bipolar voltage maps were analyzed to search for low voltage areas (LVA), the following electrophysiological phenomena were assessed: (1) slow conduction corridors, and (2) lines of block. EGMs were characterized to search for fractionation. Electrical characteristics were compared between atria and between paroxysmal versus persistent AF patients. RESULTS: In the RA, LVAs were present in 60% of patients with paroxysmal AF and 100% of patients with persistent AF. In the LA, LVAs were present in 40% of patients with paroxysmal AF and 66% of patients with persistent AF. The areas of LVA in the RA and LA were 4.8±7.3 cm2 and 7.8±13.6 cm2 in patients with paroxysmal AF versus 11.7±3.0 cm2 and 2.1±1.8 cm2 in patients with persistent AF. In the RA, slow conduction corridors were present in 40.0% (paroxysmal AF) versus 66.7% (persistent AF) whereas in the LA, slow conduction corridors occurred in 20.0% versus 33.3% respectively (p = ns). EGM analysis showed more fractionation in persistent AF patients than paroxysmal (RA: persistent AF 10.8 vs. paroxysmal AF 4.7%, p = .036, LA: 10.3 vs. 4.1%, p = .108). CONCLUSION: Bi-atrial involvement is present in patients with paroxysmal and persistent AF. This is expressed by low voltage areas and slow conduction corridors whose extension progresses as the arrhythmia becomes persistent. This electrophysiological substrate demonstrates the important interplay with the pulmonary vein triggers to constitute the substrate for persistent arrhythmia.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia
11.
G Ital Cardiol (Rome) ; 23(2): 120-127, 2022 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-35343516

RESUMO

BACKGROUND: Transvenous pacing is nowadays the cornerstone of interventional management of bradyarrhythmias. It is still associated, however, with significant complications, mostly related to indwelling transvenous leads or device pocket. In order to reduce these complications, leadless pacemakers have been recently introduced into clinical practice, but no guidelines are yet available to indicate who are those patients that might benefit the most and whether leadless pacing should be preferred in the old or young population. This survey aims to describe the use of leadless pacemaker devices in a real-world setting. METHODS: Eleven arrhythmia centers in the Lombardy region (out of a total of 17 participating centers) responded to the proposed questionnaire regarding patient characteristics and indications to leadless pacing. RESULTS: Out of a total of 411 patients undergoing leadless pacing during 4.2 ± 0.98 years, the median age was 77 years, with 0.18% of patients having less than 18 years, 29.9% 18-65 years, 34.3% 65-80 years and 35.6% >80 years. The most common indication was slow atrial fibrillation (49% of patients), followed by atrioventricular block and sinoatrial dysfunction. Two centers reported in-hospital complications. CONCLUSIONS: Leadless pacemakers proved to be a safe pacing strategy actually destined mostly to elderly patients.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Idoso , Bloqueio Atrioventricular/terapia , Desenho de Equipamento , Humanos , Inquéritos e Questionários
12.
Heart Fail Rev ; 27(1): 271-280, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-32535741

RESUMO

A focal contraction pattern in takotsubo syndrome (TTS) is considered rare. Due to its peculiar presentation, which includes segmental left ventricular (LV) regional wall motion abnormalities (RWMA), the focal TTS pattern may be hardly differentiable from other entities, such as myocarditis or myocardial infarction. We performed a comprehensive systematic literature review researching for works in English published in Journals indexed in Embase, available online for consultation, using the following keywords (in Title and/or Abstract): ("takotsubo" OR "broken heart" OR "apical ballooning" OR "stress cardiomyopathy") AND ("focal" OR "atypical" OR "variant" OR "segments"). Thirty-three papers were retrieved: 17 case reports, 6 case series, and 10 population studies-with a total of 166 focal TTS patients. Prevalence of focal TTS ranged between 0.1% and 14% (pooled mean: 2.8%). Mean age of onset (58 years), gender distribution (80% of females), and type of triggers appeared similar to those reported in typical TTS. RWMA more frequently involved the interventricular septum and the anterolateral LV segments, with often preserved LV ejection fraction. In the majority of focal TTS reports that included adequate ECG information (n = 13), abnormalities were localized and not diffuse, always matching RWMA, and in 3 cases, reciprocal changes were observed. No in-hospital nor long-term deaths were reported. The focal TTS contraction pattern may be more prevalent than currently reported. Though possibly presenting with similar demographic background compared with typical TTS, the focal variant might be characterized by peculiar ECG modifications and better prognosis.


Assuntos
Cardiomiopatia de Takotsubo , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Miocárdio , Volume Sistólico , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/epidemiologia , Função Ventricular Esquerda
13.
Pacing Clin Electrophysiol ; 45(1): 23-34, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34841552

RESUMO

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT). METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography. RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported. CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Dispositivos de Proteção Embólica , Acidente Vascular Cerebral/prevenção & controle , Trombose/cirurgia , Idoso , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Estudos Prospectivos , Dispositivo para Oclusão Septal
14.
Pacing Clin Electrophysiol ; 45(2): 219-228, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34919281

RESUMO

INTRODUCTION: Electrogram (EGM) fractionation is often associated with diseased atrial tissue; however, mechanisms for fractionation occurring above an established threshold of 0.5 mV have never been characterized. We sought to investigate during sinus rhythm (SR) the mechanisms underlying bipolar EGM fractionation with high-density mapping in patients with atrial fibrillation (AF). METHODS: Forty-five patients undergoing AF ablation (73% paroxysmal, 27% persistent) were mapped at high density (18562 ± 2551 points) during SR (Rhythmia). Only bipolar EGMs with voltages above 0.5 mV were considered for analysis. When fractionation (> 40 ms and >4 deflections) was detected, we classified the mechanisms as slow conduction, wave-front collision, or a pivot point. The relationship between EGM duration and amplitude, and tissue anisotropy and slow conduction, was then studied using a computational model. RESULTS: Of the 45 left atria analyzed, 133 sites of EGM fragmentation were identified with voltages above 0.5 mV. The most frequent mechanism (64%) was slow conduction (velocity 0.45 m/s ± 0.2) with mean EGM voltage of 1.1 ± 0.5 mV and duration of 54.9 ± 9.4 ms. Wavefront collision was the second most frequent (19%), characterized by higher voltage (1.6 ± 0.9 mV) and shorter duration (51.3 ± 11.3 ms). Pivot points (9%) were associated with the highest degree of fractionation with 70.7 ± 6.6 ms and 1.8 ± 1 mV. In 10 sites (8%) fractionation was unexplained. The EGM duration was significantly different among the 3 mechanisms (p = .0351). CONCLUSION: In patients with a history of AF, EGM fractionation can occur at amplitudes > 0.5 mV when in SR in areas often considered not to be diseased tissue. The main mechanism of EGM fractionation is slow conduction, followed by wavefront collision and pivot sites.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Idoso , Simulação por Computador , Mapeamento Epicárdico , Feminino , Humanos , Itália , Masculino
15.
J Clin Med ; 10(18)2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34575152

RESUMO

BACKGROUND: after transvenous lead extraction (TLE) of cardiac implantable electric devices (CIEDs), some patients may not benefit from device reimplantation. This study sought to analyse predictors and long-term outcome of patients after TLE with vs. without reimplantation in a high-volume centre. METHODS: all patients undergoing TLE at our centre between January 2010 and November 2015 were included into this analysis. RESULTS: a total of 223 patients (median age 70 years, 22.0% female) were included into the study. Cardiac resynchronization therapy-defibrillator (CRT-D) was the most common device (40.4%) followed by pacemaker (PM) (31.4%), implantable cardioverter-defibrillator (ICD) (26.9%), and cardiac resynchronization therapy-PM (CRT-P) (1.4%). TLE was performed due to infection (55.6%), malfunction (35.9%), system upgrade (6.7%) or other causes (1.8%). In 14.8%, no reimplantation was performed after TLE. At a median follow-up of 41 months, no preventable arrhythmia-related events were documented in the no-reimplantation group, but 11.8% received a new CIED after 17-84 months. While there was no difference in short-term survival, five-year survival was significantly lower in the no-reimplantation group (78.3% vs. 94.7%, p = 0.014). CONCLUSIONS: in patients undergoing TLE, a re-evaluation of the indication for reimplantation is safe and effective. Reimplantation was not related to preventable arrhythmia events, but all-cause survival was lower.

16.
Rev Cardiovasc Med ; 22(3): 597-611, 2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34565063

RESUMO

Takotsubo syndrome (TTS) is an intriguing clinical entity, characterized by usually transient and reversible abnormalities of the left ventricular systolic function, mimicking the myocardial infarction with non-obstructive coronary arteries. TTS was initially regarded as a benign condition, however recent studies have unveiled adverse outcomes in the short- and long-term, with rates of morbidity and mortality comparable to those experienced after an acute myocardial infarction. Given the usual transient nature of TTS, this is an unexpected finding. Moreover, long-term mortality seems to be mainly driven by non-cardiovascular causes. The uncertain long-term prognosis of TTS warrants a comprehensive outpatient follow-up after the acute event, although there are currently no robust data indicating its modality and timing. The aim of the present review is to summarize recent available evidence regarding long-term prognosis in TTS. Moreover methods, timing and findings of the long-term management of TTS will be discussed.


Assuntos
Infarto do Miocárdio , Cardiomiopatia de Takotsubo , Humanos , Prognóstico , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/terapia , Função Ventricular Esquerda
17.
Front Cardiovasc Med ; 8: 703418, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34485402

RESUMO

Takotsubo syndrome (TTS) is an increasingly recognized condition burdened by significant acute and long-term adverse events. The availability of novel techniques expanded the knowledge on TTS and allowed a more accurate risk-stratification, potentially guiding clinical management. The present review aims to summarize the recent advances in TTS prognostic evaluation with a specific focus on novel imaging and genetic markers. Parametric deformation analysis by speckle-tracking echocardiography, as well as tissue characterization by cardiac magnetic resonance imaging T1 and T2 mapping techniques, currently appear the most clinically valuable applications. Notwithstanding, computed tomography and nuclear imaging studies provided limited but promising data. A genetic predisposition to TTS has been hypothesized, though available evidence is still not sufficient. Although a genetic predisposition appears likely, further studies are needed to fully characterize the genetic background of TTS, in order to identify genetic markers that could assist in predicting disease recurrences and help in familial screening.

18.
J Clin Med ; 10(9)2021 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-34063260

RESUMO

BACKGROUND: Optimal antithrombotic therapy after left atrial appendage (LAA) occlusion is still not clear. The aim of this study was to investigate the role of different antithrombotic regimens after the procedure. METHODS AND RESULTS: We retrospectively analyzed data of 260 patients who underwent LAA occlusion and divided them into four groups according to therapy at discharge: dual antiplatelet therapy (group A, 71.5%); oral anticoagulants (group B, 19%); "minimal" antithrombotic therapy (single antiplatelet agent or without any antithrombotic therapy; group C, 4.5%) and other therapeutic regimens (such as a combination of antiplatelets and anticoagulants; group D, 4.5%). We analyzed baseline characteristics, procedural data, and clinical and transesophageal follow-up for each group. The incidence of adverse events was low in the whole population and had a similar distribution among groups. The majority of bleeding events was registered during the first 3 months after the procedure (34 out of 46, 70%). Ischemic events (2%), as well as silent left atrial thrombosis, were rare and not significantly higher in the population discharged with "minimal" antithrombotic therapy. CONCLUSION: Our experience seems to suggest that LAA occlusion was associated with a low incidence of adverse events, regardless of antithrombotic therapy. A "minimal" drug regimen may be feasible without losing efficacy on embolic prevention for patients with high bleeding risk.

19.
Pacing Clin Electrophysiol ; 44(8): 1449-1463, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34081333

RESUMO

Premature ventricular complexes (PVCs) are increasingly recognized, as the use of ECG wearables becomes more widespread. In particular, PVCs arising from both the right ventricular outflow tract (RVOT) and left ventricular outflow tract (LVOT) comprise the majority of these arrhythmias and form a significant component of an electrophysiology practice. A keen understanding of the correlative anatomy of the outflow tracts, in addition to recognizing key ECG indices illustrating PVC sites of origin, are fundamental in preparing for a successful ablation. Patient selection, incorporating symptomatology, structural disease, and PVC burden can pose a challenge, though tools such as the ABC-VT risk score may help identify those patients with a higher risk of clinical deterioration. Utilizing intracardiac echocardiography to highlight salient anatomic features not visible with fluoroscopy allows for a more precise and safer ablation. Interpretation of intracardiac EGMs, and the careful examination for low amplitude highly fractionated pre-potentials, enhanced by the advent of new developed mapping/ablation catheters, remains crucial. Utilizing these tools will guide the electrophysiologist to an efficient and effective outflow tract PVC ablation.


Assuntos
Ecocardiografia/métodos , Eletrocardiografia/métodos , Mapeamento Epicárdico/métodos , Complexos Ventriculares Prematuros/diagnóstico , Ablação por Cateter , Humanos , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
20.
Minerva Cardiol Angiol ; 69(1): 70-80, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33691387

RESUMO

Despite significant advancements in 3D cardiac mapping systems utilized in daily electrophysiology practices, the characterization of atrial substrate remains crucial for the comprehension of supraventricular arrhythmias. During mapping, intracardiac electrograms (EGM) provide specific information that the cardiac electrophysiologist is required to rapidly interpret during the course of a procedure in order to perform an effective ablation. In this review, EGM characteristics collected during sinus rhythm (SR) in patients with paroxysmal atrial fibrillation (pAF) are analyzed, focusing on amplitude, duration and fractionation. Additionally, EGMs recorded during atrial fibrillation (AF), including complex fractionated atrial EGMs (CFAE), may also provide precious information. A complete understanding of their significance remains lacking, and as such, we aimed to further explore the role of CFAE in strategies for ablation of persistent AF. Considering focal atrial tachycardias (AT), current cardiac mapping systems provide excellent tools that can guide the operator to the site of earliest activation. However, only careful analysis of the EGM, distinguishing low amplitude high frequency signals, can reliably identify the absolute best site for RF. Evaluating macro-reentrant atrial tachycardia circuits, specific EGM signatures correspond to particular electrophysiological phenomena: the careful recognition of these EGM patterns may in fact reveal the best site of ablation. In the near future, mathematical models, integrating patient-specific data, such as cardiac geometry and electrical conduction properties, may further characterize the substrate and predict future (potential) reentrant circuits.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...