Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Build Environ ; 207: 108413, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36568650

RESUMO

To control the transport of particles such as the SARS-CoV-2 virus in airliner cabins, which is a significant concern for the flying public, effective ventilation systems are essential. Validated computational fluid dynamics (CFD) models are frequently and effectively used to investigate air distribution and contaminant transportation. The complex geometry and airflow characteristics in airliner cabins pose a challenge to numerical CFD validation. The objective of this investigation was to identify accurate and affordable validation processes for studying the airflow field and particulate contaminant distribution in airliner cabins during the design process for different ventilation systems. This study quantitatively evaluated the effects of ventilation system, turbulence model, particle simulation method, geometry simplification, and boundary condition assignment on airflow and particulate distributions in airliner cabins with either a mixing ventilation (MV) system or a displacement ventilation (DV) system calculated by CFD. The results showed that among four turbulence models, the standard k-ε, RNG k-ε, realizable k-ε and SST k-ω models, the prediction by the realizable k-ε model agreed most closely with the experimental data. Meanwhile, the steady Eulerian method provided a reasonable prediction of the particle concentration field with low computing cost. The computational domain should be simplified differently for the DV system and the MV system with consideration of the simulation accuracy and computing cost. For more accurate modeling results, the boundary conditions should be assigned in greater detail, taking into account the uniformity on the boundary.

3.
Environ Int ; 158: 106999, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34991259

RESUMO

The identification of key VOCs during flights is important in creating a satisfactory aircraft cabin environment. Two VOC databases for the building indoor environment (from 251 occupied residences) and the aircraft cabin environment (from 56 commercial flights) were compared, to determine the common compounds (detection rate (DR) > 70%) in the two environments and the characteristic VOCs (only those with high DR during flights) in aircraft cabins. Possible VOC emission sources in flights were also discussed. As TVOC is usually viewed as a general indicator of air quality, the prediction of TVOC concentration was carried out using BP neural network algorithm, and the average error between the predicted and measured values was 55.35 µg/m3 (R2 = 0.80). Meanwhile, the VOCs' inhalation cancer/non-cancer risks to crew members and passengers were calculated on the basis of detection rates, exposure concentrations, and health risk assessments. Six compounds (i.e., formaldehyde, benzene, tetrachloroethylene, trichloromethane, 1,2-dichloroethane, and naphthalene) were proposed as the key VOCs in the existing aircraft cabin environment, presenting a risk to crew members that is higher than the US EPA proposed acceptable level (evaluated mean value > 1E-06). The estimated lifetime excess cancer/non-cancer risks for passengers were all below the assessment criteria. Based on a summary of various VOC limits in five built environments, hierarchical design of VOC concentration limits is recommended for the aircraft environment.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluição do Ar , Compostos Orgânicos Voláteis , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Aeronaves , Formaldeído/análise , Compostos Orgânicos Voláteis/análise
4.
Build Environ ; 208: 108590, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34812218

RESUMO

The air distribution system in an airliner plays a key role in maintaining a comfortable and healthy environment in the aircraft cabin. To evaluate the performance of a novel displacement ventilation (DV) system and a traditional mixing ventilation (MV) system in an airliner cabin, this study conducted experiments and simulations in a seven-row cabin mockup. This investigation used ultrasonic anemometers and T-thermocouples to measure the air velocity, temperature and distribution of 1 µm and 5 µm particles. Simulation verifications were performed for these operating conditions, and additional scenarios with different occurrence source locations were also simulated. This study combined the Wells-Riley equation with a real case based on a COVID-19 outbreak among passengers on a long-distance bus to obtain the COVID-19 quanta value. Through an evaluation of the airflow organization, thermal comfort, and risk of COVID-19 infection, the two ventilation systems were compared. This investigation found that polydisperse particles should be used to calculate the risk of infection in airliner cabins. In addition, at the beginning of the pandemic, the infection risk with DV was lower than that with MV. In the middle and late stages of the epidemic, the infection risk with MV can be reduced when passengers wear masks, leading to an infection risk approximately equal to that of DV.

5.
Indoor Air ; 31(6): 2084-2098, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34240486

RESUMO

Volatile organic compounds (VOCs) as a non-negligible aircraft cabin air quality (CAQ) factor influence the health and comfort of passengers and crew members. On-board measurements of carbonyls (short-chain (C1 -C6 )) and other volatile organic compounds (VOCs, long-chain (C6 -C16 )) with a total of 350 samples were conducted in 56 commercial airliner cabins covering 8 aircraft models in this study. The mean concentration for each individual carbonyl compound was between 0.3 and 8.3 µg/m3 (except for acrolein & acetone, average = 20.7 µg/m3 ) similar to the mean concentrations of other highly detected VOCs (long-chain (C6 -C16 ), 97% of which ranged in 0-10 µg/m3 ) in aircraft cabins. Formaldehyde concentrations in flights were significantly lower than in residential buildings, where construction materials are known formaldehyde sources. Acetone is a VOC emitted by humans, and its concentration in flights was similar to that in other high-occupant density transportation vehicles. The variation of VOC concentrations in different flight phases of long-haul flights was the same as that of CO2 concentration except for the meal phase, which indicates the importance of cabin ventilation in diluting the gaseous contaminants, while the sustained and slow growth of the VOC concentrations during the cruising phase in short-haul flights indicated that the ventilation could not adequately dilute the emission of VOCs. For the different categories of VOCs, the mean concentration during the cruising phase of benzene series, aldehydes, alkanes, other VOCs (detection rate > 50%), and carbonyls in long-haul flights was 44.2 µg/m3 , 17.9 µg/m3 , 18.6 µg/m3 , 31.5 µg/m3 , and 20.4 µg/m3  lower than those in short-haul flights, respectively. Carbonyls and d-limonene showed a significant correlation with meal service (p < 0.05). Unlike the newly decorated rooms or new vehicles, the inner materials were not the major emission sources in aircraft cabins. Practical Implications. The on-board measurements of 56 flights enrich the VOC database of cabin environment, especially for carbonyls. The literature review of carbonyls in the past 20 years contributes to the understanding the current status of cabin air quality (CAQ). The analysis of VOC concentration variation for different flight phases, flight duration, and aircraft age lays a foundation for exploring effective control methods, including ventilation and purification for cabin VOC pollution. The enriched VOC data is helpful to explore the key VOCs of aircraft cabin environment and to evaluate the acute/chronic health exposure risk of pollutants for passengers and crew members.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluição do Ar , Compostos Orgânicos Voláteis , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Aeronaves , Formaldeído/análise , Humanos , Compostos Orgânicos Voláteis/análise
6.
Build Environ ; 202: 108049, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34155419

RESUMO

During the COVID-19 pandemic, exposure to particles exhaled by infected passengers in commercial aircraft cabins has been a great concern. Currently, aircraft cabins adopt mixing ventilation. However, complete mixing may not be achieved, and thus the particle concentration in the respiratory zone may vary from seat to seat in a cabin. To evaluate the particle exposure in a typical single-aisle aircraft cabin, this investigation constructed an aircraft cabin mockup for experimental tests. Particles were released from a single source or dual sources at different seats to represent particles exhaled by infected passengers. The particle concentrations in the respiratory zones at various seats were measured and compared. The particle exposure was evaluated in both a cross section and a longitudinal section. Leaving the middle seat vacant to reduce particle exposure was also addressed. In addition, the velocity fields and air temperatures were measured to provide a better understanding of particle transport. It was found that the particle exposure at the window seat is always the lowest, regardless of the particle release locations. If the passenger seated in the middle does not release particles, his/her presence enhances the particle dispersion and thereby reduces the particle exposure for adjacent passengers. In the cabin mockup, the released particles can be transported across at least four rows of seats in the longitudinal direction.

8.
Indoor Air ; 29(5): 840-853, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31172603

RESUMO

Ventilation systems for commercial airliner cabins are important in reducing contaminant transport and maintaining thermal comfort. To evaluate the performance of a personalized displacement ventilation system, a conventional displacement ventilation system, and a mixing ventilation system, this study first used the Wells-Riley equation integrated with CFD to obtain the SARS quanta value based on a specific SARS outbreak on a flight. This investigation then compared the three ventilation systems in a seven-row section of a fully occupied, economy-class cabin in Boeing 737 and Boeing 767 airplanes. The SARS quanta generation rate obtained for the index patient could be used in future studies. For all the assumed source locations, the passengers' infection risk by air in the two planes was the highest with the mixing ventilation system, while the conventional displacement ventilation system produced the lowest risk. The personalized ventilation system performed the best in maintaining cabin thermal comfort and can also reduce the infection risk. This system is recommended for airplane cabins.


Assuntos
Aerossóis/efeitos adversos , Poluição do Ar em Ambientes Fechados/efeitos adversos , Aeronaves , Doenças Transmissíveis/transmissão , Ventilação/métodos , Aerossóis/análise , Movimentos do Ar , Poluição do Ar em Ambientes Fechados/análise , Humanos , Manequins , Medição de Risco/métodos
9.
Indoor Air ; 28(6): 852-865, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29981175

RESUMO

Enhanced soiling on the surfaces around air supply nozzles due to particle deposition is frequently observed in commercial airliners. The problem is worsened by severe outdoor air pollution and flight delays in China. The particles in an aircraft cabin originate from both outdoor and in-cabin sources. This study conducted measurements on multiple commercial flights to obtain particle emission rates from in-cabin sources. Additional experiments on a retired MD-82 airplane provided justification of the in-flight measurements. The in-cabin sources emitted more particles during boarding/deplaning than during meal servicing and sitting. The average PM2.5 emission rates were 7.2, 2.6, 1.9, and 1.8 (µg/min per person), respectively, during the boarding/deplaning, sitting on the ground, sitting in the air, and meal servicing. The corresponding PM10 emission rates were 15.4, 6.1, 5.3, and 5.4 (µg/min per person), respectively, for these four periods. The average particle emission rate from in-cabin sources varied seasonally and was the highest in winter. With the measured data, this investigation used a CFD model to predict the accumulation of particles deposited around the nozzles of an airplane, taking into account the flight routes and the outdoor particle concentrations at the airports where the airplanes were parked. For the most polluted airplane in China, the dirty spots/areas around the nozzles inside the airplane became visible after 6 months. The method proposed in this study can be used for any commercial airplane to predict the accumulation of particles deposited around the air supply nozzles.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Aeronaves , Monitoramento Ambiental/métodos , Ventilação/instrumentação , Algoritmos , China
10.
Build Environ ; 137: 41-50, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32287984

RESUMO

In airliner cabins, mixing ventilation systems with gaspers are not efficient in controlling contaminant transport. To improve the cabin environment, this investigation proposed an innovative ventilation system that would reduce contaminant transport and maintain thermal comfort. We manufactured and installed the proposed ventilation system in an occupied seven-row, single-aisle aircraft cabin mockup. Air velocity, air temperature, and contaminant distribution in the cabin mockup were obtained by experimental measurements. The investigation used the experimental data to validate the results of CFD simulation. The validated CFD program was then used to study the impact of the locations and number of exhausts on contaminant removal and thermal comfort in a one-row section of a fully occupied Boeing-737 cabin. Although the diffusers in the proposed system were close to the passengers' legs, the air velocity magnitude was acceptable in the lower part of the cabin and the leg area. The proposed system provided an acceptable thermal environment in the cabin, although passengers could feel cold when placing their legs directly in front of the diffusers. The four-exhaust configuration of the new ventilation system was the best, and it decreased the average exposure in the cabin by 57% and 53%, respectively, when compared with the mixing and displacement ventilation systems.

11.
J Breath Res ; 11(1): 016014, 2017 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-28134131

RESUMO

Expiratory droplets from human coughing have always been considered as potential carriers of pathogens, responsible for respiratory infectious disease transmission. To study the transmission of disease by human coughing, a transient repeatable cough simulator has been designed and built. Cough droplets are generated by different mechanisms, such as the breaking of mucus, condensation and high-speed atomization from different depths of the respiratory tract. These mechanisms in coughing produce droplets of different sizes, represented by a bimodal distribution of 'fine' and 'coarse' droplets. A cough simulator is hence designed to generate transient sprays with such bimodal characteristics. It consists of a pressurized gas tank, a nebulizer and an ejector, connected in series, which are controlled by computerized solenoid valves. The bimodal droplet size distribution is characterized for the coarse droplets and fine droplets, by fibrous collection and laser diffraction, respectively. The measured size distributions of coarse and fine droplets are reasonably represented by the Rosin-Rammler and log-normal distributions in probability density function, which leads to a bimodal distribution. To assess the hydrodynamic consequences of coughing including droplet vaporization and polydispersion, a Lagrangian model of droplet trajectories is established, with its ambient flow field predetermined from a computational fluid dynamics simulation.


Assuntos
Simulação por Computador , Tosse/patologia , Nebulizadores e Vaporizadores , Calibragem , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Modelos Teóricos , Probabilidade , Volatilização
12.
Build Environ ; 111: 110-122, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32287968

RESUMO

It is not clear whether turning on the gaspers in the cabins of commercial airliners actually improves the air quality. To answer this question, this study first developed a hybrid turbulence model which was suitable for predicting the air distribution in an aircraft cabin with gaspers turned on. Next, the investigation validated the model using two sets of experimental data from a cabin mockup and an actual airplane. This study then used the validated model to systematically investigate the impact of gaspers on cabin air quality in a seven-row section of the fully-occupied, economy-class cabin of Boeing 767 and 737 airplanes. The CFD calculations formed a database consisting of 9660 data points that provide information about SARS infection risk. It was found that the distribution of opened gaspers can influence the infection risk for passengers. Even though the gasper supplies clean air, it is possible for it to have a negative impact on the passengers' health. Statistically speaking, the overall effect of turning on the gaspers on the mean infection risk for the general population was neutral.

13.
Build Environ ; 90: 30-36, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32288030

RESUMO

Obtaining information about particle dispersion in a room is crucial in reducing the risk of infectious disease transmission among occupants. This study developed a Markov chain model for quickly obtaining the information on the basis of a steady-state flow field calculated by computational fluid dynamics. When solving the particle transport equations, the Markov chain model does not require iterations in each time step, and thus it can significantly reduce the computing cost. This study used two sets of experimental data for transient particle transport to validate the model. In general, the trends in the particle concentration distributions predicted by the Markov chain model agreed reasonably well with the experimental data. This investigation also applied the model to the calculation of person-to-person particle transport in a ventilated room. The Markov chain model produced similar results to those of the Lagrangian and Eulerian models, while the speed of calculation increased by 8.0 and 6.3 times, respectively, in comparison to the latter two models.

14.
Atmos Environ (1994) ; 85: 223-233, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32372875

RESUMO

The environment of the aircraft cabin greatly influences the comfort and health of passengers and crew members. Contaminant transport has a strong effect on disease spreading in the cabin environment. To obtain the complex cabin contaminant distribution fields accurately and completely, which is also essential to provide solid and precise data for computational fluid dynamics (CFD) model validation, this paper aimed to investigate and improve the method for simultaneous particle and gaseous contaminant fields measurement. The experiment was conducted in a functional MD-82 aircraft. Sulfur hexafluoride (SF6) was used as tracer gas, and Di-Ethyl-Hexyl-Sebacat (DEHS) was used as particulate contaminant. The whole measurement was completed in a part of the economy-class cabin without heating manikins or occupied with heating manikins. The experimental method, in terms of pollutant source setting, sampling points and schedule, was investigated. Statistical analysis showed that appropriately modified sampling grid was able to provide reasonable data. A small difference in the source locations can lead to a significant difference in cabin contaminant fields. And the relationship between gaseous and particulate pollutant transport was also discussed through tracking behavior analysis.

15.
Build Environ ; 62: 45-54, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32288023

RESUMO

It is important to accurately model person-to-person particle transport in mechanical ventilation spaces to create and maintain a healthy indoor environment. The present study introduces a hybrid DES-Lagrangian and RANS-Eulerian model for simulating transient particle transport in enclosed environments; this hybrid model can ensure the accuracy and reduce the computing cost. Our study estimated two key time constants for the model that are important parameters for reducing the computing costs. The two time constants estimated were verified by airflow data from both an office and an aircraft cabin case. This study also conducted experiments in the first-class cabin of an MD-82 commercial airliner with heated manikins to validate the hybrid model. A pulse particle source was applied at the mouth of an index manikin to simulate a cough. The particle concentrations versus time were measured at the breathing zone of the other manikins. The trend of particle concentrations versus time predicted by the hybrid model agrees with the experimental data. Therefore, the proposed hybrid model can be used for investigating transient particle transport in enclosed environments.

16.
Indoor Air ; 22(5): 388-95, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22313168

RESUMO

UNLABELLED: Passengers in an aircraft cabin can have different risks of infection from airborne infectious diseases such as influenza, severe acute respiratory syndrome (SARS), and tuberculosis (TB) because of the non-uniform airflow in an aircraft cabin. The current investigation presents a comprehensive approach to assessing the spatial and temporal distributions of airborne infection risk in an aircraft cabin. A case of influenza outbreak was evaluated in a 4-h flight in a twin-aisle, fully occupied aircraft cabin with the index passenger seated at the center of the cabin. The approach considered the characteristics of the exhalation of the droplets carrying infectious agents from the index passenger, the dispersion of these droplets, and the inhalation of the droplets by susceptible passengers. Deterministic and probabilistic approaches were used to quantify the risks based on the amount of inhaled influenza virus RNA particles and quanta, respectively. The probabilistic approach indicated that the number of secondary infection cases can be reduced from 3 to 0 and 20 to 11, for influenza cases if N95 respirator masks are used by the passengers. The approach and methods developed can easily be implemented in other enclosed spaces such as buildings, trains, and buses to assess the infection risk. PRACTICAL IMPLICATIONS: Airborne infectious disease transmission could take place in enclosed environments such as buildings and transport vehicles. The infection risk is difficult to estimate, and very few mitigation methods are available. This study used a 4-h flight as an example in analyzing the infection risk from influenza and in mitigating the risk with an N95 mask. The results will be useful to the airline industry in providing necessary protection to passengers and crew, and the results can also be used for other enclosed spaces.


Assuntos
Microbiologia do Ar , Movimentos do Ar , Aeronaves , Doenças Transmissíveis/transmissão , Simulação por Computador , Humanos , Hidrodinâmica , Medição de Risco
17.
Build Environ ; 47: 5-12, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32288018

RESUMO

Air distributions in commercial airliner cabins are crucial for creating a thermally comfortable and healthy cabin environment. This paper reviews the methods used in predicting, designing, and analyzing air distributions in the cabins, among which experimental measurements and numerical simulations are the two popular ones. The experimental measurements have usually been seen as more reliable although they are more expensive and time consuming. Most of the numerical simulations use Computational Fluid Dynamics (CFD) that can provide effectively detailed information. Numerous applications using the two methods can be found in the literature for studying air distributions in aircraft cabins, including investigations on more reliable and accurate models. The review in the paper shows that the studies using both experimental measurements and computer simulations are becoming popular. And it is necessary to use a full-scale test rig to obtain reliable and high quality experimental data. What's more, the hybrid CFD models are found to be rather promising for simulating air distributions in airliner cabins.

18.
Indoor Air ; 21(1): 3-11, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21208287

RESUMO

UNLABELLED: The droplets exhaled by an index patient with infectious disease such as influenza or tuberculosis may be the carriers of contagious agents. Indoor environments such as the airliner cabins may be susceptible to infection from such airborne contagious agents. The present investigation computed the transport of the droplets exhaled by the index patient seated in the middle of a seven-row, twin-aisle, fully occupied cabin using the CFD simulations. The droplets exhaled were from a single cough, a single breath, and a 15-s talk of the index patient. The expiratory droplets were tracked by using Lagrangian method, and their evaporation was modeled. It was found that the bulk airflow pattern in the cabin played the most important role on the droplet transport. The droplets were contained in the row before, at, and after the index patient within 30 s and dispersed uniformly to all the seven rows in 4 minutes. The total airborne droplet fraction reduced to 48, 32, 20, and 12% after they entered the cabin for 1, 2, 3, and 4 min, respectively, because of the ventilation from the environmental control system. PRACTICAL IMPLICATIONS: It is critical to predict the risk of airborne infection to take appropriate measures to control and mitigate the risk. Most of the studies in past either assume a homogenous distribution of contaminants or use steady-state conditions. The present study instead provides information on the transient movement of the droplets exhaled by an index passenger in an aircraft cabin. These droplets may contain active contagious agents and can be potent enough to cause infection. The findings can be used by medical professionals to estimate the spatial and temporal distribution of risk of infection to various passengers in the cabin.


Assuntos
Aerossóis , Movimentos do Ar , Aeronaves , Doenças Transmissíveis/transmissão , Tosse , Humanos , Influenza Humana/transmissão , Respiração , Tuberculose/transmissão , Ventilação
19.
Indoor Air ; 20(1): 31-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20028433

RESUMO

UNLABELLED: The exhaled air of infected humans is one of the prime sources of contagious viruses. The exhaled air comes from respiratory events such as the coughing, sneezing, breathing and talking. Accurate information on the thermo-fluid characteristics of the exhaled airflow can be important for prediction of infectious disease transmission. The present study developed a source model to provide the thermo-fluid conditions of the exhaled air from the breathing and talking processes. The source model is a set of equations obtained from the measurements of the flow rate, flow direction, and area of mouth/nose opening with human subjects. It was found that the exhaled flow rate over time can be represented as a sinusoidal function for breathing and a constant for talking. The flow rates can be calculated by physiological parameters of a subject. The direction of the exhalation jet did not vary much between subjects and the area of mouth/nose opening could be regarded as a constant. Though the mouth/nose opening size varied among subjects, they were not correlated with the physiological parameters of the subjects. If combined with appropriate virus and droplet distribution information, the model can be used to describe the disease source due to breathing and talking. PRACTICAL IMPLICATIONS: Accurate prediction of airborne disease transmission, and the infection prone zones, can aid in identifying and implementing the control strategies. With the recent advancements, Computational Fluid Dynamics (CFD) has become a powerful tool in predicting the disease transmission. Accurate prediction of the transmission by these CFD simulations requires information on sources and sinks of infectious viruses and models for dispersion of these viruses. The exhaled air of an infected human is one of the prime sources of disease viruses. In the present study, measurements of the flow were conducted on human subjects to develop models for the flow boundary conditions for the exhalation and inhalation during breathing and talking.


Assuntos
Transmissão de Doença Infecciosa , Expiração/fisiologia , Fala , Feminino , Humanos , Masculino , Material Particulado/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA