Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ther Adv Respir Dis ; 17: 17534666231212307, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38049958

RESUMO

BACKGROUND: Little is known about immediate responses of blood perfusion to the balloon pulmonary angioplasty (BPA) procedure. OBJECTIVES: To investigate the changes in pulmonary perfusion of balloon-dilated vessels and untreated vessels with before, immediately after a single BPA and at follow-up. DESIGN: Retrospective single-center cohort study. METHODS: Patients who had chronic thromboembolic pulmonary hypertension (CTEPH) and completed the pulmonary perfusion single photon emission computed tomography (SPECT) imaging before, immediately after BPA and at follow-up were included. We evaluated the perfusion defects of both-lung, BPA target (balloon dilated) and non-target (untreated) vessel segments according to Begic 3-point scale in each lung segment. RESULTS: Forty patients (40 BPA procedures) were included and were given next BPA after 89 (62-125) days. The hemodynamic parameters including mPAP, PVR, and RAP were significantly improved after a single BPA. Visual scoring results of pulmonary perfusion imaging in 40 BPAs showed the perfusion defect scores of target vessels reduced from 5.6 ± 2.6 to 4.2 ± 2.2 (p < 0.001) immediately after BPA, and then further diminished to 3.1 ± 1.9 (p < 0.001) at follow-up. While in the non-target vessels, the post-BPA perfusion defect scores did not change significantly (13.4 ± 4.7 versus 12.8 ± 4.6, p = 0.182), but tended to decrease at follow-up (12.2 ± 4.2). However, there were 17 BPAs of which the post-BPA perfusion defect scores of non-target vessels increased significantly (p < 0.001), but decreased at follow-up. CONCLUSION: In addition to improving the blood perfusion of target vessels, BPA also has a certain effect on the perfusion of some non-target vessels.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Estudos Retrospectivos , Estudos de Coortes , Doença Crônica , Pulmão/diagnóstico por imagem , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Perfusão , Artéria Pulmonar/diagnóstico por imagem
2.
Pulm Circ ; 13(2): e12234, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37168839

RESUMO

Percutaneous endovascular biopsy (PEB) including forceps biopsy and catheter aspiration has been used to make a pretreatment diagnosis for pulmonary artery (PA) masses. This retrospective study aims to describe the procedure of PEB and compare the diagnostic yield of forceps biopsy and catheter aspiration for a definite diagnosis in patients with PA masses. All consecutive 22 patients (53 ± 14 years), 11 males and 11 females, who underwent PEB for pathologic confirmation between November 2018 and November 2022 were enrolled. All 22 patients performed computed tomography pulmonary angiography or positron emission tomography-computed tomography to confirm the filling defects suspicious for PA malignancy before intervention. And then, all patients underwent PEB successfully without acute or fatal complications, including both forceps biopsy and catheter aspiration in 15 cases, only forceps biopsy in 5 cases, and only catheter aspiration in 2 cases. Histopathological analysis provided a definite diagnosis in all PEBs with a clinical success of 91.0% (20/22). Among them, in 15 patients who underwent both forceps biopsy and aspiration biopsy, the technical success using forceps biopsy was 93.3% (14/15), and aspiration biopsy was 6.7% (1/15), and there was a significant difference in diagnostic accuracy when comparing two techniques. Twenty-one out of 22 PA masses (95.5%) were malignant, of which, the most frequent malignant lesion observed was PA sarcoma (66.7%, 14/21). Benign lesion included one thrombus (4.5%, 1/22). In conclusion, PEB is an effective and safe diagnostic method for differentiating benign and malignant PA masses and could be peformed when PA masses appeared clinically malignant.

3.
Eur J Nucl Med Mol Imaging ; 49(12): 4109-4121, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35732973

RESUMO

OBJECTIVE: To evaluate the diagnostic accuracy of computed tomography pulmonary angiography (CTPA) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for pulmonary artery (PA) masses. METHODS: Of 2889 patients with PA filling defects of PA on CTPA, 79 consecutive patients suspicious for PA malignancy who subsequently underwent 18F-FDG PET/CT were enrolled. All masses were diagnosed on the basis of pathological findings or clinical imaging follow-up. For each mass, morphological CT signs, standardized uptake value (SUVmax and SUVmean), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) on 18F-FDG PET/CT were used as diagnostic markers. RESULTS: Expansive growth, irregular margin, invasion, CT contrast uptake, and wall eclipse sign were strongly associated with the malignant nature of masses. The coexistence of at least 5 CT signs perfectly identified malignant masses, whereas the detection of no more than 4 CT signs did not accurately discriminate between the natures of masses. Mean SUVmax, SUVmean, MTV, and TLG values were significantly higher in malignant masses compared to those in benign masses. The diagnostic accuracy of 18F-FDG PET/CT parameters (SUV, MTV, and TLG) was excellent in detecting malignant masses. Among patients with 3 or 4 pathological CT signs, SUVmax > 3.4 significantly increased the identification of malignancies. CONCLUSIONS: CTPA is a useful imaging modality for diagnosing PA masses, especially when at least 5 abnormal CT signs are identified. Similarly, 18F-FDG PET/CT accurately identified malignant masses and provided additional valuable information on diagnostic uncertainties after CTPA.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Angiografia , Fluordesoxiglucose F18/metabolismo , Glicólise , Prognóstico , Artéria Pulmonar/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Carga Tumoral
4.
Eur Radiol ; 30(12): 6950-6957, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32621239

RESUMO

OBJECTIVES: To investigate the feasibility and accuracy of balloon pulmonary angioplasty (BPA) using DynaCT angiographic reconstruction guidance. METHODS: Thirty-four BPAs (23 CTEPH patients) targeting 175 pulmonary arteries were included. Eleven BPAs (2D group) were guided by DSA two-dimensional angiography. Another twenty-three BPAs (3D group) were guided using DynaCT angiographic reconstruction. The volume rendering (VR) method was used to obtain a three-dimensional image of the blood vessels. This image was used as a reference to continue BPA treatment under the guidance of vascular three-dimensional reconstruction technology. Procedure durations and radiation exposure data were compared between the two groups using Mann-Whitney U test. RESULTS: Using the DynaCT angiographic reconstruction technique, more target vessels were treated in a single BPA procedure (5.83 ± 2.33 vs 3.73 ± 1.10 vessels per BPA, p = 0.008) in a shorter operation time (3.58 ± 0.61 vs 4.49 ± 0.91 h, p = 0.002). Overall, the dose area product (DAP) was significantly higher for the 2D group than for the 3D group (13,901.82 ± 5549.69 vs 4682.82 ± 1950.64, p < 0.001). The use of the DynaCT angiographic reconstruction technique to guide BPA required a lower dose of contrast agent (225.22 ± 48.70 vs 292.73 ± 76.82 mL, p = 0.013) and less radiation exposure. CONCLUSIONS: The use of DynaCT angiographic reconstruction guidance in patients undergoing BPA is feasible and accurate. Images of DynaCT angiographic reconstruction may be beneficial for optimizing the operative process in BPA with reduced radiation exposure. KEY POINTS: • BPA guidance by DynaCT angiographic reconstruction is feasible and accurate. • DynaCT angiographic reconstruction may be beneficial for optimizing the operative process. • DynaCT angiographic reconstruction can reduce patient radiation dose due to multi-times of BPA sessions.


Assuntos
Angioplastia com Balão , Angiografia por Tomografia Computadorizada , Artéria Pulmonar/diagnóstico por imagem , Idoso , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Pulmão , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/terapia , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...