Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1281: 341877, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38783734

RESUMO

BACKGROUND: Oncological analysis is important in tumor diagnosis. We constructed a dual-fluorescence and binary visual analysis system for circulating tumor cells (CTCs) using the folate receptor as a biomarker, combined with hybridization chain reaction and nanomaterial amplification. This strategy integrates terminal protection, selective recognition properties of N-methyl mesoporphyrin IX and CdTe quantum dots for Cu2+ and double-stranded templated copper nanoparticles, and inkjet printing technology. RESULTS: In fluorescence mode, folate receptor and A2780 ovarian cancer cells were specifically detected with a limit of detection of 0.1 fg mL-1, and 10 cells mL-1 were observed. The detection limits of both the color and distance reading modes were comparable to those obtained in fluorescence mode. The applicability of the method for quantifying CTCs was validated using 27 (6 negative and 21 positive) clinical ovarian cancer samples; the results agreed with those of both the clinical folate receptor-polymerase chain reaction kit and radiological and pathological results. SIGNIFICANCE: This dual-fluorescence and binary visual CTCs detection method provides multiple options for clinical tumor liquid biopsy.


Assuntos
Compostos de Cádmio , Células Neoplásicas Circulantes , Neoplasias Ovarianas , Telúrio , Humanos , Feminino , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/sangue , Células Neoplásicas Circulantes/patologia , Telúrio/química , Compostos de Cádmio/química , Pontos Quânticos/química , Linhagem Celular Tumoral , Cobre/química , Fluorescência , Corantes Fluorescentes/química , Biomarcadores Tumorais/sangue , Limite de Detecção , Porfirinas/química
2.
Cancers (Basel) ; 14(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35804977

RESUMO

PURPOSE: Breast immobilization with personalized breast holder (PERSBRA) is a promising approach for normal organ protection during whole breast radiotherapy. The aim of this study is to evaluate the skin surface dose for breast radiotherapy with PERSBRA using different radiotherapy techniques. MATERIALS AND METHODS: We designed PERSBRA with three different mesh sizes (large, fine and solid) and applied them on an anthropomorphic(Rando) phantom. Treatment planning was generated using hybrid, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques to deliver a prescribed dose of 5000 cGy in 25 fractions accordingly. Dose measurement with EBT3 film and TLD were taken on Rando phantom without PERSBRA, large mesh, fine mesh and solid PERSBRA for (a) tumor doses, (b) surface doses for medial field and lateral field irradiation undergoing hybrid, IMRT, VMAT techniques. RESULTS: The tumor dose deviation was less than five percent between the measured doses of the EBT3 film and the TLD among the different techniques. The application of a PERSBRA was associated with a higher dose of the skin surface. A large mesh size of PERSBRA was associated with a lower surface dose. The findings were consistent among hybrid, IMRT, or VMAT techniques. CONCLUSIONS: Breast immobilization with PERSBRA can reduce heart toxicity but leads to a build-up of skin surface doses, which can be improved with a larger mesh design for common radiotherapy techniques.

3.
Nat Commun ; 13(1): 3288, 2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35672323

RESUMO

The three primary colour model, i.e., red, green, and blue model, based on the colour perception of the human eye, has been widely used in colour imaging. The most common approach for obtaining colour information is to use a Bayer colour filter, which filters colour light with four pixels of an imaging sensor to form an effective colour pixel. However, its energy utilization efficiency and colour collection efficiency are limited to a low level due to the three-channel filtering nature. Here, by employing an inverse-design method, we demonstrate a pixel-level metasurface-based Bayer-type colour router that presents peak colour collection efficiencies of 58%, 59%, and 49% for red, green and blue light, and an average energy utilization efficiency as high as 84% over the visible region (400 nm-700 nm), which is twice as high as that of a commercial Bayer colour filter. Furthermore, by using a 200 µm × 200 µm metasurface-based colour router sample working with a monochromatic imaging sensor, colour imaging is further realized, obtaining an image intensity twice that achieved by a commercial Bayer colour filter. Our work innovates the mechanism of high-efficiency spectrum information acquisition, which is expected to have promising applications in the development of next-generation imaging systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...