Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Formos Med Assoc ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38395630

RESUMO

BACKGROUND/PURPOSE: Double-filtration plasmapheresis (DFPP) can be used to remove circulating pathogenic molecules. By reclaiming filtered albumin, DFPP reduces the need for albumin and plasma replacement. Large proteins, such as fibrinogen, are removed. Our institution adopts a DFPP treatment protocol consisting of active surveillance of coagulation profiles and prophylactic supplementation of blood products containing fibrinogen. This study aims to investigate the effects of consecutive DFPP treatments on serial coagulation profiles and the risk of bleeding under this protocol. METHODS: Serial laboratory data and bleeding events at a single tertiary medical center were prospectively collected. Prophylactic transfusion of cryoprecipitate or fresh frozen plasma (FFP) was instituted if significant coagulopathy or a clinically evident bleeding event was observed. RESULTS: After the first treatment session, plasma fibrinogen levels decreased from 332 ± 106 mg/dL to 96 ± 44 mg/dL in the 37 study patients. In the following sessions, plasma fibrinogen levels were maintained at around 100 mg/dL under prophylactic transfusion. No major bleeding events were recorded, but five (14%) patients experienced minor bleeding. CONCLUSION: DFPP treatment might be performed safely along with active monitoring of coagulation profiles and prophylactic transfusion of cryoprecipitate or FFP.

2.
J Formos Med Assoc ; 123(2): 149-158, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37442744

RESUMO

Targeted therapy has emerged as a more precise approach to treat glomerular diseases, focusing on specific molecular or cellular processes that contribute to disease development or progression. This approach complements or replaces traditional immunosuppressive therapy, optimizes supportive care, and provides a more personalized treatment strategy. In this review, we summarize the evolving understanding of pathogenic mechanisms in immune-mediated glomerular diseases and the developing targeted therapies based on these mechanisms. We begin by discussing pan-B-cell depletion, anti-CD20 rituximab, and targeting B-cell survival signaling through the BAFF/APRIL pathway. We also exam specific plasma cell depletion with anti-CD38 antibody. We then shift our focus to complement activation in glomerular diseases, which is involved in antibody-mediated glomerular diseases, such as IgA nephropathy, membranous nephropathy, ANCA-associated vasculitis, and lupus nephritis. Non-antibody-mediated complement activation occurs in glomerular diseases, including C3 glomerulopathy, complement-mediated atypical hemolytic uremic syndrome, and focal segmental glomerulosclerosis. We discuss specific inhibition of terminal, lectin, and alternative pathways in different glomerular diseases. Finally, we summarize current clinical trials targeting the final pathways of various glomerular diseases, including kidney fibrosis. We conclude that targeted therapy based on individualized pathogenesis should be the future of treating glomerular diseases.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos , Glomerulonefrite Membranosa , Nefropatias , Humanos , Nefropatias/tratamento farmacológico , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/tratamento farmacológico , Linfócitos B , Glomerulonefrite Membranosa/tratamento farmacológico , Imunossupressores/uso terapêutico
3.
Microbiol Spectr ; 11(4): e0525622, 2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37289096

RESUMO

The 50% plaque reduction neutralization assay (PRNT50) has been previously used to assess the neutralization capacity of donor plasma against wild-type and variant of concern (VOC) severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Emerging data suggest that plasma with an anti-SARS-CoV-2 level of ≥2 × 104 binding antibody units/mL (BAU/mL) protects against SARS-CoV-2 Omicron BA.1 infection. Specimens were collected using a cross-sectional random sampling approach. For PRNT50 studies, 63 previously analyzed specimens by PRNT50 versus SARS-CoV-2 wild-type, Alpha, Beta, Gamma, and Delta were analyzed by PRNT50 versus Omicron BA.1. The 63 specimens plus 4,390 specimens (randomly sampled regardless of serological evidence of infection) were also tested using the Abbott SARS-CoV-2 IgG II Quant assay (anti-spike [S]; Abbott, Chicago, IL, USA; Abbott Quant assay). In the vaccinated group, the percentages of specimens with any measurable PRNT50 versus wild-type or VOC were wild type (21/25 [84%]), Alpha (19/25 [76%]), Beta (18/25 [72%]), Gamma (13/25 [52%]), Delta (19/25 [76%]), and Omicron BA.1 (9/25 [36%]). In the unvaccinated group, the percentages of specimens with any measurable PRNT50 versus wild type or VOC were wild-type SARS-CoV-2 (16/39 [41%]), Alpha (16/39 [41%]), Beta (10/39 [26%]), Gamma (9/39 [23%]), Delta (16/39 [41%]), and Omicron BA.1 (0/39) (Fisher's exact tests, vaccinated versus unvaccinated for each variant, P < 0.05). None of the 4,453 specimens tested by the Abbott Quant assay had a binding capacity of ≥2 × 104 BAU/mL. Vaccinated donors were more likely than unvaccinated donors to neutralize Omicron when assessed by a PRNT50 assay. IMPORTANCE SARS-CoV-2 Omicron emergence occurred in Canada during the period from November 2021 to January 2022. This study assessed the ability of donor plasma collected earlier (January to March 2021) to generate any neutralizing capacity against Omicron BA.1 SARS-CoV-2. Vaccinated individuals, regardless of infection status, were more likely to neutralize Omicron BA.1 than unvaccinated individuals. This study then used a semiquantitative binding antibody assay to screen a larger number of specimens (4,453) for individual specimens that might have high-titer neutralizing capacity against Omicron BA.1. None of the 4,453 specimens tested by the semiquantitative SARS-CoV-2 assay had a binding capacity suggestive of a high-titer neutralizing capacity against Omicron BA.1. These data do not imply that Canadians lacked immunity to Omicron BA.1 during the study period. Immunity to SARS-CoV-2 is complex, and there is still no wide consensus on correlation of protection to SARS-CoV-2.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Estudos Transversais , Canadá , Doadores de Sangue , Anticorpos Antivirais , Anticorpos Neutralizantes
4.
Viruses ; 15(6)2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37376610

RESUMO

Congenital infections with SARS-CoV-2 are uncommon. We describe two confirmed congenital SARS-CoV-2 infections using descriptive, epidemiologic and standard laboratory methods and in one case, viral culture. Clinical data were obtained from health records. Nasopharyngeal (NP) specimens, cord blood and placentas when available were tested by reverse transcriptase real-time PCR (RT-PCR). Electron microscopy and histopathological examination with immunostaining for SARS-CoV-2 was conducted on the placentas. For Case 1, placenta, umbilical cord, and cord blood were cultured for SARS-CoV-2 on Vero cells. This neonate was born at 30 weeks, 2 days gestation by vaginal delivery. RT-PCR tests were positive for SARS-CoV-2 from NP swabs and cord blood; NP swab from the mother and placental tissue were positive for SARS-CoV-2. Placental tissue yielded viral plaques with typical morphology for SARS-CoV-2 at 2.8 × 102 pfu/mL confirmed by anti-spike protein immunostaining. Placental examination revealed chronic histiocytic intervillositis with trophoblast necrosis and perivillous fibrin deposition in a subchorionic distribution. Case 2 was born at 36 weeks, 4 days gestation. RT-PCR tests from the mother and infant were all positive for SARS-CoV-2, but placental pathology was normal. Case 1 may be the first described congenital case with SARS-CoV-2 cultivated directly from placental tissue.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Gravidez , Chlorocebus aethiops , Recém-Nascido , Animais , Feminino , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Placenta , Células Vero , Trofoblastos , Complicações Infecciosas na Gravidez/diagnóstico , Transmissão Vertical de Doenças Infecciosas
5.
Antimicrob Resist Infect Control ; 12(1): 21, 2023 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-36949510

RESUMO

BACKGROUND: Risk factors for nosocomial COVID-19 outbreaks continue to evolve. The aim of this study was to investigate a multi-ward nosocomial outbreak of COVID-19 between 1st September and 15th November 2020, occurring in a setting without vaccination for any healthcare workers or patients. METHODS: Outbreak report and retrospective, matched case-control study using incidence density sampling in three cardiac wards in an 1100-bed tertiary teaching hospital in Calgary, Alberta, Canada. Patients were confirmed/probable COVID-19 cases and contemporaneous control patients without COVID-19. COVID-19 outbreak definitions were based on Public Health guidelines. Clinical and environmental specimens were tested by RT-PCR and as applicable quantitative viral cultures and whole genome sequencing were conducted. Controls were inpatients on the cardiac wards during the study period confirmed to be without COVID-19, matched to outbreak cases by time of symptom onset dates, age within ± 15 years and were admitted in hospital for at least 2 days. Demographics, Braden Score, baseline medications, laboratory measures, co-morbidities, and hospitalization characteristics were collected on cases and controls. Univariate and multivariate conditional logistical regression was used to identify independent risk factors for nosocomial COVID-19. RESULTS: The outbreak involved 42 healthcare workers and 39 patients. The strongest independent risk factor for nosocomial COVID-19 (IRR 3.21, 95% CI 1.47-7.02) was exposure in a multi-bedded room. Of 45 strains successfully sequenced, 44 (97.8%) were B.1.128 and differed from the most common circulating community lineages. SARS-CoV-2 positive cultures were detected in 56.7% (34/60) of clinical and environmental specimens. The multidisciplinary outbreak team observed eleven contributing events to transmission during the outbreak. CONCLUSIONS: Transmission routes of SARS-CoV-2 in hospital outbreaks are complex; however multi-bedded rooms play a significant role in the transmission of SARS-CoV-2.


Assuntos
COVID-19 , Infecção Hospitalar , Humanos , COVID-19/epidemiologia , SARS-CoV-2/genética , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Estudos de Casos e Controles , Estudos Retrospectivos , Surtos de Doenças , Fatores de Risco , Centros de Atenção Terciária , Alberta
6.
Front Microbiol ; 14: 1289387, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38188566

RESUMO

Introduction: The COVID-19 pandemic was caused by the zoonotic betacoronavirus SARS-CoV-2. SARS-CoV-2 variants have emerged due to adaptation in humans, shifting SARS-CoV-2 towards an endemic seasonal virus. We have termed this process 'virus domestication'. Methods: We analyzed aggregate COVID-19 data from a publicly funded healthcare system in Canada from March 7, 2020 to November 21, 2022. We graphed surrogate calculations of COVID-19 disease severity and SARS-CoV-2 variant plaque sizes in tissue culture. Results and Discussion: Mutations in SARS-CoV-2 adapt the virus to better infect humans and evade the host immune response, resulting in the emergence of variants with altered pathogenicity. We observed a decrease in COVID-19 disease severity surrogates after the arrival of the Delta variant, coinciding with significantly smaller plaque sizes. Overall, we suggest that SARS-CoV-2 has become more infectious and less virulent through viral domestication. Our findings highlight the importance of SARS-CoV-2 vaccination and help inform public policy on the highest probability outcomes during viral pandemics.

7.
Microbiol Spectr ; 10(5): e0281122, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36125288

RESUMO

There is evidence that COVID-19 convalescent plasma may improve outcomes of patients with impaired immune systems; however, more clinical trials are required. Although we have previously used a 50% plaque reduction/neutralization titer (PRNT50) assay to qualify convalescent plasma for clinical trials and virus-like particle (VLP) assays to validate PRNT50 methodologies, these approaches are time-consuming and expensive. Here, we characterized the ability of the Abbott severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG II Quant assay to identify high- and low-titer plasma for wild-type and variant (Alpha, Beta, Gamma, and Delta) SARS-CoV-2 characterized by both VLP assays and PRNT50. Plasma specimens previously tested in wild-type, Alpha, Beta, Gamma, and Delta VLP neutralization assays were selected based on availability. Selected specimens were evaluated by the Abbott SARS-CoV-2 IgG II Quant assay [Abbott anti-Spike (S); Abbott, Chicago, IL], and values in units per milliliter were converted to binding antibody units (BAU) per milliliter. Sixty-three specimens were available for analysis. Abbott SARS-CoV-2 IgG II Quant assay values in BAU per milliliter were significantly different between high- and low-titer specimens for wild-type (Mann-Whitney U = 42, P < 0.0001), Alpha (Mann-Whitney U = 38, P < 0.0001), Beta (Mann-Whitney U = 29, P < 0.0001), Gamma (Mann-Whitney U = 0, P < 0.0001), and Delta (Mann-Whitney U = 42, P < 0.0001). A conservative approach using the highest 95% confidence interval (CI) values from wild-type and variant of concern (VOC) SARS-CoV-2 experiments would identify a potential Abbott SARS-CoV-2 IgG II Quant assay cutoff of ≥7.1 × 103 BAU/mL. IMPORTANCE The United States Food and Drug Administration (FDA) issued an Emergency Use Authorization (EUA) for the use of COVID-19 convalescent plasma (CCP) to treat hospitalized patients with COVID-19 in August 2020. However, by 4 February 2021, the FDA had revised the convalescent plasma EUA. This revision limited the authorization for high-titer COVID-19 convalescent plasma and restricted patient groups to hospitalized patients with COVID-19 early in their disease course or hospitalized patients with impaired humoral immunity. Traditionally our group utilized 50% plaque reduction/neutralization titer (PRNT50) assays to qualify CCP in Canada. Since that time, the Abbott SARS-CoV-2 IgG II Quant assay (Abbott, Chicago IL) was developed for the qualitative and quantitative determination of IgG against the SARS-CoV-2. Here, we characterized the ability of the Abbott SARS-CoV-2 IgG II Quant assay to identify high- and low-titer plasma for wild-type and variant (Alpha, Beta, Gamma, and Delta) SARS-CoV-2.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Anticorpos Antivirais , Imunoglobulina G , Anticorpos Neutralizantes
9.
Arch Pathol Lab Med ; 146(7): 805-813, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35380615

RESUMO

CONTEXT.­: Reverse transcription-polymerase chain reaction (RT-PCR) is the standard method of diagnosing COVID-19. An inconclusive test result occurs when 1 RT-PCR target is positive for SARS-CoV-2 and 1 RT-PCR target is negative for SARS-CoV-2 within the same sample. An inconclusive result generally requires retesting. One reason why a sample may yield an inconclusive result is that one target is at a higher concentration than another target. OBJECTIVE.­: To understand the role of subgenomic RNA transcripts in discordant results from RT-PCR tests for COVID-19. DESIGN.­: A panel of 6 droplet digital PCR assays was designed to quantify the ORF1, E-gene, and N-gene of SARS-CoV-2. This panel was used to quantify viral cultures of SARS-CoV-2 that were harvested during the eclipse phase and at peak infectivity. Eleven clinical nasopharyngeal swabs were also tested with this panel. RESULTS.­: In culture, infected cells showed higher N-gene/ORF1 copy ratios than culture supernatants. The same trends in the relative abundance of copies across different targets observed in infected cells were observed in clinical samples, although trends were more pronounced in infected cells. CONCLUSIONS.­: This study showed that a greater copy number of N-gene relative to E-gene and ORF1 transcripts could potentially explain inconclusive results for some RT-PCR tests on low viral load samples. The use of N-gene RT-PCR target(s) as opposed to ORF1 targets for routine testing is supported by these data.


Assuntos
COVID-19 , COVID-19/diagnóstico , Humanos , RNA , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transcrição Reversa , SARS-CoV-2/genética
10.
PLoS Pathog ; 18(3): e1010392, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35290406

RESUMO

Poxvirus genomes consist of a linear duplex DNA that ends in short inverted and complementary hairpin structures. These elements also encode loops and mismatches that likely serve a role in genome packaging and perhaps replication. We constructed mutant vaccinia viruses (VACV) where the native hairpins were replaced by altered forms and tested effects on replication, assembly, and virulence. Our studies showed that structure, not sequence, likely determines function as one can replace an Orthopoxvirus (VACV) hairpin with one copied from a Leporipoxvirus with no effect on growth. Some loops can be deleted from VACV hairpins with little effect, but VACV bearing too few mismatches grew poorly and we couldn't recover viruses lacking all mismatches. Further studies were conducted using a mutant bearing only one of six mismatches found in wild-type hairpins (SΔ1Δ3-6). This virus grew to ~20-fold lower titers, but neither DNA synthesis nor telomere resolution was affected. However, the mutant exhibited a particle-to-PFU ratio 10-20-fold higher than wild-type viruses and p4b/4b core protein processing was compromised, indicating an assembly defect. Electron microscopy showed that SΔ1Δ3-6 mutant development was blocked at the immature virus (IV) stage, which phenocopies known effects of I1L mutants. Competitive DNA binding assays showed that recombinant I1 protein had less affinity for the SΔ1Δ3-6 hairpin than the wild-type hairpin. The SΔ1Δ3-6 mutant was also attenuated when administered to SCID-NCR mice by tail scarification. Mice inoculated with viruses bearing wild-type hairpins exhibited a median survival of 30-37 days, while mice infected with SΔ1Δ3-6 virus survived >70 days. Persistent infections favor genetic reversion and genome sequencing detected one example where a small duplication near the hairpin tip likely created a new loop. These observations show that mismatches serve a critical role in genome packaging and provide new insights into how VACV "flip and flop" telomeres are arranged.


Assuntos
Nucleotídeos , Vaccinia virus , Animais , DNA , Camundongos , Camundongos SCID , Telômero , Vaccinia virus/genética , Vírion/genética , Replicação Viral/genética
11.
Sci Rep ; 12(1): 5418, 2022 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-35354854

RESUMO

To explore the potential modes of Severe Acute Respiratory Coronavirus-2 (SARS-CoV-2) transmission, we collected 535 diverse clinical and environmental samples from 75 infected hospitalized and community patients. Infectious SARS-CoV-2 with quantitative burdens varying from 5 plaque-forming units/mL (PFU/mL) up to 1.0 × 106 PFU/mL was detected in 151/459 (33%) of the specimens assayed and up to 1.3 × 106 PFU/mL on fomites with confirmation by plaque morphology, PCR, immunohistochemistry, and/or sequencing. Infectious virus in clinical and associated environmental samples correlated with time since symptom onset with no detection after 7-8 days in immunocompetent hosts and with N-gene based Ct values ≤ 25 significantly predictive of yielding plaques in culture. SARS-CoV-2 isolated from patient respiratory tract samples caused illness in a hamster model with a minimum infectious dose of ≤ 14 PFU. Together, our findings offer compelling evidence that large respiratory droplet and contact (direct and indirect i.e., fomites) are important modes of SARS-CoV-2 transmission.


Assuntos
COVID-19 , Humanos , Reação em Cadeia da Polimerase , Sistema Respiratório , SARS-CoV-2/genética
12.
Sci Rep ; 12(1): 3484, 2022 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-35241703

RESUMO

Determining the viral load and infectivity of SARS-CoV-2 in macroscopic respiratory droplets, bioaerosols, and other bodily fluids and secretions is important for identifying transmission modes, assessing risks and informing public health guidelines. Here we show that viral load of SARS-CoV-2 Ribonucleic Acid (RNA) in participants' naso-pharyngeal (NP) swabs positively correlated with RNA viral load they emitted in both droplets >10 [Formula: see text] and bioaerosols <10 [Formula: see text] directly captured during the combined expiratory activities of breathing, speaking and coughing using a standardized protocol, although the NP swabs had [Formula: see text] 10[Formula: see text] more RNA on average. By identifying highly-infectious individuals (maximum of 18,000 PFU/mL in NP), we retrieved higher numbers of SARS-CoV-2 RNA gene copies in bioaerosol samples (maximum of 4.8[Formula: see text] gene copies/mL and minimum cycle threshold of 26.2) relative to other studies. However, all attempts to identify infectious virus in size-segregated droplets and bioaerosols were negative by plaque assay (0 of 58). This outcome is partly attributed to the insufficient amount of viral material in each sample (as indicated by SARS-CoV-2 gene copies) or may indicate no infectious virus was present in such samples, although other possible factors are identified.


Assuntos
Aerossóis , Tosse , Respiração , SARS-CoV-2/isolamento & purificação , Fala , Carga Viral , Humanos
13.
Antimicrob Resist Infect Control ; 11(1): 28, 2022 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-35123573

RESUMO

BACKGROUND: Detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA is completed through reverse transcriptase-PCR (RT-PCR) from either oropharyngeal or nasopharyngeal swabs, critically important for diagnostics but also from an infection control lens. Recent studies have suggested that COVID-19 patients can demonstrate prolonged viral shedding with immunosuppression as a key risk factor. CASE PRESENTATION: We present a case of an immunocompromised patient with SARS-CoV-2 infection demonstrating prolonged infectious viral shedding for 189 days with virus cultivability and clinical relapse with an identical strain based on whole genome sequencing, requiring a multi-modal therapeutic approach. We correlated clinical parameters, PCR cycle thresholds and viral culture until eventual resolution. CONCLUSIONS: We successfully demonstrate resolution of viral shedding, administration of COVID-19 vaccination and maintenance of viral clearance. This case highlights implications in the immunosuppressed patient towards infection prevention and control that should consider those with prolonged viral shedding and may require ancillary testing to fully elucidate viral activity. Furthermore, this case raises several stimulating questions around complex COVID-19 patients around the role of steroids, effect of antiviral therapies in absence of B-cells, role for vaccination and the requirement of a multi-modal approach to eventually have successful clearance of the virus.


Assuntos
COVID-19/patologia , Rituximab/farmacologia , SARS-CoV-2/efeitos dos fármacos , Eliminação de Partículas Virais/efeitos dos fármacos , COVID-19/prevenção & controle , Vacinas contra COVID-19/administração & dosagem , Humanos , Hospedeiro Imunocomprometido , Masculino , Pessoa de Meia-Idade , Nasofaringe , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Viral , Tratamento Farmacológico da COVID-19
14.
Transfusion ; 62(1): 37-43, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34662434

RESUMO

BACKGROUND: This pilot study assesses the ability of plasma collected from Canadian blood donors in the first wave of the SARS-CoV-2 pandemic to neutralize later SARS-CoV-2 variants of concern (VOCs). STUDY DESIGN AND METHODS: A repeated cross-sectional design was used, and a random cross-sectional sample of all available Canadian Blood Services retention samples (n = 1500/month) was drawn monthly for April and May of 2020. Qualitative IgG analysis was performed on aliquots of specimens using anti-spike, anti-receptor binding domain, and anti-nucleocapsid protein enzyme-linked immunosorbent assays as well as the Abbott Architect SARS CoV-2 IgG assay (Abbott Laboratories) against the anti-nucleocapsid protein. Selected plasma specimens were then assessed for neutralization against VOCs using pseudotyped lentivirus inhibition assays as well as plaque reduction neutralization test 50% (PRNT50 ). RESULTS: Six specimens with a high neutralizing titer against wild-type SARS-CoV-2 and three specimens with a low neutralizing titer against wild-type SARS-CoV-2 were chosen for further analysis against VOCs. Four of six high neutralizing titer specimens had a reduced neutralizing capacity against beta VOCs by both neutralization methods. Three of six high neutralizing titer specimens had reduced neutralization capacity against gamma VOCs. CONCLUSIONS: This preliminary data can be used as a justification for limiting the use of first wave plasma products in upcoming clinical trials but cannot be used to speculate on general trends in the immunity of Canadian blood donors to SARS-CoV-2.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Doadores de Sangue , COVID-19 , SARS-CoV-2 , COVID-19/terapia , Canadá , Estudos Transversais , Humanos , Imunização Passiva , Imunoglobulina G/imunologia , Testes de Neutralização , Projetos Piloto , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus , Soroterapia para COVID-19
16.
Infect Control Hosp Epidemiol ; 43(7): 876-885, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34016200

RESUMO

OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic has resulted in shortages of personal protective equipment (PPE), underscoring the urgent need for simple, efficient, and inexpensive methods to decontaminate masks and respirators exposed to severe acute respiratory coronavirus virus 2 (SARS-CoV-2). We hypothesized that methylene blue (MB) photochemical treatment, which has various clinical applications, could decontaminate PPE contaminated with coronavirus. DESIGN: The 2 arms of the study included (1) PPE inoculation with coronaviruses followed by MB with light (MBL) decontamination treatment and (2) PPE treatment with MBL for 5 cycles of decontamination to determine maintenance of PPE performance. METHODS: MBL treatment was used to inactivate coronaviruses on 3 N95 filtering facepiece respirator (FFR) and 2 medical mask models. We inoculated FFR and medical mask materials with 3 coronaviruses, including SARS-CoV-2, and we treated them with 10 µM MB and exposed them to 50,000 lux of white light or 12,500 lux of red light for 30 minutes. In parallel, integrity was assessed after 5 cycles of decontamination using multiple US and international test methods, and the process was compared with the FDA-authorized vaporized hydrogen peroxide plus ozone (VHP+O3) decontamination method. RESULTS: Overall, MBL robustly and consistently inactivated all 3 coronaviruses with 99.8% to >99.9% virus inactivation across all FFRs and medical masks tested. FFR and medical mask integrity was maintained after 5 cycles of MBL treatment, whereas 1 FFR model failed after 5 cycles of VHP+O3. CONCLUSIONS: MBL treatment decontaminated respirators and masks by inactivating 3 tested coronaviruses without compromising integrity through 5 cycles of decontamination. MBL decontamination is effective, is low cost, and does not require specialized equipment, making it applicable in low- to high-resource settings.


Assuntos
COVID-19 , Viroses , COVID-19/prevenção & controle , Descontaminação/métodos , Reutilização de Equipamento , Humanos , Máscaras , Azul de Metileno/farmacologia , Respiradores N95 , Equipamento de Proteção Individual , SARS-CoV-2
17.
Transfusion ; 62(2): 418-428, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34907536

RESUMO

BACKGROUND: Randomized clinical trial data show that early plasma transfusion may save lives among trauma patients. Supplying plasma in remote environments is logistically challenging. Freeze-dried plasma (FDP) offers a possible solution. STUDY DESIGN AND METHODS: A Terumo BCT plasma freeze-drying system was evaluated. We compared pooled frozen plasma (FP) units with derived Terumo BCT FDP (TFDP) units and pooled COVID-19 convalescent apheresis fresh-frozen plasma (CC-AFFP) with derived CC-TFDP units. Parameters measured were: coagulation factors (F) II; V; VII; VIII; IX; XI; XIII; fibrinogen; Proteins C (PC) and S (PS); antithrombin (AT); α2 -antiplasmin (α2 AP); ADAMTS13; von Willebrand Factor (vWF); thrombin-antithrombin (TAT); D-dimer; activated complement factors 3 (C3a) and 5 (C5a); pH; osmolality; prothrombin time (PT); and activated partial thromboplastin time (aPTT). Antibodies to SARS-CoV-2 in CC-AFFP and CC-TFDP units were compared by plaque reduction assays and viral protein immunoassays. RESULTS: Most parameters were unchanged in TFDP versus FP or differed ≤15%. Mean aPTT, PT, C3a, and pH were elevated 5.9%, 6.9%, 64%, and 0.28 units, respectively, versus FP. CC-TFDP showed no loss of SARS-CoV-2 neutralization titer versus CC-AFFP and no mean signal loss in most pools by viral protein immunoassays. CONCLUSION: Changes in protein activities or clotting times arising from freeze-drying were <15%. Although C3a levels in TFDP were elevated, they were less than literature values for transfusable plasma. SARS-CoV-2-neutralizing antibody titers and viral protein binding levels were largely unaffected by freeze-drying. In vitro characteristics of TFDP or CC-TFDP were comparable to their originating plasma, making future clinical studies appropriate.


Assuntos
Remoção de Componentes Sanguíneos , Transfusão de Componentes Sanguíneos , COVID-19 , Liofilização , Antitrombinas , COVID-19/terapia , Canadá , Hemostáticos , Humanos , Imunização Passiva , Plasma , SARS-CoV-2 , Proteínas Virais , Soroterapia para COVID-19
18.
Microbiol Spectr ; 9(3): e0088621, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34787495

RESUMO

The evaluation of humoral protective immunity against SARS-CoV-2 remains crucial in understanding both natural immunity and protective immunity conferred by the several vaccines implemented in the fight against COVID-19. The reference standard for the quantification of antibodies capable of neutralizing SARS-CoV-2 is the plaque-reduction neutralization test (PRNT). However, given that it is a laboratory-developed assay, validation is crucial in order to ensure sufficient specificity and intra- and interassay precision. In addition, a multitude of other serological assays have been developed, including enzyme-linked immunosorbent assay (ELISA), flow cytometry-based assays, luciferase-based lentiviral pseudotype assays, and commercially available human ACE2 receptor-blocking antibody tests, which offer practical advantages in the evaluation of the protective humoral response against SARS-CoV-2. In this study, we validated a SARS-CoV-2 PRNT to assess both 50% and 90% neutralization of SARS-CoV-2 according to guidelines outlined by the World Health Organization. Upon validation, the reference-standard PRNT demonstrated excellent specificity and both intra- and interassay precision. Using the validated assay as a reference standard, we characterized the neutralizing antibody response in specimens from patients with laboratory-confirmed COVID-19. Finally, we conducted a small-scale multilaboratory comparison of alternate SARS-CoV-2 PRNTs and surrogate neutralization tests. These assays demonstrated substantial to perfect interrater agreement with the reference-standard PRNT and offer useful alternatives to assess humoral immunity against SARS-CoV-2. IMPORTANCE SARS-CoV-2, the causal agent of COVID-19, has infected over 246 million people and led to over 5 million deaths as of October 2021. With the approval of several efficacious COVID-19 vaccines, methods to evaluate protective immune responses will be crucial for the understanding of long-term immunity in the rapidly growing vaccinated population. The PRNT, which quantifies SARS-CoV-2-neutralizing antibodies, is used widely as a reference standard to validate new platforms but has not undergone substantial validation to ensure excellent inter- and intraassay precision and specificity. Our work is significant, as it describes the thorough validation of a PRNT, which we then used as a reference standard for the comparison of several alternative serological methods to measure SARS-CoV-2-neutralizing antibodies. These assays demonstrated excellent agreement with the reference-standard PRNT and include high-throughput platforms, which can greatly enhance capacity to assess both natural and vaccine-induced protective immunity against SARS-CoV-2.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Imunidade Humoral/imunologia , Testes de Neutralização/métodos , SARS-CoV-2/imunologia , Enzima de Conversão de Angiotensina 2 , Animais , Anticorpos Neutralizantes , Anticorpos Antivirais/imunologia , Vacinas contra COVID-19/imunologia , Chlorocebus aethiops , Testes Diagnósticos de Rotina , Ensaio de Imunoadsorção Enzimática/métodos , Células HEK293 , Humanos , Imunidade , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Células Vero
19.
Medicine (Baltimore) ; 95(52): e5725, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28033278

RESUMO

INTRODUCTION: In some cases, scleroderma renal crisis (SRC) is not easily distinguishable from other thrombotic microangiopathies such as thrombotic thrombocytopenic purpura, especially when the presentation includes neurological or extra-renal manifestations. Here, we present a case of SRC who developed a rare neurotoxic complication, posterior reversible encephalopathy syndrome (PRES).A 36-year-old man with a history of diffuse cutaneous systemic sclerosis developed SRC and acute-on-chronic renal failure and ultimately required maintenance hemodialysis. Three weeks after starting hemodialysis, the patient presented with confusion and a new-onset seizure disorder. Laboratory examinations revealed thrombocytopenia, a low haptoglobin level, and schizocytes on a blood smear. SRC-related PRES was considered first after PRES was confirmed by brain magnetic resonance imaging. Antihypertensive therapy comprising captopril and amlodipine was administered, and the patient experienced a complete neurological recovery 3 days later without plasma exchange. In all previously reported cases of SRC-associated PRES, PRES developed before hemodialysis. Our report is, therefore, the first to describe a case of onset of SRC-related PRES 3 weeks after the initiation of maintenance hemodialysis. CONCLUSION: This case demonstrates that microangiopathy and extra-renal manifestations can develop even in SRC patients with end-stage renal disease and that these manifestations can be successfully managed with angiotensin-converting enzyme inhibitors (ACEIs) and aggressive blood pressure control. We recommend continuing ACEI therapy if elevated blood pressure persists after maintenance hemodialysis.


Assuntos
Injúria Renal Aguda/etiologia , Síndrome da Leucoencefalopatia Posterior/etiologia , Diálise Renal , Escleroderma Sistêmico/complicações , Injúria Renal Aguda/complicações , Adulto , Humanos , Imageamento por Ressonância Magnética , Masculino , Neuroimagem , Síndrome da Leucoencefalopatia Posterior/diagnóstico por imagem
20.
J Nanosci Nanotechnol ; 12(7): 5742-6, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22966646

RESUMO

A technigal with the polydimethylsiloxane (PDMS) solution infiltrated into the SiOx-coated CNTAs has been utilized to directly transfer the CNTAs away from the silicon substrate. The oxide coating layer was utilized to protect the morpholgy of as-grown patterned vertical aligmed carbon nanotube (CNTs) arrays. The high density plasma reactive ions etching (HDP-RIE) system was used to make the CNTs emerge from the surface of the flexible substrate and modify the crystallines of CNTs. After the protecting oxide was HDP-RIE-processed for 8 min, the emission current properties were enhanced to be 1.03 V/microm and 1.43 V/microm, respectively, for the turn-on field and the threshold field, as compared with 1.25 V/microm and 1.59 V/microm for the as-grown CNTs, accordingly. The Field Emission (FE) enhancement after dry etching could be attributed to the open-ended structures and better crystalline.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...