Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Negl Trop Dis ; 15(7): e0009520, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34264939

RESUMO

Q fever is a worldwide zoonosis caused by Coxiella burnetii (Cb). From January 2018 to November 2019, plasma samples from 2,382 patients with acute fever of unknown cause at a hospital in Zhuhai city of China were tested using metagenomic next-generation sequencing (mNGS). Of those tested, 138 patients (5.8%) were diagnosed with Q fever based on the presence of Cb genomic DNA detected by mNGS. Among these, 78 cases (56.5%) presented from Nov 2018 to Mar 2019, suggesting an outbreak of Q fever. 55 cases with detailed clinical information that occurred during the outbreak period were used for further analysis. The vast majority of plasma samples from those Cb-mNGS-positive patients were positive in a Cb-specific quantitative polymerase chain reaction (n = 38) and/or indirect immunofluorescence assay (n = 26). Mobile phone tracing data was used to define the area of infection during the outbreak. This suggested the probable infection source was Cb-infected goats and cattle at the only official authorized slaughterhouse in Zhuhai city. Phylogenic analysis based on genomic sequences indicated Cb strains identified in the patients, goat and cattle were formed a single branch, most closely related to the genomic group of Cb dominated by strains isolated from goats. Our study demonstrates Q fever was epidemic in 2018-2019 in Zhuhai city, and this is the first confirmed epidemic of Q fever in a contemporary city in China.


Assuntos
Coxiella burnetii/isolamento & purificação , Febre Q/microbiologia , Adulto , Animais , Bovinos , Doenças dos Bovinos/epidemiologia , Doenças dos Bovinos/microbiologia , Doenças dos Bovinos/transmissão , China/epidemiologia , Coxiella burnetii/classificação , Coxiella burnetii/genética , Surtos de Doenças , Feminino , Doenças das Cabras/epidemiologia , Doenças das Cabras/microbiologia , Doenças das Cabras/transmissão , Cabras , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Metagenômica , Pessoa de Meia-Idade , Filogenia , Febre Q/diagnóstico , Febre Q/epidemiologia , Febre Q/transmissão , Adulto Jovem , Zoonoses/diagnóstico , Zoonoses/epidemiologia , Zoonoses/microbiologia , Zoonoses/transmissão
2.
Microsyst Nanoeng ; 3: 16080, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31057850

RESUMO

The measurement of the electrophysiology of human pluripotent stem cell-derived cardiomyocytes is critical for their biomedical applications, from disease modeling to drug screening. Yet, a method that enables the high-throughput intracellular electrophysiology measurement of single cardiomyocytes in adherent culture is not available. To address this area, we have fabricated vertical nanopillar electrodes that can record intracellular action potentials from up to 60 single beating cardiomyocytes. Intracellular access is achieved by highly localized electroporation, which allows for low impedance electrical access to the intracellular voltage. Herein, we demonstrate that this method provides the accurate measurement of the shape and duration of intracellular action potentials, validated by patch clamp, and can facilitate cellular drug screening and disease modeling using human pluripotent stem cells. This study validates the use of nanopillar electrodes for myriad further applications of human pluripotent stem cell-derived cardiomyocytes such as cardiomyocyte maturation monitoring and electrophysiology-contractile force correlation.

3.
Science ; 350(6258): 313-6, 2015 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-26472906

RESUMO

Human skin relies on cutaneous receptors that output digital signals for tactile sensing in which the intensity of stimulation is converted to a series of voltage pulses. We present a power-efficient skin-inspired mechanoreceptor with a flexible organic transistor circuit that transduces pressure into digital frequency signals directly. The output frequency ranges between 0 and 200 hertz, with a sublinear response to increasing force stimuli that mimics slow-adapting skin mechanoreceptors. The output of the sensors was further used to stimulate optogenetically engineered mouse somatosensory neurons of mouse cortex in vitro, achieving stimulated pulses in accordance with pressure levels. This work represents a step toward the design and use of large-area organic electronic skins with neural-integrated touch feedback for replacement limbs.


Assuntos
Mecanorreceptores , Próteses Neurais , Pele/inervação , Tato , Estimulação Elétrica Nervosa Transcutânea/métodos , Animais , Córtex Cerebral/citologia , Córtex Cerebral/fisiologia , Mãos/anatomia & histologia , Mãos/inervação , Mãos/fisiologia , Humanos , Técnicas In Vitro , Camundongos , Optogenética , Pressão , Transistores Eletrônicos
4.
Nat Nanotechnol ; 10(6): 554-62, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25984833

RESUMO

The mechanical stability and deformability of the cell nucleus are crucial to many biological processes, including migration, proliferation and polarization. In vivo, the cell nucleus is frequently subjected to deformation on a variety of length and time scales, but current techniques for studying nuclear mechanics do not provide access to subnuclear deformation in live functioning cells. Here we introduce arrays of vertical nanopillars as a new method for the in situ study of nuclear deformability and the mechanical coupling between the cell membrane and the nucleus in live cells. Our measurements show that nanopillar-induced nuclear deformation is determined by nuclear stiffness, as well as opposing effects from actin and intermediate filaments. Furthermore, the depth, width and curvature of nuclear deformation can be controlled by varying the geometry of the nanopillar array. Overall, vertical nanopillar arrays constitute a novel approach for non-invasive, subcellular perturbation of nuclear mechanics and mechanotransduction in live cells.


Assuntos
Adesão Celular/fisiologia , Núcleo Celular/fisiologia , Núcleo Celular/ultraestrutura , Técnicas de Sonda Molecular/instrumentação , Nanopartículas/ultraestrutura , Nanotecnologia/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Mecanotransdução Celular/fisiologia , Camundongos , Células NIH 3T3 , Nanopartículas/química , Tamanho da Partícula
5.
Nat Methods ; 11(8): 855-60, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24930130

RESUMO

Existing methods for human induced pluripotent stem cell (hiPSC) cardiac differentiation are efficient but require complex, undefined medium constituents that hinder further elucidation of the molecular mechanisms of cardiomyogenesis. Using hiPSCs derived under chemically defined conditions on synthetic matrices, we systematically developed an optimized cardiac differentiation strategy, using a chemically defined medium consisting of just three components: the basal medium RPMI 1640, L-ascorbic acid 2-phosphate and rice-derived recombinant human albumin. Along with small molecule-based induction of differentiation, this protocol produced contractile sheets of up to 95% TNNT2(+) cardiomyocytes at a yield of up to 100 cardiomyocytes for every input pluripotent cell and was effective in 11 hiPSC lines tested. This chemically defined platform for cardiac specification of hiPSCs will allow the elucidation of cardiomyocyte macromolecular and metabolic requirements and will provide a minimal system for the study of maturation and subtype specification.


Assuntos
Miócitos Cardíacos/citologia , Diferenciação Celular , Meios de Cultura , Humanos , Células-Tronco Pluripotentes Induzidas/citologia
6.
PLoS One ; 9(3): e92917, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24667437

RESUMO

It has been proposed that differential activation kinetics allows cells to use a common set of signaling pathways to specify distinct cellular outcomes. For example, nerve growth factor (NGF) and epidermal growth factor (EGF) induce different activation kinetics of the Raf/MEK/ERK signaling pathway and result in differentiation and proliferation, respectively. However, a direct and quantitative linkage between the temporal profile of Raf/MEK/ERK activation and the cellular outputs has not been established due to a lack of means to precisely perturb its signaling kinetics. Here, we construct a light-gated protein-protein interaction system to regulate the activation pattern of the Raf/MEK/ERK signaling pathway. Light-induced activation of the Raf/MEK/ERK cascade leads to significant neurite outgrowth in rat PC12 pheochromocytoma cell lines in the absence of growth factors. Compared with NGF stimulation, light stimulation induces longer but fewer neurites. Intermittent on/off illumination reveals that cells achieve maximum neurite outgrowth if the off-time duration per cycle is shorter than 45 min. Overall, light-mediated kinetic control enables precise dissection of the temporal dimension within the intracellular signal transduction network.


Assuntos
MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Luz , Sistema de Sinalização das MAP Quinases/efeitos da radiação , Neuritos/metabolismo , Neuritos/efeitos da radiação , Quinases raf/metabolismo , Animais , Diferenciação Celular/efeitos dos fármacos , Diferenciação Celular/efeitos da radiação , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Membrana Celular/efeitos da radiação , Criptocromos/química , Criptocromos/metabolismo , Relação Dose-Resposta à Radiação , Ativação Enzimática/efeitos dos fármacos , Ativação Enzimática/efeitos da radiação , Cinética , MAP Quinase Quinase Quinases/metabolismo , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Camundongos , Células NIH 3T3 , Fator de Crescimento Neural/farmacologia , Neuritos/efeitos dos fármacos , Células PC12 , Estrutura Terciária de Proteína , Transporte Proteico/efeitos dos fármacos , Transporte Proteico/efeitos da radiação , Proteínas Proto-Oncogênicas c-raf , Ratos
7.
Nat Commun ; 5: 3206, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24487777

RESUMO

Intracellular recording of action potentials is important to understand electrically-excitable cells. Recently, vertical nanoelectrodes have been developed to achieve highly sensitive, minimally invasive and large-scale intracellular recording. It has been demonstrated that the vertical geometry is crucial for the enhanced signal detection. Here we develop nanoelectrodes of a new geometry, namely nanotubes of iridium oxide. When cardiomyocytes are cultured upon those nanotubes, the cell membrane not only wraps around the vertical tubes but also protrudes deep into the hollow centre. We show that this nanotube geometry enhances cell-electrode coupling and results in larger signals than solid nanoelectrodes. The nanotube electrodes also afford much longer intracellular access and are minimally invasive, making it possible to achieve stable recording up to an hour in a single session and more than 8 days of consecutive daily recording. This study suggests that the nanoelectrode performance can be significantly improved by optimizing the electrode geometry.


Assuntos
Técnicas de Cultura de Células , Irídio/química , Miócitos Cardíacos/fisiologia , Nanotubos/química , Técnicas de Patch-Clamp , Potenciais de Ação , Animais , Linhagem Celular , Eletrodos , Eletroporação , Miócitos Cardíacos/ultraestrutura , Ratos
9.
Nano Lett ; 12(11): 5815-20, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-23030066

RESUMO

Vertically aligned nanopillars can serve as excellent electrical, optical and mechanical platforms for biological studies. However, revealing the nature of the interface between the cell and the nanopillar is very challenging. In particular, a matter of debate is whether the cell membrane remains intact around the nanopillar. Here we present a detailed characterization of the cell-nanopillar interface by transmission electron microscopy. We examined cortical neurons growing on nanopillars with diameter 50-500 nm and heights 0.5-2 µm. We found that on nanopillars less than 300 nm in diameter, the cell membrane wraps around the entirety of the nanopillar without the nanopillar penetrating into the interior of the cell. On the other hand, the cell sits on top of arrays of larger, closely spaced nanopillars. We also observed that the membrane-surface gap of both cell bodies and neurites is smaller for nanopillars than for a flat substrate. These results support a tight interaction between the cell membrane and the nanopillars and previous findings of excellent sealing in electrophysiology recordings using nanopillar electrodes.


Assuntos
Microscopia Eletrônica de Transmissão/métodos , Nanoestruturas/química , Nanotecnologia/métodos , Animais , Biofísica/métodos , Técnicas de Cultura de Células/métodos , Membrana Celular/metabolismo , Eletrodos , Eletrofisiologia/métodos , Humanos , Neurônios/metabolismo , Propriedades de Superfície
10.
Nat Nanotechnol ; 7(3): 185-90, 2012 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-22327876

RESUMO

Action potentials have a central role in the nervous system and in many cellular processes, notably those involving ion channels. The accurate measurement of action potentials requires efficient coupling between the cell membrane and the measuring electrodes. Intracellular recording methods such as patch clamping involve measuring the voltage or current across the cell membrane by accessing the cell interior with an electrode, allowing both the amplitude and shape of the action potentials to be recorded faithfully with high signal-to-noise ratios. However, the invasive nature of intracellular methods usually limits the recording time to a few hours, and their complexity makes it difficult to simultaneously record more than a few cells. Extracellular recording methods, such as multielectrode arrays and multitransistor arrays, are non-invasive and allow long-term and multiplexed measurements. However, extracellular recording sacrifices the one-to-one correspondence between the cells and electrodes, and also suffers from significantly reduced signal strength and quality. Extracellular techniques are not, therefore, able to record action potentials with the accuracy needed to explore the properties of ion channels. As a result, the pharmacological screening of ion-channel drugs is usually performed by low-throughput intracellular recording methods. The use of nanowire transistors, nanotube-coupled transistors and micro gold-spine and related electrodes can significantly improve the signal strength of recorded action potentials. Here, we show that vertical nanopillar electrodes can record both the extracellular and intracellular action potentials of cultured cardiomyocytes over a long period of time with excellent signal strength and quality. Moreover, it is possible to repeatedly switch between extracellular and intracellular recording by nanoscale electroporation and resealing processes. Furthermore, vertical nanopillar electrodes can detect subtle changes in action potentials induced by drugs that target ion channels.


Assuntos
Potenciais de Ação/fisiologia , Técnicas Citológicas/métodos , Eletroporação/instrumentação , Eletroporação/métodos , Espaço Intracelular/fisiologia , Nanoestruturas , Potenciais de Ação/efeitos dos fármacos , Animais , Linhagem Celular , Moduladores de Transporte de Membrana/farmacologia , Camundongos
11.
J Phys Chem A ; 114(38): 10427-34, 2010 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-20809640

RESUMO

We report a detailed study of luminescence switching in the fluorescent zinc sensor Zinpyr-1 by density functional methods. A two-pronged approach employing both time-dependent density functional theory (TDDFT) and constrained density functional theory (CDFT) is used to characterize low-lying electronically excited states of the sensor. The calculations indicate that fluorescence activation in the sensor is governed by a photoinduced electron transfer mechanism in which the energy level ordering of the excited states is altered by binding Zn(2+). While the sensor is capable of binding two Zn(2+) cations, a single Zn(2+) ion appears to be sufficient to activate moderate fluorescence in aqueous solution at physiological pH. We show that it is reasonable to consider the tertiary amine as the effective electron donor in this system, although the pyridyl nitrogens each contribute some density to the xanthone ring. The calculations illustrate an important design principle: because protonation equilibria at receptor sites can play a determining role in the sensor's fluorescence response, receptor sites with a pK(a) near the pH of the sample are to be disfavored if a sensor governed by a simple PET fluorescence quenching model is desired.


Assuntos
Fluoresceínas/química , Fluorescência , Corantes Fluorescentes/química , Simulação de Dinâmica Molecular , Zinco/análise , Transporte de Elétrons , Estrutura Molecular , Compostos Organometálicos/química , Fotoquímica , Estereoisomerismo
12.
Nano Lett ; 10(10): 4020-4, 2010 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-20815404

RESUMO

Cell migration in a cultured neuronal network presents an obstacle to selectively measuring the activity of the same neuron over a long period of time. Here we report the use of nanopillar arrays to pin the position of neurons in a noninvasive manner. Vertical nanopillars protruding from the surface serve as geometrically better focal adhesion points for cell attachment than a flat surface. The cell body mobility is significantly reduced from 57.8 µm on a flat surface to 3.9 µm on nanopillars over a 5 day period. Yet, neurons growing on nanopillar arrays show a growth pattern that does not differ in any significant way from that seen on a flat substrate. Notably, while the cell bodies of neurons are efficiently anchored by the nanopillars, the axons and dendrites are free to grow and elongate into the surrounding area to develop a neuronal network, which opens up opportunities for long-term study of the same neurons in connected networks.


Assuntos
Nanoestruturas/química , Neurônios/citologia , Alicerces Teciduais/química , Animais , Adesão Celular , Técnicas de Cultura de Células/métodos , Movimento Celular , Nanoestruturas/ultraestrutura , Ratos , Silício/química , Dióxido de Silício/química
13.
Opt Express ; 17(25): 22609-15, 2009 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-20052186

RESUMO

We demonstrate second harmonic generation in photonic crystal nanocavities fabricated in the semiconductor gallium phosphide. We observe second harmonic radiation at 750 nm with input powers of only nanowatts coupled to the cavity and conversion effciency P(out)/P(2)(in,coupled)=430%/W. The large electronic band gap of GaP minimizes absorption loss, allowing effcient conversion. Our results are promising for integrated, low-power light sources and on-chip reduction of input power in other nonlinear processes.


Assuntos
Gálio/química , Lasers , Iluminação/instrumentação , Nanoestruturas/química , Nanotecnologia/instrumentação , Fosfinas/química , Desenho Assistido por Computador , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Nanoestruturas/ultraestrutura , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...