Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
BMJ Glob Health ; 8(Suppl 2)2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37160360

RESUMO

BACKGROUND: Standardised measures on experience of care are essential to understanding the care women and newborns receive and to designing appropriate interventions and responses. This review builds on ongoing work in the realm of maternity care and complements it by reviewing existing tools and measures to assess experience of and satisfaction with the care of the newborn. METHODS: We conducted a scoping review of published literature to identify measures and tools of experience (physiological or indirect) and satisfaction with newborn care. We systematically searched five bibliographic databases from 1 January 2010 through 1 December 2022 and contacted professional networks. Using a predefined evidence template, we extracted data on the studies and the tools' characteristics. We mapped the tools and measures against the WHO quality of care frameworks to identify the most frequent measured domains of care and to highlight existing gaps. RESULT: We identified 18 292 records of which 72 were eligible. An innovative finding of this review is the inclusion of newborn perspectives through behavioural responses, physiological signals, pain profiles as well as other non-verbal cues as markers of newborn experience. Domains related to parental participation and decision-making, ensuring continuity of care and receiving coordinated care, were the most measured across the included tools. CONCLUSION: Comprehensive and validated instruments measuring all aspects of care are needed. Developing a robust theoretical ground will be fundamental to the design and utilisation of standardised tools and measures. PROTOCOL REGISTRATION DETAILS: This review was registered and published on protocol.io (dx.doi.org/10.17504/protocols.io.bvk7n4zn).


Assuntos
Serviços de Saúde Materna , Feminino , Humanos , Recém-Nascido , Masculino , Gravidez , Satisfação Pessoal
3.
Int J Gynaecol Obstet ; 159 Suppl 1: 22-38, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36530007

RESUMO

OBJECTIVE: To explore the quality of maternal and newborn care (QMNC) during the COVID-19 pandemic by facility type among 16 European countries, comparing rates of instrumental vaginal birth and cesarean. METHODS: Women who gave birth in the WHO European Region from March 1, 2020, to February 7, 2022, answered a validated online questionnaire. Rates of instrumental birth, instrumental vaginal birth, and cesarean, and a QMNC index were calculated for births in public versus private facilities. RESULTS: Responses from 25 206 participants were analyzed. Women giving birth in private compared with public facilities reported significantly more frequent total cesarean (32.5% vs 19.0%; aOR 1.70; 95% CI 1.52-1.90), elective cesarean (17.3% vs 7.8%; aOR 1.90; 95% CI 1.65-2.19), and emergency cesarean before labor (7.4% vs 3.9%; aOR 1.39; 95% CI 1.14-1.70) (P < 0.001 for all comparisons), with analyses by country confirming these results. QMNC index results were heterogeneous across countries and regions in the same country and were largely affected by geographical distribution of regions rather than by type of facility alone. CONCLUSION: The study confirms that births in private facilities have higher odds of cesarean. It also suggests that QMNC should be closely monitored in all facilities to achieve high-quality care, independent of facility type or geographical distribution. GOV IDENTIFIER: NCT04847336.


Assuntos
COVID-19 , Cesárea , Feminino , Humanos , Recém-Nascido , Gravidez , COVID-19/epidemiologia , Saúde do Lactente , Pandemias , Logradouros Públicos
5.
BMJ Open ; 12(4): e056753, 2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35396296

RESUMO

OBJECTIVES: Develop and validate a WHO Standards-based online questionnaire to measure the quality of maternal and newborn care (QMNC) around the time of childbirth from the health workers' perspective. DESIGN: Mixed-methods study. SETTING: Six countries of the WHO European Region. PARTICIPANTS AND METHODS: The questionnaire is based on lessons learnt in previous studies, and was developed in three sequential phases: (1) WHO Quality Measures were prioritised and content, construct and face validity were assessed through a Delphi involving a multidisciplinary board of experts from 11 countries of the WHO European Region; (2) translation/back translation of the English version was conducted following The Professional Society for Health Economics and Outcomes Research guidelines; (3) internal consistency, intrarater reliability and acceptability were assessed among 600 health workers in six countries. RESULTS: The questionnaire included 40 items based on WHO Standards Quality Measures, equally divided into four domains: provision of care, experience of care, availability of human and physical resources, organisational changes due to COVID-19; and its organised in six sections. It was translated/back translated in 12 languages: Bosnian, Croatian, French, German, Italian, Norwegian, Portuguese, Romanian, Russian, Slovenian, Spanish and Swedish. The Cronbach's alpha values were ≥0.70 for each questionnaire section where questions were hypothesised to be interrelated, indicating good internal consistence. Cohen K or Gwet's AC1 values were ≥0.60, suggesting good intrarater reliability, except for one question. Acceptability was good with only 1.70% of health workers requesting minimal changes in question wording. CONCLUSIONS: Findings suggest that the questionnaire has good content, construct, face validity, internal consistency, intrarater reliability and acceptability in six countries of the WHO European Region. Future studies may further explore the questionnaire's use in other countries, and how to translate evidence generated by this tool into policies to improve the QMNC. TRAIL REGISTRATION NUMBER: NCT04847336.


Assuntos
COVID-19 , Feminino , Humanos , Recém-Nascido , Gravidez , Psicometria , Qualidade da Assistência à Saúde , Reprodutibilidade dos Testes , Inquéritos e Questionários , Organização Mundial da Saúde
6.
Glob Health Sci Pract ; 9(1): 160-176, 2021 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-33795367

RESUMO

BACKGROUND: A critical shortage of health workers with needed maternal and newborn competencies remains a major challenge for the provision of quality care for mothers and newborns, particularly in low- and middle-income countries. Supply-side challenges related to human resources for health (HRH) worsen shortages and can negatively affect health worker performance and quality of care. This review scoped country-focused sources to identify and map evidence on HRH-related challenges to quality facility-based newborn care provision by nurses and midwives. METHODS: Evidence for this review was collected iteratively, beginning with pertinent World Health Organization documents and extending to articles identified via database and manual reference searches and country reports. Evidence from country-focused sources from 2000 onward was extracted using a data extraction tool that was designed iteratively; thematic analysis was used to map the 10 categories of HRH challenges. FINDINGS: A total of 332 peer-reviewed articles were screened, of which 22 met inclusion criteria. Fourteen additional sources were added from manual reference search and gray literature sources. Evidence has been mapped into 10 categories of HRH-related challenges: (1) lack of health worker data and monitoring; (2) poor health worker preservice education; (3) lack of HW access to evidence-based practice guidelines, continuing education, and continuing professional development; (4) insufficient and inequitable distribution of health workers and heavy workload; (5) poor retention, absenteeism, and rotation of experienced staff; (6) poor work environment, including low salary; (7) limited and poor supervision; (8) low morale, motivation, and attitude, and job dissatisfaction; (9) weaknesses of policy, regulations, management, leadership, governance, and funding; and (10) structural and contextual barriers. CONCLUSION: The mapping provides needed insight that informed new World Health Organization strategies and supporting efforts to address the challenges identified and strengthen human resources for neonatal care, with the ultimate goal of improving newborn care and outcomes.


Assuntos
Países em Desenvolvimento , Tocologia , Feminino , Pessoal de Saúde , Humanos , Recém-Nascido , Gravidez , Qualidade da Assistência à Saúde , Recursos Humanos
7.
BMC Pregnancy Childbirth ; 21(Suppl 1): 237, 2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33765946

RESUMO

BACKGROUND: Immediate newborn care (INC) practices, notably early initiation of breastfeeding (EIBF), are fundamental for newborn health. However, coverage tracking currently relies on household survey data in many settings. "Every Newborn Birth Indicators Research Tracking in Hospitals" (EN-BIRTH) was an observational study validating selected maternal and newborn health indicators. This paper reports results for EIBF. METHODS: The EN-BIRTH study was conducted in five public hospitals in Bangladesh, Nepal, and Tanzania, from July 2017 to July 2018. Clinical observers collected tablet-based, time-stamped data on EIBF and INC practices (skin-to-skin within 1 h of birth, drying, and delayed cord clamping). To assess validity of EIBF measurement, we compared observation as gold standard to register records and women's exit-interview survey reports. Percent agreement was used to assess agreement between EIBF and INC practices. Kaplan Meier survival curves showed timing. Qualitative interviews were conducted to explore barriers/enablers to register recording. RESULTS: Coverage of EIBF among 7802 newborns observed for ≥1 h was low (10.9, 95% CI 3.8-21.0). Survey-reported (53.2, 95% CI 39.4-66.8) and register-recorded results (85.9, 95% CI 58.1-99.6) overestimated coverage compared to observed levels across all hospitals. Registers did not capture other INC practices apart from breastfeeding. Agreement of EIBF with other INC practices was high for skin-to-skin (69.5-93.9%) at four sites, but fair/poor for delayed cord-clamping (47.3-73.5%) and drying (7.3-29.0%). EIBF and skin-to-skin were the most delayed and EIBF rarely happened after caesarean section (0.5-3.6%). Qualitative findings suggested that focusing on accuracy, as well as completeness, contributes to higher quality with register reporting. CONCLUSIONS: Our study highlights the importance of tracking EIBF despite measurement challenges and found low coverage levels, particularly after caesarean births. Both survey-reported and register-recorded data over-estimated coverage. EIBF had a strong agreement with skin-to-skin but is not a simple tracer for other INC indicators. Other INC practices are challenging to measure in surveys, not included in registers, and are likely to require special studies or audits. Continued focus on EIBF is crucial to inform efforts to improve provider practices and increase coverage. Investment and innovation are required to improve measurement.


Assuntos
Aleitamento Materno/estatística & dados numéricos , Confiabilidade dos Dados , Assistência Perinatal/estatística & dados numéricos , Qualidade da Assistência à Saúde , Adolescente , Adulto , Bangladesh , Cesárea , Feminino , Humanos , Recém-Nascido , Masculino , Nepal , Assistência Perinatal/organização & administração , Gravidez , Pesquisa Qualitativa , Sistema de Registros/estatística & dados numéricos , Fatores Socioeconômicos , Inquéritos e Questionários/estatística & dados numéricos , Tanzânia , Fatores de Tempo , Adulto Jovem
8.
BMC Pregnancy Childbirth ; 21(Suppl 1): 235, 2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33765958

RESUMO

BACKGROUND: Annually, 14 million newborns require stimulation to initiate breathing at birth and 6 million require bag-mask-ventilation (BMV). Many countries have invested in facility-based neonatal resuscitation equipment and training. However, there is no consistent tracking for neonatal resuscitation coverage. METHODS: The EN-BIRTH study, in five hospitals in Bangladesh, Nepal, and Tanzania (2017-2018), collected time-stamped data for care around birth, including neonatal resuscitation. Researchers surveyed women and extracted data from routine labour ward registers. To assess accuracy, we compared gold standard observed coverage to survey-reported and register-recorded coverage, using absolute difference, validity ratios, and individual-level validation metrics (sensitivity, specificity, percent agreement). We analysed two resuscitation numerators (stimulation, BMV) and three denominators (live births and fresh stillbirths, non-crying, non-breathing). We also examined timeliness of BMV. Qualitative data were collected from health workers and data collectors regarding barriers and enablers to routine recording of resuscitation. RESULTS: Among 22,752 observed births, 5330 (23.4%) babies did not cry and 3860 (17.0%) did not breathe in the first minute after birth. 16.2% (n = 3688) of babies were stimulated and 4.4% (n = 998) received BMV. Survey-report underestimated coverage of stimulation and BMV. Four of five labour ward registers captured resuscitation numerators. Stimulation had variable accuracy (sensitivity 7.5-40.8%, specificity 66.8-99.5%), BMV accuracy was higher (sensitivity 12.4-48.4%, specificity > 93%), with small absolute differences between observed and recorded BMV. Accuracy did not vary by denominator option. < 1% of BMV was initiated within 1 min of birth. Enablers to register recording included training and data use while barriers included register design, documentation burden, and time pressure. CONCLUSIONS: Population-based surveys are unlikely to be useful for measuring resuscitation coverage given low validity of exit-survey report. Routine labour ward registers have potential to accurately capture BMV as the numerator. Measuring the true denominator for clinical need is complex; newborns may require BMV if breathing ineffectively or experiencing apnoea after initial drying/stimulation or subsequently at any time. Further denominator research is required to evaluate non-crying as a potential alternative in the context of respectful care. Measuring quality gaps, notably timely provision of resuscitation, is crucial for programme improvement and impact, but unlikely to be feasible in routine systems, requiring audits and special studies.


Assuntos
Confiabilidade dos Dados , Morte Perinatal/prevenção & controle , Respiração com Pressão Positiva/estatística & dados numéricos , Ressuscitação/estatística & dados numéricos , Adolescente , Adulto , Bangladesh/epidemiologia , Feminino , Humanos , Recém-Nascido , Nascido Vivo , Masculino , Máscaras/estatística & dados numéricos , Nepal/epidemiologia , Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/métodos , Gravidez , Sistema de Registros/estatística & dados numéricos , Ressuscitação/instrumentação , Ressuscitação/métodos , Natimorto , Inquéritos e Questionários/estatística & dados numéricos , Tanzânia/epidemiologia , Adulto Jovem
11.
Acta Paediatr ; 109(11): 2278-2286, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32027398

RESUMO

AIM: Building strategies for the country-level dissemination of Kangaroo mother care (KMC) to reduce the mortality rate in preterm and low birth weight babies and improve quality of life. KMC is an evidence-based healthcare method for these infants. However, KMC implementation at the global level remains low. METHODS: The international network in Kangaroo mother brought 172 KMC professionals from 33 countries together for a 2-day workshop held in conjunction with the XIIth International KMC Conference in Bogota, Colombia, in November 2018. Participants worked in clusters to formulate strategies for country-level dissemination and scale-up according to seven pre-established objectives. RESULTS: The minimum set of indicators for KMC scale-up proposed by the internationally diverse groups is presented. The strategies for KMC integration and implementation at the country level, as well as the approaches for convincing healthcare providers of the safety of KMC transportation, are also described. Finally, the main aspects concerning KMC follow-up and KMC for term infants are presented. CONCLUSION: In this collaborative meeting, participants from low-, middle- and high-income countries combined their knowledge and experience to identify the best strategies to implement KMC at a countrywide scale.


Assuntos
Método Canguru , Criança , Colômbia , Feminino , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido de Baixo Peso , Recém-Nascido , Qualidade de Vida
12.
J Glob Health ; 10(2): 020433, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33403105

RESUMO

BACKGROUND: Information about the use of the findings of quality assessments in maternal and neonatal (MN) care is lacking and the development of tools capable to effectively address quality gaps is a key priority. Furthermore, little is known about factors that act as barriers or facilitators to change at facility level. Based on the extensive experience made with the WHO Quality Assessment and Improvement MN (QA/QI MN) tool, an overview is provided of the improvements in quality of care (QoC) which were obtained over time and of the factors influencing change. METHODS: All documented reports on the implementation of the WHO QA/QI MN tool were searched and screened for inclusion. Reports were considered if bringing evidence from both the baseline assessment and the reassessment. Changes were considered in four domains: maternal care, neonatal care, infrastructure and policies, with reference made to WHO maternal and neonatal care standards. The observed improvements were categorized according to intensity and extent across the sample of health facilities. Factors influencing change were categorized into internal and external and further classified as barriers or facilitators. RESULTS: Changes were documented after an average period of 1.2 years from first assessment in 27 facilities belonging to 9 different countries in Central and Eastern Europe (3), Central Asia (3), sub-Saharan Africa (2) and Latin America (1). Improvements were observed in all areas of care but were greater and more frequently observed in areas related to appropriate case management and respectful care for both mothers and newborns. Although widespread across most facilities and countries, the observed improvements were not covering all the quality gaps observed at the baseline assessment nor were always sufficient to achieve standard care. Factors facilitating change as well as barriers were mainly related to the capacity of the managers and head of units to involve and motivate their staff members. CONCLUSIONS: The use of WHO QA/QI MN tool proved effective in promoting significant changes in quality of care. The review of observed improvements and of factors influencing change at facility level shows that participatory assessment tools that promote a constructive dialogue with hospital managers and staff and support them in acquiring capacity in this role are crucial to implement effective quality cycles.


Assuntos
Serviços de Saúde da Criança , Serviços de Saúde Materna , Garantia da Qualidade dos Cuidados de Saúde , Melhoria de Qualidade , África Subsaariana , Ásia , Europa (Continente) , Feminino , Hospitais , Humanos , Recém-Nascido , América Latina , Gravidez
13.
J Glob Health ; 10(2): 020432, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33403104

RESUMO

BACKGROUND: A substantial proportion of maternal and neonatal mortality and morbidity is attributable to gaps in quality of care. A systematic, standard-based tool for quality assessment and improvement for maternal and neonatal hospital care (QA/QI MN tool) was developed in 2009 by the World Health Organization (WHO). The tool guides the assessment process along the whole continuum from admission to discharge, collects the views of the recipients of care and engages hospital mangers and staff in identifying gaps and drafting an action plan. METHODS: Publications describing use of the WHO QA/QI MN tool from 2009 to 2017 and reports retrievable from WHO or other development partners' websites were searched and considered for inclusion in the review. Only assessments of hospitals were considered. Quality gaps were classified as regarding case management in maternal care, case management in neonatal care, hospital infrastructure, hospital policies and according to severity and frequency. Quotations from women regarding key issues in effective communication, respect and dignity, emotional support and costs incurred were selected. RESULTS: In the period 2009-2017, use of the WHO QA/QI MN tool was documented in 25 countries, belonging to Central and Eastern Europe (8), Central Asia (4), Sub-Saharan Africa (11), Latin America (1) and Middle East (1). Overall, 133 hospitals were assessed. The tool allowed to identify in great detail serious quality gaps including: insufficient or incomplete adherence to recommended evidence-based procedures for normal childbirth and maternal and neonatal complications; excess of inappropriate or unnecessary interventions; insufficient infection control; failure to provide respectful care, adequate communication and emotional support to mothers and babies; poor use of information generated locally to analyse processes and outcomes. These gaps were observed in all countries. Significant differences were observed among facilities belonging to the same health systems, ie, with very similar staffing, infrastructure and equipment. CONCLUSIONS: The experience made, the largest of this kind, provides comprehensive and detailed insight into the existing quality gaps in a wide variety of settings. QI cycles at facility level should be primarily based on assessments made by multidisciplinary teams of professionals to identify the parts of the care pathways which require improvement through a participatory approach involving managers, staff and patients.


Assuntos
Hospitais , Garantia da Qualidade dos Cuidados de Saúde , Melhoria de Qualidade , África Subsaariana , Ásia , Serviços de Saúde da Criança , Europa (Continente) , Feminino , Humanos , Recém-Nascido , América Latina , Serviços de Saúde Materna , Oriente Médio , Gravidez
16.
J Pediatric Infect Dis Soc ; 7(3): e107-e115, 2018 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-30007329

RESUMO

BACKGROUND: With the continued high prevalence of chlamydia worldwide and high risk of transfer from mothers to their infant during delivery, a need for safe and effective therapies for infants who acquire a chlamydial infection remains. We conducted a systematic review and meta-analysis of antibiotic treatments, including oral erythromycin, azithromycin, and trimethoprim, for neonatal chlamydial conjunctivitis. METHODS: We searched Medline, Embase, and the Cochrane Central Register of Controlled Trials (CENTRAL) from their inception to July 14, 2017. We included randomized and nonrandomized studies that evaluated the effects of erythromycin, azithromycin, or trimethoprim in neonates with chlamydial conjunctivitis. A meta-analysis using a random-effects generic inverse-variance method was performed, and the certainty of evidence was assessed using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) approach. RESULTS: We found 12 studies (n = 292 neonates) and were able to meta-analyze 7 studies that used erythromycin at a dose of 50 mg/kg body weight per day for 14 days. The clinical and microbiological cure were 96% (95% confidence interval [CI], 94%-100%) and 97% (95% CI, 95%-99%), respectively, and adverse gastrointestinal effects occurred in 14% (95% CI, 1%-28%) of the neonates. The microbiological cure in the study that assessed azithromycin at 20 mg/kg per day were 60% (95% CI, 27%-93%) when it was given in a single dose and 86% (95% CI, 61%-100%) when given in a 3-day course. Two studies reported compliance with treatments, and 1 study reported no pyloric stenosis events. Because of the risk of bias and the few neonates included across the studies, the certainty of evidence is low to very low. No studies assessed trimethoprim. CONCLUSIONS: Although evidence suggests that erythromycin at 50 mg/kg per day for 14 days results in higher numbers of cure than does azithromycin, compliance and risk of pyloric stenosis related to their use for other infections in neonates will factor into treatment recommendations. More data are needed to compare these treatments directly.


Assuntos
Antibacterianos/uso terapêutico , Infecções por Chlamydia/tratamento farmacológico , Conjuntivite Bacteriana/tratamento farmacológico , Antibacterianos/efeitos adversos , Azitromicina/efeitos adversos , Azitromicina/uso terapêutico , Viés , Chlamydia trachomatis , Esquema de Medicação , Eritromicina/efeitos adversos , Eritromicina/uso terapêutico , Feminino , Gastroenteropatias/induzido quimicamente , Humanos , Recém-Nascido , Masculino , Estenose Pilórica/induzido quimicamente , Fatores de Risco , Trimetoprima/efeitos adversos , Trimetoprima/uso terapêutico
17.
BMC Pediatr ; 16(1): 139, 2016 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-27544219

RESUMO

BACKGROUND: Interventions to improve neonatal resuscitation are considered a priority for reducing neonatal mortality. In addition to training programs for health caregivers, the availability of adequate equipment in all delivery settings is crucial. In this study, we assessed the availability of equipment for neonatal resuscitation in a large sample of delivery rooms in Vietnam, exploring regional differences. METHODS: In 2012, a structured questionnaire on 2011 neonatal resuscitation practice was sent to the heads of 187 health facilities, representing the three levels of hospital-based maternity services in eight administrative regions in Vietnam, allowing national and regional estimates to be calculated. RESULTS: Overall the response rate was an 85.7 % (160/187 hospitals). There was a limited availability of equipment considered as "essential" in the surveyed centres: stethoscopes (68.0 %; 95 % CI: 60.3-75.7), clock (50.3 %; 42.0-58.7), clothes (29.5 %; (22.0-36.9), head covering (12.3 %; 7.2-17.4). The percentage of centres equipped with polyethylene bags (2.2 %; 0.0-4.6), pulse oximeter (9.4 %; 5.2-13.6) and room air source (1.9 %; 0.1-3.6) was very low. CONCLUSION: Adequate equipment for neonatal resuscitation was not available in a considerable proportion of hospitals in Vietnam. This problem was more relevant in some regions. The assessment strategy used in this study could be useful for organizing the procurement and distribution of supplies and equipment in other low and/or middle resource settings.


Assuntos
Salas de Parto/estatística & dados numéricos , Países em Desenvolvimento/estatística & dados numéricos , Recursos em Saúde/provisão & distribuição , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Disparidades em Assistência à Saúde/estatística & dados numéricos , Terapia Intensiva Neonatal/estatística & dados numéricos , Ressuscitação/instrumentação , Pesquisas sobre Atenção à Saúde , Humanos , Recém-Nascido , Vietnã
18.
Acta Paediatr ; 104(6): e255-62, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25693428

RESUMO

AIM: Interventions that improve neonatal resuscitation are critical if we are to reduce perinatal mortality. We evaluated the consistency of resuscitation practices, and adherence to the international guidelines for neonatal resuscitation, in a large representative sample of hospitals in Vietnam. METHODS: A questionnaire was sent to 187 public central, provincial and district hospitals, representing the three levels of public hospital-based maternity services in Vietnam. RESULTS: The overall response rate was 85.7% (160/187 hospitals), and the response rate was 100%, 90.3% and 81.7% for central, provincial and district hospitals, respectively. There were 620 300 births in the surveyed hospitals during the year 2011, representing almost half of all inpatient births in Vietnam. Neonatal resuscitation was provided by obstetricians and, or, midwives at all levels. Half of the hospitals did not follow recommendations for delaying cord clamping. The majority of the hospitals did not have a wall thermometer in the delivery room (80.5%) and did not monitor neonatal temperature after birth (64.1%). A large proportion of hospitals (39.9%) used 100% oxygen to initiate resuscitation and only central hospitals avoided this practice. CONCLUSION: Our survey identified significant variations in resuscitation practices between central, provincial and district hospitals and limited adherence to international recommendations.


Assuntos
Salas de Parto/estatística & dados numéricos , Ressuscitação/estatística & dados numéricos , Hospitais de Distrito/estatística & dados numéricos , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Ressuscitação/métodos , Vietnã
19.
Bull World Health Organ ; 91(4): 254-61, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23599548

RESUMO

OBJECTIVE: To investigate changes that took place between 2006 and 2010 in the inequity gap for antenatal care attendance and delivery at health facilities among women in Viet Nam. METHODS: Demographic, socioeconomic and obstetric data for women aged 15-49 years were extracted from Viet Nam's Multiple Indicator Cluster Survey for 2006 (MICS3) and 2010-2011 (MICS4). Multivariate logistic regression was performed to determine if antenatal care attendance and place of delivery were significantly associated with maternal education, maternal ethnicity (Kinh/Hoa versus other), household wealth and place of residence (urban versus rural). These independent variables correspond to the analytical framework of the Commission on Social Determinants of Health. FINDINGS: Large discrepancies between urban and rural populations were found in both MICS3 and MICS4. Although antenatal care attendance and health facility delivery rates improved substantially between surveys (from 86.3 to 92.1% and from 76.2 to 89.7%, respectively), inequities increased, especially along ethnic lines. The risk of not giving birth in a health facility increased significantly among ethnic minority women living in rural areas. In 2006 this risk was nearly five times higher than among women of Kinh/Hoa (majority) ethnicity (odds ratio, OR: 4.67; 95% confidence interval, CI: 2.94-7.43); in 2010-2011 it had become nearly 20 times higher (OR: 18.8; 95% CI: 8.96-39.2). CONCLUSION: Inequity in maternal health care utilization has increased progressively in Viet Nam, primarily along ethnic lines, and vulnerable groups in the country are at risk of being left behind. Health-care decision-makers should target these groups through affirmative action and culturally sensitive interventions.


Assuntos
Disparidades em Assistência à Saúde/etnologia , Disparidades em Assistência à Saúde/estatística & dados numéricos , Serviços de Saúde Materna/estatística & dados numéricos , Características de Residência/estatística & dados numéricos , Adolescente , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Fatores Socioeconômicos , Vietnã , Adulto Jovem
20.
BMC Pediatr ; 13: 51, 2013 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-23570330

RESUMO

BACKGROUND: Infection causes neonatal mortality in both high and low income countries. While simple interventions to prevent neonatal infection are available, they are often poorly understood and implemented by clinicians. A basic understanding of healthcare providers' perceptions of infection control provides a platform for improving current practices. Our aim was to explore the views of healthcare providers in provincial hospitals in south and south central Vietnam to inform the design of programmes to improve neonatal infection prevention and control. METHODS: All fifty-four participants who attended a workshop on infection prevention and control were asked to complete an anonymous, written questionnaire identifying their priorities for improving neonatal infection prevention and control in provincial hospitals in south and south central Vietnam. RESULTS: Hand washing, exclusive breastfeeding and safe disposal of medical waste were nominated by most participants as priorities for preventing neonatal infections. Education through instructional posters and written guidelines, family contact, kangaroo-mother-care, limitation of invasive procedures and screening for maternal GBS infection were advocated by a smaller proportion of participants. CONCLUSIONS: The opinions of neonatal healthcare providers at the workshop accurately reflect some of the current international recommendations for infection prevention. However, other important recommendations were not commonly identified by participants and need to be reinforced. Our results will be used to design interventions to improve infection prevention in Vietnam, and may be relevant to other low-resource countries.


Assuntos
Atitude do Pessoal de Saúde , Países em Desenvolvimento , Cuidado do Lactente/métodos , Controle de Infecções/métodos , Adulto , Educação Médica Continuada , Educação Continuada em Enfermagem , Feminino , Hospitais Estaduais , Humanos , Cuidado do Lactente/normas , Recém-Nascido , Controle de Infecções/normas , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Inquéritos e Questionários , Centros de Atenção Terciária , Vietnã
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...