Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 60(4): 523-531, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35020246

RESUMO

OBJECTIVE: To compare longitudinal maternal hemodynamic changes throughout gestation between different groups stratified according to weight at presentation and assess the relative influence of height, weight at presentation and gestational weight gain on cardiac adaptation. METHODS: This was a prospective, longitudinal study assessing maternal hemodynamics using bioreactance technology at 11 + 0 to 13 + 6, 19 + 0 to 24 + 0, 30 + 0 to 34 + 0 and 35 + 0 to 37 + 0 weeks' gestation. Women were divided into three groups according to maternal weight at presentation at the first visit at 11 + 0 to 13 + 6 weeks: Group 1, < 60.0 kg (n = 421); Group 2, 60.0-79.7 kg (n = 904); Group 3, > 79.7 kg (n = 427). A multilevel linear mixed-effects model was used to compare the repeated measures of hemodynamic variables, correcting for demographics, medical and obstetric history, pregnancy complications, maternal weight and time of evaluation. The linear mixed-effects model was then repeated using maternal height, weight at presentation and gestational weight gain Z-scores, and the standardized coefficients were used to evaluate the relative impact of each of these demographic parameters on longitudinal changes of maternal hemodynamics. RESULTS: Compared with Group 1, women in Group 3 demonstrated higher cardiac output (CO), heart rate (HR) and mean arterial pressure (MAP) throughout pregnancy. Groups 2 and 3 had higher stroke volume (SV) than Group 1 at the first visit, but their SV plateaued between the first and second visits and demonstrated an earlier significant decrease from the second visit to the third visit when compared with Group 1. Compared with Groups 1 and 2, there was a higher prevalence of pre-eclampsia, gestational hypertension and gestational diabetes in Group 3. Maternal height was the most important contributor to CO, peripheral vascular resistance (PVR), SV and HR, while weight at presentation was the most important contributor to MAP. Gestational weight gain was the second most important characteristic influencing the longitudinal changes of PVR and SV. CONCLUSIONS: Women with greater weight at presentation have a pathological hemodynamic profile, with higher CO, HR and MAP compared to women with lower weight at presentation. Height is the main determinant of CO, SV, HR and PVR, weight is the main determinant of MAP, and gestational weight gain is the second most important determinant of SV and PVR. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Ganho de Peso na Gestação , Débito Cardíaco/fisiologia , Feminino , Idade Gestacional , Hemodinâmica/fisiologia , Humanos , Estudos Longitudinais , Gravidez , Estudos Prospectivos , Resistência Vascular/fisiologia
2.
Ultrasound Obstet Gynecol ; 58(2): 285-292, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33592675

RESUMO

OBJECTIVE: To compare longitudinal maternal hemodynamic changes throughout gestation between different age groups. METHODS: This was a prospective longitudinal study assessing maternal hemodynamics using a bioreactance technique at 11 + 0 to 13 + 6, 19 + 0 to 24 + 0, 30 + 0 to 34 + 0 and 35 + 0 to 37 + 0 weeks' gestation. Women were divided into four groups according to maternal age at the first visit at 11 + 0 to 13 + 6 weeks: Group 1, < 25.0 years; Group 2, 25.0-30.0 years; Group 3, 30.1-34.9 years; and Group 4, ≥ 35.0 years. A multilevel linear mixed-effects model was performed to compare the repeat measurements of hemodynamic variables, correcting for demographics, medical and obstetric history, pregnancy complications, maternal age and gestational-age window. RESULTS: The study population included 254 women in Group 1, 442 in Group 2, 618 in Group 3 and 475 in Group 4. Younger women (Group 1) had the highest cardiac output (CO) and lowest peripheral vascular resistance (PVR), and older women (Group 4) had the lowest CO and highest PVR throughout pregnancy. The higher CO seen in younger women was achieved through an increase in heart rate alone and not with a concomitant rise in stroke volume. Although the youngest age group demonstrated an apparently more favorable hemodynamic profile, it had the highest incidence of a small-for-gestational-age neonate. There was no significant difference between the groups in the incidence of pre-eclampsia. CONCLUSION: Age-specific differences in maternal hemodynamic adaptation do not explain the differences in the incidence of a small-for-gestational-age neonate between age groups. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Gravidez/fisiologia , Adaptação Fisiológica , Adulto , Feminino , Hemodinâmica , Humanos , Estudos Longitudinais , Idade Materna , Estudos Prospectivos , Adulto Jovem
3.
Anaesthesia ; 75(10): 1307-1313, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32469423

RESUMO

Maternal cardiac dysfunction is associated with pre-eclampsia, fetal growth restriction and haemodynamic instability during obstetric anaesthesia. There is growing interest in the use of non-invasive cardiac output monitoring to guide antihypertensive and fluid therapies in obstetrics. The aim of this study was to validate thoracic bioreactance using the NICOM® instrument against transthoracic echocardiography in pregnant women, and to assess the effects of maternal characteristics on the absolute difference of stroke volume, cardiac output and heart rate. We performed a prospective study involving women with singleton pregnancies in each trimester. We recruited 56 women who were between 11 and 14 weeks gestation, 57 between 20 and 23 weeks, and 53 between 35 and 37 weeks. Cardiac output was assessed repeatedly and simultaneously over 5 min in the left lateral position with NICOM and echocardiography. The performance of NICOM was assessed by calculating bias, 95% limits of agreement and mean percentage difference relative to echocardiography. Multivariate regression analysis evaluated the effect of maternal characteristics on the absolute difference between echocardiography and NICOM. The mean percentage difference of cardiac output measurements between the two methods was ±17%, with mean bias of -0.13 l.min-1 and limits of agreement of -1.1 to 0.84; stroke volume measurements had a mean percentage difference of ±15%, with a mean bias of -0.8 ml (-10.9 to 12.6); and heart rate measurements had a mean percentage difference of ±6%, with a mean bias of -2.4 beats.min-1 (-6.9 to 2.0). Similar results were found when the analyses were confined to each individual trimester. The absolute difference between NICOM and echocardiography was not affected by maternal age, weight, height, race, systolic or diastolic blood pressure. In conclusion, NICOM demonstrated good agreement with echocardiography, and can be used in pregnancy for the measurement of cardiac function.


Assuntos
Débito Cardíaco/fisiologia , Gravidez/fisiologia , Adulto , Ecocardiografia , Feminino , Idade Gestacional , Frequência Cardíaca , Humanos , Monitorização Fisiológica , Pré-Eclâmpsia , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico , Resistência Vascular
4.
BJOG ; 127(8): 1018-1025, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32133780

RESUMO

OBJECTIVE: To compare maternal haemodynamics in women at low and high risk for preterm pre-eclampsia (PE), and between those at high risk who are randomised to aspirin or placebo. DESIGN: Prospective, longitudinal observational study. SETTING: Maternity units in six UK hospitals. POPULATION: Women participating in the Aspirin for Prevention of Preterm Pre-eclampsia (ASPRE) trial. The population comprised three groups of women: low risk for preterm PE (n = 1362), high risk for preterm PE treated with aspirin (n = 208) and high risk for preterm PE on placebo (n = 220). METHODS: Women had four visits during pregnancy: 11-14, 19-24, 30-34, and 35-37 weeks' gestation. Blood pressure was measured with a device validated for pregnancy, and PE and maternal haemodynamics were assessed with a bioreactance monitor at each visit. A multilevel linear mixed-effects analysis was performed to examine longitudinal changes of maternal haemodynamic variables, controlling for demographic characteristics, past medical history and medication use. MAIN OUTCOME MEASURES: Longitudinal changes of cardiac output (CO), mean arterial pressure (MAP), and peripheral vascular resistance (PVR). RESULTS: The low-risk group demonstrated the expected changes with an increase in CO and reduction in MAP and PVR, with a quadratic change across gestation. In contrast, the high-risk groups had a declining CO, and higher MAP and PVR during pregnancy. The administration of aspirin did not appear to affect maternal haemodynamics. CONCLUSIONS: Women screened as high risk for preterm PE have a pathological cardiac adaptation to pregnancy and the prophylactic use of aspirin (150 mg oral daily from the first trimester) in this group may not alter this haemodynamic profile. TWEETABLE ABSTRACT: In women at high risk of pre-eclampsia, prophylactic use of aspirin may not alter the impaired maternal cardiac adaptation.


Assuntos
Aspirina/uso terapêutico , Débito Cardíaco/efeitos dos fármacos , Inibidores da Agregação Plaquetária/uso terapêutico , Pré-Eclâmpsia/prevenção & controle , Gravidez de Alto Risco/efeitos dos fármacos , Adulto , Pressão Arterial/efeitos dos fármacos , Pressão Arterial/fisiologia , Débito Cardíaco/fisiologia , Feminino , Idade Gestacional , Humanos , Estudos Longitudinais , Pré-Eclâmpsia/tratamento farmacológico , Gravidez , Gravidez de Alto Risco/fisiologia , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Resistência Vascular/efeitos dos fármacos , Resistência Vascular/fisiologia
5.
Ultrasound Obstet Gynecol ; 56(1): 37-43, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31692154

RESUMO

OBJECTIVE: To compare central hemodynamics between white, black and Asian women in pregnancy. METHODS: This was a prospective, longitudinal study of maternal central hemodynamics in white, black and Asian women with a singleton pregnancy, assessed using a bioreactance method at 11 + 0 to 13 + 6, 19 + 0 to 24 + 0, 30 + 0 to 34 + 0 and 35 + 0 to 37 + 0 weeks' gestation. At each visit, cardiac output (CO), stroke volume (SV), heart rate (HR), peripheral vascular resistance (PVR) and mean arterial pressure were recorded. Multilevel linear mixed-effects analysis was performed to compare the repeated measures of the cardiac variables between white, black and Asian women, controlling for maternal characteristics, medical history and medication use. RESULTS: The study population included 1165 white, 247 black and 116 Asian women. CO increased with gestational age to a peak at 32 weeks and then decreased; the highest CO was observed in white women and the lowest in Asian women. SV initially increased after the first visit but subsequently declined with gestational age in white women, decreased with gestational age in black women and remained static in Asian women. In all three study groups, HR increased with gestational age until 32 weeks and then remained constant; HR was highest in black women and lowest in white women. PVR showed a reversed pattern to that of CO; the highest values were in Asian women and the lowest in white women. The least favorable hemodynamic profile, which was observed in black and Asian women, was reflected in higher rates of a small-for-gestational-age infant. CONCLUSIONS: There are race-specific differences in maternal cardiac adaptation to pregnancy. White women have the most favorable cardiac adaptation by increasing SV and HR, achieving the highest CO and lowest PVR. In contrast, black and Asian women have lower CO and higher PVR than do white women, with CO increasing through a rise in HR due to declining or static SV. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Hemodinâmica , Gravidez/fisiologia , Adulto , Etnicidade , Feminino , Idade Gestacional , Humanos , Estudos Longitudinais , Pré-Eclâmpsia/diagnóstico , Pré-Eclâmpsia/etnologia , Pré-Eclâmpsia/fisiopatologia , Gravidez/etnologia , Estudos Prospectivos , Valores de Referência
6.
Ultrasound Obstet Gynecol ; 54(1): 51-57, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30246326

RESUMO

OBJECTIVE: To compare maternal hemodynamics and perinatal outcome, in pregnancies that do not develop pre-eclampsia (PE) or deliver a small-for-gestational-age (SGA) neonate, between those identified at 11-13 weeks' gestation as being screen positive or negative for preterm PE, by a combination of maternal factors, mean arterial pressure, uterine artery pulsatility index, serum placental growth factor and pregnancy associated plasma protein-A. METHODS: This was a prospective longitudinal cohort study of maternal cardiovascular function, assessed using a bioreactance method, in women undergoing first-trimester screening for PE. Maternal hemodynamics and perinatal outcome were compared between screen-positive and screen-negative women who did not have a medical comorbidity, did not develop PE or pregnancy-induced hypertension and delivered at term a live neonate with birth weight between the 5th and 95th percentiles. A multilevel linear mixed-effects model was used to compare the repeated measures of cardiac variables, controlling for maternal characteristics. RESULTS: The screen-negative group (n = 926) had normal cardiac function changes across gestation, whereas the screen-positive group (n = 170) demonstrated static or reduced cardiac output and stroke volume and higher mean arterial pressure and peripheral vascular resistance with advancing gestation. In the screen-positive group, compared with screen-negative women, birth-weight Z-score was shifted toward lower values, with prevalence of delivery of a neonate below the 35th , 30th or 25th percentile being about 70% higher, and the rate of operative delivery for fetal distress in labor also being higher. CONCLUSION: Women who were screen positive for impaired placentation, even though they did not develop PE or deliver a SGA neonate, had pathological cardiac adaptation in pregnancy and increased risk of adverse perinatal outcome. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Débito Cardíaco/fisiologia , Retardo do Crescimento Fetal/diagnóstico , Hemodinâmica/fisiologia , Pré-Eclâmpsia/diagnóstico , Adulto , Pressão Arterial/fisiologia , Peso ao Nascer/fisiologia , Feminino , Sofrimento Fetal/cirurgia , Retardo do Crescimento Fetal/fisiopatologia , Humanos , Hipertensão Induzida pela Gravidez/fisiopatologia , Recém-Nascido , Estudos Longitudinais , Mortalidade Perinatal/tendências , Fator de Crescimento Placentário/metabolismo , Pré-Eclâmpsia/fisiopatologia , Gravidez , Resultado da Gravidez , Primeiro Trimestre da Gravidez/metabolismo , Primeiro Trimestre da Gravidez/fisiologia , Proteína Plasmática A Associada à Gravidez/metabolismo , Estudos Prospectivos , Fluxo Pulsátil/fisiologia , Artéria Uterina/diagnóstico por imagem , Resistência Vascular/fisiologia
7.
Ultrasound Obstet Gynecol ; 52(4): 507-514, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29607557

RESUMO

OBJECTIVES: To assess whether, in a cohort of patients with a small-for-gestational-age (SGA) fetus with estimated fetal weight ≤ 10th percentile, maternal hemodynamics, fetal biometry and Doppler indices at presentation can predict the subsequent development of an abnormal fetal Doppler index or delivery of a baby with birth weight < 3rd percentile. METHODS: This was a prospective observational cohort study conducted at a specialist clinic for the management of pregnancies with a SGA fetus at King's College Hospital, London, UK. The study population comprised 86 singleton pregnancies with a SGA fetus, presenting at a median gestational age of 32 (range, 26-35) weeks. We measured maternal cardiac function using a non-invasive transthoracic bioreactance monitor, as well as mean arterial pressure, fetal biometry, and umbilical artery (UA), fetal middle cerebral artery (MCA) and uterine artery (UtA) pulsatility indices (PI), and the deepest vertical pool of amniotic fluid. Z-scores of these variables were calculated based on reported reference ranges and the values were compared between pregnancies with evidence of an abnormal fetal Doppler index at presentation (Group 1), those that had developed an abnormal Doppler index at a subsequent visit (Group 2) and those that did not develop an abnormal Doppler index throughout pregnancy (Group 3). Abnormal fetal Doppler was defined as UA-PI > 95th percentile and/or MCA-PI < 5th percentile. Differences in measured variables at presentation were also compared between pregnancies delivering a baby with birth weight < 3rd percentile and those delivering a baby with birth weight ≥ 3rd percentile. Multivariate logistic regression analysis was used to determine significant predictors of birth weight < 3rd percentile and evolution from normal to abnormal fetal Doppler. RESULTS: In the study population, 14 (16%) cases were in Group 1, 19 (22%) in Group 2 and 53 (62%) in Group 3. Birth weight was < 3rd percentile in 39 (45%) cases and ≥ 3rd percentile in 47 (55%). There was decreased cardiac output and stroke volume and increased peripheral vascular resistance compared with a normal population, and the deviations from normal were most marked in Group 1. Pregnancies with birth weight < 3rd percentile, compared with those with birth weight ≥ 3rd percentile, had greater deviations from normal in fetal biometry, maternal cardiac output, stroke volume, heart rate, peripheral vascular resistance and UtA-PI. Multivariate logistic regression analysis demonstrated that, in the prediction of birth weight < 3rd percentile, maternal hemodynamic profile provided significant improvement to the prediction provided by maternal demographics, fetal biometry, UtA-PI, UA-PI and MCA-PI (difference between areas under receiver-operating characteristics curves, 0.18 (95% CI, 0.06-0.29); P = 0.002). In contrast, there was no significant independent contribution from maternal hemodynamics in the prediction of the subsequent development of abnormal fetal Doppler. CONCLUSIONS: In pregnancies with a SGA fetus, there is decreased maternal cardiac output and stroke volume and increased peripheral vascular resistance, and the deviations from normal are most marked in cases of redistribution in the fetal circulation and reduced amniotic fluid volume. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Retardo do Crescimento Fetal/fisiopatologia , Feto/irrigação sanguínea , Hemodinâmica/fisiologia , Ultrassonografia Doppler em Cores , Artérias Umbilicais/fisiopatologia , Artéria Uterina/fisiopatologia , Adulto , Pressão Arterial/fisiologia , Biometria , Velocidade do Fluxo Sanguíneo , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Peso Fetal , Seguimentos , Idade Gestacional , Humanos , Recém-Nascido Pequeno para a Idade Gestacional , Gravidez , Cuidado Pré-Natal , Estudos Prospectivos , Valores de Referência , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/embriologia , Artéria Uterina/diagnóstico por imagem , Artéria Uterina/embriologia
8.
Ultrasound Obstet Gynecol ; 51(3): 368-374, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28294444

RESUMO

OBJECTIVES: To evaluate the effect of posture change from the supine to the sitting position and before and after passive leg raising on maternal functional hemodynamics in pregnant women at 35-37 weeks' gestation, and to compare the changes in pregnancies that subsequently developed pre-eclampsia (PE) or gestational hypertension (GH) with those that remained normotensive. METHODS: In 2764 singleton pregnancies at 35-37 weeks' gestation, maternal cardiovascular parameters were measured using an automated non-invasive cardiac monitor. The hemodynamic response to a change from the supine to the sitting position and before and after passive leg raising in the left lateral position was examined and compared between women who subsequently developed PE or GH and those who remained normotensive. RESULTS: In normotensive singleton pregnancies at 35-37 weeks' gestation, both change from the supine to the sitting position and passive leg raising were associated with an increase in cardiac index and stroke volume index and a decrease in total peripheral resistance index; there was a small increase in mean arterial pressure with both postural changes and a slight decrease in heart rate with passive leg raising. In pregnancies that subsequently developed PE or GH, compared with normotensive pregnancies, cardiac index and stroke volume index were lower and total peripheral resistance index was higher. In general, change from the supine to the sitting position and passive leg raising were associated with similar but less marked changes in cardiovascular parameters as in normotensive pregnancies. CONCLUSIONS: Paradoxically, in late third-trimester normal pregnancy, both change from the supine to a sitting position and passive leg raising may result in an increase in preload with a consequent increase in cardiac and stroke volume indices and a decrease in total peripheral resistance index. In pregnancies that develop PE or GH, the effects of postural change on cardiovascular parameters are similar but less marked than in normotensive pregnancies. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Pressão Arterial/fisiologia , Cardiografia de Impedância , Hemodinâmica/fisiologia , Hipertensão Induzida pela Gravidez/fisiopatologia , Postura/fisiologia , Gestantes , Volume Sistólico/fisiologia , Adulto , Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Hipertensão Induzida pela Gravidez/diagnóstico por imagem , Pré-Eclâmpsia/fisiopatologia , Valor Preditivo dos Testes , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Processamento de Sinais Assistido por Computador
9.
Ultrasound Obstet Gynecol ; 49(1): 39-45, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27671837

RESUMO

OBJECTIVE: To examine the possible effects of maternal characteristics and obstetric and medical history on maternal cardiovascular parameters at 35-37 weeks' gestation. METHODS: In 3013 singleton pregnancies at 35-37 weeks, maternal characteristics and medical history were recorded; uterine artery pulsatility index, mean arterial pressure (MAP) and maternal cardiovascular parameters were measured. Multivariable regression analysis was used to determine significant predictors of the cardiovascular parameters among gestational age (GA), maternal characteristics and medical history. RESULTS: Multivariable regression analysis demonstrated that significant independent prediction of log10 cardiac output and log10 cardiac power was provided by GA, maternal age, weight, weight gain from the first trimester, height, racial origin, smoking, assisted conception and previous neonatal birth-weight Z-score in parous women. For log10 total peripheral resistance, significant prediction was provided by GA, maternal age, height, racial origin, chronic hypertension, diabetes mellitus, assisted conception, previous neonatal birth-weight Z-score and prior pre-eclampsia (PE) in parous women. For log10 stroke volume, significant prediction was provided by maternal age, height, racial origin, smoking, chronic hypertension and diabetes mellitus. For heart rate, significant prediction was provided by GA, weight, weight gain, height, racial origin, chronic hypertension, previous neonatal birth-weight Z-score and prior PE in parous women. For log10 MAP, significant prediction was provided by maternal weight, racial origin, family history of PE, chronic hypertension and diabetes mellitus. For log10 thoracic fluid capacity, significant prediction was provided by GA, maternal age, weight, height, racial origin and systemic lupus erythematosus or antiphospholipid syndrome. For log10 ventricular ejection time, significant prediction was provided by GA, weight, height and racial origin. CONCLUSION: Maternal cardiovascular parameters are affected by maternal characteristics and medical and obstetric history, and they should therefore be converted into multiples of the normal median adjusted for significant independent predictors before their inclusion in combined screening for PE. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Débito Cardíaco/fisiologia , Frequência Cardíaca/fisiologia , Adulto , Feminino , Hemodinâmica , Humanos , Idade Materna , Valor Preditivo dos Testes , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Análise de Regressão , Medição de Risco , Volume Sistólico
10.
Ultrasound Obstet Gynecol ; 49(1): 67-72, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27706864

RESUMO

OBJECTIVE: To evaluate the relationship between maternal cardiovascular parameters and neonatal birth weight and examine the potential value of these parameters in improving the prediction of small-for-gestational-age (SGA) and large-for-gestational-age (LGA) neonates provided by maternal characteristics and medical history. METHODS: In 2835 singleton pregnancies maternal characteristics and medical history were recorded and maternal cardiovascular parameters were measured. The observed measurements of cardiovascular parameters were expressed as multiples of the normal median (MoM) values after adjustment for those characteristics found to provide a substantial contribution to their measurement. Regression analysis was used to determine the significance of association between the normalized values of the cardiovascular parameters with birth-weight Z-score. Multivariable logistic regression analysis was then used to determine if the maternal factors, fetal biometry and maternal cardiovascular parameters had a significant contribution to predicting SGA and LGA neonates. The performance of screening was determined by the area under receiver-operating characteristics curves (AUC). RESULTS: In the study population there were significant positive associations between maternal cardiac output and heart rate with neonatal birth-weight Z-score, and significant negative associations between total peripheral resistance and mean arterial pressure (MAP) with neonatal birth-weight Z-score. In pregnancies delivering SGA neonates (n = 249 (8.8%)), cardiac output and heart rate were lower and total peripheral resistance and MAP were higher, whereas in pregnancies delivering LGA neonates (n = 292 (10.3%)) cardiac output and heart rate were higher and total peripheral resistance and MAP were lower. The performance of screening for delivery of SGA neonates achieved by maternal characteristics and fetal biometry was not improved by the measurement of maternal cardiovascular parameters. There was a small but significant improvement in the performance of screening for delivery of LGA neonates by maternal factors and fetal biometry with the addition of maternal heart rate (comparison of AUC, P = 0.0095). CONCLUSIONS: There are significant associations between maternal cardiac output, heart rate, total peripheral resistance and MAP and neonatal birth-weight Z-score; such findings reflect the close relationship between maternal cardiac function and fetal demands. However, assessment of these parameters at 35-37 weeks' gestation is unlikely to improve substantially the performance of screening for SGA or LGA neonates provided by a combination of maternal factors and fetal biometry. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Débito Cardíaco/fisiologia , Retardo do Crescimento Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Peso ao Nascer , Feminino , Peso Fetal , Idade Gestacional , Frequência Cardíaca , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Gravidez , Resultado da Gravidez , Terceiro Trimestre da Gravidez , Medição de Risco
11.
Ultrasound Obstet Gynecol ; 49(1): 61-66, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27619066

RESUMO

OBJECTIVE: To investigate the potential value of combining maternal factors with multiples of the normal median values of maternal cardiovascular parameters at 35-37 weeks' gestation in the prediction of pre-eclampsia (PE) and gestational hypertension (GH). METHODS: In 2764 singleton pregnancies maternal characteristics and medical history were recorded; uterine artery pulsatility index (UtA-PI), mean arterial pressure (MAP) and maternal cardiovascular parameters were measured. Multivariable logistic regression analysis was then used to determine if the maternal factors and maternal cardiovascular parameters made a significant contribution to predicting PE and GH. The performance of screening was determined by the area under receiver-operating characteristics curves. RESULTS: In pregnancies that subsequently delivered with PE or GH, total peripheral resistance and MAP were higher and maternal cardiac output was lower, mainly owing to a decrease in heart rate in PE and a decrease in stroke volume in GH. The increases in total peripheral resistance and MAP were inversely related to gestational age at delivery. The performance of screening for PE and GH achieved by maternal characteristics and medical history was improved by the inclusion of MAP, but not by UtA-PI or maternal cardiovascular parameters. CONCLUSIONS: In women developing term PE total peripheral resistance and MAP are increased and maternal cardiac output is reduced. However, assessment of maternal cardiac function at 35-37 weeks' gestation is unlikely to improve the performance of screening for PE provided by maternal factors and MAP alone. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Hipertensão Induzida pela Gravidez/diagnóstico por imagem , Pré-Eclâmpsia/diagnóstico por imagem , Área Sob a Curva , Pressão Arterial , Peso ao Nascer , Feminino , Frequência Cardíaca , Hemodinâmica , Humanos , Hipertensão Induzida pela Gravidez/fisiopatologia , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Pré-Eclâmpsia/fisiopatologia , Valor Preditivo dos Testes , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...