Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Work Expo Health ; 65(9): 1085-1095, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34228094

RESUMO

The aim of the study was to find out good practices for effective air distribution inside a complex shaped asbestos enclosure and for control of pressure differences between the enclosure and the surroundings. In addition, sufficient pressure difference for asbestos containment was tested. The effect of air distribution was studied in laboratory conditions by constructing an L-shaped asbestos enclosure and connecting it to a negative pressure unit. The efficiency of six different ventilation configurations was compared using a tracer decay method and the local air change indexes as the performance indicator. The sufficient negative pressure for containment was assessed by simulating person traffic to and from the enclosure and recording the pressure difference continuously. The effect of a pressure controller unit in maintaining the target pressure difference was also tested by simulating filter loadings of the negative pressure unit causing changes in the air flow rate. The results showed that high nominal air change rates alone do not guarantee good air distribution. Effective air distribution within an asbestos enclosure can be arranged by locating additional air supply openings far away from the air exhaustion point, using recirculation air with a pressure controller, or extending the exhaust location to the poorly ventilated areas. A pressure difference of at least -10 Pa is recommended to ensure a sufficient margin of safety in practical situations.


Assuntos
Amianto , Exposição Ocupacional , Humanos , Laboratórios , Ventilação
2.
Ann Work Expo Health ; 63(4): 468-479, 2019 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-30877765

RESUMO

OBJECTIVE: In real-world applications, implementation of an enclosure and negative pressurization is not always adequate to prevent the dispersion of dust from renovation sites. This study aimed to quantify the effect of local exhaust ventilation (LEV) in controlling the dust concentration within an enclosed renovation site to reduce the dust dispersion into adjacent areas. METHODS: The concentrations of inhalable and respirable dust were measured in 16 cases during renovation projects. Filter samples and time-resolved dust concentration data were collected simultaneously from the renovation site and adjacent areas to assess the efficacy of LEV in limiting the dust dispersion. RESULTS: The dispersion of dust outside of the enclosed renovation sites was limited significantly with using LEV. The estimated dust removal efficiency of LEV was 79% for inhalable dust concentration in the renovation site and 62% in the adjacent area. The use of LEV reduced the concentration of respirable dust by 33‒90% in the adjacent area and 80-87% within the renovation site. CONCLUSIONS: Using LEV was found to play a substantial role in dust containment, particularly when the enclosure failed to maintain the negative pressure. The study provides data-driven recommendations that are of practical importance as they promote healthier workplaces and policy improvements. In conclusion, dust dispersion into adjacent areas is prevented with an airtight enclosure (including airlocks) and continuous negative pressure. Dust containment was also obtained by having target dust concentration at the enclosed renovation site to below 4 mg m-3 for inhalable dust and below 1 mg m-3 for respirable dust, even though the enclosures not being continuously under negative pressure. The suggested target concentrations are achievable by using on-tool LEV during the most dust-producing tasks.


Assuntos
Poluentes Ocupacionais do Ar/análise , Materiais de Construção , Poeira/prevenção & controle , Exposição por Inalação/prevenção & controle , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/prevenção & controle , Ventilação/métodos , Poeira/análise , Humanos , Exposição por Inalação/análise , Exposição Ocupacional/análise
3.
Artigo em Inglês | MEDLINE | ID: mdl-29751545

RESUMO

To reduce the incidence of occupational diseases related to exposure to respirable silica at work, the main industries in the EU associated with respirable silica agreed on measures to improve working conditions through the application of good practices. These practices were included in “The Agreement on Workers Health Protection through the Good Handling and Use of Crystalline Silica and Products Containing it” (NEPSI agreement), signed in April 2006. In Finland, we have previously seen a decline in exposure to respirable quartz in relevant industries upon the treaty coming into effect, during the years 2006⁻2013. The present paper examines trends in exposure to respirable crystalline silica in Finland from 2006 to the end of 2017. In addition, we looked at changes in the number of exposed workers and the prevalence of silicosis and lung cancer associated with the exposure during the same period. The aim was to find out whether the decline in exposure previously recorded had continued, and whether this, in addition to the previously reported descent in exposure, was reflected in the amount and prevalence of occupational diseases associated with inhaling respirable quartz. In the present study, during the period 2013 to 2017 no further improvements were observed. The exposure remained at an average level of 20⁻50% of the current OEL8h. This is not necessarily sufficient to eliminate silicosis, lung cancer or other health effects associated with exposure to respirable silica in affected workplaces. To bring about further improvements in exposure, we suggest the present OEL8h in Finland (0.05 mg/m³) and particularly in the many EU countries with an OEL8h of 0.1 mg/m³ be lowered to 0.020⁻0.025 mg/m³. Secondly, branches outside of the NEPSI treaty where the number of exposed workers is increasing in Finland and possibly in some other EU countries as well, namely building and refinery industries, would be advised to sign the treaty. In addition, as a result of signing, good practices should be developed for work tasks where exposure to respirable silica is of concern in these industries.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poeira/análise , Exposição por Inalação/análise , Exposição Ocupacional/análise , Quartzo/análise , Finlândia/epidemiologia , Humanos , Indústrias , Estudos Longitudinais , Silicose/epidemiologia , Local de Trabalho
4.
Ann Work Expo Health ; 61(6): 681-691, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575167

RESUMO

OBJECTIVES: The aim of this study was to assess the implementation of partitioning and the negative pressure method in limiting the dispersion of dust to areas adjacent to renovation sites. METHODS: The pressure difference between the worksites and adjacent areas and PM10 concentrations in the both zones were measured in 12 renovation sites, and the factors affecting the prevention of dispersion of dust were assessed. RESULTS: Poor implementation of partitioning and negative pressurization found in half of the renovation sites lead difficulties in achieving a proper negative pressure, causing dispersion of dust into adjacent areas. Main problems related to flimsy partitioning walls and poor air tightness of the enclosure. Dust concentrations in adjacent areas were substantially lower when natural ventilation in the renovation site was rejected and partitioning walls and their junctions to existing structures were sealed. In case of leaky enclosures, despite the high air exchange rates, a definite negative pressure could not be maintained. Instead, negative pressure minimum of -5 Pa was found to be sufficient for limiting the dispersion of dust from renovation sites. CONCLUSIONS: Improvement on implementation of dust controls is required through revising the guidance documents, education, and efficient supervision. This study revealed that the current Finnish practice to implement the negative pressurization based on the air exchange rate achieved with the portable exhaust fans alone is not reasonable to assure adequate dust containment. Continuous negative pressure minimum of -5 Pa is suggested, and it should be monitored with alarm devices throughout the renovation processes.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Indústria da Construção , Poeira/análise , Arquitetura de Instituições de Saúde/normas , Exposição Ocupacional/prevenção & controle , Poluição do Ar em Ambientes Fechados/análise , Pressão do Ar , Finlândia , Humanos , Material Particulado/análise
5.
J Occup Environ Med ; 57(2): 124-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25654513

RESUMO

OBJECTIVE: To assess whether cumulative dust exposure in foundry work is associated with airway inflammation measured by the analysis of fractionated exhaled nitric oxide (NO) concentration, or by inflammatory markers in exhaled breath condensate or serum. METHODS: We examined 476 dust-exposed and nonexposed foundry workers, and assessed the individual cumulative exposure to dusts and respirable quartz. Bronchial and alveolar NO production and inflammatory markers in exhaled breath condensate and in serum samples were also analyzed. RESULTS: After adjusting for pack-years of smoking, increased levels of alveolar NO, serum C-reactive protein, and interleukin-8 were associated with a higher level of cumulative exposure to dust. The referents had higher serum myeloperoxidase levels, bronchial NO output, and 8-isoprostane levels in exhaled breath condensate than in the dust-exposed groups. CONCLUSIONS: Dust exposure in foundry work may induce both systemic and alveolar inflammation.


Assuntos
Bronquiolite/metabolismo , Proteína C-Reativa/metabolismo , Interleucina-8/sangue , Doenças Pulmonares Intersticiais/metabolismo , Metalurgia , Óxido Nítrico/metabolismo , Exposição Ocupacional/efeitos adversos , Adulto , Biomarcadores/análise , Testes Respiratórios , Bronquiolite/etiologia , Estudos Transversais , Poeira/análise , Humanos , Doenças Pulmonares Intersticiais/etiologia , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/análise
6.
Ann Occup Hyg ; 58(7): 806-17, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24914034

RESUMO

To protect the health of those occupationally exposed to respirable crystalline silica, the main industries in European Union associated with exposure to respirable silica, agreed on appropriate measures for the improvement of working conditions through the application of good practices, as part of 'The Agreement on Workers Health Protection through the Good Handling and Use of Crystalline Silica and Products Containing it' (NEPSI agreement), signed in April 2006. The present paper examines trends in exposure to respirable crystalline silica in Finland prior to and following the implementation of the NEPSI agreement and includes a working example of the NEPSI approach in the concrete industry. Data derived from workplace exposure assessments during the years 1994-2013 are presented, including 2556 air samples collected mostly indoors, from either the breathing zone of workers or from stationary points usually at a height of 1.5 m above the floor, with the aim to estimate average exposure of workers to respiratory crystalline silica during an 8-h working day. The aim was, to find out how effective this unique approach has been in the management of one of the major occupational hazards in the concerned industries. Application of good practices as described by the NEPSI agreement coincides with a strong decline in the exposure to respirable crystalline silica in Finnish workplaces, as represented by the clientele of Finnish Institute of Occupational Health. During the years followed in the present study, we see a >10-fold decrease in the average and median exposures to respirable silica. Prior to the implementation of the NEPSI agreement, >50% of the workplace measurements yielded results above the OEL8 h (0.2mg m(-3)). As of present (2013), circa 10% of the measurements are above of or identical to the OEL8 h (0.05mg m(-3)).


Assuntos
Exposição por Inalação/análise , Exposição Ocupacional/prevenção & controle , Dióxido de Silício/análise , Poeira/análise , Finlândia , Humanos , Exposição por Inalação/efeitos adversos , Exposição por Inalação/prevenção & controle , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Local de Trabalho
7.
Ann Occup Hyg ; 55(6): 658-65, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21742626

RESUMO

Waste electrical and electronic equipment (WEEE) contains various hazardous substances such as flame retardants (FRs). Inhalation exposures to many FRs simultaneously among WEEE recycling site workers have been little studied previously. The breathing zone airborne concentrations of five brominated FR compounds tetrabromobisphenol-A (TBBP-A), decabromodiphenylethane (DBDPE), hexabromocyclododecane, 1,2-bis(2,4,6-tribromophenoxy)ethane, hexabromobenzene, and one chlorinated FR (Dechlorane Plus®) were measured at four electronics recycling sites in two consecutive years. In addition, concentrations of polybrominated diphenyl ethers (PBDEs) and polybrominated biphenyls were measured. The three most abundant FRs in personal air samples were PBDEs (comprising mostly of deca-BDE), TBBP-A, and DBDPE, with mean concentrations ranging from 21 to 2320 ng m(-)(3), from 8.7 to 430 ng m(-3), and from 3.5 to 360 ng m(-3), respectively. At two of the sites, the emission control actions (such as improvements in ventilation and its maintenance and changes in cleaning habits) proved successful, the mean levels of FRs in personal samples being 10-68 and 14-79% of those from the previous year or alternatively below the limit of quantification. At the two remaining sites, the reductions in FR exposures were less consistent. The concentrations reported may pose a health hazard to the workers, although evaluation of the association between FR exposure and adverse health effects is hampered by lacking occupational exposure limits. Therefore, the exposures should be minimized by adequate control measures and maintaining good occupational hygiene practice.


Assuntos
Poluentes Ocupacionais do Ar/análise , Resíduo Eletrônico/estatística & dados numéricos , Retardadores de Chama/análise , Substâncias Perigosas/análise , Exposição Ocupacional/estatística & dados numéricos , Gerenciamento de Resíduos/métodos , Equipamentos e Provisões Elétricas , Monitoramento Ambiental , União Europeia , Finlândia , Éteres Difenil Halogenados/análise , Humanos , Hidrocarbonetos Clorados/análise , Exposição por Inalação/análise , Exposição por Inalação/prevenção & controle , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Compostos Policíclicos/análise , Reciclagem/legislação & jurisprudência , Reciclagem/métodos , Dispositivos de Proteção Respiratória , Ventilação , Gerenciamento de Resíduos/legislação & jurisprudência , Local de Trabalho/normas
8.
J Occup Environ Hyg ; 7(1): 1-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19904652

RESUMO

Concurrent samples were collected with Andersen and IOM foam samplers to determine whether if the IOM foam sampler can be applied to collect culturable microorganisms. Two different kinds of aerosols were studied: peat dust in a power plant and mist from coolant fluid aerosolized during grinding of blades and rollers in a paper mill. In the power plant, the concentrations of fungi were 2-3 times higher in the IOM samples than in the Andersen samples. However, more fungal genera were identified in the latter case. The methods yielded similar concentrations of bacteria and actinobacteria in the power plant. On the other hand, the performance of the IOM foam sampler was very poor in the paper mill, where stress-sensitive gram-negative bacteria dominated; low concentration of bacteria was detected in only one IOM sample even though the concentration of bacteria often exceeded even the upper detection limit in the Andersen impactor samples. It could be concluded that the IOM foam sampler performs quite well for collecting inhalable fungi and actinobacteria. However, the Andersen sampler provides better information on fungal genera and concentrations of gram-negative bacteria. Personal sampling with the IOM foam sampler provided an important benefit in the power plant, where the concentration ratio of personal to stationary samples was much higher for bacteria than for inhalable or respirable dust.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Desenho de Equipamento , Manejo de Espécimes/instrumentação , Actinobacteria/isolamento & purificação , Contagem de Colônia Microbiana , Fungos/isolamento & purificação , Humanos , Tamanho da Partícula , Centrais Elétricas
9.
J Occup Environ Hyg ; 5(1): 28-35, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18041642

RESUMO

The performance of four sampling devices for inhalable dust and three devices for respirable dust was tested with different kinds of dusts in the laboratory and in the field. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM sampler provided with the porous plastic foam media was used as the reference method for respirable dust. The other tested instruments were the Button sampler, the optical Grimm aerosol monitor, and the Dekati two-stage cascade impactor with cutoff sizes of 10 and 4 mu m. The study confirmed the applicability of the IOM and Button samplers. The new foam product followed the respirable criteria well. However, the foam sampler was unstable for measuring inhalable dust, probably due to its moisture absorption. In addition, high dust loads should be avoided with the foam sampler due to increase in filtering efficiency. The concentrations of inhalable dust measured with the Button sampler, the Grimm monitor, and the impactor sampler were usually close to those measured with the reference sampler. On the other hand, impactor sampling yielded higher respirable dust concentrations than the reference method in the field, which may have been caused by particle bounce; high dust loads should be avoided while using the impactor. The results also showed that the Grimm monitor enables real-time dust concentration determinations that are accurate enough for routine monitoring of occupational exposure and for testing efficiency of control measures in workplaces.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poeira/análise , Monitoramento Ambiental/instrumentação , Exposição por Inalação/análise , Laboratórios , Metais/análise , Minerais/análise , Exposição Ocupacional/análise , Solo/análise
10.
Ann Occup Hyg ; 51(6): 509-16, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17607019

RESUMO

Refractory ceramic fibres (RCF) are used in thermal isolation in the metal industry where high temperatures are regularly employed. Asbestos materials were earlier commonly used for these purposes. In this work, two Finnish steel plants, three foundries and a repair shop were studied for the ceramic fibre exposure of their workers under normal production and during the replacement of oven insulation. Personal and stationary sampling was used together with a novel nasal lavage sampling for the evaluation of personal exposure. Fibres were counted with optical and electron microscopy and they were identified using an energy-dispersive X-ray analyser. Ceramic fibres were found in most production phases [range <0.01-0.29 fibres per cubic centimetre (f cm(-3))]. Considerably higher fibre counts were obtained during the maintenance work (range <0.01-14.2 f cm(-3)). Nasal sampling was found to correlate with the airborne fibre concentrations at the group level. The mean fibre concentrations varied from 34 to 6680 f ml(-1) of lavage liquid. Use of personal respiratory protectors diminished the exposure on the average as analysed in the lavage specimens, but the effect of respirator use did not appear clearly in the results. Because of the heat conditions, the workers used the respirators for a strict minimum period. A considerable exposure to RCF occurs in the studied plants. Its risk should be evaluated and managed more closely in view that the material is carcinogenic. Use of personal respiratory protectors should be encouraged. Their effective use could be verified by the nasal sampling for fibres after the work shift.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Cerâmica/toxicidade , Metalurgia , Exposição Ocupacional/efeitos adversos , Poluentes Ocupacionais do Ar/análise , Cerâmica/análise , Poeira/análise , Finlândia , Humanos , Exposição por Inalação/efeitos adversos , Exposição por Inalação/análise , Microscopia Eletrônica de Varredura/métodos , Fibras Minerais/análise , Fibras Minerais/toxicidade , Líquido da Lavagem Nasal/química , Exposição Ocupacional/análise , Aço
11.
Environ Health Perspect ; 114(9): 1409-13, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16966097

RESUMO

BACKGROUND: Polyvinyl chloride (PVC) materials have been linked to asthma in several epidemiologic studies, but the possible causal factors remain unknown. PARTICIPANTS: We challenged 10 subjects experimentally to degraded PVC products under controlled conditions. All of the subjects had previously experienced respiratory symptoms suspected to be caused by this kind of exposure in their work place. Five subjects had doctor-diagnosed asthma. METHODS: The subjects were exposed to degraded PVC material in an exposure chamber ; a challenge with ceramic tile was used as the control test. We followed exhaled nitric oxide, nasal NO, lung functions, cytokines [tumor necrosis factor-alpha (TNF-alpha) , interleukin-4 (IL-4) , IL-6, and IL-12] and NO in nasal lavage fluid (NAL) during and after the exposures. We also measured 2-ethylhexanol in exhaled breath samples and NAL. RESULTS: On the morning after the PVC exposure, subjects reported respiratory tract symptoms significantly more often than they did after the control test (50% vs. 0%, respectively ; p = 0.029 ; n = 10) . We did not detect any changes in lung functions or levels of exhaled NO, nasal NO, or NO in NAL after PVC challenge compared with the control test. Cytokine levels increased after both exposures, with no statistically significant difference between situations. All of the exhaled breath samples collected during the PVC exposure contained 2-ethylhexanol. CONCLUSIONS: PVC flooring challenge can evoke respiratory tract symptoms in exposed subjects. Our results do not support the hypothesis that PVC materials themselves evoke immediate asthmatic reactions. The chamber test used is well suited to this type of exposure study.


Assuntos
Asma/induzido quimicamente , Monitoramento Ambiental , Pulmão/efeitos dos fármacos , Doenças Profissionais/induzido quimicamente , Cloreto de Polivinila/toxicidade , Adulto , Asma/diagnóstico , Asma/epidemiologia , Testes Respiratórios , Citocinas/análise , Citocinas/metabolismo , Monitoramento Epidemiológico , Hexanóis/toxicidade , Humanos , Exposição por Inalação , Pulmão/patologia , Pessoa de Meia-Idade , Líquido da Lavagem Nasal/imunologia , Óxido Nítrico/análise , Óxido Nítrico/metabolismo , Doenças Profissionais/diagnóstico , Doenças Profissionais/epidemiologia , Exposição Ocupacional
12.
Ann Agric Environ Med ; 12(1): 53-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16028867

RESUMO

Respiratory exposure to organic dust induces chronic pulmonary diseases both in farmers and horses. The aim of this study was to examine the variation of dustiness and hygiene quality of peat moss bedding. Materials studied were weakly decomposed sphagnum peat (A), weakly decomposed sphagnum peat warmed up in storage (> 30 degrees C) (B) and two more decomposed few-flowered sedge peats (C and D). The geometric mean of mesophilic fungi, thermotolerant fungi and thermophilic actinomycetes were determined from the material. Samples of inhalable dust and endotoxins were collected with IOM samplers and respirable dust with 10M foam samplers when the peat was rotated in a cylinder. The number of particles was detected with an optical particle counter. An LAL assay was used for analysing endotoxins from the filter samples. There were differences in the hygiene quality and dustiness between peat materials (p < 0.01). The geometric mean of fungi was smallest in material A. Warming-up increased the number of fungi in sphagnum peat, but on the other hand, it decreased the content of endotoxin (p < 0.01). Few-flowered peat materials contained thermophilic actinomycetes and material D also contained Aspergillus fumigatus. The concentrations of inhalable dust, respirable dust and the number of particles were smaller in the few-flowered peats (C-D) than in the sphagnum peats (A-B). It is concluded that there are differences in the dustiness and hygiene quality of peat bedding.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Endotoxinas/isolamento & purificação , Fungos/isolamento & purificação , Cavalos , Higiene , Sphagnopsida/microbiologia , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Poluição do Ar em Ambientes Fechados/efeitos adversos , Animais , Finlândia , Doenças dos Cavalos/prevenção & controle , Humanos , Hipersensibilidade/veterinária , Fatores de Risco , Sphagnopsida/efeitos adversos
13.
Ann Occup Hyg ; 48(3): 197-202, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15059795

RESUMO

OBJECTIVES: The aim of the study was to measure the dermal exposure levels of chromium dust during grinding of stainless and acid-proof steel parts. METHODS: The potential dermal exposure of the body was measured with a patch sampling method and the actual exposure of hands with a hand-wash method. Simultaneously, personal air samples were also collected. RESULTS: The range of body and hand exposure to chromium dust was 4.04-3406 and 0.72-79.7 mg/h, respectively. Dust was distributed quite evenly to different body parts. CONCLUSIONS: Workers using hand-held grinding tools were more exposed than those using band grinders. It was judged that the sampling methods applied in this study gave a realistic estimation of exposure levels, because of the uniform distribution of contamination during grinding. Respiratory exposure was high compared to Finnish occupational exposure limit values.


Assuntos
Cromo/análise , Poeira , Metalurgia , Exposição Ocupacional/análise , Pele , Análise de Variância , Luvas Protetoras , Mãos , Humanos , Exposição por Inalação/efeitos adversos , Testes do Emplastro/métodos , Aço , Ventilação
14.
Ann Occup Hyg ; 48(3): 277-83, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15059804

RESUMO

OBJECTIVES: The aim of the study was to measure the dermal and respiratory exposure levels of hexavalent chromium during electroplating work. METHODS: Potential dermal exposure of the body was measured with patch samples and actual exposure of hands with hand-wash samples. For comparison, personal air samples were also collected. RESULTS: The exposure varied widely between workers. The range of body and hand exposure to the electroplating solution was 0.17-28.1 mg/h and 0.04-6.37 mg/h, respectively. Hands and lower limbs were the most contaminated body parts. CONCLUSIONS: The results of breathing zone samples and dermal exposure did not correlate with each other. In manual electroplating processes, dermal exposure was higher than in semi-automatic and automatic processes. The amount of hexavalent chromium the workers were exposed to is probably high enough to cause a risk of skin sensitization.


Assuntos
Cromo/análise , Galvanoplastia , Exposição Ocupacional/análise , Pele , Análise de Variância , Automação , Mãos , Desinfecção das Mãos , Humanos , Exposição por Inalação/análise , Perna (Membro) , Testes do Emplastro/métodos
15.
AIHA J (Fairfax, Va) ; 64(4): 496-500, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12908865

RESUMO

The study evaluated the effects of triazine use and machine enclosure on workers' exposure to bacteria, endotoxins, and formaldehyde in the use of metalworking fluids (MWF). Concentrations of triazine and bacterial contaminants were monitored in bulk samples of MWF from two machines in one workplace. One of the machines was used normally; triazine was added to the other when needed. Air sampling was used to estimate workers' exposure to endotoxins at 18 workplaces near enclosed and open machines. Concentrations of triazine in MWF and formaldehyde in the air were measured. Some recirculating local exhaust ventilation systems were also tested. The endotoxin and bacteria concentrations in the biocide test of MWF rapidly increased when the biocide levels decreased below 500 ppm. Airborne concentrations of endotoxins were substantially lower near enclosed machines than near open ones. Concentrations of airborne formaldehyde were below the Finnish occupational exposure limit at the existing levels of triazine in MWF. Concentrations of triazine in MWF correlated well with those of formaldehyde in the air near the machines (correlation coefficient r=.69). The results showed that the triazine levels in MWF should continuously be kept high enough (>500 ppm) to prevent workers' exposure to endotoxins and bacteria. Overdosing with triazine, however, should be avoided, so that the levels of airborne formaldehyde remain low. Triazine levels in MWF can be followed by the method described in this article. Workers' exposure to contaminants of MWF can be reduced substantially by enclosing the machines and equipping them with local exhausts.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Desinfetantes/análise , Endotoxinas/análise , Formaldeído/análise , Exposição Ocupacional , Ventilação , Aerossóis , Bactérias , Desenho de Equipamento , Humanos , Metalurgia , Triazinas/análise , Local de Trabalho
16.
AIHA J (Fairfax, Va) ; 64(3): 312-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12809536

RESUMO

The performances of eight sampling devices were tested with mineral dusts in the laboratory and in a talc production plant. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM samplers provided with the porous plastic foam media were used as the reference methods for both the thoracic and respirable aerosols. The other size-selective instruments tested included the Respicon virtual impactor, the optical GRIMM aerosol monitor, and a two-stage cascade impactor with cut points of 10 and 4 microm. The 37-mm cassettes were also included both as open- and closed-face versions. The study confirmed the usability of the IOM samplers for mineral dust, not only in its original version for the inhalable fraction but also its modified versions for the thoracic and respirable fractions. A high correlation with the two-stage impactor results is an indication of good reproducibility. The results increased the evidence that the 37-mm cassette is a poor indicator of inhalable aerosol. The concentrations obtained with both cassette methods were not only systematically too low but also showed large collection efficiency variability. Therefore, the results cannot be corrected by using correction factors. The concentrations of inhalable aerosol measured with the Respicon were generally low, but its performances for the thoracic and respirable fractions were closer to those for the reference samplers. The results also indicate that the GRIMM monitor is well-suited for such mineral dust determinations when very good accuracy is not required, but the immediate availability of the result is more important.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poeira/análise , Monitoramento Ambiental/métodos , Exposição por Inalação , Humanos , Minerais , Tamanho da Partícula , Talco , Níveis Máximos Permitidos , Local de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA