Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38649588

RESUMO

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

2.
Heart Rhythm ; 21(5): 571-580, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286246

RESUMO

BACKGROUND: Three-dimensional (3D) mapping of the ventricular conduction system is challenging. OBJECTIVE: The purpose of this study was to use ripple mapping to distinguish conduction system activation to that of adjacent myocardium in order to characterize the conduction system in the postinfarct left ventricle (LV). METHODS: High-density mapping (PentaRay, CARTO) was performed during normal rhythm in patients undergoing ventricular tachycardia ablation. Ripple maps were viewed from the end of the P wave to QRS onset in 1-ms increments. Clusters of >3 ripple bars were interrogated for the presence of Purkinje potentials, which were tagged on the 3D geometry. Repeating this process allowed conduction system delineation. RESULTS: Maps were reviewed in 24 patients (mean 3112 ± 613 points). There were 150.9 ± 24.5 Purkinje potentials per map, at the left posterior fascicle (LPF) in 22 patients (92%) and at the left anterior fascicle (LAF) in 15 patients (63%). The LAF was shorter (41.4 vs 68.8 mm; P = .0005) and activated for a shorter duration (40.6 vs 64.9 ms; P = .002) than the LPF. Fourteen of 24 patients had left bundle branch block (LBBB), with 11 of 14 (78%) having Purkinje potential-associated breakout. There were fewer breakouts from the conduction system during LBBB (1.8 vs 3.4; 1.6 ± 0.6; P = .039) and an inverse correlation between breakout sites and QRS duration (P = .0035). CONCLUSION: We applied ripple mapping to present a detailed electroanatomic characterization of the conduction system in the postinfarct LV. Patients with broader QRS had fewer LV breakout sites from the conduction system. However, there was 3D mapping evidence of LV breakout from an intact conduction system in the majority of patients with LBBB.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco , Ventrículos do Coração , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Masculino , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Ablação por Cateter/métodos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/complicações , Eletrocardiografia , Ramos Subendocárdicos/fisiopatologia , Idoso , Imageamento Tridimensional , Mapeamento Potencial de Superfície Corporal/métodos
3.
J Cardiovasc Electrophysiol ; 35(3): 557-568, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37870146

RESUMO

RETRO-mapping was developed to automate activation mapping of atrial fibrillation (AF). We used the algorithm to study the effect of pulmonary vein isolation (PVI) on the frequency of focal, planar, and colliding wavefronts in persistent AF. An AFocusII catheter was placed on the left atrial endocardium to record 3 s of AF at six sites pre and post-PVI in patients undergoing wide circumferential PVI for persistent AF. RETRO-mapping analyzed each segment in 2 ms time windows for evidence of focal, planar, and colliding waveforms and the automated categorizations manually validated. Ten patients were recruited. A total of 360 s of data in 120 segments of 3 s from 60 left atrial locations were analyzed. RETRO-map was highly effective at identifying focal waves and collisions during AF. PVI significantly reduced collision frequency but not focal and planar activation frequency. However, there was a significant reduction in the dispersion of activation directions. Larger studies may help determine factors associated with successful clinical outcome.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Algoritmos , Resultado do Tratamento , Recidiva
4.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37815462

RESUMO

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodos
5.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
6.
JMIR Nurs ; 6: e44630, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37279054

RESUMO

BACKGROUND: Community-based management by heart failure specialist nurses (HFSNs) is key to improving self-care in heart failure with reduced ejection fraction. Remote monitoring (RM) can aid nurse-led management, but in the literature, user feedback evaluation is skewed in favor of the patient rather than nursing user experience. Furthermore, the ways in which different groups use the same RM platform at the same time are rarely directly compared in the literature. We present a balanced semantic analysis of user feedback from patient and nurse perspectives of Luscii, a smartphone-based RM strategy combining self-measurement of vital signs, instant messaging, and e-learning. OBJECTIVE: This study aims to (1) evaluate how patients and nurses use this type of RM (usage type), (2) evaluate patients' and nurses' user feedback on this type of RM (user experience), and (3) directly compare the usage type and user experience of patients and nurses using the same type of RM platform at the same time. METHODS: We performed a retrospective usage type and user experience evaluation of the RM platform from the perspective of both patients with heart failure with reduced ejection fraction and the HFSNs using the platform to manage them. We conducted semantic analysis of written patient feedback provided via the platform and a focus group of 6 HFSNs. Additionally, as an indirect measure of tablet adherence, self-measured vital signs (blood pressure, heart rate, and body mass) were extracted from the RM platform at onboarding and 3 months later. Paired 2-tailed t tests were used to evaluate differences between mean scores across the 2 timepoints. RESULTS: A total of 79 patients (mean age 62 years; 35%, 28/79 female) were included. Semantic analysis of usage type revealed extensive, bidirectional information exchange between patients and HFSNs using the platform. Semantic analysis of user experience demonstrates a range of positive and negative perspectives. Positive impacts included increased patient engagement, convenience for both user groups, and continuity of care. Negative impacts included information overload for patients and increased workload for nurses. After the patients used the platform for 3 months, they showed significant reductions in heart rate (P=.004) and blood pressure (P=.008) but not body mass (P=.97) compared with onboarding. CONCLUSIONS: Smartphone-based RM with messaging and e-learning facilitates bilateral information sharing between patients and nurses on a range of topics. Patient and nurse user experience is largely positive and symmetrical, but there are possible negative impacts on patient attention and nurse workload. We recommend RM providers involve patient and nurse users in platform development, including recognition of RM usage in nursing job plans.

7.
J Med Artif Intell ; 6: 4, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37346802

RESUMO

Background: Getting the most value from expert clinicians' limited labelling time is a major challenge for artificial intelligence (AI) development in clinical imaging. We present a novel method for ground-truth labelling of cardiac magnetic resonance imaging (CMR) image data by leveraging multiple clinician experts ranking multiple images on a single ordinal axis, rather than manual labelling of one image at a time. We apply this strategy to train a deep learning (DL) model to classify the anatomical position of CMR images. This allows the automated removal of slices that do not contain the left ventricular (LV) myocardium. Methods: Anonymised LV short-axis slices from 300 random scans (3,552 individual images) were extracted. Each image's anatomical position relative to the LV was labelled using two different strategies performed for 5 hours each: (I) 'one-image-at-a-time': each image labelled according to its position: 'too basal', 'LV', or 'too apical' individually by one of three experts; and (II) 'multiple-image-ranking': three independent experts ordered slices according to their relative position from 'most-basal' to 'most apical' in batches of eight until each image had been viewed at least 3 times. Two convolutional neural networks were trained for a three-way classification task (each model using data from one labelling strategy). The models' performance was evaluated by accuracy, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Results: After excluding images with artefact, 3,323 images were labelled by both strategies. The model trained using labels from the 'multiple-image-ranking strategy' performed better than the model using the 'one-image-at-a-time' labelling strategy (accuracy 86% vs. 72%, P=0.02; F1-score 0.86 vs. 0.75; ROC AUC 0.95 vs. 0.86). For expert clinicians performing this task manually the intra-observer variability was low (Cohen's κ=0.90), but the inter-observer variability was higher (Cohen's κ=0.77). Conclusions: We present proof of concept that, given the same clinician labelling effort, comparing multiple images side-by-side using a 'multiple-image-ranking' strategy achieves ground truth labels for DL more accurately than by classifying images individually. We demonstrate a potential clinical application: the automatic removal of unrequired CMR images. This leads to increased efficiency by focussing human and machine attention on images which are needed to answer clinical questions.

8.
JMIR Cardio ; 7: e45611, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37351921

RESUMO

BACKGROUND: Despite effective therapies, the economic burden of heart failure with reduced ejection fraction (HFrEF) is driven by frequent hospitalizations. Treatment optimization and admission avoidance rely on frequent symptom reviews and monitoring of vital signs. Remote monitoring (RM) aims to prevent admissions by facilitating early intervention, but the impact of noninvasive, smartphone-based RM of vital signs on secondary health care use and costs in the months after a new diagnosis of HFrEF is unknown. OBJECTIVE: The purpose of this study is to conduct a secondary care health use and health-economic evaluation for patients with HFrEF using smartphone-based noninvasive RM and compare it with matched controls receiving usual care without RM. METHODS: We conducted a retrospective study of 2 cohorts of newly diagnosed HFrEF patients, matched 1:1 for demographics, socioeconomic status, comorbidities, and HFrEF severity. They are (1) the RM group, with patients using the RM platform for >3 months and (2) the control group, with patients referred before RM was available who received usual heart failure care without RM. Emergency department (ED) attendance, hospital admissions, outpatient use, and the associated costs of this secondary care activity were extracted from the Discover data set for a 3-month period after diagnosis. Platform costs were added for the RM group. Secondary health care use and costs were analyzed using Kaplan-Meier event analysis and Cox proportional hazards modeling. RESULTS: A total of 146 patients (mean age 63 years; 42/146, 29% female) were included (73 in each group). The groups were well-matched for all baseline characteristics except hypertension (P=.03). RM was associated with a lower hazard of ED attendance (hazard ratio [HR] 0.43; P=.02) and unplanned admissions (HR 0.26; P=.02). There were no differences in elective admissions (HR 1.03, P=.96) or outpatient use (HR 1.40; P=.18) between the 2 groups. These differences were sustained by a univariate model controlling for hypertension. Over a 3-month period, secondary health care costs were approximately 4-fold lower in the RM group than the control group, despite the additional cost of RM itself (mean cost per patient GBP £465, US $581 vs GBP £1850, US $2313, respectively; P=.04). CONCLUSIONS: This retrospective cohort study shows that smartphone-based RM of vital signs is feasible for HFrEF. This type of RM was associated with an approximately 2-fold reduction in ED attendance and a 4-fold reduction in emergency admissions over just 3 months after a new diagnosis with HFrEF. Costs were significantly lower in the RM group without increasing outpatient demand. This type of RM could be adjunctive to standard care to reduce admissions, enabling other resources to help patients unable to use RM.

9.
J Cardiovasc Electrophysiol ; 34(5): 1119-1126, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36906811

RESUMO

INTRODUCTION: A quantifiable, automated standard of analyzing heart rhythm has long eluded cardiologists due, in part, to the limitations in technology and the ability to analyze large electrogram datasets. In this proof-of-concept study, we propose new measures to quantify plane activity in atrial fibrillation (AF) using our Representation of Electrical Tracking of Origin (RETRO)-Mapping software. METHODS: We recorded 30 s segments of electrograms at the lower posterior wall of the left atrium using a 20-pole double loop catheter (AFocusII). The data were analyzed with the custom RETRO-Mapping algorithm in MATLAB. Thirty second segments were analyzed for number of activation edges, conduction velocity (CV), cycle length (CL), activation edge direction, and wavefront direction. These features were compared across 34 613 plane edges in three types of AF: persistent AF treated with amiodarone (11 906 wavefronts), persistent AF without amiodarone (14 959 wavefronts), and paroxysmal AF (7748 wavefronts). Change in activation edge direction between subsequent frames and change in overall wavefront direction between subsequent wavefronts were analyzed. RESULTS: All activation edge directions were represented across the lower posterior wall. The median change in activation edge direction followed a linear pattern for all three types of AF with R2 = 0.932 for persistent AF treated without amiodarone, R2 = 0.942 for paroxysmal AF, and R2 = 0.958 for persistent AF treated with amiodarone. All medians and the standard deviation error bars remained below 45° (suggesting all activation edges were traveling within a 90° sector, a criterion for plane activity). The directions of approximately half of all wavefronts (56.1% for persistent without amiodarone, 51.8% for paroxysmal, 48.8% for persistent with amiodarone) were predictive of the directions of the subsequent wavefront. CONCLUSION: RETRO-Mapping can measure electrophysiological features of activation activity and this proof-of-concept study suggests that this can be extended to the detection of plane activity in three types of AF. Wavefront direction may have a role in future work for predicting plane activity. For this study, we focused more on the ability of the algorithm to detect plane activity and less the differences between the types of AF. Future work should be in validating these results with a larger data set and comparing with other types of activation such as rotational, collision, and focal. Ultimately, this work can be implemented in real-time for prediction of wavefronts during ablation procedures.


Assuntos
Amiodarona , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Eletrofisiologia Cardíaca , Catéteres , Amiodarona/uso terapêutico , Ablação por Cateter/métodos
10.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734205

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodos
12.
Europace ; 25(2): 726-738, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36260428

RESUMO

AIMS: The response to high frequency stimulation (HFS) is used to locate putative sites of ganglionated plexuses (GPs), which are implicated in triggering atrial fibrillation (AF). To identify topological and immunohistochemical characteristics of presumed GP sites functionally identified by HFS. METHODS AND RESULTS: Sixty-three atrial sites were tested with HFS in four Langendorff-perfused porcine hearts. A 3.5 mm tip quadripolar ablation catheter was used to stimulate and deliver HFS to the left and right atrial epicardium, within the local atrial refractory period. Tissue samples from sites triggering atrial ectopy/AF (ET) sites and non-ET sites were stained with choline acetyltransferase (ChAT) and tyrosine hydroxylase (TH), for quantification of parasympathetic and sympathetic nerves, respectively. The average cross-sectional area (CSA) of nerves was also calculated. Histomorphometry of six ET sites (9.5%) identified by HFS evoking at least a single atrial ectopic was compared with non-ET sites. All ET sites contained ChAT-immunoreactive (ChAT-IR) and/or TH-immunoreactive nerves (TH-IR). Nerve density was greater in ET sites compared to non-ET sites (nerves/cm2: 162.3 ± 110.9 vs. 69.65 ± 72.48; P = 0.047). Overall, TH-IR nerves had a larger CSA than ChAT-IR nerves (µm2: 11 196 ± 35 141 vs. 2070 ± 5841; P < 0.0001), but in ET sites, TH-IR nerves were smaller than in non-ET sites (µm2: 6021 ± 14 586 vs. 25 254 ± 61 499; P < 0.001). CONCLUSIONS: ET sites identified by HFS contained a higher density of smaller nerves than non-ET sites. The majority of these nerves were within the atrial myocardium. This has important clinical implications for devising an effective therapeutic strategy for targeting autonomic triggers of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Fibrilação Atrial/cirurgia , Átrios do Coração , Miocárdio , Sistema Nervoso Autônomo , Ablação por Cateter/métodos
13.
Front Physiol ; 12: 712454, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34858198

RESUMO

Background: Atrial fibrillation (AF) and ventricular fibrillation (VF) are complex heart rhythm disorders and may be sustained by distinct electrophysiological mechanisms. Disorganised self-perpetuating multiple-wavelets and organised rotational drivers (RDs) localising to specific areas are both possible mechanisms by which fibrillation is sustained. Determining the underlying mechanisms of fibrillation may be helpful in tailoring treatment strategies. We investigated whether global fibrillation organisation, a surrogate for fibrillation mechanism, can be determined from electrocardiograms (ECGs) using band-power (BP) feature analysis and machine learning. Methods: In this study, we proposed a novel ECG classification framework to differentiate fibrillation organisation levels. BP features were derived from surface ECGs and fed to a linear discriminant analysis classifier to predict fibrillation organisation level. Two datasets, single-channel ECGs of rat VF (n = 9) and 12-lead ECGs of human AF (n = 17), were used for model evaluation in a leave-one-out (LOO) manner. Results: The proposed method correctly predicted the organisation level from rat VF ECG with the sensitivity of 75%, specificity of 80%, and accuracy of 78%, and from clinical AF ECG with the sensitivity of 80%, specificity of 92%, and accuracy of 88%. Conclusion: Our proposed method can distinguish between AF/VF of different global organisation levels non-invasively from the ECG alone. This may aid in patient selection and guiding mechanism-directed tailored treatment strategies.

14.
Heart Rhythm O2 ; 2(5): 439-445, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667958

RESUMO

BACKGROUND: His bundle pacing (HBP) can be achieved in 2 ways: selective HBP (S-HBP), where the His bundle is captured alone, and nonselective HBP (NS-HBP), where local myocardium is also captured, resulting a pre-excited electrocardiogram appearance. OBJECTIVE: We assessed the impact of this ventricular pre-excitation on left and right ventricular dyssynchrony. METHODS: We recruited patients who displayed both S-HBP and NS-HBP. We performed noninvasive epicardial electrical mapping for left and right ventricular activation time (LVAT and RVAT) and pattern. RESULTS: Twenty patients were recruited. In the primary analysis, the mean within-patient change in LVAT from S-HBP to NS-HBP was -5.5 ms (95% confidence interval: -0.6 to -10.4, noninferiority P < .0001). NS-HBP did not prolong RVAT (4.3 ms, -4.0 to 12.8, P = .296) but did prolong QRS duration (QRSd, 22.1 ms, 11.8 to 32.4, P = .0003). In patients with narrow intrinsic QRS (n = 6), NS-HBP preserved LVAT (-2.9 ms, -9.7 to 4.0, P = .331) but prolonged QRS duration (31.4 ms, 22.0 to 40.7, P = .0003) and mean RVAT (16.8 ms, -5.3 to 38.9, P = .108) compared to S-HBP. Activation pattern of the left ventricular surface was unchanged between S-HBP and NS-HBP, but NS-HBP produced early basal right ventricular activation that was not seen in S-HBP. CONCLUSION: Compared to S-HBP, local myocardial capture during NS-HBP produces pre-excitation of the basal right ventricle resulting in QRS duration prolongation. However, NS-HBP preserves the left ventricular activation time and pattern of S-HBP. Left ventricular dyssynchrony is not an important factor when choosing between S-HBP and NS-HBP in most patients.

16.
Front Physiol ; 12: 646023, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33716795

RESUMO

BACKGROUND: Electroanatomic mapping systems are used to support electrophysiology research. Data exported from these systems is stored in proprietary formats which are challenging to access and storage-space inefficient. No previous work has made available an open-source platform for parsing and interrogating this data in a standardized format. We therefore sought to develop a standardized, open-source data structure and associated computer code to store electroanatomic mapping data in a space-efficient and easily accessible manner. METHODS: A data structure was defined capturing the available anatomic and electrical data. OpenEP, implemented in MATLAB, was developed to parse and interrogate this data. Functions are provided for analysis of chamber geometry, activation mapping, conduction velocity mapping, voltage mapping, ablation sites, and electrograms as well as visualization and input/output functions. Performance benchmarking for data import and storage was performed. Data import and analysis validation was performed for chamber geometry, activation mapping, voltage mapping and ablation representation. Finally, systematic analysis of electrophysiology literature was performed to determine the suitability of OpenEP for contemporary electrophysiology research. RESULTS: The average time to parse clinical datasets was 400 ± 162 s per patient. OpenEP data was two orders of magnitude smaller than compressed clinical data (OpenEP: 20.5 ± 8.7 Mb, vs clinical: 1.46 ± 0.77 Gb). OpenEP-derived geometry metrics were correlated with the same clinical metrics (Area: R 2 = 0.7726, P < 0.0001; Volume: R 2 = 0.5179, P < 0.0001). Investigating the cause of systematic bias in these correlations revealed OpenEP to outperform the clinical platform in recovering accurate values. Both activation and voltage mapping data created with OpenEP were correlated with clinical values (mean voltage R 2 = 0.8708, P < 0.001; local activation time R 2 = 0.8892, P < 0.0001). OpenEP provides the processing necessary for 87 of 92 qualitatively assessed analysis techniques (95%) and 119 of 136 quantitatively assessed analysis techniques (88%) in a contemporary cohort of mapping studies. CONCLUSIONS: We present the OpenEP framework for evaluating electroanatomic mapping data. OpenEP provides the core functionality necessary to conduct electroanatomic mapping research. We demonstrate that OpenEP is both space-efficient and accurately representative of the original data. We show that OpenEP captures the majority of data required for contemporary electroanatomic mapping-based electrophysiology research and propose a roadmap for future development.

17.
J Cardiovasc Electrophysiol ; 32(2): 235-244, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33421265

RESUMO

BACKGROUND: Ganglionated plexuses (GPs) are implicated in atrial fibrillation (AF). Endocardial high-frequency stimulation (HFS) delivered within the local atrial refractory period can trigger ectopy and AF from specific GP sites (ET-GP). The aim of this study was to understand the role of ET-GP ablation in the treatment of AF. METHODS: Patients with paroxysmal AF indicated for ablation were recruited. HFS mapping was performed globally around the left atrium to identify ET-GP. ET-GP was defined as atrial ectopy or atrial arrhythmia triggered by HFS. All ET-GP were ablated, and PVs were left electrically connected. Outcomes were compared with a control group receiving pulmonary vein isolation (PVI). Patients were followed-up for 12 months with multiple 48-h Holter ECGs. Primary endpoint was ≥30 s AF/atrial tachycardia in ECGs. RESULTS: In total, 67 patients were recruited and randomized to ET-GP ablation (n = 39) or PVI (n = 28). In the ET-GP ablation group, 103 ± 28 HFS sites were tested per patient, identifying 21 ± 10 (20%) GPs. ET-GP ablation used 23.3 ± 4.1 kWs total radiofrequency (RF) energy per patient, compared with 55.7 ± 22.7 kWs in PVI (p = <.0001). Duration of procedure was 3.7 ± 1.0 and 3.3 ± 0.7 h in ET-GP ablation group and PVI, respectively (p = .07). Follow-up at 12 months showed that 61% and 49% were free from ≥30 s of AF/AT with PVI and ET-GP ablation respectively (log-rank p = .27). CONCLUSIONS: It is feasible to perform detailed global functional mapping with HFS and ablate ET-GP to prevent AF. This provides direct evidence that ET-GPs are part of the AF mechanism. The lower RF requirement implies that ET-GP targets the AF pathway more specifically.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrocardiografia Ambulatorial , Átrios do Coração , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 32(2): 428-438, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33345379

RESUMO

BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento , Função Ventricular Esquerda
19.
Cardiovasc Digit Health J ; 1(1): 11-20, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32954375

RESUMO

BACKGROUND: His-bundle pacing (HBP) has emerged as an alternative to conventional ventricular pacing because of its ability to deliver physiological ventricular activation. Pacing at the His bundle produces different electrocardiographic (ECG) responses: selective His-bundle pacing (S-HBP), non-selective His bundle pacing (NS-HBP), and myocardium-only capture (MOC). These 3 capture types must be distinguished from each other, which can be challenging and time-consuming even for experts. OBJECTIVE: The purpose of this study was to use artificial intelligence (AI) in the form of supervised machine learning using a convolutional neural network (CNN) to automate HBP ECG interpretation. METHODS: We identified patients who had undergone HBP and extracted raw 12-lead ECG data during S-HBP, NS-HBP, and MOC. A CNN was trained, using 3-fold cross-validation, on 75% of the segmented QRS complexes labeled with their capture type. The remaining 25% was kept aside as a testing dataset. RESULTS: The CNN was trained with 1297 QRS complexes from 59 patients. Cohen kappa for the neural network's performance on the 17-patient testing set was 0.59 (95% confidence interval 0.30 to 0.88; P <.0001), with an overall accuracy of 75%. The CNN's accuracy in the 17-patient testing set was 67% for S-HBP, 71% for NS-HBP, and 84% for MOC. CONCLUSION: We demonstrated proof of concept that a neural network can be trained to automate discrimination between HBP ECG responses. When a larger dataset is trained to higher accuracy, automated AI ECG analysis could facilitate HBP implantation and follow-up and prevent complications resulting from incorrect HBP ECG analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...