Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-19308276

RESUMO

BACKGROUND: Currents of injury (COI) have been associated with improved lead performance during perioperative measurements in pacemaker and ICD implants. Their relevance on long term lead stability remains unclear. METHODS: Unipolar signals were recorded immediately after active fixation ICD lead positioning, blinded to the implanting surgeon. Signals were assigned to prespecified COI types by two independent investigators. Sensing, pacing as well as changes requiring surgical intervention were prospectively investigated for 3 months. RESULTS: 105 consecutive ICD lead implants were studied. All could be assigned to a particular COI with 48 type 1, 43 type 2 and 14 type 3 signals. Pacing impedance at implant was 703.8+/-151.6 Ohm with a significant COI independent drop within the first week. Sensing was 10.6mV+/- 3.7mV and pacing threshold at implant was 0.8+/-0.3mV at 0.5ms at implant. There was no significant difference between COI groups at implant and during a 3 months follow up regarding sensing, pacing nor surgical revisions. CONCLUSIONS: Three distinct patterns of unipolar endocardial potentials were observed in active fixation ICD lead implant, but COI morphology did not predict lead performance after 3 months.

2.
Am J Cardiol ; 102(6): 709-11, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18773993

RESUMO

Sleep apnea (SA) is more prevalent in patients with atrial fibrillation (AF), but the impact of cardioversion on disordered breathing is unknown. Thus, we investigated the influence of restoring sinus rhythm in patients with AF and atrial flutter (AFlut) on SA. The 16 patients (mean age 63.1 +/- 11.2) with AF (n = 6) or AFlut (n = 10) and SA (apnea-hypopnea index >10) received cardioversion or ablation of cavotricuspid isthmus. We compared the severity of SA by sleep polygraphy under AF/Aflut with the first night after restoring sinus rhythm and after 4 weeks. Apnea-hypopnea index before and immediately after restoring sinus rhythm was similar (31.7 +/- 13.2 vs 30.1 +/- 15.7, p = NS) despite a significantly reduced heart rate (86.7 +/- 26.5 vs 67.8 +/- 11.9 beats/min, p <0.02). After 4 weeks, apnea-hypopnea index remained unchanged (38.1 +/- 18.1, p = NS) although heart rate was further reduced (61.8 +/- 8.8 beats/min, p <0.003). In our study, SA could not be improved by cardioversion of AF/AFlut. Therefore, although it is well known that SA leads to AF, eliminating AF does not cure or improve SA. In conclusion, our study shows that AF should be regarded more as an innocent bystander than a causative or aggravating condition in SA.


Assuntos
Fibrilação Atrial/terapia , Flutter Atrial/terapia , Síndromes da Apneia do Sono/complicações , Fibrilação Atrial/complicações , Flutter Atrial/complicações , Ablação por Cateter , Cardioversão Elétrica , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Polissonografia , Estudos Prospectivos , Índice de Gravidade de Doença
3.
Heart Rhythm ; 5(6): 802-6, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18534363

RESUMO

BACKGROUND: Radiofrequency ablation of pulmonary veins (PVs) has emerged as an effective treatment for patients with paroxysmal atrial fibrillation (AF). However, serious complications raise concern about an even wider application. In terms of safety, cryoenergy has advantages compared with radiofrequency. A new cryoenergy balloon catheter has been recently developed to make AF ablation shorter and safer. OBJECTIVE: The purpose of this study was to test the 6-month efficacy of this new device for ablation of paroxysmal AF. METHODS: Twenty-one patients with highly symptomatic paroxysmal AF, normal left atrial size, and frequent episodes of AF were included. All PVs were targeted during cryoballoon ablation. Patients received 24-hour Holter electrocardiograms (ECGs) and event recorder during follow-up after 1, 3, and 6 months. RESULTS: A total of 81 (95%) of 85 PVs could be completely isolated with a single-balloon technique. Procedure time was 165 +/- 35 minutes, and fluoroscopy time was 39 +/- 9 minutes. After 6 months, 86% of the patients were free of symptomatic AF. In two of three patients with recurrence of AF, complete PV isolation has not been achieved initially. After a second procedure (1.04 procedures per patient), 90% of the patients were free of symptomatic AF. Three phrenic nerve palsies occurred during ablation of the right superior PV; two completely resolved after 6 and 9 months, and one is still persisting after 2 months. CONCLUSION: This is the first study that reports the results of the new cryoballoon AF ablation approach showing 86% freedom from AF recurrence after 6 months. Cryoballoon PV ablation promises to be effective for patients with paroxysmal AF and normally sized left atria.


Assuntos
Fibrilação Atrial/terapia , Oclusão com Balão/instrumentação , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Taquicardia Paroxística/terapia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Oclusão com Balão/métodos , Ablação por Cateter/métodos , Criocirurgia/métodos , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prevenção Secundária , Taquicardia Paroxística/fisiopatologia , Resultado do Tratamento
4.
Am J Cardiol ; 100(4): 635-9, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-17697820

RESUMO

The aim of the study was to examine the predictive value of N-terminal pro-brain natriuretic peptide (NT-pro-BNP) versus electrophysiologic study in patients with implantable cardioverter-defibrillators (ICDs) after myocardial infarction (MI). We prospectively studied 99 consecutive patients with a history of MI who underwent ICD implantation for primary or secondary prevention of sudden cardiac death. An electrophysiologic study was performed in all patients. Venous blood samples for NT-pro-BNP measurement were obtained at the beginning of the study. The primary end point was ventricular tachycardia or ventricular fibrillation (VT/VF) and the secondary end point was a composite of death, hospitalization for heart failure, or MI. On multivariate Cox regression analysis, NT-pro-BNP level at or greater than median (497 ng/L) was the only significant predictor for VT/VF occurrence (p = 0.047). Along with amiodarone use (p = 0.001), NT-pro-BNP levels higher than median were also associated with a higher risk of composite clinical events (p = 0.036). Kaplan-Meier analysis showed that patients with NT-pro-BNP level at or greater than median had a higher risk of experiencing VT/VF and composite clinical events than patients with NT-pro-BNP levels less than median (log-rank p <0.05). In conclusion, assay of NT-pro-BNP, which is easy to perform and widely available, is superior to electrophysiologic study for prediction of future outcomes in predominantly secondary prophylactic ICD recipients after MI. In the era of primary prophylactic ICD implantation without preimplantation electrophysiologic study, higher NT-pro-BNP levels might help to improve risk-adjusted concomitant antiarrhythmic therapy and device selection.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Idoso , Arritmias Cardíacas/sangue , Arritmias Cardíacas/complicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/sangue , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Prognóstico , Modelos de Riscos Proporcionais , Precursores de Proteínas , Fatores de Risco , Taxa de Sobrevida
5.
Pacing Clin Electrophysiol ; 30(7): 885-90, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17584270

RESUMO

BACKGROUND: Markers of myocardial injury and inflammation have been shown to be elevated following radiofrequency (RF) ablation. This study aimed to compare RF ablation and cryoablation for their impact on markers for myocardial injury and inflammation. METHODS: Nineteen patients received catheter ablation for atrial flutter by either cryoablation (10 patients) or open-irrigated RF ablation (nine patients). Venous blood samples for troponin T (TnT), creatinkinase (CK), and the cardiac isoenzyme MB (CKMB) were obtained before, at six hours after the end of ablation, and the following day. C-reactive protein (CRP) levels were measured before ablation and the following day. RESULTS: Bidirectional isthmus block was achieved in all patients. Cryoablation showed significantly higher TnT following ablation (0.85 microg/l +/- 0.39 microg/l) compared to RF ablation (0.36 microg/l +/- 0.24 microg/l; p= 0.01) with declining levels the following day (cryoablation: 0.58 microg/l +/- 0.20 microg/l; RF ablation 0.34 microg/l +/- 0.21 microg/l; p= 0.03). We observed equal findings for CK and CKMB, both significantly higher in cryoablation. RF ablation led to a nonsignificant rise in CK and CKMB. CRP was elevated significantly higher following RF ablation (12.3 mg/dl +/- 4.1 mg/dl) compared to cryoablation (6.9 mg/dl +/- 4.0 mg/dl; p= 0.01). CONCLUSIONS: We show reduced inflammation despite higher markers for myocardial injury in cryoablation. The difference in biomarkers reflects different lesion formation in cryoablation and RF ablation. Cryoablation shows less systemic inflammatory reaction. This might be due to less endothelial damage and surface thrombosis in cryoablation.


Assuntos
Flutter Atrial/sangue , Flutter Atrial/cirurgia , Biomarcadores/sangue , Ablação por Cateter , Criocirurgia , Idoso , Proteína C-Reativa/metabolismo , Creatina Quinase/sangue , Creatina Quinase Forma MB/sangue , Feminino , Humanos , Inflamação/sangue , Masculino , Pessoa de Meia-Idade , Necrose/sangue , Troponina T/sangue
6.
Europace ; 8(8): 618-24, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16864615

RESUMO

AIMS: Identification of risk factors for ventricular tachycardia/ventricular fibrillation (VT/VF) occurrence in patients with implantable cardioverter-defibrillators (ICD) is reasonable, because ICD patients with multiple risk factors might benefit from more aggressive anti-arrhythmic therapy for the prevention of arrhythmic events. Furthermore, in the era of prophylactic ICD therapy and limited healthcare resources, additional markers are needed for improved patient selection. METHODS AND RESULTS: Thus, in Prospective Analysis of Risk Factor for Appropriate ICD Therapy (PROFIT), we prospectively analyzed the role of ejection fraction (EF), N-terminal probrain natriuretic peptide (NT-proBNP), New York Heart Association (NYHA) class, atrial fibrillation, and QRS-duration as independent predictors for VT/VF occurrence in 250 ICD patients. Kaplan-Meier analysis showed that EF<40% (log-rank P=0.001), NT-proBNP levels higher than median (>or=405 ng/L; log-rank P=0.04), QRS-duration >or=150 ms (log-rank P=0.016), permanent atrial fibrillation (log-rank P=0.008), and higher NYHA class (log-rank P=0.029) were associated with VT/VF occurrence. By multivariate Cox regression analysis EF, QRS-duration and atrial fibrillation remained significantly associated with appropriate VT/VF therapy, whereas there was no relationship among NT-proBNP, NYHA class, and VT/VF occurrence. Stratifying patients according to the number of their independent risk factors (EF<40%, AF, QRS-width>or=150 ms) showed that patients with greater than or equal to two risk factors had a 100% 2-year risk of VT/VF occurrence, whereas patients with no or one risk factor had a 19.3 and 25% 2-year risk, respectively. CONCLUSIONS: EF<40%, permanent atrial fibrillation, and QRS>or=150 ms are independent predictors for VT/VF occurrence in predominantly secondary prophylactic ICD patients. Combining all independent predictors, we developed a risk score for VT/VF occurrence identifying a subgroup of patients with two or more risk factors who had a 100% 2-year risk. Future studies will reveal if this risk score helps to identify ICD patients suitable for empirical anti-arrhythmic therapy and to improve patient selection for prophylactic ICD therapy.


Assuntos
Antiarrítmicos/uso terapêutico , Desfibriladores Implantáveis , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Eletrocardiografia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Peptídeo Natriurético Encefálico/fisiologia , Seleção de Pacientes , Fragmentos de Peptídeos/fisiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Taquicardia Ventricular/classificação , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/classificação , Fibrilação Ventricular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...