Resultados 1 - 8 de 8
Filtrar
1.
JACC Case Rep ; 29(9): 102300, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38708429

RESUMO

We present the case of an 82-year-old woman with history of bivalvular replacement (mitral mechanical prothesis and tricuspid bioprothesis) and subsequent tricuspid percutaneous valve-in-valve bioprothesis implantation. The patient developed an indication for pacemaker implantation. We describe the feasibility of leadless pacemaker implantation across the tricuspid prothesis when all other techniques fail.

2.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36709469

RESUMO

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Assuntos
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedância Elétrica , Estudos Retrospectivos , Fibrilação Ventricular , Desfibriladores Implantáveis
3.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36543505

RESUMO

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Assuntos
Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Pontuação de Propensão , Resultado do Tratamento , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Cardioversão Elétrica
4.
J Arrhythm ; 36(2): 353-362, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32256887

RESUMO

BACKGROUND: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D). METHODS: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE). RESULTS: In a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV, P < .01). The adjusted HR for 24 h AHRE in patients with atrial sensing >1.5 mV vs those with values ≤1.5 mV was 0.52 (95% CI: 0.33-0.83), P = .006. CONCLUSIONS: Although lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.

5.
Clin Cardiol ; 42(9): 820-828, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31282000

RESUMO

BACKGROUND: The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor. HYPOTHESIS: The presence of an association between RR and the incidence of AHREs. METHODS: Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time-dependent proportional-hazard models, averaging over 30-day periods and adjusting for main baseline variables. RESULTS: After a median follow-up of 23.9 (12.2-36.0) months, 507 (60.6%) patients experienced at least one 15-minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (<68 bpm). Higher mean heart rates increased AHRE risk (HR:1.02, P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence. CONCLUSIONS: RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.

6.
Europace ; 20(9): 1475-1483, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29186401

RESUMO

Aim: Ventricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry. Methods and results: A total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres. The primary endpoint was the number of patients with any appropriate implantable cardioverter-defibrillator (ICD) interventions during 12-month follow-up. The secondary endpoint comprised death from any cause and appropriate ICD interventions. At replacement, 214 (64.5%) patients had a left ventricular ejection fraction ≤ 35% and 138 (41.6%) patients had a secondary prevention indication for ICD. Seventy (21.1%) patients had no longer indication to ICD therapy. During a median follow-up period of 406.5 (362-533) days, VT/VF requiring therapy delivery occurred in 57 (17%) patients, specifically in 7% of those who no longer had an ICD indication. On multivariate analysis, number of criteria for ICD replacement independently predicted appropriate ICD intervention during follow-up [hazard ratio (HR) = 1.62, 95% confidence interval (CI) 1.07-2.46; log-rank P = 0.02]. The combined endpoint of death from any cause or appropriate ICD therapy occurred in 76 (23%) patients. Only NYHA class remained associated with this combined endpoint (HR = 1.97, 95% CI 1.23-3.14; P = 0.005). Conclusions: The DECODE registry showed the 'real-world' experience of CRT-D recipients approaching device replacement, in which 7% of patients who no longer had an indication for ICD therapy experienced appropriate ICD interventions.


Assuntos
Fibrilação Atrial/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Implantação de Prótese , Taquicardia Ventricular/epidemiologia , Fibrilação Ventricular/epidemiologia , Idoso , Terapia de Ressincronização Cardíaca , Remoção de Dispositivo , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Modelos de Riscos Proporcionais , Volume Sistólico
7.
J Cardiovasc Med (Hagerstown) ; 18(12): 968-975, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29028784

RESUMO

AIMS: Some barriers seem to exist in changing implantable cardioverter defibrillator (ICD) manufacturer at the time of device replacement. We sought to understand the obstacles to changing ICD manufacturer within the cohort of patients enrolled in the Detect Long-term Complications After ICD Replacement Registry. METHODS: We analyzed 784 consecutive ICD/cardiac resynchronization therapy defibrillator (CRT-D) device replacements within a 1.5-year time-frame in 36 Italian centers to evaluate potential factors associated with changing manufacturers and system-related complications. RESULTS: Manufacturer change occurred in 191 patients (24%): 72/211 single-chamber ICDs (34%), 52/210 dual-chamber ICDs (25%) and 67/363 CRT-D (18%, P < 0.0001 vs. single-chamber). Replacement-only procedures were associated with a lower rate of manufacturer change than upgrading procedures (23 vs. 32%, P = 0.02). In the single-chamber/dual-chamber cohort, the only variables associated with manufacturer change were the number of available manufacturers (OR = 1.9; P < 0.0001) and an upgrade procedure (OR = 1.7; P = 0.035), whereas the center volume was associated with maintenance of the same manufacturer (OR = 0.5; P = 0.0172). In the CRT-D group, the number of available manufacturers [OR = 2.9; P < 0.0001, service life below the median value (OR = 2.5; P = 0.0026)], and physiological design (OR = 8.4; P = 0.0048) were associated with manufacturer change. At 6-month follow-up, 17 patients (2.2%) experienced a system complication that was lead-related in all cases; upgrade procedure was the only predictor (hazard ratio = 6.7) of complications. CONCLUSION: At the time of ICD replacement, a manufacturer change occurred in 24% of patients and it was less likely in CRT-D devices, which are equipped with more specific technology and less frequently require the addition of features. System-related complications are strongly associated to upgrade procedures rather than to manufacturer change.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Índice de Gravidade de Doença
8.
G Ital Cardiol (Rome) ; 13(10 Suppl 2): 139S-144S, 2012 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-23096393

RESUMO

Epidemiological data show an even greater prevalence of heart failure in the general population, in particular in elderly people, both in Italy and the other European countries. Patients admitted to hospital because of heart failure are commonly complex patients with relevant comorbidities and frequent readmissions. Hospital care accounts largely for the costs due to heart failure, whereas expenditure for therapies (drugs, devices and surgery) is less significant; non-medical and social costs represent also a relevant part of total costs. By far, the real challenge in the care of heart failure patients consists in the efforts to reduce hospital readmissions. A broad spectrum of interventions has been proposed for improving care of heart failure patients: multidisciplinary interventions involving physicians and nurses consisting of different modalities of transtelephonic monitoring have been demonstrated to be effective in reducing readmission rates and improving patient outcome. New technologies for remote monitoring with implantable devices (defibrillators and pacemakers) are becoming the standard of clinical practice in a great number of cardiology departments in our country. In addition, implantable devices for automatic and continuous hemodynamic monitoring are in an advanced phase of clinical evaluation. In conclusion, new modalities of care, centered on out-of-hospital assistance by means of interactive as well as automatic remote monitoring, are now available and seem to impact positively on the growing need for resources to be allocated to the care of heart failure patients.


Assuntos
Insuficiência Cardíaca , Custos e Análise de Custo , Atenção à Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Itália