Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
J Card Fail ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851449

RESUMO

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
ESC Heart Fail ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581135

RESUMO

AIMS: Right ventricular failure after left ventricular assist device (LVAD) implantation is a major concern that remains challenging to predict. We sought to investigate the relationship between preoperative pulmonary artery pulsatility index (PAPi) and mortality after LVAD implantation. METHODS AND RESULTS: A retrospective analysis of the ASSIST-ICD multicentre registry allowed the assessment of PAPi before LVAD according to the formula [(systolic pulmonary artery pressure - diastolic pulmonary artery pressure)/central venous pressure]. The primary endpoint was survival at 3 months, according to the threshold value of PAPi determined by the receiver operating characteristic (ROC) curve. A multivariate analysis including demographic, echographic, haemodynamic, and biological variables was performed to identify predictive factors for 2 year mortality. One hundred seventeen patients were included from 2007 to 2021. The mean age was 58.45 years (±13.16), with 15.4% of women (sex ratio 5.5). A total of 53.4% were implanted as bridge to transplant and 43.1% as destination therapy. Post-operative right ventricular failure was observed in 57 patients (48.7%), with no significant difference between survivors and non-survivors at 1 month (odds ratio 1.59, P = 0.30). The median PAPi for the whole study population was 2.83 [interquartile range 1.63-4.69]. The threshold value of PAPi determined by the ROC curve was 2.84. Patients with PAPi ≥ 2.84 had a higher survival rate at 3 months [PAPi < 2.84: 58.1% [46.3-72.8%] vs. PAPi ≥ 2.84: 89.1% [81.1-97.7%], hazard ratio (HR) 0.08 [0.02-0.28], P < 0.01], with no significant difference after 3 months (HR 0.67 [0.17-2.67], P = 0.57). Other predictors of 2 year mortality were systemic hypertension (HR 4.22 [1.49-11.97], P < 0.01) and diabetes mellitus (HR 4.90 [1.83-13.14], P < 0.01). LVAD implantation as bridge to transplant (HR 0.18 [0.04-0.74], P = 0.02) and heart transplantation (HR 0.02 [0.00-0.18], P < 0.01) were associated with a higher survival rate at 2 years. CONCLUSIONS: Preoperative PAPi < 2.84 was associated with a higher risk of early mortality after LVAD implantation without impacting 2 year outcomes among survivors.

3.
Arch Cardiovasc Dis ; 115(4): 196-205, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35559901

RESUMO

BACKGROUND: Since the first-in-man implantation of a transcatheter aortic stented valve in April 2002 in Rouen, the procedure has expanded worldwide. In our centre, all transfemoral procedures have been performed using local anaesthesia without transoesophageal echocardiographic monitoring. AIM: To report our experience of transfemoral arterial transcatheter aortic valve implantation (TAVI) over the last 2 decades, following the evolution of devices, practices and indications. METHODS: Between 2002 and 2021, 2097 consecutive patients had a TAVI procedure in our centre. Among them, 1780 underwent transfemoral arterial aortic valve implantation, and were subdivided into three groups according to the time period: before 2009; 2009-2014; and 2014-2021. RESULTS: Median age was 85 years, and remained unchanged over time. The mean logistic EuroSCORE gradually decreased over time (28% before 2009 vs 15% for 2009-2014 vs 11% since 2014; P<0.001). Predilatation was performed almost systematically before 2009 (93%), but was rarely performed in the last period (14%; P<0.001). Thirty-day all-cause mortality decreased over time, and was only 1.4% in 2021. Length of stay decreased considerably, with a median duration of only 2 days after the procedure, and>70% of patients were discharged home within 72hours. Similarly, procedural duration, X-ray time and contrast volume decreased over time. CONCLUSION: Transfemoral aortic valve implantation, performed as a minimalist "stent-like" procedure using only local anaesthesia, is feasible in the vast majority of patients, with excellent outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Stents , Resultado do Tratamento
4.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34974497

RESUMO

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
5.
ESC Heart Fail ; 8(6): 5159-5167, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34494391

RESUMO

AIMS: Despite regularly updated guidelines, there is still a delay in referral of advanced heart failure patients to mechanical circulatory support and transplant centres. We aimed to analyse characteristics and outcome of non-inotrope-dependent patients implanted with a left ventricular assist device (LVAD). METHODS AND RESULTS: The ASSIST-ICD registry collected LVAD data in 19 centres in France between February 2006 and December 2016. We used data of patients in Interagency Registry for Mechanically Assisted Circulatory Support Classes 4-7. The primary endpoint was survival analysis. Predictors of mortality were searched with multivariable analyses. A total of 303 patients (mean age 61.0 ± 9.9 years, male sex 86.8%) were included in the present analysis. Ischaemic cardiomyopathy was the leading heart failure aetiology (64%), and bridge to transplantation was the main implantation strategy (56.1%). The overall likelihood of being alive while on LVAD support or having a transplant at 1, 2, 3, and 5 years was 66%, 61.7%, 58.7%, and 55.1%, respectively. Age [hazard ratio (HR) 1.03, 95% confidence interval (CI) 1.00-1.05; P = 0.02], a concomitant procedure (HR 2.32, 95% CI 1.52-3.53; P < 0.0001), and temporary mechanical right ventricular support during LVAD implantation (HR 2.94, 95% CI 1.49-5.77; P = 0.002) were the only independent variables associated with mortality. Heart failure medications before or after LVAD implantation were not associated with survival. CONCLUSION: Ambulatory heart failure patients displayed unsatisfactory survival rates after LVAD implantation. A better selection of patients who can benefit from LVAD may help improving outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taxa de Sobrevida , Resultado do Tratamento
6.
Am J Cardiol ; 146: 82-88, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33549526

RESUMO

LVAD implantation in patients with a recently diagnosed cardiomyopathy has been poorly investigated. This work aims at describing the characteristics and outcomes of patients receiving a LVAD within 30 days following the diagnosis of cardiomyopathy. Patients from the ASSIST-ICD study was divided into recently and remotely diagnosed cardiomyopathy based on the time from initial diagnosis of cardiomyopathy to LVAD implantation using the cut point of 30 days. The primary end point of the study was all-cause mortality at 30-day and during follow-up. A total of 652 patients were included and followed during a median time of 9.1 (2.5 to 22.1) months. In this population, 117 (17.9%) had a recently diagnosed cardiomyopathy and had LVAD implantation after a median time of 15.0 (9.0 to 24.0) days following the diagnosis. This group of patients was significantly younger, with more ischemic cardiomyopathy, more sudden cardiac arrest (SCA) events at the time of the diagnosis and were more likely to receive temporary mechanical support before LVAD compared with the remotely diagnosed group. Postoperative in-hospital survival was similar in groups, but recently diagnosed patients had a better long-term survival after hospital discharge. SCA before LVAD and any cardiac surgery combined with LVAD implantation were identified as 2 independent predictors of postoperative mortality in recently diagnosed patients. In conclusion, rescue LVAD implantation for recently diagnosed severe cardiomyopathy is common in clinical practice. Such patients experience a relatively low postoperative mortality and have a better long-term survival compared with remotely diagnosed patients.


Assuntos
Cardiomiopatias/terapia , Coração Auxiliar , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências
7.
PLoS One ; 15(11): e0242931, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33253314

RESUMO

BACKGROUND: Chronic subclinical hemolysis is frequent in patients implanted with Left Ventricular Assist Device (LVAD) and is associated with adverse outcomes. Consequences of LVADs-induced subclinical hemolysis on kidney structure and function is currently unknown. METHODS: Thirty-three patients implanted with a Heartmate II LVAD (Abbott, Inc, Chicago IL) were retrospectively studied. Hemolysis, Acute Kidney Injury (AKI) and the evolution of estimated Glomerular Filtration Rate were analyzed. Proximal Tubulopathy (PT) groups were defined according to proteinuria, normoglycemic glycosuria, and electrolytic disorders. The Receiver Operating Characteristic (ROC) curve was used to analyze threshold of LDH values associated with PT. RESULTS: Median LDH between PT groups were statistically different, 688 IU/L [642-703] and 356 IU/L [320-494] in the "PT" and "no PT" groups, respectively p = 0.006. To determine PT group, LDH threshold > 600 IU/L was associated with a sensitivity of 85.7% (95% CI, 42.1-99.6) and a specificity of 84.6% (95% CI, 65.1-95.6). The ROC's Area Under Curve was 0.83 (95% CI, 0.68-0.98). In the "PT" group, patients had 4.2 [2.5-5.0] AKI episodes per year of exposure, versus 1.6 [0.4-3.7] in the "no PT" group, p = 0.03. A higher occurrence of AKI was associated with subsequent development of Chronic Kidney Disease (CKD) (p = 0.02) and death (p = 0.05). CONCLUSIONS: LVADs-induced subclinical hemolysis is associated with proximal tubular functional alterations, which in turn contribute to the occurrence of AKI and subsequent CKD. Owing to renal toxicity of hemolysis, measures to reduce subclinical hemolysis intensity as canula position or pump parameters should be systematically considered, as well as specific nephroprotective therapies.


Assuntos
Injúria Renal Aguda/fisiopatologia , Síndrome de Fanconi/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Injúria Renal Aguda/sangue , Injúria Renal Aguda/etiologia , Idoso , Síndrome de Fanconi/sangue , Síndrome de Fanconi/etiologia , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/etiologia , Testes Hematológicos , Hemólise/fisiologia , Humanos , Rim/metabolismo , Rim/fisiopatologia , Túbulos Renais Proximais/patologia , L-Lactato Desidrogenase/sangue , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
8.
Am J Cardiol ; 133: 81-88, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-32861423

RESUMO

We aimed at characterizing the impact of low and high body mass index (BMI) on outcomes after left-ventricular assist device (LVAD) surgery and define the predictors of mortality in patients with abnormal BMI (low/high). This study was conducted in 19 centers from 2006 to 2016. Patients were divided based on their baseline BMI into 3 groups of BMI: low (BMI ≤18.5 kg/m²); normal (BMI = 18.5 to 24.99 kg/m²) and high (BMI ≥25 kg/m²) (including overweight (BMI = 25 to 29.99 kg/m²), and obesity (BMI ≥30 Kg/m²)). Among 652 patients, 29 (4.4%), 279 (42.8%) and 344 (52.8%) had a low-, normal-, and high BMI, respectively. Patients with high BMI were significantly more likely men, with more co-morbidities and more history of ventricular/supra-ventricular arrhythmias before LVAD implantation. Patients with abnormal BMI had significantly lower survival than those with normal BMI. Notably, those with low BMI experienced the worst survival whereas overweight or obese patients had similar survival. Four predictors of mortality for LVAD candidates with abnormal BMI were defined: total bilirubin ≥16 µmol/L before LVAD, hypertension, destination therapy, and cardiac surgery with LVAD. Depending on the number of predictor per patients, those with abnormal BMI may be divided in 3 groups of 1-year mortality risk, i.e., low (0 to 1 predictor: 29% and 31%), intermediate (2 to 3 predictors, 51% and 52%, respectively), and high (4 predictors: 83%). In conclusion, LVAD recipients with abnormal BMI experience lower survival, especially underweight patients. Four predictors of mortality have been identified for LVAD population with abnormal BMI, differentiating those a low-, intermediate-, and high risks of death.


Assuntos
Índice de Massa Corporal , Insuficiência Cardíaca/terapia , Coração Auxiliar , Obesidade/complicações , Magreza/complicações , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/mortalidade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Magreza/mortalidade , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32627211

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Coração Auxiliar , Idoso , França , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
10.
Eur J Cardiothorac Surg ; 58(1): 112-120, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32298439

RESUMO

OBJECTIVES: Our goal was to provide a picture of left ventricular assist device (LVAD) activity in France between 2007 and 2016 based on the multicentric ASSIST-ICD registry. METHODS: We retrospectively collected 136 variables including in-hospital data, follow-up survival rates and adverse events from 671 LVAD recipients at 20 out of 24 LVAD implant centres in France. The average follow-up time was 1.2 years (standard deviation: 1.4); the total follow-up time was 807.5 patient-years. RESULTS: The included devices were the HeartMate II®, HeartWare LVAS® or Jarvik 2000®. The overall likelihood of being alive while on LVAD support or having a transplant (primary end point) at 1, 2, 3 and 5 years postimplantation was 65.2%, 59.7%, 55.9% and 47.7%, respectively, given a cumulative incidence of 29.2% of receiving a transplant at year 5. At implantation, 21.5% of patients were on extracorporeal life support. The overall rate of cardiogenic shock at implantation was 53%. The major complications were driveline infection (26.1%), pump pocket or cannula infection (12.6%), LVAD thrombosis (12.2%), ischaemic (12.8%) or haemorrhagic stroke (5.4%; all strokes 18.2%), non-cerebral haemorrhage (9.1%) and LVAD exchange (5.2%). The primary end point (survival) was stratified by age at surgery and by the type of device used, with inference from baseline profiles. The primary end point combined with an absence of complications (secondary end point) was also stratified by device type. CONCLUSIONS: The ASSIST-ICD registry provides a real-life picture of LVAD use in 20 of the 24 implant centres in France. Despite older average age and a higher proportion of patients chosen for destination therapy, survival rates improved compared to those in previous national registry results. This LVAD registry contrasts with other international registries because patients with implants have more severe disease, and the national policy for graft attribution is distinct. We recommend referring patients for LVAD earlier and suggest a discussion of the optimal timing of a transplant for bridged patients (more dismal results after the second year of support?).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , França/epidemiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
12.
Heart Rhythm ; 16(10): 1506-1512, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31255846

RESUMO

BACKGROUND: Ventricular arrhythmias (VAs) can occur after continuous flow left ventricular assist device (LVAD) implantation as a single arrhythmic event or as electrical storm (ES) with multiple repetitive VA episodes. OBJECTIVE: We aimed at analyzing the incidence, predictors, and clinical impact of ES in LVAD recipients. METHODS: Patients analyzed were those included in the multicenter ASSIST-ICD observational study. ES was consensually defined as occurrence of ≥3 separate episodes of sustained VAs within a 24-hour interval. RESULTS: Of 652 patients with an LVAD, 61 (9%) presented ES during a median follow-up period of 9.1 (interquartile range [IQR] 2.5-22.1) months. The first ES occurred after 17 (IQR 4.0-56.2) days post LVAD implantation, most of them during the first month after the device implantation (63%). The incidence then tended to decrease during the initial years of follow-up and increased again after the third year post LVAD implantation. History of VAs before LVAD implantation and heart failure duration > 84 months were independent predictors of ES. The occurrence of ES was associated with an increased early mortality since 20 patients (33%) died within the first 2 weeks of ES. Twenty-two patients (36.1%) presented at least 1 recurrence of ES, occurring 43.0 (IQR 8.0-69.0) days after the initial ES. Patients experiencing ES had a significantly lower 1-year survival rate than did those free from ES (log-rank, P = .039). CONCLUSION: There is a significant incidence of ES in patients with an LVAD. The short-term mortality after ES is high, and one-third of patients will die within 15 days. Whether radiofrequency ablation of arrhythmias improves outcomes would require further studies.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/mortalidade , Adulto , Fatores Etários , Idoso , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores Sexuais , Taxa de Sobrevida , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia
13.
Am Heart J ; 214: 69-76, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31174053

RESUMO

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/mortalidade , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Feminino , França/epidemiologia , Ventrículos do Coração , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco
14.
Circ Cardiovasc Interv ; 12(4): e007597, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30998397

RESUMO

BACKGROUND: The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves. METHODS AND RESULTS: Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%-85.5%) and 18.6% (95% CI, 15.3%-21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%-2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%-8.4%) and 4.2% (95% CI, 2.9%-5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%-1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses. CONCLUSIONS: The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 4(9): 1166-1175, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30236390

RESUMO

OBJECTIVES: This study aimed to evaluate the incidence, clinical impact, and predictors of late ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients aiming to clarify implantable cardioverter-defibrillator (ICD) indications. BACKGROUND: The arrhythmic risk and need for ICD in patients implanted with an LVAD are not very well known. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Late VAs were defined as sustained ventricular tachycardia or fibrillation occurring >30 days post-LVAD implantation, without acute reversible cause and requiring appropriate ICD therapy, external electrical shock, or medical therapy. RESULTS: Among 659 LVAD recipients, 494 (median 58.9 years of age; mean left ventricular ejection fraction 20.7 ± 7.4%; 73.1% HeartMate II, 18.6% HeartWare, 8.3% Jarvik 2000) were discharged alive from hospital and included in the final analysis. Late VAs occurred in 133 (26.9%) patients. Multivariable analysis identified 6 independent predictors of late VAs: VAs before LVAD implantation, atrial fibrillation before LVAD implantation, idiopathic etiology of the cardiomyopathy, heart failure duration >12 months, early VAs (<30 days post-LVAD), and no angiotensin-converting enzyme inhibitors during follow-up. The "VT-LVAD score" was created, identifying 4 risk groups: low (score 0 to 1), intermediate (score 2 to 4), high (score 5 to 6), and very high (score 7 to 10). The rates of VAs at 1 year were 0.0%, 8.0%, 31.0% and 55.0%, respectively. CONCLUSIONS: Late VAs are common after LVAD implantation. The VT-LVAD score may help to identify patients at risk of late VAs and guide ICD indications in previously nonimplanted patients. (Determination of Risk Factors of Ventricular Arrhythmias [VAs] after implantation of continuous flow left ventricular assist device with continuous flow left ventricular assist device [CF-LVAD] [ASSIST-ICD]; NCT02873169).


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Coração Auxiliar/efeitos adversos , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
16.
EuroIntervention ; 14(3): e264-e271, 2018 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-29599103

RESUMO

AIMS: Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. METHODS AND RESULTS: All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. CONCLUSIONS: Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Consenso , Humanos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
17.
Surg Radiol Anat ; 40(8): 911-916, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29289988

RESUMO

PURPOSE: Microsurgical reconstruction in a vessel-depleted neck is a challenge due to the lack of reliable vessels in or nearby the host site. The use of the internal thoracic pedicle (ITP) by rib section or sparring is a limited option due to the small length of the pedicle of some flaps. However, in cardiac surgery, the internal thoracic artery (ITA) is widely used for myocardial revascularization, providing a long and versatile pedicle. We aimed at determining precise anatomical bases for the use of the ITP, approached by sternotomy and rerouted in the neck, as recipient vessels for free-flap facial reconstructions. METHODS: We performed a descriptive single centre anatomical study on 20 formalin-embalmed cadavers. The ITP was harvested on both sides from the emergence of the artery under the brachiocephalic vein to its terminal division. The level reached by the ITP in the cervicofacial area was described. Distal arterial and venous diameters, pedicle length and other parameters were measured. RESULTS: In at least 85% of the cases, the ITP reached the mandibular angle. The mean diameter at the distal extremity for the ITA was 2.36 ± 0.15, and 2.48 ± 0.19 mm for the committing vein. The mean length of the ITP was 177.3 mm. CONCLUSION: Rerouting the ITP towards the cervicofacial area could provide a reliable pedicle for free-flap reconstructions in patients with a vessel-depleted neck but it should be limited to selected patients. This novel solution for situations where current techniques are unfeasible warrants further clinical research.


Assuntos
Retalhos de Tecido Biológico/irrigação sanguínea , Neoplasias de Cabeça e Pescoço/cirurgia , Artéria Torácica Interna/anatomia & histologia , Microcirurgia/métodos , Procedimentos de Cirurgia Plástica/métodos , Anastomose Cirúrgica , Cadáver , Face/irrigação sanguínea , Face/cirurgia , Feminino , Retalhos de Tecido Biológico/transplante , Humanos , Masculino , Artéria Torácica Interna/cirurgia , Pescoço/irrigação sanguínea , Pescoço/cirurgia , Esternotomia
18.
JACC Cardiovasc Interv ; 10(23): 2426-2436, 2017 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-29217006

RESUMO

OBJECTIVES: The aim of this study was to assess the incidence, prognostic impact, and predictive factors of readmission for congestive heart failure (CHF) in patients with severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR is indicated in patients with severe symptomatic aortic stenosis in whom surgery is considered high risk or is contraindicated. Readmission for CHF after TAVR remains a challenge, and data on prognostic and predictive factors are lacking. METHODS: All patients who underwent TAVR from January 2010 to December 2014 were included. Follow-up was achieved for at least 1 year and included clinical and echocardiographic data. Readmission for CHF was analyzed retrospectively. RESULTS: This study included 546 patients, 534 (97.8%) of whom were implanted with balloon-expandable valves preferentially via the transfemoral approach in 87.8% of cases. After 1 year, 285 patients (52.2%) had been readmitted at least once, 132 (24.1%) for CHF. Patients readmitted for CHF had an increased risk for death (p < 0.0001) and cardiac death (p < 0.0001) compared with those not readmitted for CHF. On multivariate analysis, aortic mean gradient (hazard ratio [HR]: 0.88; 95% confidence interval [CI]: 0.79 to 0.99; p = 0.03), post-procedural blood transfusion (HR: 2.27; 95% CI: 1.13 to 5.56; p = 0.009), severe post-procedural pulmonary hypertension (HR: 1.04; 95% CI: 1.00 to 1.07; p < 0.0001), and left atrial diameter (HR: 1.47; 95% CI: 1.08 to 2.01; p = 0.02) were independently associated with CHF readmission at 1 year. CONCLUSIONS: Readmission for CHF after TAVR was frequent and was strongly associated with 1-year mortality. Low gradient, persistent pulmonary hypertension, left atrial dilatation, and transfusions were predictive of readmission for CHF.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/epidemiologia , Readmissão do Paciente , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Causas de Morte , Distribuição de Qui-Quadrado , Ecocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão Pulmonar/epidemiologia , Hipertensão Pulmonar/fisiopatologia , Incidência , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
19.
Ann Thorac Surg ; 103(4): 1262-1268, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27743637

RESUMO

BACKGROUND: Current recommendations of antithrombotic therapy for HeartMate II (HMII) patients include the use of both an anticoagulant and an antiplatelet agent. Because bleeding is still the most frequent adverse event, the TRACE (STudy of Reduced Anti-Coagulation/Anti-platelet Therapy in Patients with the HeartMatE II) study was initiated to evaluate the incidence of adverse events in HMII patients on reduced antithrombotic (RT) therapy. METHODS: HMII patients (n = 101) from nine centers were enrolled in the European arm of TRACE and were managed on a single anticoagulant (vitamin K antagonist) with no antiplatelet agents. An analysis of bleeding and thrombotic adverse events from all 101 patients with 2-year follow-up after initiation of RT therapy is reported here. RESULTS: Median age was 56 years (range, 18 to 72 years), 93% were men, 70% had an Interagency Registry for Mechanically Assisted Circulatory Support profile 1 to 3, and 82% received the HMII as a bridge to transplantation. Ninety-two percent were placed on RT therapy as a center standard of care or due to physician preference and 6% as a response to bleeding. Median HMII support duration on RT therapy was 25 months (range, 1 to 93 months). Median international normalized ratio was 2.31 [quartile 1 to quartile 3: 2.07 to 2.60]. At 2 years, freedom from bleeding, ischemic stroke, hemorrhagic stroke, and pump thrombosis after initiation of RT therapy was 81% ± 6%, 96% ± 2%, 94% ± 3%, and 94% ± 3%, respectively. CONCLUSIONS: The 2-year analysis of the observational European TRACE study suggests that managing HMII patients with a vitamin K antagonist with a target international normalized ratio of 2.3 without antiplatelet therapy may help to reduce the incidence of major bleeding without increasing the risk of thromboembolic events, including ischemic stroke and pump thrombosis.


Assuntos
Anticoagulantes/uso terapêutico , Insuficiência Cardíaca/terapia , Coração Auxiliar , Inibidores da Agregação Plaquetária/uso terapêutico , Hemorragia Pós-Operatória/epidemiologia , Adolescente , Adulto , Idoso , Estudos de Coortes , Europa (Continente) , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
20.
Arch Cardiovasc Dis ; 109(8-9): 457-64, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27342810

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is recommended in patients with severe aortic stenosis that is either inoperable or at high-risk for surgical valve replacement. AIMS: To evaluate trends in the feasibility and safety of transfemoral TAVI over the past 4 years. METHODS: Between 2010 and 2013, all consecutive patients undergoing TAVI in our institution were included in a prospective registry. Population characteristics and 30-day and 1-year outcomes were analysed. Outcomes were classified according to the Valve Academic Research Consortium-2. RESULTS: Overall, 429 patients underwent TAVI; transfemoral access was used in 368 (85.7%). The proportion of patients treated via a transfemoral approach increased (70.1% to 89.9%; P<0.0001) and the use of prior balloon aortic valvuloplasty decreased (44.7% to 11.2%; P<0.0001). The mean logistic EuroSCORE decreased significantly from 19.4±10.9% to 15.8±8.7% (P=0.01). The 30-day mortality rate did not change significantly (6.4% vs. 5.6%; P=0.99). Similarly, rates of major vascular complications (12.8% vs. 15.4%; P=0.87) and stroke (2.1% vs. 1.4%; P=0.75) remained unchanged. Mean length of stay after TAVI decreased significantly from 8.9±11.3 days to 4.8±4.7 days (P=0.002) and 72 (50.3%) patients were discharged early in 2013. One-year survival increased significantly from 81.0% to 94.4% (P=0.03). CONCLUSIONS: Over the past 4 years, TAVI has been increasingly performed using a transfemoral approach. Treated patients are at lower-risk with less co-morbidity. Thirty-day mortality and complications remained unchanged, but length of stay after TAVI and 1-year mortality decreased dramatically.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Medição de Risco , Substituição da Valva Aórtica Transcateter/tendências , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Aortografia , Causas de Morte/tendências , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...