Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(15)2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39124050

RESUMO

To improve the performance of roller bearing fault diagnosis, this paper proposes an algorithm based on subtraction average-based optimizer (SABO), variational mode decomposition (VMD), and weighted Manhattan-K nearest neighbor (WMH-KNN). Initially, the SABO algorithm uses a composite objective function, including permutation entropy and mutual information entropy, to optimize the input parameters of VMD. Subsequently, the optimized VMD is used to decompose the signal to obtain the optimal decomposition characteristics and the corresponding intrinsic mode function (IMF). Finally, the weighted Manhattan function (WMH) is used to enhance the classification distance of the KNN algorithm, and WMH-KNN is used for fault diagnosis based on the optimized IMF features. The performance of the SABO-VMD and WMH-KNN models is verified through two experimental cases and compared with traditional methods. The results show that the accuracy of motor-bearing fault diagnosis is significantly improved, reaching 97.22% in Dataset 1, 98.33% in Dataset 2, and 99.2% in Dataset 3. Compared with traditional methods, the proposed method significantly reduces the false positive rate.

2.
Biosens Bioelectron ; 261: 116475, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38852324

RESUMO

Rapid and accurate identification of tumor boundaries is critical for the cure of glioma, but it is difficult due to the invasive nature of glioma cells. This paper aimed to explore a rapid diagnostic strategy based on a label-free surface-enhanced Raman scattering (SERS) technique for the quantitative detection of glioma cell proportion intraoperatively. With silver nanoparticles as substrate, an in-depth SERS analysis was performed on simulated clinical samples containing normal brain tissue and different concentrations of patient-derived glioma cells. The results revealed two universal characteristic peaks of 655 and 717 cm-1, which strongly correlated with glioma cell proportion regardless of individual differences. Based on the intensity ratio of the two peaks, a ratiometric SERS strategy for the quantification of glioma cells was established by employing an artificial neuron network model and a polynomial regression model. Such a strategy accurately estimated the proportion of glioma cells in simulated clinical samples (R2 = 0.98) and frozen samples (R2 = 0.85). More importantly, it accurately facilitated the delineation of tumor margins in freshly obtained samples. Taken together, this SERS-based method ensured a rapid and more detailed identification of tumor margins during surgical resection, which could be beneficial for intraoperative decision-making and pathological evaluation.


Assuntos
Neoplasias Encefálicas , Glioma , Nanopartículas Metálicas , Prata , Análise Espectral Raman , Glioma/cirurgia , Glioma/patologia , Glioma/diagnóstico por imagem , Humanos , Análise Espectral Raman/métodos , Nanopartículas Metálicas/química , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Prata/química , Técnicas Biossensoriais/métodos
3.
Biomed Opt Express ; 15(2): 524-539, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38404320

RESUMO

In photoacoustic tomography (PAT), imaging speed is an essential metric that is restricted by the pulse laser repetition rate and the number of channels on the data acquisition card (DAQ). Reconstructing the initial sound pressure distribution with fewer elements can significantly reduce hardware costs and back-end acquisition pressure. However, undersampling will result in artefacts in the photoacoustic image, degrading its quality. Dictionary learning (DL) has been utilised for various image reconstruction techniques, but they disregard the uniformity of pixels in overlapping blocks. Therefore, we propose a compressive sensing (CS) reconstruction algorithm for circular array PAT based on gradient domain convolutional sparse coding (CSCGR). A small number of non-zero signal positions in the sparsely encoded feature map are used as partially known support (PKS) in the reconstruction procedure. The CS-CSCGR-PKS-based reconstruction algorithm can use fewer ultrasound transducers for signal acquisition while maintaining image fidelity. We demonstrated the effectiveness of this algorithm in sparse imaging through imaging experiments on the mouse torso, brain, and human fingers. Reducing the number of array elements while ensuring imaging quality effectively reduces equipment hardware costs and improves imaging speed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA