Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhonghua Er Ke Za Zhi ; 51(2): 126-9, 2013 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-23527979

RESUMO

OBJECTIVE: To evaluate the indications, methodology and results of the transcatheter closure of patent ductus arteriosus (PDA) with the new Amplatzer Duct Occluder II (ADO-II). METHOD: Totally 51 patients underwent transcatheter closure of PDA with the new ADO-II. The devices were delivered by 4F or 5F sheath through arterial or venous side respectively. The descending aorta angiography and transthoracic echocardiography was performed to evaluate the device position, residual shunt and complications caused by the device during and after implantation. RESULT: Forty-nine patients had successful transcatheter closure of the PDA without significant residual shunts and artery obstruction during the short-term follow-up. One patient received the ADO-II dislodgment and first generation ADO re-implantation for the obvious descending aortal obstruction caused by ADO-II. Another patient had the ADO-II dislodgment and left pulmonary artery shaping surgery, because the ADO-II implantation led to obstruction of the left pulmonary artery. Both the obstructions in these two patients were ameliorated afterwards. CONCLUSION: The transcatheter closure using the ADO-II is safe and effective for the non-window type PDA with a small size.


Assuntos
Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Dispositivo para Oclusão Septal , Adolescente , Aortografia , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Humanos , Lactente , Masculino , Desenho de Prótese , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/etiologia , Embolia Pulmonar/cirurgia , Reoperação , Resultado do Tratamento
2.
Pediatr Cardiol ; 33(8): 1348-54, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22592443

RESUMO

The aim of this study was to investigate the degree of myocardial injury following catheter radiofrequency (RF) ablation (RFA) or cryoablation and its clinical significance in children and patients with congenital heart disease. Cardiac troponin T (cTnT) or cardiac troponin I (cTnI), creatine kinase (CK), and its cardiac isoenzyme MB (CK-MB) were measured in 269 patients who underwent catheter ablation (216 RFA, 53 cryoablation) just before the procedure and again 6 hours after the end of the procedure. Follow-up studies included echocardiography and 12 lead electrocardiographics (ECGs). No clinical, ECG, nor ECG signs of ischemia were detected. Biomarkers were increased in 57.7-75.5 %. A linear regression analysis illustrated the ablation target site and the number of RF applications as a function of higher cTnI and cTnT levels, with the maximum increase due to ventricular ablation and higher numbers of RF applications. No significant difference in cTnT levels after RFA or cryoablation were observed for AV nodal reentrant tachycardia procedures and no significant differences were observed after nonirrigated tip or irrigated tip RFA in atrial wall or ventricular wall ablation. Elevations in both troponin T and troponin I levels were commonly observed after ablation, especially in ventricular wall ablation as well as with increasing numbers of radiofrequency applications. However, unlike in patients with acute coronary syndrome, these elevated levels had no specific significance. Reference values for each ablation target site were proposed in order to potentially detect additional subclinical injuries to the coronary arteries.


Assuntos
Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Cardiopatias Congênitas/cirurgia , Traumatismos Cardíacos/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Biomarcadores/sangue , Análise Química do Sangue , Criança , Pré-Escolar , Creatina Quinase/sangue , Creatina Quinase Forma MB/sangue , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Lactente , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Troponina I/sangue , Troponina T/sangue
3.
Zhonghua Xin Xue Guan Bing Za Zhi ; 40(10): 817-20, 2012 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-23302666

RESUMO

OBJECTIVES: To evaluate the feasibility and efficacy of transcatheter closure of perimembranous ventricular septal defects (pmVSD) with aneurysmatic formation and muscular ventricular septal defects (mVSD) with Amplatzer duct occluder II. METHODS: This retrospective analysis included 48 cases received transcatheter closure of pmVSD aneurysmatic formation or mVSD from February 2011 to March 2012 in our hospital (42 pmVSD with aneurysmatic formation and 6 mVSD). Median age was 5.2 years (range: 1.8 - 15 years), and median weight was 20.2 kg (range: 12 - 44 kg). Amplatzer duct occluder II was selected depending on the condition of ventricular septal defect. The device was implanted by antegrade or retrograde approach. Complications such as residual shunt, valvular regurgitation and arrhythmia were evaluated by echocardiography or angiography. Median follow-up was 9.5 months (range: 1 - 13 months). RESULTS: The mean ratio of pulmonary (Qp) to systemic (Qs) blood flow was 1.35 ± 0.15 before transcatheter closure. The diameter of exit hole of ventricular septal defects was (2.46 ± 0.53) mm measured by transthoracic echocardiography, and (2.35 ± 0.40) mm by angiography. Successful implantation of the device was achieved in 46 patients (96%) and unsuccessful in two cases due to acute aortic insufficiency. Forty-two (92%) patients were closed successfully, and trivial residual leak was evidenced in four patients and remained unchanged during follow-up. One patient with mVSD still had trivial residual shunt at 6 months post procedure. New trivial tricuspid insufficiency was observed in 1 patient (2.1%) during follow-up. Two patients developed procedural related left anterior fascicular block and remained unchanged during follow-up. CONCLUSIONS: pmVSD with aneurysm and mVSD could be successfully treated with Amplatzer duct occluder II. However, the long waist and large disc of the device could interfere with tricuspid valve function and cause tricuspid insufficiency.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Comunicação Interventricular/cirurgia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Dispositivo para Oclusão Septal , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...