Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nature ; 625(7994): 253-258, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38200292

RESUMO

Neutron stars and stellar-mass black holes are the remnants of massive star explosions1. Most massive stars reside in close binary systems2, and the interplay between the companion star and the newly formed compact object has been theoretically explored3, but signatures for binarity or evidence for the formation of a compact object during a supernova explosion are still lacking. Here we report a stripped-envelope supernova, SN 2022jli, which shows 12.4-day periodic undulations during the declining light curve. Narrow Hα emission is detected in late-time spectra with concordant periodic velocity shifts, probably arising from hydrogen gas stripped from a companion and accreted onto the compact remnant. A new Fermi-LAT γ-ray source is temporally and positionally consistent with SN 2022jli. The observed properties of SN 2022jli, including periodic undulations in the optical light curve, coherent Hα emission shifting and evidence for association with a γ-ray source, point to the explosion of a massive star in a binary system leaving behind a bound compact remnant. Mass accretion from the companion star onto the compact object powers the light curve of the supernova and generates the γ-ray emission.

2.
Biomech Model Mechanobiol ; 21(5): 1549-1560, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35867283

RESUMO

Percutaneous coronary intervention (PCI) has become the primary treatment for patients with coronary heart disease because of its minimally invasive nature and high efficiency. Anatomical studies have shown that most coronary vessels gradually shrink, and the vessels gradually become thinner from the proximal to the distal end. In this paper, the effects of different stent expansion methods on the mechanical and hemodynamic behaviors of coronary vessels and stents were studied. To perform a structural-mechanical analysis of stent implantation, the coronary vessels with branching vessels and the coronary vessels with large bending curvature are selected. The two characteristic structures are implanted in equal diameter expansion mode and conical expansion mode, and the stress and mechanical behaviors of the coronary vessels and stents are analyzed. The results of the structural-mechanical analysis showed that the mechanical behaviors and fatigue performance of the cobalt-chromium alloy stent were good, and the different expansion modes of the stent had little effect on the fatigue performance of the stent. However, the equal diameter expansion mode increased distal coronary artery stress and the risk of vascular injury. The computational fluid dynamics analysis results showed that different stent expansion methods had varied effects on coronary vessel hemodynamics and that the wall shear stress distribution of conical stent expansion is more uniform compared with equal diameter expansion. Additionally, the vortex phenomenon is not apparent, the blood flow velocity is slightly increased, the hydrodynamic environment is more reasonable, and the risk of coronary artery injury is reduced.


Assuntos
Vasos Coronários , Intervenção Coronária Percutânea , Humanos , Hidrodinâmica , Intervenção Coronária Percutânea/efeitos adversos , Stents , Estresse Mecânico , Fadiga/etiologia
3.
Front Physiol ; 13: 904453, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35634139

RESUMO

Transcatheter aortic valve replacement (TAVR) is a minimally invasive surgical treatment for heart valve disease. At present, personalized TAVR valves are not available for some patients. This study adopts the fluid-structure interaction (FSI) model of the research object that has a three-disc leaflet form and structural design in the valve leaflet area. The valve opening shape, orifice area, stress-strain, and distribution of hemodynamic flow and pressure were compared under the condition of equal contact area between valve and blood. The FSI method was used to simulate the complex three dimensional characteristics of the flow field more accurately around the valve after TAVR stent implantation. Three personalized stent systems were established to study the performance of the leaflet design based on computational fluid dynamics. By comparing the different leaflet geometries, the maximum stress on leaflets and stents of model B was relatively reduced, which effectively improved the reliability of the stent design. Such valve design also causes the opening area of the valve leaflet to increase and the low-velocity area of the flow field to decrease during the working process of the valve, thus reducing the possibility of thrombosis. These findings can underpin breakthroughs in product design, and provide important theoretical support and technical guidance for clinical research.

4.
Proc Inst Mech Eng H ; : 9544119221076946, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35102787

RESUMO

V-shaped braid stents (VBSs), as highly retrievable and flexible nitinol stents, are extensively applied in endovascular diseases. They also cause less damage to vessel wall compared to tube-cutting stents. However, poor performance of VBS or suboptimal operation can give rise to unwanted clinical situations such as thrombosis and intimal hyperplasia. Therefore, research on designing factors affecting the performance of these devices is of great significance. Furthermore, simulation of stenting process can help designers understand the interactions of stents and vessel wall to reduce time to market. Thus, finite element analysis (FEA) and bench test are performed taking into account both designing factors and stenting process of VBS, including development of parametric modeling tool, research on the relationships among structural parameters and radial force, exploration of the interactions of VBS and vessel wall and pulsating load effect. This research was performed using a commercial solver Abaqus/standard with a user material subroutine (UMAT/nitinol). Structural parameters of VBS, unit-cell height and wire diameter have significant impacts on radial force, unit-cell number has slight influence on radial force, and arc diameter has almost negligible impact on radial force. Without pulsatile load, maximum stress and strain always occur in arc position; however, in pulsatile load, maximum stress and strain are gradually transformed to strut position. The stress created near vessel wall and VBS interface is higher than interaction stress due to pulsating load. The obtained result provided valuable information on the structural design of stents as well as the effects of stent on vessel wall and that vessel wall on stent deformation.Graphical abstract[Formula: see text].

5.
Phys Rev Lett ; 117(5): 051101, 2016 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-27517761

RESUMO

In this Letter, we report the observational constraints on the Hu-Sawicki f(R) theory derived from weak lensing peak abundances, which are closely related to the mass function of massive halos. In comparison with studies using optical or x-ray clusters of galaxies, weak lensing peak analyses have the advantages of not relying on mass-baryonic observable calibrations. With observations from the Canada-France-Hawaii-Telescope Lensing Survey, our peak analyses give rise to a tight constraint on the model parameter |f_{R0}| for n=1. The 95% C.L. is log_{10}|f_{R0}|<-4.82 given WMAP9 priors on (Ω_{m}, A_{s}). With Planck15 priors, the corresponding result is log_{10}|f_{R0}|<-5.16.

6.
PLoS One ; 9(11): e110278, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25365310

RESUMO

This study established a numerical model to investigate the degradation mechanism and behavior of bioabsorbable cardiovascular stents. In order to generate the constitutive degradation material model, the degradation characteristics were characterized with user-defined field variables. The radial strength bench test and analysis were used to verify the material model. In order to validate the numerical degradation model, in vitro bench test and in vivo implantation studies were conducted under physiological and normal conditions. The results showed that six months of degradation had not influenced the thermodynamic properties and mechanical integrity of the stent while the molecular weight of the stents implanted in the in vivo and in vitro models had decreased to 61.8% and 68.5% respectively after six month's implantation. It was also found that the degradation rate, critical locations and changes in diameter of the stents in the numerical model were in good consistency in both in vivo and in vitro studies. It implies that the numerical degradation model could provide useful physical insights and prediction of the stent degradation behavior and evaluate, to some extent, the in-vivo performance of the stent. This model could eventually be used for design and optimization of bioabsorbable stent.


Assuntos
Implantes Absorvíveis , Modelos Teóricos , Stents , Animais , Humanos , Teste de Materiais , Suínos , Fatores de Tempo
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 38(3): 161-4, 176, 2014 May.
Artigo em Chinês | MEDLINE | ID: mdl-25241506

RESUMO

Magnesium stents have gained increasing interest as an ideal stent of future intervention. In order to study the deformation behavior of magnesium alloy stents in the interventional treatment, the finite element method was used to analysis the effects of different crimp and expansion dimensions on the mechanical properties (maximum stress, radial recoil rate, longitudinal shortening rate and radial strength). The results showed that crimping and expanding have a minimal influence on the stent radial strength. When the expansion size is same, the maximum equivalent stress and recoil rate decrease with the crimp size. When the crimp size is same, in contrast with the radial recoil rate, the maximum equivalent stress and longitudinal shortening rate increase with the expansion size. In addition the paper verified the radial strength-radial displacement curve obtained by FEM. Results are basically consistent, indicating the finite element method can efficiently provide researchers with reliable, high-quality design.


Assuntos
Análise de Elementos Finitos , Magnésio , Stents , Ligas
8.
Zhongguo Yi Liao Qi Xie Za Zhi ; 38(2): 98-101, 2014 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-24941770

RESUMO

The finite element method was used for simulating the mechanical performance and fatigue safety of three different structures of Nitinol stent. According to the actual situation, after proposing reasonable assumptions and simplification, the geometry model and finite element model establishment, material mode selection and boundary condition setting are completed. The strain and fatigue life of different stent edges wide (omega) or strut angle (theta) are computed. The result can provide a valuable reference for the optimal design of stent.


Assuntos
Ligas , Análise de Elementos Finitos , Desenho de Prótese , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...