Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mov Disord ; 37(9): 1807-1816, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36054272

RESUMO

BACKGROUND: The diagnostic criteria for Parkinson's disease (PD) remain complex, which is especially problematic for nonmovement disorder experts. A test is required to establish a diagnosis of PD with improved accuracy and reproducibility. OBJECTIVE: The study aimed to investigate the sensitivity and specificity of tests using sniffer dogs to diagnose PD. METHODS: A prospective, diagnostic case-control study was conducted in four tertiary medical centers in China to evaluate the accuracy of sniffer dogs to distinguish between 109 clinically established medicated patients with PD, 654 subjects without PD, 37 drug-naïve patients with PD, and 185 non-PD controls. The primary outcomes were sensitivity and specificity of sniffer dog's identification. RESULTS: In the study with patients who were medicated, when two or all three sniffer dogs yielded positive detection results in a sample tested, the index test sensitivity, specificity, and positive and negative likelihood ratios were 91% (95% CI: 84%-96%), 95% (95% CI: 93%-97%), and 19.16 (95% CI: 13.52-27.16) and 0.10 (95% CI: 0.05-0.17), respectively. The corresponding sensitivity, specificity, and positive and negative likelihood ratios in patients who were drug-naïve were 89% (95% CI: 75%-96%), 86% (95% CI: 81%-91%), and 6.6 (95% CI: 4.51-9.66) and 0.13 (95% CI: 0.05-0.32), respectively. CONCLUSIONS: Tests using sniffer dogs may be a useful, noninvasive, fast, and cost-effective method to identify patients with PD in community screening and health prevention checkups as well as in neurological practice. © 2022 International Parkinson and Movement Disorder Society.


Assuntos
Doença de Parkinson , Animais , Estudos de Casos e Controles , Cães , Humanos , Doença de Parkinson/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cães Trabalhadores
2.
Front Psychol ; 13: 952001, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35967675

RESUMO

The role of social environmental factors on student academic achievement has been conceptualized from the perspective of the ecological system theory. In the present study, a strengths-based approach derived from the theory of positive youth development was adopted to explore the two favorable aspects of proximal social environments, including parents' emotional support and school cooperation climate, and to examine how these two factors influence the academic performance among Chinese senior-secondary vocational school students. Participants were 1,940 students (55.4% male) who took part in the Programme for International Student Assessment (PISA) 2018 test from four regions in China. The students completed the questionnaires to assess parents' emotional support, school cooperation climate, school belonging, and academic performance. By adopting the structural equation model, the results revealed that school belonging fully mediates the association between parents' emotional support and academic scores, and the association between school cooperation climate and academic scores. In addition, multiple group comparison analyses showed there were some gender differences in the relationships between school cooperation climate and academic performance. The practical significance of the influence of parental support and school cooperation climate on student academic achievement was also discussed.

3.
J Am Assoc Lab Anim Sci ; 61(3): 248-251, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35393007

RESUMO

Most in vivo animal research and breeding using mice and rats in China takes place in facilities under barrier conditions. Items being moved across the barrier are typically disinfected using UV radiation in a transfer hatch. However, the time periods necessary for this disinfection technique are inefficient, and disinfection is frequently incomplete, especially if concealed surfaces are present. The current study used a newly developed transfer hatch incorporating both UV and ozone disinfection to examine disinfection efficacy against 4 bacteria species (Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter baumannii). Disinfection trials used UV and ozone, applied separately and in combination, for up to 30 min. Separate and combined treatments were also tested with a UV barrier. We found that if UV radiation has direct contact with surfaces, it is an efficient disinfection method. However, where surfaces are concealed by a UV barrier, UV radiation performs relatively poorly. The results of this study indicate that a combination of UV and ozone produces the most effective disinfection and is markedly quicker than current disinfection times for UV applied on its own. This novel transfer hatch design therefore allows more complete and efficient disinfection, improves workflow, and reduces barrier breaches by pathogens that may affect animal health and welfare and compromise research outcomes.


Assuntos
Desinfetantes , Ozônio , Animais , Bactérias , Desinfetantes/farmacologia , Desinfecção/métodos , Camundongos , Ozônio/farmacologia , Ratos , Raios Ultravioleta
4.
PLoS One ; 17(4): e0266223, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35385528

RESUMO

BACKGROUND: The incineration and burying of the soiled bedding of laboratory animals, as well as using detergents to treat their feces, is hazardous to the environment. This highlights the need for an alternative, environmentally friendly solution for the treatment of the waste of laboratory animal facilities. This study aims to evaluate the efficacy of ozone disinfection of the soiled bedding and feces of laboratory animals. METHODS: Two grams of soiled beddings were randomly sampled from the cages of mice and rats. These samples were mixed in a beaker with 40ml saline. Ozone was piped into the beaker at a concentration of 500mg/h. Samples were taken from the beaker at time 0min, 30min, 45min and 60min after ozone treatment for microbiological culturing in an incubator for 48h. Colony form unit of each plate (CFU/plate) at each time point were counted, the mean CFU/plate at each time point after ozone treatment were compared with that present at time zero. Feces of rabbits and dogs were treated and pathogens were counted the similar way as that of bedding of the mice and rats; samples being taken at 0min, 15min, 30min, 45min and 60min. RESULTS: Pathogens were observed in beddings of both mice and rats as well as in feces of rabbits and dogs. Ozone treatment for 30min killed more than 93% of pathogens in the bedding of the two rodent species and 60min of treatment killed over 99% of pathogens. Treatment of rabbit and dog feces for 30min killed over 96% pathogens present, and 60min's treatment killed nearly all the pathogens. Both Gram positive and Gram negative pathogens were sensitive to ozone treatment. CONCLUSION: Ozone treatment of bedding and feces is an effective and environment friendly way to deal with the waste of animal facilities, saving energy and potentially enabling their reuse as fertilizer.


Assuntos
Ozônio , Doenças dos Roedores , Animais , Animais de Laboratório , Roupas de Cama, Mesa e Banho , Cães , Fezes , Abrigo para Animais , Ozônio/farmacologia , Coelhos , Ratos , Doenças dos Roedores/microbiologia
5.
J Photochem Photobiol B ; 207: 111869, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32278270

RESUMO

An animal laboratory in a teaching hospital is a possible cause of cross infection. We aimed to assess the infection control in our animal laboratory and evaluate the disinfectant effects of a portable pulsed xenon ultraviolet (PX-UV) machine. Samples were taken from the surface of research tables, other high touch places, such as doorknobs, weighing scales, and handles of trolleys, and from air in the barrier system pre- and post-manual cleaning and post-PX-UV disinfection. The bacteria types were identified. We found that routine manual cleaning significantly reduced bacterial colony form unit (CFU)/cm2 (P = .02), and the median of CFU/cm2 reduced from 0.5 pre-cleaning to zero post-cleaning. PX-UV disinfection also significantly reduced residual bacterial counts (P = .002), with the highest counts 10 pre-PX-UV disinfection and 1 afterwards. Without manual cleaning, PX-UV disinfected surfaces significantly (P < .001), median count 6 pre-PX-UV disinfection and zero afterwards. PX-UV significantly reduced bacterial colony counts in the air with the median count falling from 6 to zero (P < .001). Some of the 21 species of pathogens we identified in the current study are pathogenic, resistant to antibiotics, and able to cause nosocomial infections and zoonosis. PX-UV reduced counts of most of the pathogens. PX-UV is an effective agent against these pathogens.


Assuntos
Bactérias/efeitos da radiação , Infecção Hospitalar/prevenção & controle , Desinfecção/instrumentação , Desinfecção/métodos , Raios Ultravioleta , Xenônio/química , Animais , China , Contagem de Colônia Microbiana , Computadores de Mão , Relação Dose-Resposta à Radiação , Microbiologia Ambiental , Hospitais , Hospitais de Ensino , Humanos , Laboratórios
6.
Photodiagnosis Photodyn Ther ; 27: 137-140, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31152875

RESUMO

BACKGROUND AND OBJECTIVES: Non-thermal atmospheric plasma treatment and pulsed xenon ultraviolet (PX-UV) treatment are widely used in disinfection of hospital environments. However, their effectiveness has not been evaluated against a comparator. The objective of this study is to evaluate their effectiveness in the disinfection of pathogens in the air in hospital blood sampling rooms. METHODS: Samples were taken from the air before and after disinfection with PX-UV and non-thermal atmospheric plasma. We counted bacterial colonies and identified the types of bacteria. RESULTS: Non-thermal plasma treatment significantly reduced bacterial counts in the air, the median reduced from 1 before treatment to zero afterwards (p = 0.03). PX-UV treatment also significantly reduced bacterial counts in the air (p = 0.01), the median reduced from 1.5 before treatment to zero afterwards. Pathogens identified in the current study include nosocomial bacteria, such as Staphylococcus aureus, Staphylococcus epidermidis, and yeast. CONCLUSION: Disinfection of blood sampling sites is essential in a health service department. The efficiency of PX-UV and non-thermal atmospheric plasma treatment are comparable in air disinfection.


Assuntos
Bactérias Aeróbias/efeitos da radiação , Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Gases em Plasma , Raios Ultravioleta , Xenônio , Bactérias Aeróbias/isolamento & purificação , Carga Bacteriana , Hospitais , Viabilidade Microbiana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...