Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Plast Reconstr Aesthet Surg ; 68(5): 622-31, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25892285

RESUMO

BACKGROUND: The advent of three-dimensional stereo-photogrammetry in recent years has vastly helped the craniomaxillofacial field improve in terms of preoperative and intraoperative decision making. With regard to the auricle though, there is paucity of research as to the application of this promising technology. METHODS: A total of 20 normal adult ears were included in this study. Thirteen anthropometric measurements were taken, twice by two plastic surgeons using direct measurement (DM) and through images captured via 3dMD™. The purpose was to compare the reliability of measurements involving the two instruments. RESULTS: The overall mean absolute differences (MADs) of all ear anthropometries of DM and 3dMD™ were 0.52 mm (range: 0.28-0.72 mm) and 0.27 mm (range: 0.15-0.53 mm), respectively, and the grand mean relative error magnitudes (REMs) were 2.85% (range: 1.01-5.99%) and 1.57% (range: 0.48-3.62%), respectively, across observers. Thus, the precision of all ear anthropometries across observers was high in both methods, but the precision of 3dMD was better than DM irrespective of observers. In addition, the MADs were less than a millimeter across all measurements. CONCLUSION: The application of three-dimensional technology in microtia surgery for both template production and soft tissue analysis leads to improved planning and satisfactory results with fewer complications. We believe that with further refinement and enhancement, the use of this innovation will pave the way for prefabricated, individualized autologous or biocompatible alloplastic implantable frameworks based on an accurate mirror image of each patient's normal ear in unilateral cases and in bilateral cases, appropriately sized.


Assuntos
Antropometria/instrumentação , Microtia Congênita/diagnóstico , Microtia Congênita/cirurgia , Diagnóstico por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Fotogrametria/instrumentação , Adolescente , Adulto , Análise de Variância , Antropometria/métodos , Criança , Diagnóstico por Computador/métodos , Pavilhão Auricular/anormalidades , Pavilhão Auricular/anatomia & histologia , Pavilhão Auricular/patologia , Pavilhão Auricular/cirurgia , Humanos , Imageamento Tridimensional/métodos , Masculino , Fotogrametria/métodos , Procedimentos de Cirurgia Plástica/métodos , Reprodutibilidade dos Testes , Retalhos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA