Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Anal Biochem ; 687: 115429, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38113981

RESUMO

Microcystin-producing cyanobacterial blooms are a global issue threatening drinking water supplies and recreation on lakes and beaches. Direct measurement of microcystins is the only way to ensure waters have concentrations below guideline concentrations; however, analyzing water for microcystins takes several hours to days to obtain data. We tested LightDeck Diagnostics' bead beater cell lysis and two versions of the quantification system designed to give microcystin concentrations within 20 min and compared it to the standard freeze-thaw cycle lysis method and ELISA quantification. The bead beater lyser was only 30 % effective at extracting microcystins compared to freeze-thaw. When considering freeze-thaw samples analyzed in 2021, there was good agreement between ELISA and LightDeck version 2 (n = 152; R2 = 0.868), but the LightDeck slightly underestimated microcystins (slope of 0.862). However, we found poor relationships between LightDeck version 2 and ELISA in 2022 (n = 49, slopes 0.60 to 1.6; R2 < 0.6) and LightDeck version 1 (slope = 1.77 but also a high number of less than quantifiable concentrations). After the quantification issues are resolved, combining the LightDeck system with an already-proven rapid lysis method (such as microwaving) will allow beach managers and water treatment operators to make quicker, well-informed decisions.


Assuntos
Técnicas Biossensoriais , Cianobactérias , Microcistinas/análise , Microcistinas/metabolismo , Proliferação Nociva de Algas , Lagos/análise
2.
SLAS Technol ; 28(6): 442-448, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37844868

RESUMO

Rapid and accurate measurements of immune protein markers are essential for diagnosis and treatment in all clinical settings. The recent pandemic has revealed a stark need for developing new tools and assays that could be rapidly used in diverse settings and provide useful information to clinicians. Here, we describe the development and test application of a novel one-step CRP/IP-10 duplex assay for the LightDeck platform capable of delivering reproducible and accurate measurements in under eight minutes. We used the optimized assay to measure CRP and IP-10 levels in human blood and serum samples from healthy, SARS-CoV-2 (COVID-19) positive, and influenza-like illness (ILI) presenting patients. Our results agreed with previously published analyte levels and enabled us to make statistically significant comparisons relevant to multiple clinical parameters. Our duplex assay is a simple and powerful tool for aiding prognostic decision-making in diverse settings.


Assuntos
COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Biomarcadores , Quimiocina CXCL10/sangue , Quimiocina CXCL10/química , COVID-19/diagnóstico , SARS-CoV-2 , Proteína C-Reativa/química
3.
Environ Sci Technol ; 52(20): 11691-11698, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30208702

RESUMO

Harmful algal blooms in freshwater systems are increasingly common and present threats to drinking water systems, recreational waters, and ecosystems. A highly innovative simple to use, portable biosensor system (MBio) for the rapid and simultaneous detection of multiple cyanobacterial toxins in freshwater is demonstrated. The system utilizes a novel planar waveguide optical sensor that delivers quantitative fluorescent competitive immunoassay results in a disposable cartridge. Data are presented for the world's first duplex microcystin (MC)/cylindrospermopsin (CYN) assay cartridge using a combination of fluorophore-conjugated monoclonal antibodies as detector molecules. The on-cartridge detection limits of 20% inhibitory concentration (IC20) was 0.4 µg/L for MC and 0.7 µg/L for CYN. MC assay coverage of eight important MC congeners was demonstrated. Validation using 45 natural lake water samples from Colorado and Lake Erie showed quantitative correlation with commercially available laboratory-based enzyme linked immunosorbent assays. A novel cell lysis module was demonstrated using cyanobacteria cultures. Results show equivalent or better performance than the gold-standard but more tedious 3× freeze-thaw method, with >90% cell lysis for laboratory cultures. The MBio system holds promise as a versatile tool for multiplexed field-based cyanotoxin detection, with future analyte expansion including saxitoxin, anatoxin-a, and marine biotoxins.


Assuntos
Técnicas Biossensoriais , Microcistinas , Colorado , Ecossistema , Água Doce , Proliferação Nociva de Algas
4.
Health Sci Rep ; 1(9): e75, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30623098

RESUMO

BACKGROUND AND AIM: Influenza diagnostics play a critical role informing in clinical management decisions and defining the global epidemiology of the disease to support public health responses. Use of influenza diagnostics within most low-income and middle-income countries remains limited, including in the Philippines, where they are currently used only for epidemiologic surveillance. The aim of this study was to define key considerations, including product characteristics, which may influence future adoption, uptake, and integration of influenza diagnostics into public and private clinical settings in this emerging Asian market. METHODS: Our study was conducted using a convenience sample of public and private hospital laboratories in Metro Manila. A usability assessment was conducted that included interviews with decision-makers and direct observation of laboratory end users using 2 platforms representative of emerging diagnostic products: (1) a point-of-care antigen-based rapid immunoassay diagnostic test paired with a reader and (2) a molecular diagnostic platform intended for decentralized use. Data were analyzed to assess user errors and device failure modes with each platform and to determine key considerations related to product adoption and uptake. RESULTS: The most difficult test step for most users on both platforms involved sample preparation. When deciding to adopt a new test, priority product attributes include performance, potential volume of demand from clinicians, equipment cost, and ease of use. Demand for new tests is likely going to be driven by clinicians, and policies and guidelines will be needed to support the introduction of new products. CONCLUSION: Adoption of influenza diagnostics in Metro Manila is feasible but will require affordable products capable of satisfying needs for use in both epidemiologic surveillance and clinical management.

5.
Clin Infect Dis ; 64(7): 947-955, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28362937

RESUMO

BACKGROUND: Development of rapid diagnostic tests for tuberculosis is a global priority. A whole proteome screen identified Mycobacterium tuberculosis antigens associated with serological responses in tuberculosis patients. We used World Health Organization (WHO) target product profile (TPP) criteria for a detection test and triage test to evaluate these antigens. METHODS: Consecutive patients presenting to microscopy centers and district hospitals in Peru and to outpatient clinics at a tuberculosis reference center in Vietnam were recruited. We tested blood samples from 755 HIV-uninfected adults with presumptive pulmonary tuberculosis to measure IgG antibody responses to 57 M. tuberculosis antigens using a field-based multiplexed serological assay and a 132-antigen bead-based reference assay. We evaluated single antigen performance and models of all possible 3-antigen combinations and multiantigen combinations. RESULTS: Three-antigen and multiantigen models performed similarly and were superior to single antigens. With specificity set at 90% for a detection test, the best sensitivity of a 3-antigen model was 35% (95% confidence interval [CI], 31-40). With sensitivity set at 85% for a triage test, the specificity of the best 3-antigen model was 34% (95% CI, 29-40). The reference assay also did not meet study targets. Antigen performance differed significantly between the study sites for 7/22 of the best-performing antigens. CONCLUSIONS: Although M. tuberculosis antigens were recognized by the IgG response during tuberculosis, no single antigen or multiantigen set performance approached WHO TPP criteria for clinical utility among HIV-uninfected adults with presumed tuberculosis in high-volume, urban settings in tuberculosis-endemic countries.


Assuntos
Antígenos de Bactérias/imunologia , Imunoglobulina G/imunologia , Mycobacterium tuberculosis/imunologia , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/imunologia , Adolescente , Adulto , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Peru , Reprodutibilidade dos Testes , Testes Sorológicos/métodos , Testes Sorológicos/normas , Tuberculose Pulmonar/epidemiologia , Adulto Jovem
6.
Cytometry B Clin Cytom ; 92(6): 451-455, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-25917935

RESUMO

BACKGROUND: Point-of-care (POC) CD4 T-cell counting is increasingly recognized as providing improved linkage-to-care during management of HIV infection, particularly in resource-limited settings where disease burden is highest. This study evaluated prototype POC CD4 T-cell counters from MBio Diagnostics in the context of low CD4 count, hospitalized patients in Mozambique. This study measured system performance when presented with challenging, low count samples from HIV/AIDS patients with acute illnesses resulting in hospitalization. METHODS: Forty whole blood samples were collected from donors on the medical service at Maputo Central Hospital and absolute CD4 counts were generated on the MBio CD4 system and a reference laboratory using flow cytometry. RESULTS: The mean and median CD4 counts by the flow cytometry reference were 173 and 80 cells/µL, respectively. Correlation between the MBio CD4 System and the reference was good. Bland-Altman analysis showed a mean bias of +15 cells/µL (+9 to +21 cells/µL, 95% CI), and limits of agreement of -47 to 77 cells/µL. For samples with counts >100 cells/µL (N = 14), the mean coefficient of variation was 7.3%. For samples with counts <50 cells/µL, mean absolute bias of replicate samples was 4.8 cells/µL. When two MBio readers were compared, Bland-Altman bias was -4 cells/µL (-13 to +6 cells/µL, 95% CI), and limits of agreement of -63 and +55 cells/µL. CONCLUSIONS: The MBio System holds promise as a POC system for quantitation of CD4 T cells in resource-limited settings given system throughput (80-100 cartridges/day), design simplicity, and ease-of-use. © 2015 International Clinical Cytometry Society.


Assuntos
Contagem de Linfócito CD4/instrumentação , Linfócitos T CD4-Positivos/imunologia , Citometria de Fluxo/instrumentação , Infecções por HIV/diagnóstico , Imunofenotipagem/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Complexo CD3/imunologia , Linfócitos T CD4-Positivos/virologia , Estudos de Casos e Controles , Computadores de Mão/economia , Computadores de Mão/provisão & distribuição , Países em Desenvolvimento , Citometria de Fluxo/economia , Infecções por HIV/imunologia , Infecções por HIV/virologia , Humanos , Imunofenotipagem/instrumentação , Subpopulações de Linfócitos/imunologia , Subpopulações de Linfócitos/virologia , Aplicativos Móveis/economia , Aplicativos Móveis/provisão & distribuição , Moçambique , Padrões de Referência , Reprodutibilidade dos Testes
7.
PLoS One ; 11(9): e0163616, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27669509

RESUMO

Diagnosis of KSHV-infected individuals remains a challenge. KSHV prevalence is high in several populations with high prevalence of HIV, leading to increased risk of development of Kaposi's sarcoma (KS). While current assays are reliable for detecting antibodies to KSHV, none are routinely utilized to identify individuals with KSHV infection and thus at increased risk for KS due to assay complexity, lack of access to testing, and cost, particularly in resource-limited settings. Here we describe the addition of KSHV proteins LANA and K8.1 to a previously evaluated HIV/co-infection multiplexed fluorescence immunoassay system. This study demonstrates assay performance by measuring antibody reactivity for KSHV and HIV-1 in a collection of clinical specimens from patients with biopsy-proven KS and sourced negative controls. The KSHV assay correctly identified 155 of 164 plasma samples from patients with biopsy-proven KS and 85 of 93 KSHV antibody (Ab)-negative samples for a sensitivity of 95.1% and specificity of 91.4%. Assay performance for HIV-1 detection was also assessed with 100% agreement with independently verified HIV-1 Ab-positive and Ab-negative samples. These results demonstrate good sensitivity and specificity for detection of antibody to KSHV antigens, and demonstrate the potential for multiplexed co-infection testing in resource-limited settings to identify those at increased risk for HIV-1-related complications.

8.
Essays Biochem ; 60(1): 49-58, 2016 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-27365035

RESUMO

Increasing occurrences of harmful algal blooms (HABs) in the ocean are a major concern for countries around the globe, and with strong links between HABs and climate change and eutrophication, the occurrences are only set to increase. Of particular concern with regard to HABs is the presence of toxin-producing algae. Six major marine biotoxin groups are associated with HABs. Ingestion of such toxins via contaminated shellfish, fish, or other potential vectors, can lead to intoxication syndromes with moderate to severe symptoms, including death in extreme cases. There are also major economic implications associated with the diverse effects of marine biotoxins and HABs. Thus, effective monitoring programmes are required to manage and mitigate their detrimental global effect. However, currently legislated detection methods are labour-intensive, expensive and relatively slow. The growing field of biosensor diagnostic devices is an exciting area that has the potential to produce robust, easy-to-use, cost-effective, rapid and accurate detection methods for marine biotoxins and HABs. This review discusses recently developed biosensor assays that target marine biotoxins and their microbial producers, both in harvested fish/shellfish samples and in the open ocean. The effective deployment of such biosensor platforms could address the pressing need for improved monitoring of HABs and marine biotoxins, and could help to reduce their global economic impact.


Assuntos
Técnicas Biossensoriais/métodos , Toxinas Marinhas/análise , Proliferação Nociva de Algas
9.
Anal Bioanal Chem ; 407(15): 4459-72, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25701420

RESUMO

Antimicrobial residues found to be present in milk can have both health and economic impacts. For these reasons, the widespread routine testing of milk is required. Due to delays with sample handling and test scheduling, laboratory-based tests are not always suited for making decisions about raw material intake and product release, especially when samples require shipping to a central testing facility. Therefore, rapid on-site screening tests that can produce results within a matter of minutes are required to facilitate rapid intake and product release processes. Such tests must be simple for use by non-technical staff. There is increasing momentum towards the development and implementation of multiplexing tests that can detect a range of important antimicrobial residues simultaneously. A simple in situ multiplexed planar waveguide device that can simultaneously detect chloramphenicol, streptomycin and desfuroylceftiofur in raw dairy milk, without sample preparation, has been developed. Samples are simply mixed with antibody prior to an aliquot being passed through the detection cartridge for 5 min before reading on a field-deployable portable instrument. Multiplexed calibration curves were produced in both buffer and raw milk. Buffer curves, for chloramphenicol, streptomycin and desfuroylceftiofur, showed linear ranges (inhibitory concentration (IC)20-IC80) of 0.1-0.9, 3-129 and 12-26 ng/ml, whilst linear range in milk was 0.13-0.74, 11-376 and 2-12 ng/ml, respectively, thus meeting European legislated concentration requirements for both chloramphenicol and streptomycin, in milk, without the need for any sample preparation. Desfuroylceftiofur-contaminated samples require only simple sample dilution to bring positive samples within the range of quantification. Assay repeatability and reproducibility were lower than 12 coefficient of variation (%CV), whilst blank raw milk samples (n = 9) showed repeatability ranging between 4.2 and 8.1%CV when measured on all three calibration curves. Graphical Abstract MBio SnapEsi reader and cartridge.


Assuntos
Anti-Infecciosos/análise , Cefalosporinas/análise , Cloranfenicol/análise , Contaminação de Alimentos/análise , Leite/química , Estreptomicina/análise , Animais , Antibacterianos/análise , Bovinos , Análise de Alimentos/economia , Análise de Alimentos/métodos , Limite de Detecção , Reprodutibilidade dos Testes , Fatores de Tempo
10.
Biosens Bioelectron ; 67: 708-14, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25459059

RESUMO

Microcystins are a major group of cyanobacterial heptapeptide toxins found in freshwater and brackish environments. There is currently an urgent requirement for highly-sensitive, rapid and in-expensive detection methodologies for these toxins. A novel single chain fragment variable (scFv) fragment was generated and is the first known report of a recombinant anti-microcystin avian antibody. In a surface plasmon resonance-based immunoassay, the antibody fragment displayed cross-reactivity with seven microcystin congeners (microcystin-leucine-arginine (MC-LR) 100%, microcystin-tyrosine-arginine (MC-YR) 79.7%, microcystin-leucine-alanine (MC-LA) 74.8%, microcystin-leucine-phenylalanine (MC-LF) 67.5%, microcystin-leucine-tryptophan (MC-LW) 63.7%, microcystin-arginine-arginine (MC-RR) 60.1% and nodularin (Nod) 69.3%, % cross reactivity). Following directed molecular evolution of the parental clone the resultant affinity-enhanced antibody fragment was applied in an optimized fluorescence immunoassay on a planar waveguide detection system. This novel immuno-sensing format can detect free microcystin-LR with a functional limit of detection of 0.19 ng mL(-1)and a detection range of 0.21-5.9 ng mL(-1). The assay is highly reproducible (displaying percentage coefficients of variance below 8% for intra-day assays and below 11% for inter-day assays), utilizes an inexpensive cartridge system with low reagent volumes and can be completed in less than twenty minutes.


Assuntos
Técnicas Biossensoriais , Imunoensaio , Microcistinas/isolamento & purificação , Cianobactérias/química , Água Doce/análise , Fragmentos de Imunoglobulinas/química , Fragmentos de Imunoglobulinas/imunologia , Toxinas Marinhas , Microcistinas/química , Proteínas Recombinantes/química , Proteínas Recombinantes/imunologia , Ressonância de Plasmônio de Superfície
11.
Anal Chim Acta ; 769: 108-13, 2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23498128

RESUMO

The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10 min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78 ng mL(-1) and the CCß to be 1 ng mL(-1). Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R(2)=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1 ng mL(-1), and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1 ng mL(-1). This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1 µg L(-1). This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.


Assuntos
Cianobactérias/metabolismo , Água Doce/análise , Imunoensaio , Microcistinas/análise , Anticorpos Monoclonais/imunologia , Cromatografia Líquida de Alta Pressão , Microcistinas/imunologia , Microcystis/crescimento & desenvolvimento , Microcystis/metabolismo , Espectrometria de Massas em Tandem
12.
Biosens Bioelectron ; 41: 691-7, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23102433

RESUMO

Marine dinoflagellates of the genera Alexandrium are well known producers of the potent neurotoxic paralytic shellfish toxins that can enter the food web and ultimately present a serious risk to public health in addition to causing huge economic losses. Direct coastal monitoring of Alexandrium spp. can provide early warning of potential shellfish contamination and risks to consumers and so a rapid, sensitive, portable and easy-to-use assay has been developed for this purpose using an innovative planar waveguide device. The disposable planar waveguide is comprised of a transparent substrate onto which an array of toxin-protein conjugates is deposited, assembled in a cartridge allowing the introduction of sample, and detection reagents. The competitive assay format uses a high affinity antibody to paralytic shellfish toxins with a detection signal generated via a fluorescently labelled secondary antibody. The waveguide cartridge is analysed by a simple reader device and results are displayed on a laptop computer. Assay speed has been optimised to enable measurement within 15 min. A rapid, portable sample preparation technique was developed for Alexandrium spp. in seawater to ensure analysis was completed within a short period of time. The assay was validated and the LOD and CCß were determined as 12 pg/mL and 20 pg/mL respectively with an intra-assay CV of 11.3% at the CCß and an average recovery of 106%. The highly innovative assay was proven to accurately detect toxin presence in algae sampled from the US and European waters at an unprecedented cell density of 10 cells/L.


Assuntos
Técnicas Biossensoriais/instrumentação , Monitoramento Ambiental/instrumentação , Eucariotos/química , Toxinas Marinhas/análise , Frutos do Mar/análise , Espectrometria de Fluorescência/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Immunol Methods ; 387(1-2): 107-13, 2013 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-23063690

RESUMO

The measurement of the absolute CD4 T-cell count is critical in the initial evaluation and staging of HIV-infected persons, yet access to this technology remains limited in many low resource settings where disease burden is highest. Here we evaluate the performance of a prototype point-of-care device (POC) to quantify CD4 T cells from MBio Diagnostics, Inc. Whole blood samples, both venous and capillary (finger stick), were collected from known HIV-infected participants at the University of California, San Diego Antiviral Research Center, and tested using the MBio system and conventional flow cytometry. A total of 94 venipuncture and 52 capillary samples were processed and statistical analyses included comparison to flow cytometry results. For the venipuncture samples, Bland-Altman analysis resulted in a mean bias of -10 cells/µL (-23 to +3 cells/µL, 95% CI), and limits of agreement (LOA) of -132 and +112 cells/µL. For the capillary samples, Bland-Altman resulted in a mean bias of -4 cells/µL (-31 to +23 cells/µL, 95% CL), and LOA of -195 and +186 cells/µL. For the San Diego study cohort, the prototype MBio system showed negligible quantitative bias relative to flow cytometry. Higher variability was observed in the capillary samples relative to venipuncture, but system precision for both capillary and venipuncture samples was good. There was also close agreement between results from the same participant when tested with two different systems, different operators and different locations. This preliminary evaluation suggests that the MBio CD4 device holds promise as a POC system for quantitation of CD4 T cells in limited-resource settings.


Assuntos
Contagem de Linfócito CD4/instrumentação , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Contagem de Linfócito CD4/métodos , Feminino , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
14.
J Clin Microbiol ; 49(10): 3584-90, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21865431

RESUMO

Diagnosis of opportunistic infections in HIV-infected individuals remains a major public health challenge, particularly in resource-limited settings. Here, we describe a rapid diagnostic system that delivers a panel of serologic immunoassay results using a single drop of blood, serum, or plasma. The system consists of disposable cartridges and a simple reader instrument, based on an innovative implementation of planar waveguide imaging technology. The cartridge incorporates a microarray of recombinant antigens and antibody controls in a fluidic channel, providing multiple parallel fluorescence immunoassay results for a single sample. This study demonstrates system performance by delivering antibody (Ab) reactivity results simultaneously for multiple antigens of HIV-1, Treponema pallidum (syphilis), and hepatitis C virus (HCV) in a collection of clinical serum, plasma, and whole-blood samples. By plotting antibody reactivity (fluorescence intensity) for known positive and negative samples, empirical reactivity cutoff values were defined. The HIV-1 assay shows 100% agreement with known seroreactivity for a collection of 82 HIV Ab-positive and 142 HIV Ab-negative samples, including multiple samples with HCV and syphilis coinfection. The treponema-specific syphilis assay correctly identifies 67 of 68 T. pallidum Ab-positive and 100 of 102 T. pallidum Ab-negative samples, and the HCV assay correctly identifies 59 of 60 HCV Ab-positive and 120 of 121 HCV Ab-negative samples. Multiplexed assay performance for whole-blood samples is also demonstrated. The ability to diagnose HIV and opportunistic infections simultaneously at the point of care should lead to more effective therapy decisions and improved linkage to care.


Assuntos
Sorodiagnóstico da AIDS/métodos , Infecções Oportunistas Relacionadas com a AIDS/diagnóstico , Técnicas de Laboratório Clínico/métodos , Coinfecção/diagnóstico , Hepatite C/diagnóstico , Sífilis/diagnóstico , Humanos , Imunoensaio/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Fatores de Tempo
15.
Expert Rev Mol Diagn ; 10(5): 565-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20629505

RESUMO

The 2010 HIV Diagnostics Conference brought together approximately 260 representatives from public health laboratories, test manufacturers and federal agencies for a series of test method and technology presentations, as well as policy discussions related to HIV screening in the USA. The meeting was particularly substantive in the context of moving toward a consensus laboratory testing algorithm that capitalizes on the improved sensitivities and turnaround times associated with newer technologies. This article provides a brief overview of several meeting topics, including point-of-care testing algorithms, fourth-generation immunoassays, recency testing and new technologies.


Assuntos
Algoritmos , Técnicas de Laboratório Clínico , Congressos como Assunto , Infecções por HIV/diagnóstico , Humanos , Programas de Rastreamento , Saúde Pública
16.
Methods Mol Biol ; 381: 37-57, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17984513

RESUMO

In almost all microarray technologies that are currently used, some type of surface chemistry serves as the interface between immobilized biomolecules and the solid support. Factors such as probe loading, spot morphology, and signal-to-noise ratio are all intimately linked to surface chemistry. Surface chemistry also significantly impacts important performance parameters such as three-dimensional structure of the immobilized biomolecules and nonspecific assay backgrounds. Here, an overview of the major types of surface chemistries currently used in printed microarrays is provided, with an emphasis on standard glass slide formats. The first part of this chapter focuses on DNA array surface chemistries, including both commercially fabricated and custom-made arrays. The second part of the chapter focuses on emerging protein, peptide, and carbohydrate array techniques. The intent is to provide the molecular biology researcher and bio-analytical or diagnostic specialist with a guide to the surface chemistry state-of-the-art for established and emerging array technologies.


Assuntos
Análise em Microsséries/métodos , Análise de Sequência com Séries de Oligonucleotídeos , Análise Serial de Proteínas , Propriedades de Superfície
17.
Biomaterials ; 28(28): 4105-12, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17573108

RESUMO

This study examined bacterial adhesion to a new multi-component cross-linked poly(ethylene glycol)-based polymer coating that can be applied by spin-coating or spraying onto diverse biomaterials. Adhesion of five clinically isolated bacterial strains involved in biomaterial-centered infections were studied in a parallel-plate flow chamber at different shear rates and after exposure of the coating to different physiological fluids. The new chemistry inhibits non-specific biomolecular and cell binding interactions. Relative to glass, the coating reduced adhesion of all strains used in this study by more than 80%, with the exception of Escherichia coli O2K2. Reductions in adhesion of Staphylococcus epidermidis 3,399 persisted beyond 168h exposure of the coatings to phosphate buffered saline or urine, but not after exposure to protein-rich fluids as saliva and blood plasma, despite evidence from X-ray photoelectron spectroscopy that the coating integrity was not affected by exposure to these fluids. We conclude that this new coating chemistry provides beneficial properties to prevent or hinder bacterial adhesion and colonization in applications where low protein-conditions prevail.


Assuntos
Bactérias/metabolismo , Aderência Bacteriana/fisiologia , Materiais Revestidos Biocompatíveis/química , Polietilenoglicóis/química , Materiais Revestidos Biocompatíveis/metabolismo , Teste de Materiais , Estrutura Molecular , Polietilenoglicóis/metabolismo , Resistência ao Cisalhamento , Propriedades de Superfície
18.
Chem Mater ; 19(18): 4405-4414, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18815622

RESUMO

This paper describes a new bioassay surface chemistry that effectively inhibits non-specific biomolecular and cell binding interactions, while providing a capacity for specific immobilization of desired biomolecules. Poly(ethylene glycol) (PEG) as the primary component in nonfouling film chemistry is well-established, but the multicomponent formulation described here is unique in that it (1) is applied in a single, reproducible, solution-based coating step; (2) can be applied to diverse substrate materials without the use of special primers; and (3) is readily functionalized to provide specific attachment chemistries. Surface analysis data are presented, detailing surface roughness, polymer film thickness, and film chemistry. Protein non-specific binding assays demonstrate significant inhibition of serum, fibrinogen, and lysozyme adsorption to coated glass, indium tin oxide, and tissue culture polystyrene dishes. Inhibition of S. aureus and K. pneumoniae microbial adhesion in a microfluidic flow cell, and inhibition of fibroblast cell adhesion from serum-based cell culture is shown. Effective functionalization of the coating is demonstrated by directing fibroblast adhesion to polymer surfaces activated with an RGD peptide. Batch-to-batch reproducibility data are included. The in situ cross-linked PEG-based coating chemistry is unique in its formulation, and its surface properties are attractive for a broad range of in vitro bioassay applications.

19.
Nat Mater ; 3(4): 239-43, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15034562

RESUMO

Many biominerals are laminated such that crystal shape or habit changes from layer to layer thus yielding exquisitely designed composite materials with tightly controlled properties. Although lamination in biominerals is usually performed using peptides and proteins, here we introduce a new strategy by which sequential addition or depletion of inorganic trivalent ions in a supersaturated solution can be used to switch the surface morphology of calcium oxalate monohydrate (COM) back and forth, resulting in either the growth of flat crystalline sheets or of nanostructures oriented perpendicular to the surface. We propose that the occupation of a Ca(2+) site by Eu(3+) ion switches the orientation of the COM unit cell. The need to compensate the third charge forces coordination of Eu(3+) to an additional oxalate ion ((-)OOC-COO(-)) in an orientation that is not compatible with the initial unit cell. This mechanism of switching the orientation of the unit cell is unique, as it does not involve the use of expensive and thermally labile biomolecules. Suggestions of how to extend this strategy to engineer non-biological nanocomposites are given.


Assuntos
Físico-Química/métodos , Cristalização , Íons , Oxalatos/química , Cálcio/química , Oxalato de Cálcio/química , Európio/química , Microscopia de Força Atômica , Minerais/química , Modelos Moleculares , Oxigênio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...