Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Sci Rep ; 11(1): 9370, 2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33931715

RESUMO

The [Formula: see text] and [Formula: see text] transitions in Li-like carbon ions stored and cooled at a velocity of [Formula: see text] in the experimental storage ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry has been resolved and agreement between experiment and theory is confirmed.

3.
Sci Rep ; 11(1): 7338, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33795713

RESUMO

We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.

4.
Opt Express ; 20(20): 21992-2000, 2012 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23037349

RESUMO

We report the first short-pulse amplification results to several hundred millijoule energies in ceramic Yb:LuAG. We have demonstrated ns-pulse output from a diode-pumped Yb:LuAG amplifier at a maximum energy of 580 mJ and a peak optical-to-optical efficiency of 28% at 550 mJ. In cavity dumped operation of a nanosecond oscillator we obtained 1 mJ at up to 100 Hz repetition rate. A gain bandwidth of 5.4 nm was achieved at room temperature by measuring the small-signal single-pass gain. Furthermore, we compared our results with Yb:YAG within the same amplifier system.


Assuntos
Amplificadores Eletrônicos , Cerâmica/química , Lasers de Estado Sólido , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento
5.
Opt Express ; 17(22): 19887-93, 2009 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-19997211

RESUMO

Yb(3+)-doped gain media offer favorable properties for diode-pumped laser amplifiers for high-energy ns-pulses. To reach high optical-to-optical conversion efficiencies at room temperature however, very high and often impractical fluences are required both for pumping and extraction. Low temperature operation offers a solution, but the required cryogenic cooling systems add considerable complexity, bulkiness and cost. Multi-passing both pump and extraction beams through the gain medium is an alternative approach to overcome efficiency limitations at room temperature. In this article we present numerical and experimental results to this effect.We demonstrated ns-pulse output from a diode-pumped Yb:YAG amplifier at an energy of 566 mJ and an optical-to-optical efficiency of 20%, which is almost a doubling of the efficiency achieved with ns-lasers employing Yb(3+)-doped gain media at this energy level.


Assuntos
Alumínio , Ítrio , Desenho Assistido por Computador , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA