Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(12)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38928634

RESUMO

Ultrasound elastography is widely used to assess tissue stiffness for lesion characterization, including differentiation between benign and malignant lesions. This study focuses on the use of elastography in the male pelvis, including the prostate, testicles, and rectum, by comparing elastography types (shear wave and strain). This article provides a summary of the existing literature on the use of elastography in the male pelvic region and outlines the clinical perspective. Ultrasound elastography is a good technique for evaluating and monitoring lesions in the male pelvic region.

2.
J Med Imaging Radiat Sci ; 54(4): 692-698, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37838500

RESUMO

BACKGROUND: Ultrasonography measurement of the testicles and subsequent calculation of the testicular volume is recommended as a part of a standard scrotal ultrasound examination. The interobserver variability of testicular volume measurement has implications for surgical recommendations. Therefore, this study aimed to investigate the interobserver variability in the measurement of testicular volume. METHODS: Interobserver variability was established by comparing testicular measurements performed by two observers on the same patient during the same clinical appointment. The observers were blinded to each other's measurements. Testicular volume was calculated using the Lambert formula: length x width x height x 0.71. A total of three observers, A, B and C, participated in the study. The observers had between 4 to 20 years' experience with scrotal ultrasound examinations. RESULTS: In total, 24 patients' were included (48 testicles). The patient´s mean age was 43 years (range 19-75 years). The overall mean right testicular volume was 19.8 ml (range 7.3-31.6 ml), and the left was 20.1 ml (range 7.1-36.1 ml). The interclass correlation coefficient (ICC) between observer A and B was excellent (ICC= 0.98, CI:0.92-0.99), between observer A and C, was excellent (ICC=0.91, CI: 0.77-0.97) and between B and C good (ICC=0.82, CI:0.51-0.93). CONCLUSION: Variability in estimating testicular volume is low, with interobserver agreement ranging from good to excellent. Ultrasound provides a highly reproducible tool to determine testicular volume.


Assuntos
Testículo , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Variações Dependentes do Observador , Ultrassonografia , Testículo/diagnóstico por imagem
3.
Cancers (Basel) ; 16(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38201571

RESUMO

PURPOSE: To assess the use of quantitative diffusion-weighted MRI (DW-MRI) as a diagnostic imaging biomarker in differentiating between benign colon adenoma, early, and advanced cancer of the colon, as well as predicting lymph node involvement, and finally comparing mucinous-producing colon cancer with adenomas and non-mucinous colon cancer. METHOD: Patients with a confirmed tumor on colonoscopy were eligible for inclusion in this study. Using a 3.0 Tesla MRI machine, the main tumor mean apparent diffusion coefficient (mADC) was obtained. Surgically resected tumor specimens served as an endpoint, except in mucinous colon cancers, which were classified based on T2 images. RESULTS: A total of 152 patients were included in the study population. The mean age was 71 years. A statistically significant mADC mean difference of -282 × 10-6 mm2/s [-419--144 95% CI, p < 0.001] was found between colon adenomas and early colon cancer, with an AUC of 0.80 [0.68-0.93 95% CI] and an optimal cut off value of 1018 × 10-6 mm2/s. Only a small statistically significant difference (p = 0.039) in mADC was found between benign tumors and mucinous colon cancer. We found no statistical difference in mADC mean values between early and advanced colon cancer, and between colon cancer with and without lymph node involvement. CONCLUSION: Quantitative DW-MRI is potentially useful for determining whether a colonic tumor is benign or malignant. Mucinous colon cancer shows less diffusion restriction when compared to non-mucinous colon cancer, a potential pitfall.

4.
Diagnostics (Basel) ; 12(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36140566

RESUMO

Purpose: To investigate the diagnostic performance of endorectal ultrasound (ERUS), shear-wave elastography (SWE), and magnetic resonance imaging (MRI) in patients with a complex rectal adenoma or an early rectal cancer, i.e., T1 or T2 adenocarcinoma in a clinical setting, and to evaluate the association between SWE and stromal fraction (SF) and apparent diffusion coefficient (ADC) and SF. Method: This prospective study included patients undergoing ERUS and SWE for a rectal tumor subsequently confirmed by histopathology to be an adenoma or a T1 or T2 adenocarcinoma. The accuracy of the imaging methods was assessed by comparing the T category as determined by ERUS and MRI with histopathology, which served as the gold standard. SF was assessed on surgical specimens. Results: A total of 86 patients were included. Of these, 62 patients had adenomas and 24 patients had carcinomas, of which 11 were T1 tumors and 13 were T2 tumors. ERUS and MRI yielded sensitivity, specificity, and accuracy of 0.79 and 0.73, 0.95 and 0.90, and 0.86 and 0.78, respectively, for discrimination between benign and malignant lesions. The area under the receiver operating characteristics curve for SWE was 0.88, and with a cut-off value of 40 kPa the sensitivity, specificity, and accuracy were 0.79, 0.89, and 0.86, respectively. There was a positive correlation between SF and SWE with a p-value of <0.001 and a negative correlation between SF and ADC with a p-value of 0.011. Conclusion: Both ERUS and MRI classified T categories with a high accuracy; however, ERUS classified more adenomas correctly than MRI. In this small population, SWE could differentiate an adenoma from early carcinoma. SF was correlated with both SWE and ADC, as increasing SF tended to yield higher SWE and lower ADC values.

5.
Cancers (Basel) ; 14(11)2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35681613

RESUMO

BACKGROUND: Endorectal ultrasound (ERUS) is an important tool when evaluating complex rectal adenomas and rectal cancer, and the accuracy is improved by adding elastography measurements. A high interobserver agreement is imperative in clinical practice. Therefore, the aim of this study was to evaluate interobserver agreement assessed on real-time images. Additionally, we investigated the intra- and interobserver agreement between experienced and inexperienced observers. MATERIALS AND METHODS: We prospectively included patients referred to an ERUS at the Department of Radiology with a complex rectal polyp or suspected rectal malignancy. Two operators independently scanned each patient in turn. Furthermore, four observers assessed previously obtained images using three different methods for placing the region of interest (ROI). Three months later, the four observers reassessed the images to assess intraobserver variability. RESULTS: A total of 19 patients were included for live assessment. Agreement of tumor classification was substantial for T stage (kappa: 0.86) and fair for N stage (kappa: 0.73), with an absolute agreement for T and N stages of 84% and 89%, respectively. Agreement of SWE was good for Emean (ICC 0.94, 95% CI 0.86-0.98) and fair for Emax (ICC 0.85, 95% CI 0.66-0.94). Intra- and interobserver agreement between inexperienced and experienced observers showed good to excellent agreement with all ROI methods. CONCLUSION: Interobserver agreement is high in SWE when performed in a clinical setting. We found the best agreement using the mean value of several ROIs. Intra- and interobserver agreement was high regardless of operator experience.

6.
Curr Oncol ; 29(2): 837-847, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-35200570

RESUMO

In general, magnetic resonance (MR) diffusion-weighted imaging (DWI) has shown potential in clinical settings. In testicles parenchyma, the DW imaging helps differentiate and characterize benign from malignant lesions. Placement and size of the region of interest (ROI) may affect the ADC value. Therefore, the aim of this study was to investigate the intra- and interobserver variability in testicular tumors when measuring ADC using various types of regions of interest (ROI). Two observers performed the ADC measurements in testicular lesions based on three ROI methods: (1) whole volume, (2) round, and (3) small sample groups. Intra- and interobserver variability was analyzed for all ROI methods using intraclass correlation coefficients (ICC) and bland-altman plots. The two observers performed the measurements twice, three months apart. A total of 26 malignant testicle tumors were included. Interobserver agreement was excellent in tumor length (ICC = 0.98) and tumor width (ICC = 0.98). In addition, intraobserver agreement was excellent in tumor length (ICC = 0.98) and tumor width (ICC = 0.99). The whole volume interobserver agreement in the first reading was excellent (ICC = 0.93). Round ADC had an excellent (ICC = 0.93) and fair (ICC = 0.58) interobserver agreement, in the first and second reading, respectively. Interobserver agreement in ADC small ROIs was good (ICC = 0.87), and good (ICC = 0.78), in the first and second reading, respectively. Intraobserver agreement varied from fair, good to excellent agreement. The ROI method showed varying inter- and intraobserver agreement in ADC measurement. Using multiple small ROI conceded the highest interobserver variability, and, thus, the whole volume or round seem to be the preferable methods.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Testiculares , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Neoplasias Testiculares/diagnóstico por imagem
7.
Cancers (Basel) ; 13(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34680269

RESUMO

Colorectal cancer is the second most common cancer in Europe, and accurate lymph node staging in rectal cancer patients is essential for the selection of their treatment. MRI lymph node staging is complex, and few studies have been published regarding its reproducibility. This study assesses the inter- and intraobserver variability in lymph node size, apparent diffusion coefficient (ADC) measurements, and morphological characterization among inexperienced and experienced radiologists. Four radiologists with different levels of experience in MRI rectal cancer staging analyzed 36 MRI scans of 36 patients with rectal adenocarcinoma. Inter- and intraobserver variation was calculated using interclass correlation coefficients and Cohens-kappa statistics, respectively. Inter- and intraobserver agreement for the length and width measurements was good to excellent, and for that of ADC it was fair to good. Interobserver agreement for the assessment of irregular border was moderate, heterogeneous signal was fair, round shape was fair to moderate, and extramesorectal lymph node location was moderate to almost perfect. Intraobserver agreement for the assessment of irregular border was fair to substantial, heterogeneous signal was fair to moderate, round shape was fair to moderate, and extramesorectal lymph node location was substantial to almost perfect. Our data indicate that subjective variables such as morphological characteristics are less reproducible than numerical variables, regardless of the level of experience of the observers.

8.
Cancers (Basel) ; 13(16)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34439313

RESUMO

BACKGROUND: Rectal cancer is a common malignancy. Since the introduction of bowel-screening programs, the number of patients with advanced adenomas and early rectal cancer has increased. Despite improved diagnostics, the discrimination between rectal adenomas and early rectal cancer (i.e., pT1-T2) remains challenging. The purpose of this systematic review was to evaluate the diagnostic performance of endorectal ultrasound (ERUS) elastography in discriminating rectal adenomas from cancer. METHOD: Using PRISMA guidelines, a systematic search was performed on PubMed, Embase, and MEDLINE databases. Studies evaluating the primary staging of rectal adenomas and cancer using ERUS elastography were included. RESULTS: Six studies were identified; three evaluated the discrimination between adenomas and cancer; two evaluated adenomas and early rectal cancer (i.e., pT1-T2); one evaluated performance on different T categories. All studies reported increased diagnostic accuracy of ERUS elastography compared to ERUS. Sensitivity, specificity and accuracy ranged 0.93-1.00, 0.83-1.00 and 0.91-1.00, respectively, when discriminating adenomas from cancer. In the differentiation between adenomas and early rectal cancer, the sensitivity, specificity and accuracy were 0.82-1.00, 0.86-1.00 and 0.84-1.00, respectively. CONCLUSION: Elastography increases the accuracy of ERUS and may provide valuable information on malignant transformation of rectal lesions.

9.
Acta Radiol Open ; 10(1): 2058460120985519, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33489313

RESUMO

Sarcoidosis is a granulomatous multisystem disease of unknown etiology. Typically, the disease affects the lungs, causing enlargement of the mediastinal lymph nodes, but other organs can be affected. Neurosarcoidosis is reported in 5-10% of the patients. This case represents a 39-year-old male patient diagnosed with lung sarcoidosis. Due to neurological symptoms, a contrast-enhanced cerebral magnetic resonance imaging was performed. Neurosarcoidosis was presented with meningeal enhancement adjacent to a cyst located within the cavum septum pellucidum. The cyst dissolved spontaneously within six months. The finding of a cyst located within the septum pellucidum is rare.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA