Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Int J Food Microbiol ; 288: 13-21, 2019 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-29602513

RESUMO

The reference method for the detection and enumeration of L. monocytogenes in food (Standards EN ISO 11290-1&2) has been validated by inter-laboratory studies in the frame of the Mandate M381 from European Commission to CEN. In this paper, the collaborative studies led in 2013 on 5 matrices (cold-smoked salmon, milk powdered infant food formula, vegetables, environment, and cheese) to validate the recently revised Standard EN ISO 11290-Part 1 are reported. According to the results obtained, the revised Standard EN ISO 11290-1 can be considered as a good method for the detection of L. monocytogenes in foods and food processing environments, in particular for the matrices included in the study. According to the matrices, the sensitivity rate varied from 91.1% to 100%, and the specificity rate varied from 97.6% to 100%. Positive samples were most often detected after 24 h half-Fraser enrichment.


Assuntos
Microbiologia de Alimentos/métodos , Listeria monocytogenes/fisiologia , Queijo/microbiologia , Contagem de Colônia Microbiana , União Europeia , Limite de Detecção , Listeria monocytogenes/isolamento & purificação , Alimentos Marinhos/microbiologia , Sensibilidade e Especificidade
2.
Int J Food Microbiol ; 288: 22-31, 2019 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-29773348

RESUMO

The reference method for the detection and enumeration of L. monocytogenes in food (Standards EN ISO 11290-1&2) have been validated by inter-laboratory studies in the frame of the Mandate M381 from European Commission to CEN. In this paper, the inter-laboratory studies led in 2013 on 5 matrices (cold-smoked salmon, milk powdered infant food formula, vegetables, environment, and cheese) to validate Standard EN ISO 11290-2 are reported. According to the results obtained, the method of the revised Standard EN ISO 11290-2 can be considered as a good method for the enumeration of L. monocytogenes in foods and food processing environment, in particular for the matrices included in the study. Values of repeatability and reproducibility standard deviations can be considered satisfactory for this type of method with a confirmation stage, since most of them were below 0.3 log10, also at low levels, close to the regulatory limit of 100 CFU/g.


Assuntos
Carga Bacteriana/métodos , Microbiologia de Alimentos/métodos , Listeria monocytogenes/fisiologia , Animais , Queijo/microbiologia , Laticínios/microbiologia , União Europeia , Limite de Detecção , Listeria monocytogenes/isolamento & purificação , Reprodutibilidade dos Testes , Alimentos Marinhos/microbiologia
4.
Int J Food Microbiol ; 288: 97-101, 2019 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-30170760

RESUMO

In contaminated fish, bacterial decarboxylases produce histamine from histidine, thereby causing scombroid fish poisoning. European Regulation (EC) No 2073/2005 on microbiological criteria for foodstuffs requires using a fully validated, standardized reference HPLC method for detecting and quantifying histamine. After optimizing this reference method for the quantification of histamine in fish muscle, we organized an inter-laboratory study in 2013 across nine laboratories from seven European countries using defined criteria of method performance. The optimized, validated method was standardized (Standard EN ISO19343) as part of Mandate M381 from the European Commission to the European Committee for Standardization (CEN), signed in December 2010. The standard method was validated for three types of foodstuffs (fish with enzymatic maturation, fish without enzymatic maturation and fish sauce).


Assuntos
Cromatografia Líquida de Alta Pressão , Produtos Pesqueiros/análise , Peixes , Microbiologia de Alimentos/métodos , Histamina/análise , Animais , Proteínas de Bactérias/metabolismo , Carboxiliases/metabolismo , União Europeia
5.
Toxins (Basel) ; 8(4): 107, 2016 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-27089364

RESUMO

Staphylococcal food poisoning outbreaks are a major cause of foodborne illnesses in Europe and their notifications have been mandatory since 2005. Even though the European regulation on microbiological criteria for food defines a criterion on staphylococcal enterotoxin (SE) only in cheese and dairy products, European Food Safety Authority (EFSA) data reported that various types of food matrices are involved in staphylococcal food poisoning outbreaks. The European Screening Method (ESM) of European Union Reference Laboratory for Coagulase Positive Staphylococci (EURL CPS) was validated in 2011 for SE detection in food matrices and is currently the official method used for screening purposes in Europe. In this context, EURLCPS is annually organizing Inter-Laboratory Proficiency Testing Trials (ILPT) to evaluate the competency of the European countries' National Reference Laboratories (NRLs) to analyse SE content in food matrices. A total of 31 NRLs representing 93% of European countries participated in these ILPTs. Eight food matrices were used for ILPT over the period 2013-2015, including cheese, freeze-dried cheese, tuna, mackerel, roasted chicken, ready-to-eat food, milk, and pastry. Food samples were spiked with four SE types (i.e., SEA, SEC, SED, and SEE) at various concentrations. Homogeneity and stability studies showed that ILPT samples were both homogeneous and stable. The analysis of results obtained by participants for a total of 155 blank and 620 contaminated samples allowed for evaluation of trueness (>98%) and specificity (100%) of ESM. Further to the validation study of ESM carried out in 2011, these three ILPTs allowed for the assessment of the proficiency of the NRL network and the performance of ESM on a large variety of food matrices and samples. The ILPT design presented here will be helpful for the organization of ILPT on SE detection by NRLs or other expert laboratories.


Assuntos
Enterotoxinas/análise , Contaminação de Alimentos/análise , Ensaio de Proficiência Laboratorial , Staphylococcus , Animais , Queijo/análise , União Europeia , Leite/química , Perciformes , Aves Domésticas , Reprodutibilidade dos Testes , Alimentos Marinhos/análise , Intoxicação Alimentar Estafilocócica , Atum
6.
Brain Struct Funct ; 221(2): 913-22, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25503643

RESUMO

The phantom sound perception mechanism by which a sound perception occurs without any external sound source is still enigmatic. According to our previous fMRI study, a small region in the parietal operculum 3 was hyperactivated as a function of tinnitus periodicity in subjects with acoustic trauma tinnitus sequelae. This region was localized in the vicinity of neural correlates of middle-ear tympano-ossicular chain movements due to pressure variations. Disturbed proprioceptors are known to trigger illusory perceptions; therefore, we hypothesized that a disturbance of middle-ear proprioceptors may originate phantom sound perceptions. We designed an fMRI study that aimed to stimulate middle-ear proprioceptors by repetitive vibrations using various rates of click trains. In this study, we report that exposure to specific rates of stimuli for a few minutes at comfortable intensity level in healthy subjects distinctly triggered transient tinnitus-like aftereffects. The fMRI neural correlates of the aftereffects were unequivocally localized in the same parietal region as in acoustic trauma tinnitus sufferers. Our results strongly suggest that a middle-ear kinesthetic/proprioceptive illusion exists at the origin of acoustic trauma tinnitus via a somatosensory pathway encompassing the trigeminal system.


Assuntos
Córtex Auditivo/fisiopatologia , Lobo Temporal/fisiopatologia , Zumbido/fisiopatologia , Estimulação Acústica , Adulto , Córtex Auditivo/metabolismo , Vias Auditivas , Percepção Auditiva , Encéfalo/metabolismo , Encéfalo/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Lobo Temporal/metabolismo , Zumbido/metabolismo
7.
Food Microbiol ; 48: 171-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25791005

RESUMO

For the enumeration of Listeria monocytogenes (L. monocytogenes) in food, a sensitive enumeration method has been recently developed. This method is based on a membrane filtration of the food suspension followed by transfer of the filter on a selective medium to enumerate L. monocytogenes. An evaluation of this method was performed with several categories of foods naturally contaminated with L. monocytogenes. The results obtained with this technique were compared with those obtained from the modified reference EN ISO 11290-2 method for the enumeration of L. monocytogenes in food, and are found to provide more precise results. In most cases, the filtration method enabled to examine a greater quantity of food thus greatly improving the sensitivity of the enumeration. However, it was hardly applicable to some food categories because of filtration problems and background microbiota interference.


Assuntos
Contagem de Colônia Microbiana/métodos , Filtração/métodos , Juglans/microbiologia , Listeria monocytogenes/crescimento & desenvolvimento , Listeria/crescimento & desenvolvimento , Sensibilidade e Especificidade
8.
J Microbiol Methods ; 104: 1-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24918990

RESUMO

The European Union Reference Laboratory (EURL) for Listeria monocytogenes (Lm) collaborates with a network of 35 National Reference Laboratories (NRLs) throughout Europe. Most of these NRLs are in charge of detecting and typing Lm strains from food, environment and animals, which are isolated nationally. The past few years EURL activities have enabled NRLs to reinforce typing capabilities according to standardised protocols. Consequently the need to exchange typing data within the NRL network has emerged. That is why the EURL has recently set up a EURL Lm Database (EURL Lm DB). Each NRL contributes data, which is then shared within the network. Data include strain-typing-results (PFGE and serotyping) and epidemiological information on the strains. This article describes (1) the EURL typing activities that led to the creation of the EURL Lm DB, (2) the different steps involved in developing the EURL Lm DB, and (3) the usefulness of this database for public health. The combined use of this database, with databases on human strains, is being integrated into the European surveillance system of Lm strains circulating throughout Europe. It should improve the detection of this pathogen and provide support for outbreak investigations.


Assuntos
Bases de Dados de Ácidos Nucleicos , Microbiologia Ambiental , Microbiologia de Alimentos , Listeria monocytogenes/classificação , Listeria monocytogenes/isolamento & purificação , Animais , Técnicas de Tipagem Bacteriana , Eletroforese em Gel de Campo Pulsado , Europa (Continente) , Listeria monocytogenes/genética
9.
Foodborne Pathog Dis ; 10(10): 873-81, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24066940

RESUMO

The European Union Reference Laboratory for Listeria monocytogenes (EURL for Lm) coordinates a European network of 35 National Reference Laboratories (NRLs), most of which perform food, environmental, and veterinary Lm strain surveillance in their respective countries. The EURL activities resulted in the recent creation of a database (EURL Lm DB). Typing and related epidemiological data submitted to the EURL Lm DB will be collected and shared by all the NRLs. For a given NRL, the only criterion required in order to submit pulsed-field gel electrophoresis (PFGE) profiles to the database was the successful participation with at least one EURL PFGE and PFGE profile interpretation Proficiency Testing (PT) trial. In this context, the EURL organized a PT trial in 2012 to evaluate the NRL's ability to perform PFGE and profile interpretation. A total of 18 NRLs took part in this study. Upon request from the Food- and Waterborne Diseases and Zoonoses Programme of the European Centre for Disease Prevention and Control, 10 National Public Health Reference Laboratories (NPHLs) also took part in this PT trial. Of the 28 participating laboratories, 16 obtained results classified as "good" or "satisfactory." These 16 laboratories included 10 NRLs (56%) and 6 NPHLs (60%). Of the 22 NRLs and NHPLs that participated in the part of the PT trial related to PFGE profile interpretation, 11 laboratories obtained good results. These 11 laboratories included eight NRLs, which therefore can now submit profiles to the EURL Lm DB. This PT trial provided a valuable opportunity to facilitate and to stimulate the sharing of reproducible PFGE profiles between human and food reference laboratories.


Assuntos
Eletroforese em Gel de Campo Pulsado/normas , Microbiologia de Alimentos , Listeria monocytogenes/classificação , Listeriose/microbiologia , Animais , Técnicas de Tipagem Bacteriana/normas , União Europeia , Humanos , Ensaio de Proficiência Laboratorial/estatística & dados numéricos , Listeria monocytogenes/genética , Listeria monocytogenes/isolamento & purificação , Listeriose/epidemiologia , Saúde Pública , Reprodutibilidade dos Testes
10.
Foodborne Pathog Dis ; 2013 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-23952473

RESUMO

Abstract The European Union Reference Laboratory for Listeria monocytogenes (EURL for Lm) coordinates a European network of 35 National Reference Laboratories (NRLs), most of which perform food, environmental, and veterinary Lm strain surveillance in their respective countries. The EURL activities resulted in the recent creation of a database (EURL Lm DB). Typing and related epidemiological data submitted to the EURL Lm DB will be collected and shared by all the NRLs. For a given NRL, the only criterion required in order to submit pulsed-field gel electrophoresis (PFGE) profiles to the database was the successful participation with at least one EURL PFGE and PFGE profile interpretation Proficiency Testing (PT) trial. In this context, the EURL organized a PT trial in 2012 to evaluate the NRL's ability to perform PFGE and profile interpretation. A total of 18 NRLs took part in this study. Upon request from the Food- and Waterborne Diseases and Zoonoses Programme of the European Centre for Disease Prevention and Control, 10 National Public Health Reference Laboratories (NPHLs) also took part in this PT trial. Of the 28 participating laboratories, 16 obtained results classified as "good" or "satisfactory." These 16 laboratories included 10 NRLs (56%) and 6 NPHLs (60%). Of the 22 NRLs and NHPLs that participated in the part of the PT trial related to PFGE profile interpretation, 11 laboratories obtained good results. These 11 laboratories included eight NRLs, which therefore can now submit profiles to the EURL Lm DB. This PT trial provided a valuable opportunity to facilitate and to stimulate the sharing of reproducible PFGE profiles between human and food reference laboratories.

11.
Foodborne Pathog Dis ; 9(8): 719-26, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22870985

RESUMO

The European Union Reference Laboratory for Listeria monocytogenes (EURL for L. monocytogenes) coordinates a European network of 29 National Reference Laboratories (NRLs). Depending on a national decision, NRLs undertake food, environmental, and veterinary L. monocytogenes strain surveillance in their respective countries. In the framework of the PulseNet Europe network, two pulsed-field gel electrophoresis (PFGE) subtyping proficiency testing (PT) trials were carried out in 2003 and 2006. The obtained data showed that PFGE profiles can be compared and exchanged between laboratories. However, no further PT trial had been performed since 2006. In this context, two PT trials were organized by the EURL to evaluate the ability of NRLs to perform conventional serotyping, molecular serotyping and PFGE subtyping. Eleven well-characterized isolates of L. monocytogenes were used: six and nine isolates were tested in 2009 and 2010, respectively. Three isolates were repeated between the two studies. In the 2010 panel, a strain was tested in duplicate, and two strains were related to the same epidemiological group. The strains were analyzed blind in different laboratories (17 in 2009 and 25 in 2010) using (1) their own in-house method for serotyping methods and (2) standardized protocols based on the PulseNet protocol for PFGE. For conventional serotyping, 86.0% in 2009 and 91.0% in 2010 of the serotypes obtained were in agreement with the EURL data. For molecular serotyping, 93.5% of the results in 2009 and 95.2% in 2010 matched the EURL data. For PFGE, 68.9% in 2009 and 81.7% of the combined AscI/ApaI profiles were indistinguishable from the EURL reference profiles. The variations observed could be attributed to slight standardization defaults or, in a few cases, to a failure in DNA extraction. These PT trials provided a valuable opportunity to improve the subtyping ability of NRLs and facilitate exchanges of subtyping data in the future.


Assuntos
Eletroforese em Gel de Campo Pulsado/normas , Contaminação de Alimentos , Microbiologia de Alimentos/normas , Listeria monocytogenes/classificação , Listeria monocytogenes/isolamento & purificação , Técnicas de Tipagem Bacteriana/normas , União Europeia , Microbiologia de Alimentos/métodos , Listeria monocytogenes/genética , Sorotipagem/normas
12.
Int J Food Microbiol ; 138(3): 250-9, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20153066

RESUMO

Enterobacter sakazakii has been identified as the causative agent of serious neonatal infections, associated with high mortality rates. In most cases, powdered infant formula (PIF) has been identified as the source of infection. Recently, strains commonly referred to as E. sakazakii were proposed for classification in a new genus, Cronobacter. The standardised method for detection of Cronobacter in PIF (ISO/TS 22964; IDF/RM 210) involves pre-enrichment in buffered peptone water (BPW), followed by selective enrichment and plating onto ESIA chromogenic agar. For greater convenience and to reduce analysis cost, the common practice in the food industry is to pool samples at a constant dilution rate, in order to perform a single pre-enrichment and subsequent analysis. The consequences on the sensitivity of Cronobacter detection are not evident. We evaluated the impact of pooling on the growth of Cronobacter and PIF background microflora in samples undergoing pre-enrichment culturing in BPW. Growth of the pathogen was monitored by direct plating onto selective agar or by using a recently developed sensitive enumeration method, based on membrane filtration followed by transfer of the filter onto the selective agar. The evolution of the total bacterial population of the PIF was monitored from a qualitative and quantitative point, using molecular or classical microbiological methods. Results showed that pooling had a negative impact on the maximum population of Cronobacter attained, whereas no clear effect was observed on the onset of growth. This observation suggests strong bacterial interactions with the PIF background microflora, confirmed by a generally higher background microflora growth potential in PIF samples from various origins. These important findings suggest that, in some cases, the practice of pooling samples may affect the performance of the detection method.


Assuntos
Técnicas de Tipagem Bacteriana/métodos , Cronobacter sakazakii/crescimento & desenvolvimento , Enterobacteriaceae/crescimento & desenvolvimento , Microbiologia de Alimentos , Fórmulas Infantis , Interações Microbianas , Bactérias/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Humanos , Lactente , Fórmulas Infantis/normas
13.
Ann Otol Rhinol Laryngol ; 118(10): 728-34, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19894401

RESUMO

OBJECTIVES: We sought to verify the relevance and reliability of the main temporal bone anatomic landmarks commonly used for the middle fossa approach and to test the use of digital technology to perform an accurate analysis of these landmarks. METHODS: Ten fresh cadaveric temporal bones (5 heads) were analyzed by both computed tomographic imaging and dissection procedures, with the help of an image guidance system (DigiPointeur). Eight landmarks, which were selected for their wide citation in the otoneurosurgical literature, were studied. RESULTS: Of the 8 landmarks studied, we obtained results similar to previously published data for 2 (the distance between the temporal squama and the internal auditory meatus [IAM] fundus, and the distance between the top of the anterior semicircular canal [ASCC] arch and the IAM fundus), but divergent measurements for the other 6 (the distance between the temporal squama and the arcuate eminence; the distance between the top of the ASCC arch and the cochlear promontory; the IAM roof thickness; the angle formed by the ASCC arch plane orientation and the IAM axis; the angle formed by the head of the malleus, the geniculate ganglion, and the IAM fundus; and the correspondence between the arcuate eminence and the top of the ASCC arch). CONCLUSIONS: The use of an image guidance system allowed us to make sharp and precise measurements of the main anatomic landmarks used during a middle fossa approach. We found 6 measurements to be different from those reported in previously published data out of the 8 landmarks studied.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Crânio/anatomia & histologia , Osso Temporal/anatomia & histologia , Osso Temporal/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Crânio/diagnóstico por imagem , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
14.
Acta Otolaryngol ; 129(4): 405-10, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19153848

RESUMO

CONCLUSION: The use of an invasive marker in the ipsilateral temporal bone with mid-facial skin contouring for registration improved the position accuracy (PA) to levels required for otological and neuro-otological procedures. OBJECTIVE: The aim of this study was to compare the PA after skin contouring with the combination of anatomic landmarks or a local invasive marker and skin surface registration for intratemporal computer-assisted navigation. PATIENTS AND METHODS: Thirty-three patients undergoing a lateral skull base procedure with the Digipointeur system (Collin, Bagneux, France) based on CT scan were included in this study. Registration was obtained by a mid-facial skin contouring. In the first protocol (n=8), PA was evaluated and the position corrected for three intratemporal landmarks before evaluation of the target (round window). In a second protocol (n=25), a titanium screw was placed in the ipsilateral mastoid region before imaging. PA was measured before and after screw registration for five intratemporal landmarks. RESULTS: In the first protocol, PA did not improve after the registration of the landmarks, and PA of the target was evaluated as 4.9+/-0.64 mm. In the second protocol, PA was reduced after screw registration for all landmarks with a mean PA ranging from 0 to 2.3 mm.


Assuntos
Implante Coclear , Cirurgia Assistida por Computador/normas , Osso Temporal/cirurgia , Adulto , Parafusos Ósseos , Humanos , Estudos Prospectivos , Osso Temporal/diagnóstico por imagem , Titânio , Tomografia Computadorizada por Raios X
15.
Int J Food Microbiol ; 124(3): 271-4, 2008 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-18456358

RESUMO

For the enumeration of Listeria monocytogenes in cold-smoked salmon, a sensitive enumeration method, based on membrane filtration followed by transfer of the filter on a selective medium has been recently developed (Gnanou Besse et al., 2004, A contribution to the improvement of L. monocytogenes enumeration in cold-smoked salmon. International Journal of Food Microbiology, 91, 119-127). The aim of the study was to assess the performance of this enumeration method through an inter-laboratory study, using cold-smoked salmon artificially contaminated at 2 different levels (approximately 0.6 and 1.6 log10 CFU g(-1)). A reproducibility standard deviation of 0.23 log10 CFU g(-1)and 0.15 log10 CFU g(-1) was obtained for the method respectively at the lower level and the higher level. Under certain conditions, the uncertainty of measurement can be derived from the method reproducibility standard deviation and was calculated to be 0.46 log10 CFU g(-1) for the lower contamination level and 0.30 log10 CFU g(-1) for the higher contamination level. These values can be considered as satisfactory for such low contamination levels.


Assuntos
Técnicas de Laboratório Clínico/normas , Contagem de Colônia Microbiana/métodos , Contaminação de Alimentos/análise , Salmão/microbiologia , Alimentos Marinhos/microbiologia , Animais , Temperatura Baixa , Qualidade de Produtos para o Consumidor , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fumaça
16.
J Food Prot ; 70(7): 1678-84, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17685342

RESUMO

Enterobacter sakazakii is an occasional contaminant of powdered infant formula that can cause rare but severe foodborne infections in infants. To determine optimal methods for the detection and identification of E. sakazakii, 38 naturally contaminated samples from infant formulae factories were analyzed by two PCR-based methods and by a method (TS 22964/RM 210) developed by the International Organization for Standardization and the International Dairy Federation (ISO-IDF) using three different commercial chromogenic agars. The ISO-IDF method includes two enrichment steps, plating of the second enrichment broth on E. sakazakii isolation agar (a chromogenic selective agar), picking of five typical colonies for transfer onto tryptone soy agar, and subsequent confirmation of yellow-pigmented colonies by biochemical characterization. Twenty-two of the 38 samples were positive by the culture method. E. sakazakii isolation agar (ESIA; AES Laboratoires), COMPASS agar (Biokar Diagnostics), and Druggan-Forsythe-Iversen agar (Oxoid) compared favorably with violet red bile glucose agar (VRBG, a selective medium for Enterobacteriaceae), with positive predictive values of 86.96, 88, and 74.07%, respectively, in contrast to 47.83% for VRBG. One additional positive sample was detected using the nonpatented real-time PCR method evaluated, and those results were in 97.3% concordance with the ISO-IDF results. Some discrepancies between the results of the DuPont Qualicon BAX system and those of the ISO-IDF method could be explained by heterogeneity of contamination and sampling. Thus, both PCR-based systems were suitable for detecting and specifically identifying E. sakazakii within 1 to 2 days, and COMPASS agar and ESIA could be used interchangeably as a first-step medium to isolate presumptive E. sakazakii colonies.


Assuntos
Qualidade de Produtos para o Consumidor , Cronobacter sakazakii/isolamento & purificação , Contaminação de Alimentos/análise , Alimentos Infantis/microbiologia , Reação em Cadeia da Polimerase/métodos , Compostos Cromogênicos , Contagem de Colônia Microbiana/métodos , Meios de Cultura/química , Microbiologia de Alimentos , Humanos , Lactente , Alimentos Infantis/análise , Fórmulas Infantis , Recém-Nascido , Sensibilidade e Especificidade , Fatores de Tempo
17.
J AOAC Int ; 90(3): 756-64, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17582877

RESUMO

An earlier intralaboratory validation study based on the EN ISO 16140 Standard conducted by the Community Reference Laboratory for coagulase-positive staphylococci including Staphylocococcus aureus showed that, after an extraction step using dialysis concentration, the Vidas SET2 detection kit could be used to screen staphylococcal enterotoxins in milk and milk products. In order to fully validate Vidas SET2, an interlaboratory study was organized. Six freeze-dried samples and 3 ready-to-use concentrated extracts were analyzed by 21 laboratories according to the method, including a detection with Vidas SET2. Results did not show false-positive or -negative results. Accordance and concordance parameters were equal to 100%, corresponding to a concordance odds ratio of 1. This interlaboratory study confirmed the satisfactory outcome of the preliminary tests and of the intralaboratory study performed previously. The Vidas SET2 detection kit can be used as a method for the detection of staphylococcal enterotoxins in milk and milk products as well as the Transia Plate SET detection kit in the European screening method for official control purposes, after an extraction step followed by dialysis concentration.


Assuntos
Técnicas de Química Analítica/métodos , Enterotoxinas/análise , Microbiologia de Alimentos , Leite/microbiologia , Staphylococcus aureus/isolamento & purificação , Staphylococcus aureus/metabolismo , Animais , Técnicas Bacteriológicas , Queijo/microbiologia , Laticínios/microbiologia , Análise de Alimentos/métodos , Liofilização , Imunoglobulina G/metabolismo , Razão de Chances , Coelhos , Reprodutibilidade dos Testes
18.
Int J Food Microbiol ; 108(2): 164-71, 2006 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-16387377

RESUMO

Salad vegetables exposed to fecal contamination may cause outbreaks of hepatitis or gastro-enteritis if they are eaten raw. A procedure, based on elution with phosphate-buffered saline and concentration by filtration through membrane filters, was developed for the recovery of enteric viruses from salad leaves. The method was evaluated using lettuce leaves inoculated with hepatitis A virus (HAV), poliovirus, and MS2 bacteriophage. In addition, this method was validated by an intra-laboratory study using leaves of various salad vegetables inoculated with MS2 phage. The French standard NF V 03-110 was used to establish the general principle and the technical protocol of the validation procedure. Linear regression models describing the quantitative reactions were good fits to data in the whole range of viral concentrations tested, which was from about 1 to 4 log plaque-forming units (PFU) per 25 g of lettuce. The fractions of inoculated viruses recovered were estimated to be about 64% for HAV, 18% for poliovirus, and 29% for MS2. No significant effect of the food matrix was found using various types of salad vegetable (butter lettuce, iceberg lettuce, romaine lettuce, witloof chicory, curly endive, corn salad, rocket and watercress). Moreover, the variance of the results was constant for all levels of virus contamination within the experimental range. Intermediate reproducibility experiments were also performed to allow calculation of the uncertainty factor, which was found to be 0.58 log PFU/25 g. When used in association with phage enumeration, this validated procedure is rapid enough to be used for screening salad vegetables for evaluation of the efficacy of processes for control of pathogenic microorganisms on such foods.


Assuntos
Técnicas de Laboratório Clínico/normas , Colífagos/isolamento & purificação , Enterovirus/isolamento & purificação , Contaminação de Alimentos/análise , Vírus da Hepatite A/isolamento & purificação , Verduras/virologia , Contagem de Colônia Microbiana/métodos , Contagem de Colônia Microbiana/normas , Microbiologia de Alimentos , Modelos Lineares , Poliovirus/isolamento & purificação , RNA Viral/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ensaio de Placa Viral
19.
J AOAC Int ; 88(3): 830-41, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16001859

RESUMO

The dispersion of microbiological counting measurements, when repeating the analysis on the same material both within a laboratory (repeatability) and between laboratories (reproducibility) can be characterized by the organization of interlaboratory studies, where several sets of identical test materials are sent to several laboratories. Using the example of data generated by an interlaboratory study on enumeration of Listeria monocytogenes in foods by the standardized reference method (colony-count technique), 2 types of robust estimators of reproducibility standard deviations, based on the median, were examined, in comparison with the classical estimators, based on the mean. Experimental evaluation indicated that the 3 approaches gave consistent results for most of the combinations. The usual log10 transformation of the enumeration results was also questioned before these calculations were conducted.


Assuntos
Contagem de Colônia Microbiana , Microbiologia de Alimentos , Microbiologia , Algoritmos , Técnicas Bacteriológicas , Queijo/microbiologia , Ovos/microbiologia , Estudos de Avaliação como Assunto , Contaminação de Alimentos , Laboratórios , Listeria monocytogenes , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Int J Food Microbiol ; 91(2): 119-27, 2004 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-14996455

RESUMO

For the enumeration of Listeria monocytogenes in food, a sensitive enumeration method based on membrane filtration followed by transfer of the filter to a selective medium has been developed. This study was carried out with cold-smoked salmon, a product likely to be contaminated with L. monocytogenes. The operating protocol utilizes three filtration runs in parallel (5, 15 and 30 ml) of a 1 in 10 dilution of the salmon suspension through 0.45-microm pore-size cellulose ester membranes, and then culture of the filters on Aloa agar (AES Laboratoires, Combourg, France). The results obtained with the technique were compared with those from the reference EN ISO 11290-2 method and found to provide more precise results in the enumeration of L. monocytogenes from both artificially and naturally contaminated cold-smoked salmon. Moreover, for several samples contaminated at low levels, L. monocytogenes could be recovered only by the filtration method. The examination of increasing volumes of salmon suspension enabled readable results to be obtained for all levels of L. monocytogenes and competitive microflora investigated. In most cases, the optimised operating protocol enabled 5.1 g of salmon to be examined, instead of 0.01-0.1 g with the reference EN ISO 11290-2 method, thus improving the sensitivity of the method.


Assuntos
Contagem de Colônia Microbiana/métodos , Contaminação de Alimentos/análise , Manipulação de Alimentos/métodos , Listeria monocytogenes/isolamento & purificação , Alimentos Marinhos/microbiologia , Animais , Filtração , Microbiologia de Alimentos , Listeria monocytogenes/crescimento & desenvolvimento , Salmão , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...